Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Orthop Surg Res ; 12(1): 132, 2017 Sep 15.
Article in English | MEDLINE | ID: mdl-28915925

ABSTRACT

BACKGROUND: Each part of the rear bone structure can become an anchor point for an attachment device. The objective of this study was to evaluate the stiffness and strength of different parts of the rear lumbar bone structure by axial compression damage experiments. METHODS: Five adult male lumbar bone structures from L2 to L5 were exposed. The superior and inferior articular processes, upper and lower edges of the lamina, and upper and lower edges of the spinous process were observed and isolated and then divided into six groups (n = 10). The specimens were placed between the compaction disc and the load platform in a universal testing machine, which was first preloaded to 5.0 N tension to eliminate water on the surface and then loaded to the specimen curve decline at a constant tension loading rate of 0.01 mm/s, until the specimens had been destroyed. RESULTS: Significant differences in mechanical properties were found among different parts of the rear lumbar bone structure. Compared with other parts, the lower edge of the lamina has good mechanical properties, which have a high modulus of elasticity; the superior and inferior articular processes have greater ultimate strength, which can withstand greater compressive loads; and the mechanical properties of the spinous process are poor, and it is significantly stiffer and weaker than the lamina and articular processes. CONCLUSION: These data can be useful in future spinal biomechanics research leading to better biomechanical compatibility and provide theoretical references for spinal implant materials.


Subject(s)
Lumbar Vertebrae , Biomechanical Phenomena , Compressive Strength , Elastic Modulus , Humans , Male
2.
PLoS One ; 9(12): e114326, 2014.
Article in English | MEDLINE | ID: mdl-25474112

ABSTRACT

OBJECTIVE: The objective of this biomechanical study was to evaluate the stability provided by a newly developed shape memory alloy hook (SMAH) in a cadaveric transforaminal lumbar interbody fusion (TLIF) model. METHODS: Six human cadaveric spines (L1-S2) were tested in an in vitro flexibility experiment by applying pure moments of ±8 Nm in flexion/extension, left/right lateral bending, and left/right axial rotation. After intact testing, a TLIF was performed at L4-5. Each specimen was tested for the following constructs: unilateral SMAH (USMAH); bilateral SMAH (BSMAH); unilateral pedicle screws and rods (UPS); and bilateral pedicle screws and rods (BPS). The L3-L4, L4-L5, and L5-S1 range of motion (ROM) were recorded by a Motion Analysis System. RESULTS: Compared to the other constructs, the BPS provided the most stability. The UPS significantly reduced the ROM in extension/flexion and lateral bending; the BSMAH significantly reduced the ROM in extension/flexion, lateral bending, and axial rotation; and the USMAH significantly reduced the ROM in flexion and left lateral bending compared with the intact spine (p<0.05). The USMAH slightly reduced the ROM in extension, right lateral bending and axial rotation (p>0.05). Stability provided by the USMAH compared with the UPS was not significantly different. ROMs of adjacent segments increased in all fixed constructs (p>0.05). CONCLUSIONS: Bilateral SMAH fixation can achieve immediate stability after L4-5 TLIF in vitro. Further studies are required to determine whether the SMAH can achieve fusion in vivo and alleviate adjacent segment degeneration.


Subject(s)
Lumbar Vertebrae/surgery , Lumbosacral Region/surgery , Spinal Fusion , Spine/surgery , Alloys/therapeutic use , Biomechanical Phenomena , Cadaver , Humans , Lumbosacral Region/physiopathology , Manipulation, Spinal , Microsurgery/instrumentation , Pedicle Screws , Pliability , Posture , Range of Motion, Articular , Spine/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...