Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 215
Filter
1.
J Hazard Mater ; 472: 134578, 2024 May 11.
Article in English | MEDLINE | ID: mdl-38743971

ABSTRACT

Microplastics (MPs) are widespread in agricultural soil, potentially threatening soil environmental quality and plant growth. However, toxicological research on MPs has mainly been limited to individual components (such as plants, microbes, and animals), without considering their interactions. Here, we examined earthworm-mediated effects on tomato growth and the rhizosphere micro-environment under MPs contamination. Earthworms (Eisenia fetida) mitigated the growth-inhibiting effect of MPs on tomato plant. Particularly, when exposed to environmentally relevant concentrations (ERC, 0.02% w/w) of MPs, the addition of earthworms significantly (p < 0.05) increased shoot and root dry weight by 12-13% and 13-14%, respectively. MPs significantly reduced (p < 0.05) soil ammonium (NH4+-N) (0.55-0.69 mg/kg), nitrate nitrogen (NO3--N) (7.02-8.65 mg/kg) contents, and N cycle related enzyme activities (33.47-42.39 µg/h/g) by 37.7-50.9%, 22.6-37.2%, and 34.2-48.0%, respectively, while earthworms significantly enhanced (p < 0.05) inorganic N mineralization and bioavailability. Furthermore, earthworms increased bacterial network complexity, thereby enhancing the robustness of the bacterial system to resist soil MPs stress. Meanwhile, partial least squares modelling showed that earthworms significantly influenced (p < 0.01) soil nutrients, which in turn significantly affected (p < 0.01) plant growth. Therefore, the comprehensive consideration of soil ecological composition is important for assessing MPs ecological risk.

2.
Adv Mater ; : e2403371, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702927

ABSTRACT

Calcium-ion batteries (CIBs) have emerged as a promising alternative for electrochemical energy storage. The lack of high-performance cathode materials severely limits the development of CIBs. Vanadium oxides are particularly attractive as cathode materials for CIBs, and preinsertion chemistry is often used to improve their calcium storage performance. However, the room temperature cycling lifespan of vanadium oxides in organic electrolytes still falls short of 1000 cycles. Here, based on preinsertion chemistry, the cycling life of vanadium oxides is further improved by integrated electrode and electrolyte engineering. Utilizing a tailored Ca electrolyte, the constructed freestanding (NH4)2V6O16·1.35H2O@graphene oxide@carbon nanotube (NHVO-H@GO@CNT) composite cathode achieves a 305 mAh g-1 high capacity and 10 000 cycles record-long life. Additionally, for the first time, a Ca-ion hybrid capacitor full cell is assembled and delivers a capacity of 62.8 mAh g-1. The calcium storage mechanism of NHVO-H@GO@CNT based on a two-phase reaction and the exchange of NH4 + and Ca2+ during cycling are revealed. The lattice self-regulation of V─O layers is observed and the layered vanadium oxides with Ca2+ pillars formed by ion exchange exhibit higher capacity. This work provides novel strategies to enhance the calcium storage performance of vanadium oxides via integrated structural design of electrodes and electrolyte modification.

3.
Infect Drug Resist ; 17: 1615-1623, 2024.
Article in English | MEDLINE | ID: mdl-38694890

ABSTRACT

Purpose: Infection prevention and control (IPC) has a significant impact on the prognosis after pediatric cardiac surgery. This study aimed to provide surveillance data on the incidence and density of various infections during the COVID-19 epidemic and explore the influence of multi-drug resistant organisms (MDRO) on in-hospital prognosis after congenital heart disease surgery. Methods: This single-center retrospective study included pediatric patients who underwent cardiac surgery between 2021 and 2022. The results of the postoperative bacterial and fungal cultures and antimicrobial stewardship were collected. The demographic characteristics (age and weight), operation-related parameters (RACHS-1 grade, duration of cardiopulmonary bypass, and aortic cross clamp), and surgical outcomes (extracorporeal membrane oxygenation, delayed sternal closure, mortality, duration of mechanical ventilation, length of intensive care unit stay and hospital stay, and hospitalization costs) of MDRO and non-MDRO patients were compared. Results: A total of 4776 patients were included. There were 101 infectious culture results after the operation, with a nosocomial infection rate of 2.1%. There were 40 MDRO specimens from 36 patients, 50 non-MDRO specimens from 30 patients, and 11 fungal specimens from 10 patients. The incidence of pneumonia was 1.5%, with a ventilator-associated pneumonia incidence density of 7.2/1000 patient-days. The incidence of sepsis was 0.4%, with a catheter-related bloodstream infection incidence density of 0.24/ 1000 patient-days. The incidence density of catheter-associated tract infection was 0.45/ 1000 patient-days. The incidence of surgical site infection was 0.06%. The culture proportion before commencing antibiotics was 93% and the antibiotic consumption intensity was 30.7 DDD/100 bed-days. The length of intensive care unit stay in MDRO infection patients increased compared with that in non-MDRO infection patients, 30 (18,52) vs 17 (7,62) days, p=0.05). Conclusion: The IPC performance of Fuwai Hospital achieved satisfactory results. MDRO infection can lead to prolonged intensive care unit stay.


Developed countries have advanced infection prevention and control systems and comprehensive postoperative infection monitoring data for congenital heart disease. While developing countries have initiated efforts in infection prevention and control, global attention remains substantial. This study aimed to provide comprehensive infection surveillance data and identify possible implementation for further improvement in the National Center for Cardiovascular Diseases in China (Fuwai Hospital). This was a retrospective single-center study. We included pediatric patients who underwent cardiac surgery at a pediatric surgical center between 2021 and 2022, with an age limit of 14 years. Exclusion criteria included patients undergoing medical therapy, interventional therapy, or surgical therapy in other centers in Fuwai Hospital. This study, for the first time, reports the incidence of comprehensive healthcare-associated infection surveillance and targeted surveillance (encompassing device-associated infection, surgical site infection, and multi-drug resistant organisms) after pediatric cardiac surgery at the National Center for Cardiovascular Diseases in China. In addition, we report the data on antimicrobial stewardship. We compared the surgical outcome and hospitalization costs between patients with multi-drug resistant organism infection and those without multi-drug resistant organism infection and found that multi-drug resistant organism infection can lead to prolonged intensive care unit length of stay. The Fuwai Hospital achieved satisfactory infection prevention and control results. However, because China is a large developing country exhibiting notable variations in medical conditions across its diverse regions, prospective, multicenter, observational studies should be carried out for future research based on existing evidence.

4.
Nano Lett ; 24(11): 3331-3338, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38457459

ABSTRACT

1T-MoS2 has become an ideal anode for sodium-ion batteries (SIBs). However, the metastable feature of 1T-MoS2 makes it difficult to directly synthesize under normal conditions. In addition, it easily transforms into 2H phase via restacking, resulting in inferior electrochemical performance. Herein, the electron configuration of Mo 4d orbitals is modulated and the stable 1T-MoS2 is constructed by nickel (Ni) introduction (1T-Ni-MoS2). The original electron configuration of Mo 4d orbitals is changed via the electron injection by Ni, which triggers the phase transition from 2H to 1T phase, thus improving the electrical conductivity and accelerating the redox kinetics of the material. Consequently, 1T-Ni-MoS2 exhibits superior rate capability (266.8 mAh g-1 at 10 A g-1) and excellent cycle life (358.7 mAh g-1 at 1 A g-1 after 350 cycles). In addition, the assembled Na3V2(PO4)3/C||1T-Ni-MoS2 full cells deliver excellent electrochemical properties and show great prospects in energy storage devices.

5.
Cell Host Microbe ; 32(4): 489-505.e5, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38513657

ABSTRACT

Immunotherapy has revolutionized cancer treatment, but inconsistent responses persist. Our study delves into the intriguing phenomenon of enhanced immunotherapy sensitivity in older individuals with cancers. Through a meta-analysis encompassing 25 small-to-mid-sized trials of immune checkpoint blockade (ICB), we demonstrate that older individuals exhibit heightened responsiveness to ICB therapy. To understand the underlying mechanism, we reanalyze single-cell RNA sequencing (scRNA-seq) data from multiple studies and unveil distinct upregulation of exhausted and cytotoxic T cell markers within the tumor microenvironment (TME) of older patients. Recognizing the potential role of gut microbiota in modulating the efficacy of immunotherapy, we identify an aging-enriched enterotype linked to improved immunotherapy outcomes in older patients. Fecal microbiota transplantation experiments in mice confirm the therapeutic potential of the aging-enriched enterotype, enhancing treatment sensitivity and reshaping the TME. Our discoveries confront the prevailing paradox and provide encouraging paths for tailoring cancer immunotherapy strategies according to an individual's gut microbiome profile.


Subject(s)
Gastrointestinal Microbiome , Humans , Animals , Mice , Aged , Immune Checkpoint Inhibitors/pharmacology , Immune Checkpoint Inhibitors/therapeutic use , Immunotherapy , Aging , CD3 Complex
6.
Int J Surg ; 110(4): 2025-2033, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38320095

ABSTRACT

OBJECTIVES: All patients with congenital heart disease (CHD) receive postoperative management in ICUs. Infection prevention and control (IPC) has a significant impact on prognosis. This study provides a preliminary understanding of the fundamental aspects of IPC in ICUs following CHD surgery in China. METHODS: From September to October 2023, we initiated a survey on healthcare-associated infection (HAI) management in hospitals that perform CHD surgeries independently. The questionnaires were jointly completed by the ICU physicians and IPC personnel. Duplicate or unqualified questionnaires were excluded from the study. The contents of our questionnaires covered hospital and ICU capacity, performance of the infection control department, HAI surveillance, implementation of IPC measures, and antimicrobial stewardship (AMS). Qualified questionnaires were compared according to the volume of annual CHD surgeries performed in different ICUs. Group 1 was defined as volume more than 300 cases and group 2 was defined as volume less than or equal to 300 cases. RESULTS: Sixty-two of the 118 questionnaires were completed, with a response rate of 53%. The CHD surgical volume in 2022 of the 62 hospitals was 36342, accounting for 52% of the annual CHD surgical volume (69 672) across the country. The postoperative infection rates obtained from the 15 ICUs varied from 1.3 to 15%, with a median rate of 4.5%. A total of 16 ICUs provided data on drug-resistant bacteria, Klebsiella pneumoniae exhibiting the highest frequency. More than 95% of ICUs have established complete HAI management systems. Information-based HAI surveillance was conducted in 89% of ICUs. Approximately 67% of ICUs stopped prophylactic antibiotics within 48 hours after surgery. In complex cases, carbapenems were administered empirically in 89% of ICUs. Group 1 had an advantage over group 2 in preventing multi-drug-resistant organisms (all instruments should be used alone 100% vs. 86%, P =0.047; cleaning and disinfection of environmental surfaces, 100% vs. 81%, P =0.035; antibiotic consumption control 85% vs. 61%, P =0.044) and in preventing surgical site infections (perioperative blood glucose monitoring, 88% vs. 67%, P =0.048). However, Group 1 did not perform well in preventing catheter-related bloodstream infection (delayed catheter removal due to convenience of laboratory tests, 31% vs. 6%, P =0.021) and catheter-associated urinary tract infection (delayed catheter removal due to muscle relaxant administration, 88% vs. 58%, P =0.022). CONCLUSIONS: A relatively complete HAI management system has been established throughout the country in ICUs for CHD patients. Information-based surveillance of HAI needs to be promoted, and actions should be taken to facilitate the implementation of IPC measures and AMS bundles. Training and feedback are critical for implementing IPC measures.


Subject(s)
Cross Infection , Heart Defects, Congenital , Infection Control , Intensive Care Units , Humans , China/epidemiology , Heart Defects, Congenital/surgery , Surveys and Questionnaires , Cross Infection/prevention & control , Cross Infection/epidemiology , Intensive Care Units/statistics & numerical data , Infection Control/organization & administration , Infection Control/standards , Antimicrobial Stewardship/statistics & numerical data
7.
Orthop Surg ; 16(4): 953-964, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38389204

ABSTRACT

OBJECTIVE: Surgical treatment with internal fixation, specifically percutaneous fixation with three cannulated compression screws (CCSs), is the preferred choice for young and middle-aged patients. The mechanical advantage of the optimal spatial configuration with three screws provides maximum dispersion and cortical support. We suspect that the spatial proportion of the oblique triangle configuration (OTC) in the cross-section of the femoral neck isthmus (FNI) may significantly improve shear and fatigue resistance of the fixed structure, thereby stabilizing the internal fixation system in femoral neck fracture (FNF). This study aims to explore the mechanical features of OTC and provide a mechanical basis for its clinical application. METHODS: Twenty Sawbone femurs were prepared as Pauwels type III FNF models and divided equally into two fixation groups: OTC and inverted equilateral triangle configuration (IETC). Three 7.3 mm diameter cannulated compression screws (CCSs) were used for fixation. The specimens of FNF after screw internal fixation were subjected to static loading and cyclic loading tests, respectively, with five specimens for each test. Axial stiffness, 5 mm failure load, ultimate load, shear displacement, and frontal rotational angle of two fragments were evaluated. In the cyclic loading test, the load sizes were 700 N, 1400 N, and 2100 N, respectively, and the fracture end displacement was recorded. Results were presented as means ± SD. Data with normal distributions were compared by the Student's t test. RESULTS: In the static loading test, the axial stiffness, ultimate load, shear displacement, and frontal rotational angle of two fragments were (738.64 vs. 620.74) N/mm, (2957.61 vs. 2643.06) N, (4.67 vs. 5.39) mm, and (4.01 vs. 5.52)° (p < 0.05), respectively. Comparison between the femoral head displacement after 10,000 cycles of 700N cyclic loading and total displacement after 20,000 cycles of 700-1400N cyclic loading showed the OTC group was less than the IETC group (p < 0.05). A comparison of femoral head displacement after 10,000 cycles of 1400N and 2100N cycles and total displacement after 30,000 cycles of 700-2100N cycles showed the OTC group was less than another group, but the difference was not significant (p > 0.05). CONCLUSION: When three CCSs are inserted in parallel to fix FNF, the OTC of three screws has obvious biomechanical advantages, especially in shear resistance and early postoperative weight-bearing, which provides a mechanical basis for clinical selection of ideal spatial configuration for unstable FNF.


Subject(s)
Femoral Neck Fractures , Femur Neck , Middle Aged , Humans , Femur Neck/surgery , Biomechanical Phenomena , Femoral Neck Fractures/surgery , Bone Screws , Femur , Fracture Fixation, Internal/methods
8.
Heliyon ; 10(4): e26213, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38404819

ABSTRACT

Background and objective: Treating geriatric osteoporotic distal femur fractures has always presented challenges, but developing biodegradable materials has brought new opportunities for therapeutic intervention. Despite this progress, there currently needs to be more evidence-based biomechanical guidelines for using dual plate fixation and biodegradable materials in treating osteoporotic comminuted distal femoral fractures.In this study, finite element analysis was conducted to evaluate the mechanical effectiveness of different implant materials (titanium alloys, biodegradable materials, and combinations of both) in the fixation of physiological and osteoporotic distal femoral fractures. Methods: We constructed finite element models of 33-C2 fractures and three types of plates: the Lateral Less Invasive Stabilization System (LISS) plate, the titanium-alloy medial plate (TAP), and the biodegradable plate (BP). To evaluate the biomechanical advantages in both physiological femur (PF) and osteoporotic femur (OF) conditions, three scenarios were developed: LISS + TAP, LISS + BP, and double biodegradable plates (DBPs). Five loading conditions were applied to measure structural stiffness, fracture micromotion, and implant stress: medio-lateral four-point bending, antero-posterior four-point bending, axial loading, torsional loading, and sideways falling. Several parameters were examined, including peak Von Mises Stress (VMS) of the femur and lateral plate, maximum displacement, bending angle, torsional angle of fracture, and risk of fracture. Results: In four-point bending tests, the lateral plate of the DBPs group exhibited a slightly lower peak VMS compared to the LISS + TAP and LISS + BP groups. When subjected to axial loading, the stiffness values of the LISS + TAP (OF) were 1.42 times and 1.86 times higher than LISS + BP (OF) and DBPs (OF) groups, and the peak VMS of lateral plate of DBPs (OF) construct was approximately 2% and 16% lower than that of the LISS + TAP (OF) and LISS + BP (OF) constructs. Under torsional loading, DBPs (OF) demonstrated rotational stiffness that was respectively 2% and 52% greater than that of LISS + TAP (OF) and LISS + BP (OF). Regarding the peak VMS of femur, the values of DBPs (OF) were almost 8% and 15% lower than those of LISS + TAP (OF) and LISS + BP (OF). Conclusions: The use of DBPs at 11.33 GPa facilitated early mobilization of load-bearing joints but exhibited limited ability to support full weight-bearing activities. Though LISS + TAP met practical strength requirements, one should consider the potential biological irritation and stress shielding. Thus, employing a combination of biodegradable and metal internal fixation is a valid approach to effectively treat weight-bearing joint fractures in clinical practice.

9.
Cell Death Dis ; 15(2): 135, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38346961

ABSTRACT

Impaired fatty acid oxidation (FAO) is a prominent feature of metabolic remodeling observed in pathological myocardial hypertrophy. Hepatocyte nuclear factor 4alpha (HNF4α) is closely associated with FAO in both cellular processes and disease conditions. Pellino 1 (Peli1), an E3 ligase containing a RING-like domain, plays a crucial role in catalyzing polyubiquitination of various substrates. In this study, we aimed to investigate the involvement of HNF4α and its ubiquitination, facilitated by Peli1, in FAO during pressure overload-induced cardiac hypertrophy. Peli1 systemic knockout mice (Peli1KO) display improved myocardial hypertrophy and cardiac function following transverse aortic constriction (TAC). RNA-seq analysis revealed that changes in gene expression related to lipid metabolism caused by TAC were reversed in Peli1KO mice. Importantly, both HNF4α and its downstream genes involved in FAO showed a significant increase in Peli1KO mice. We further used the antagonist BI6015 to inhibit HNF4α and delivered rAAV9-HNF4α to elevate myocardial HNF4α level, and confirmed that HNF4α inhibits the development of cardiac hypertrophy after TAC and is essential for the enhancement of FAO mediated by Peli1 knockout. In vitro experiments using BODIPY incorporation and FAO stress assay demonstrated that HNF4α enhances FAO in cardiomyocytes stimulated with angiotension II (Ang II), while Peli1 suppresses the effect of HNF4α. Mechanistically, immunoprecipitation and mass spectrometry analyses confirmed that Peli1 binds to HNF4α via its RING-like domain and promotes HNF4α ubiquitination at residues K307 and K309. These findings shed light on the underlying mechanisms contributing to impaired FAO and offer valuable insights into a promising therapeutic strategy for addressing pathological cardiac hypertrophy.


Subject(s)
Cardiomegaly , Myocardium , Animals , Mice , Cardiomegaly/genetics , Cardiomegaly/metabolism , Lipid Metabolism , Mice, Inbred C57BL , Mice, Knockout , Myocardium/pathology , Myocytes, Cardiac/metabolism , Nuclear Proteins/metabolism , Ubiquitin-Protein Ligases/genetics , Ubiquitin-Protein Ligases/metabolism , Ubiquitination
10.
J Shoulder Elbow Surg ; 33(5): e248-e260, 2024 May.
Article in English | MEDLINE | ID: mdl-38182026

ABSTRACT

BACKGROUND: Traumatic coronoid deficiency with persistent elbow instability is a challenging condition. Autologous bone graft reconstruction is often associated with a range of additional clinical problems and the outcome is often unpredictable. The purpose of this study was to design a prosthetic device that can reconstruct coronoid deficiency of any height and to evaluate its mechanical properties using finite element analysis. MATERIALS AND METHODS: A customized coronoid prosthesis was designed based on image registration, automatic measurement, and computer-aided design. After pilot study and sample size calculation, image data collected from 6 patients who underwent bilateral complete upper extremity CT scans were reconstructed. The test was divided into 3 groups: coronoid intact, prosthesis and autograft. Regan-Morrey type II and autologous olecranon osteotomy models were established. The prosthesis and autogenous olecranon were assembled to the coronoid base. Stress was applied axially along the proximal humeral diaphysis and implant micromotion and contact mechanics of the humeroulnar joint were measured at 30°, 45°, 60° and 90° of joint flexion respectively. RESULTS: At all flexion angles, the maximum stress on the coronoid articular surface was significantly reduced in the prosthesis and autograft groups, with the reduction being more significant in the latter (P < .001). With increasing flexion, the maximum stress at the coronoid articular surface increased significantly after autograft reconstruction (7.2 to 68 MPa, P < .001), whereas the humeroulnar joint obtained a similar contact mechanics pattern to that of the control group after prosthetic reconstruction. As the flexion angle increased, the relative micromotion of both the prosthesis and autograft increased significantly (0.5-1.6 vs. 0.2-1.2, Pmeasure time < 0.001, Pgroups < 0.001). Contact pressure and center-of-force paths of the humeroulnar joint experience abrupt stress changes at approximately 60° of flexion. CONCLUSION: The contact stress pattern in the humeroulnar joint is similar in prosthesis and intact coronoid groups. Autograft reconstruction increases contact stresses at the articular surface and alters the joint center-of-force path. The "stress surge phenomenon" in the humeroulnar joint surface before and after 60° of flexion may be one of the mechanisms of traumatic elbow degeneration.


Subject(s)
Elbow Joint , Joint Instability , Humans , Elbow Joint/diagnostic imaging , Elbow Joint/surgery , Joint Instability/diagnostic imaging , Joint Instability/etiology , Joint Instability/surgery , Finite Element Analysis , Pilot Projects , Prostheses and Implants , Range of Motion, Articular
11.
Adv Mater ; 36(15): e2307151, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38190759

ABSTRACT

Advanced battery electrodes require a cautious design of microscale particles with built-in nanoscale features to exploit the advantages of both micro- and nano-particles relative to their performance attributes. Herein, the dynamic behavior of nanosized Sn clusters and their host pores in carbon nanofiber) during sodiation and desodiation is revealed using a state-of-the-art 3D electron microscopic reconstruction technique. For the first time, the anomalous expansion of Sn clusters after desodiation is observed owing to the aggregation of clusters/single atoms. Pore connectivity is retained despite the anomalous expansion, suggesting inhibition of solid electrolyte interface formation in the sub-2-nm pores. Taking advantage of the built-in nanoconfinement feature, the CNF film with nanometer-sized interconnected pores hosting Sn clusters (≈2 nm) enables high utilization (95% at a high rate of 1 A g-1) of Sn active sites while maintaining an improved initial Coulombic efficiency of 87%. The findings provide insights into electrochemical reactions in a confined space and a guiding principle in electrode design for battery applications.

12.
PLoS One ; 19(1): e0296666, 2024.
Article in English | MEDLINE | ID: mdl-38227593

ABSTRACT

The development of urbanization has brought convenience to people, but it has also brought a lot of harmful construction solid waste. The machine vision detection algorithm is the crucial technology for finely sorting solid waste, which is faster and more stable than traditional methods. However, accurate identification relies on large datasets, while the datasets from the field working conditions are scarce, and the manual annotation cost of datasets is high. To rapidly and automatically generate datasets for stacked construction waste, an acquisition and detection platform was built to automatically collect different groups of RGB-D images for instances labeling. Then, based on the distribution points generation theory and data augmentation algorithm, a rapid-generation method for synthetic construction solid waste datasets was proposed. Additionally, two automatic annotation methods for real stacked construction solid waste datasets based on semi-supervised self-training and RGB-D fusion edge detection were proposed, and datasets under real-world conditions yield better models training results. Finally, two different working conditions were designed to validate these methods. Under the simple working condition, the generated dataset achieved an F1-score of 95.98, higher than 94.81 for the manually labeled dataset. In the complicated working condition, the F1-score obtained by the rapid generation method reached 97.74. In contrast, the F1-score of the dataset obtained manually labeled was only 85.97, which demonstrates the effectiveness of proposed approaches.


Subject(s)
Deep Learning , Humans , Solid Waste , Algorithms , Cell Movement , Product Labeling , Supervised Machine Learning
13.
J Hazard Mater ; 465: 133417, 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38183945

ABSTRACT

The widespread presence of soil microplastics (MPs) has become a global environmental problem. MPs of different properties (i.e., types, sizes, and concentrations) are present in the environment, while studies about the impact of MPs having different properties are limited. Thus, this study investigated the effects of three common polymers (polystyrene, polyethylene, and polypropylene) with two concentrations (0.01% and 0.1% w/w) on growth and stress response of lettuce (Lactuca sativa L.), soil enzymes, and rhizosphere microbial community. Lettuce growth was inhibited under MPs treatments. Moreover, the antioxidant system, metabolism composition, and phyllosphere microbiome of lettuce leaves was also perturbed. MPs reduced phytase activity and significantly increased dehydrogenase activity. The diversity and structure of rhizosphere microbial community were disturbed by MPs and more sensitive to polystyrene microplastics (PSMPs) and polypropylene microplastics (PPMPs). In general, the results by partial least squares pathway models (PLS-PMs) showed that the presence of MPs influenced the soil-rhizosphere-plant system, which may have essential implications for assessing the environmental risk of MPs.


Subject(s)
Microbiota , Microplastics , Polystyrenes , Plastics , Polyethylene/toxicity , Polypropylenes , Soil , Rhizosphere
14.
Eur J Radiol ; 171: 111302, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38219352

ABSTRACT

PURPOSE: The aim of our meta-analysis and systematic review was to contrast the positivity rates of [68Ga]Ga-FAPI PET and [18F]FDG PET in detecting bone and lymph node metastases across diverse cancer types. METHODS: We conducted a comprehensive search for eligible articles up until August 2023, utilizing databases including PubMed, Embase, and Web of Science. Studies focusing on the positivity rate of [68Ga]Ga-FAPI PET vs. [18F]FDG PET for bone and lymph metastasis were included. Using random-effect model, the positivity rate for [68Ga]Ga-FAPI PET and [18F]FDG PET were generated. In order to gauge the heterogeneity among aggregated studies, we utilized the I2 statistic. Additionally, we applied the Quality Assessment of Diagnostic Performance Studies (QUADAS-2) methodology to evaluate the caliber of the studies encompassed in our analysis. RESULTS: A total of 430 publications were initially identified in the search. Eventually, 25 studies, involving 779 patients, met the inclusion criteria. In terms of bone metastasis, the findings indicate no statistically significant difference between the use of [68Ga]Ga-FAPI PET and [18F]FDG PET (P = 0.34). However, concerning lymph node metastasis, the results demonstrate significant difference between the two imaging agents (P = 0.04). CONCLUSIONS: This systematic review suggests that [68Ga]Ga-FAPI PET appears to outperform [18F]FDG PET in detecting lymph node metastases. However, when it comes to bone metastasis, no statistically significant difference was observed. It is crucial to acknowledge that the insights concerning bone metastasis stem from studies with comparatively modest sample sizes. Consequently, there is a pressing demand for further, expansive prospective studies in this field.


Subject(s)
Fluorodeoxyglucose F18 , Positron-Emission Tomography , Humans , Lymphatic Metastasis/diagnostic imaging , Prospective Studies , Databases, Factual , Positron Emission Tomography Computed Tomography , Gallium Radioisotopes
15.
Proc Natl Acad Sci U S A ; 121(5): e2315871121, 2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38277439

ABSTRACT

High electrochemical reversibility is required for the application of high-energy-density lithium (Li) metal batteries; however, inactive Li formation and SEI (solid electrolyte interface)-instability-induced electrolyte consumption cause low Coulombic efficiency (CE). The prior interfacial chemical designs in terms of alloying kinetics have been used to enhance the CE of Li metal anode; however, the role of its redox chemistry at heterointerfaces remains a mystery. Herein, the relationship between heterointerfacial redox chemistry and electrochemical transformation reversibility is investigated. It is demonstrated that the lower redox potential at heterointerface contributes to higher CE, and this enhancement in CE is primarily due to the regulation of redox chemistry to Li deposition behavior rather than the formation of SEI films. Low oxidation potential facilitates the formation of the surface with the highly electrochemical binding feature after Li stripping, and low reduction potential can maintain binding ability well during subsequent Li plating, both of which homogenize Li deposition and thus optimize CE. In particular, Mg hetero-metal with ultra-low redox potential enables Li metal anode with significantly improved CE (99.6%) and stable cycle life for 700 cycles at 3.0 mA cm-2. This work provides insight into the heterointerfacial design principle of next-generation negative electrodes for highly reversible metal batteries.

16.
Materials (Basel) ; 17(2)2024 Jan 19.
Article in English | MEDLINE | ID: mdl-38276415

ABSTRACT

In the realm of engineering rotary excavation, the rigid and brittle nature of the Polycrystal Diamond Compact (PDC) layer poses challenges to the impact resistance of conical teeth. This hinders their widespread adoption and utilization. In this paper, the Abaqus simulation is used. By optimizing the parameters of the radius of the cone top arc, we analyzed the changing law of the parameters of large-diameter D30 series conical PDC teeth, such as the equivalent force, impact force, and energy absorption of the conical teeth during the impact process, and optimized the best structure of the conical PDC teeth. After being subjected to a high temperature and high pressure, we synthesized the specimen for impact testing and analyzed the PDC layer crack extension and fracture failure. The findings reveal the emergence of a stress ring below the compacted area of the conical tooth. As the radius of the cone top arc increases, so does the area of the stress ring. When R ≥ 10 mm, the maximum stress change is minimal, and at R = 10 mm, the stress change in its top unit is relatively smooth. Optimal impact resistance is achieved, withstanding a total impact work value of 7500 J. Extrusion cracks appear in the combined layer part of PDC layers I and II, but the crack source is easy to produce in the combined layer of PDC layer II and the alloy matrix and extends to both sides, and the right side extends to the surface of the conical tooth in a "dragon-claw". The failure morphology of the conical teeth includes ring shedding at the top of the PDC layer, the lateral spalling of the PDC layer, and the overall cracking of the conical teeth. Through this study, we aim to promote the popularization and application of large-diameter conical PDC teeth in the field of engineering rotary excavation.

17.
Environ Sci Technol ; 58(2): 1010-1021, 2024 Jan 16.
Article in English | MEDLINE | ID: mdl-37934921

ABSTRACT

Despite the increasing prevalence of atmospheric nanoplastics (NPs), there remains limited research on their phytotoxicity, foliar absorption, and translocation in plants. In this study, we aimed to fill this knowledge gap by investigating the physiological effects of tomato leaves exposed to differently charged NPs and foliar absorption and translocation of NPs. We found that positively charged NPs caused more pronounced physiological effects, including growth inhibition, increased antioxidant enzyme activity, and altered gene expression and metabolite composition and even significantly changed the structure and composition of the phyllosphere microbial community. Also, differently charged NPs exhibited differential foliar absorption and translocation, with the positively charged NPs penetrating more into the leaves and dispersing uniformly within the mesophyll cells. Additionally, NPs absorbed by the leaves were able to translocate to the roots. These findings provide important insights into the interactions between atmospheric NPs and crop plants and demonstrate that NPs' accumulation in crops could negatively impact agricultural production and food safety.


Subject(s)
Antioxidants , Microplastics
18.
BMC Public Health ; 23(1): 2400, 2023 12 02.
Article in English | MEDLINE | ID: mdl-38042794

ABSTRACT

BACKGROUND: In 2022, Omicron outbreaks occurred at multiple sites in China. It is of great importance to track the incidence trends and transmission dynamics of coronavirus disease 2019 (COVID-19) to guide further interventions. METHODS: Given the population size, economic level and transport level similarities, two groups of outbreaks (Shanghai vs. Chengdu and Sanya vs. Beihai) were selected for analysis. We developed the SEAIQRD, ARIMA, and LSTM models to seek optimal modeling techniques for waves associated with the Omicron variant regarding data predictive performance and mechanism transmission dynamics, respectively. In addition, we quantitatively modeled the impacts of different combinations of more stringent interventions on the course of the epidemic through scenario analyses. RESULTS: The best-performing LSTM model showed better prediction accuracy than the best-performing SEAIQRD and ARIMA models in most cases studied. The SEAIQRD model had an absolute advantage in exploring the transmission dynamics of the outbreaks. Regardless of the time to inflection point or the time to Rt curve below 1.0, Shanghai was later than Chengdu (day 46 vs. day 12/day 54 vs. day 14), and Sanya was later than Beihai (day 16 vs. day 12/day 20 vs. day 16). Regardless of the number of peak cases or the cumulative number of infections, Shanghai was higher than Chengdu (34,350 vs. 188/623,870 vs. 2,181), and Sanya was higher than Beihai (1,105 vs. 203/16,289 vs. 3,184). Scenario analyses suggested that upgrading control level in advance, while increasing the index decline rate and quarantine rate, were of great significance for shortening the time to peak and Rt below 1.0, as well as reducing the number of peak cases and final affected population. CONCLUSIONS: The LSTM model has great potential for predicting the prevalence of Omicron outbreaks, whereas the SEAIQRD model is highly effective in revealing their internal transmission mechanisms. We recommended the use of joint interventions to contain the spread of the virus.


Subject(s)
COVID-19 , Humans , COVID-19/epidemiology , China/epidemiology , Cities/epidemiology , Incidence , SARS-CoV-2
19.
Eur J Cardiothorac Surg ; 64(6)2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38078822

ABSTRACT

OBJECTIVES: Chest tube (CT) drainage is a main cause of postoperative pain in lung surgery. Here, we introduced a novel drainage strategy with bi-pigtail catheters (PCs) and conducted a randomized controlled trial to compare with conventional CT drainage after uniportal video-assisted thoracic surgery lung surgery. METHODS: A single-centre, prospective, open-labelled, randomized controlled trial (ChiCTR2000035337) was conducted with a preplanned sample size of 396. The primary outcome was the numerical pain rating scale (NPRS) on the first postoperative day. Secondary outcomes included other indicators of postoperative pain, drainage volume, duration of drainage, postoperative hospital stay, incidence of postoperative complications, CT reinsertion and medical costs. RESULTS: A total number of 396 patients were randomized between August 2020 and January 2021, 387 of whom were included in the final analysis. The baseline and clinical characteristics of the patients were well balanced between 2 groups. The NPRS on the first postoperative day was significantly lower in the PC group than in the CT group (2.40 ± 1.27 vs 3.02 ± 1.39, p < 0.001), as well as the second/third-day NPRS, the incidence of sudden severe pain (9/192, 4.7% vs 34/195, 17.4%, P < 0.001) and pain requiring intervention (19/192, 9.9% vs 46/195, 23.6%, P < 0.001). In addition, the medical cost in the PC group was lower (US$7809 ± 1646 vs US$8205 ± 1815, P = 0.025). Univariable and multivariable analyses revealed that the drainage strategy was the only factor influencing the incidence of pain requiring intervention. CONCLUSIONS: The drainage strategy with bi-PCs in patients undergoing uniportal video-assisted thoracic surgery lung surgery alleviates postoperative pain with adequate safety and efficacy.


Subject(s)
Chest Tubes , Lung Neoplasms , Humans , Chest Tubes/adverse effects , Thoracic Surgery, Video-Assisted/adverse effects , Prospective Studies , Lung Neoplasms/surgery , Pain, Postoperative/etiology , Pain, Postoperative/prevention & control , Pain, Postoperative/surgery , Pneumonectomy/adverse effects , Cardiac Catheters , Drainage/adverse effects , Lung
20.
Transl Lung Cancer Res ; 12(11): 2219-2228, 2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38090510

ABSTRACT

Background: Robotic-assisted thoracic surgery (RATS) is a safe and efficient minimally invasive thoracic approach compared to thoracotomy. Today, almost all thoracic procedures can be performed by RATS. In recent years, the Chinese government has issued some policies to support the development of domestic surgical robots, leading to the development of the Toumai® surgical robot system. This study aimed to explore the application of the Toumai® surgical robot in performing lobectomy for early-stage non-small cell lung cancer (NSCLC), and to compare its safety, surgical effect, and advantages or disadvantages compared with the mature da Vinci robotic surgical system. Methods: Patients with early-stage NSCLC undergoing robotic-assisted lobectomy in our center between November 2021 and December 2021 were enrolled in the study; Surgeries were performed through the Toumai® surgical robot and the da Vinci robotic system. Anatomical lobectomy and systematic lymph node (LN) dissection were conducted in all patients. Baseline and perioperative outcomes were analyzed to compare the two methods. Results: The combined 19 patients from the Toumai® group (n=9) and the da Vinci group (n=10) were enrolled and eligible for analyses. They had similar baseline characteristics, tumor characteristics, clinical stage, and pathological stage. Conversion to thoracotomy was not observed, and the operation time {95 minutes [interquartile range (IQR), 86.5-136.5 minutes] vs. 86 minutes (IQR, 81-102 minutes), P=0.178} and other perioperative outcomes were comparable in the two groups. There was no significant difference in the number of dissected LNs and lymphatic stations between both groups. Conclusions: The application of Toumai® surgical robot in lobectomy was preliminarily shown to be safe and effective. Compared with the mature da Vinci robotic surgery system, Toumai® surgical robot had similar technical and surgical advantages, highlighting its suitability as an optional method for the new generation of robotic-assisted thoracoscopic surgery.

SELECTION OF CITATIONS
SEARCH DETAIL
...