Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
Add more filters










Publication year range
1.
Mol Cancer ; 22(1): 206, 2023 12 14.
Article in English | MEDLINE | ID: mdl-38093346

ABSTRACT

BACKGROUND: Social behaviors such as altruism, where one self-sacrifices for collective benefits, critically influence an organism's survival and responses to the environment. Such behaviors are widely exemplified in nature but have been underexplored in cancer cells which are conventionally seen as selfish competitive players. This multidisciplinary study explores altruism and its mechanism in breast cancer cells and its contribution to chemoresistance. METHODS: MicroRNA profiling was performed on circulating tumor cells collected from the blood of treated breast cancer patients. Cancer cell lines ectopically expressing candidate miRNA were used in co-culture experiments and treated with docetaxel. Ecological parameters like relative survival and relative fitness were assessed using flow cytometry. Functional studies and characterization performed in vitro and in vivo include proliferation, iTRAQ-mass spectrometry, RNA sequencing, inhibition by small molecules and antibodies, siRNA knockdown, CRISPR/dCas9 inhibition and fluorescence imaging of promoter reporter-expressing cells. Mathematical modeling based on evolutionary game theory was performed to simulate spatial organization of cancer cells. RESULTS: Opposing cancer processes underlie altruism: an oncogenic process involving secretion of IGFBP2 and CCL28 by the altruists to induce survival benefits in neighboring cells under taxane exposure, and a self-sacrificial tumor suppressive process impeding proliferation of altruists via cell cycle arrest. Both processes are regulated concurrently in the altruists by miR-125b, via differential NF-κB signaling specifically through IKKß. Altruistic cells persist in the tumor despite their self-sacrifice, as they can regenerate epigenetically from non-altruists via a KLF2/PCAF-mediated mechanism. The altruists maintain a sparse spatial organization by inhibiting surrounding cells from adopting the altruistic fate via a lateral inhibition mechanism involving a GAB1-PI3K-AKT-miR-125b signaling circuit. CONCLUSIONS: Our data reveal molecular mechanisms underlying manifestation, persistence and spatial spread of cancer cell altruism. A minor population behave altruistically at a cost to itself producing a collective benefit for the tumor, suggesting tumors to be dynamic social systems governed by the same rules of cooperation in social organisms. Understanding cancer cell altruism may lead to more holistic models of tumor evolution and drug response, as well as therapeutic paradigms that account for social interactions. Cancer cells constitute tractable experimental models for fields beyond oncology, like evolutionary ecology and game theory.


Subject(s)
Breast Neoplasms , MicroRNAs , Humans , Female , Altruism , Phosphatidylinositol 3-Kinases , MicroRNAs/genetics , Breast Neoplasms/genetics
2.
Clin Chem ; 63(3): 731-741, 2017 03.
Article in English | MEDLINE | ID: mdl-28073899

ABSTRACT

BACKGROUND: Molecular characterization of circulating tumor cells (CTCs) holds great promise for monitoring metastatic progression and characterizing metastatic disease. However, leukocyte and red blood cell contamination of routinely isolated CTCs makes CTC-specific molecular characterization extremely challenging. METHODS: Here we report the use of a paper-based medium for efficient extraction of microRNAs (miRNAs) from limited amounts of biological samples such as rare CTCs harvested from cancer patient blood. Specifically, we devised a workflow involving the use of Flinders Technology Associates (FTA)® Elute Card with a digital PCR-inspired "partitioning" method to extract and purify miRNAs from plasma and CTCs. RESULTS: We demonstrated the sensitivity of this method to detect miRNA expression from as few as 3 cancer cells spiked into human blood. Using this method, background miRNA expression was excluded from contaminating blood cells, and CTC-specific miRNA expression profiles were derived from breast and colorectal cancer patients. Plasma separated out during purification of CTCs could likewise be processed using the same paper-based method for miRNA detection, thereby maximizing the amount of patient-specific information that can be derived from a single blood draw. CONCLUSIONS: Overall, this paper-based extraction method enables an efficient, cost-effective workflow for maximized recovery of small RNAs from limited biological samples for downstream molecular analyses.


Subject(s)
Gene Expression Profiling/methods , MicroRNAs/blood , MicroRNAs/genetics , Neoplastic Cells, Circulating/metabolism , Paper , Humans , MicroRNAs/analysis , MicroRNAs/isolation & purification , Neoplastic Cells, Circulating/pathology , Tumor Cells, Cultured
3.
J Hematol Oncol ; 8: 75, 2015 Jun 25.
Article in English | MEDLINE | ID: mdl-26108208

ABSTRACT

Circulating tumor cells (CTCs) are cells shed from tumors or metastatic sites and are a potential biomarker for cancer diagnosis, management, and prognostication. The majority of current studies use single or infrequent CTC sampling points. This strategy assumes that changes in CTC number, as well as phenotypic and molecular characteristics, are gradual with time. In reality, little is known today about the actual kinetics of CTC dissemination and phenotypic and molecular changes in the blood of cancer patients. Herein, we show, using clinical case studies and hypothetical simulation models, how sub-optimal CTC sampling may result in misleading observations with clinical consequences, by missing out on significant CTC spikes that occur in between sampling times. Initial studies using highly frequent CTC sampling are necessary to understand the dynamics of CTC dissemination and phenotypic and molecular changes in the blood of cancer patients. Such an improved understanding will enable an optimal, study-specific sampling frequency to be assigned to individual research studies and clinical trials and better inform practical clinical decisions on cancer management strategies for patient benefits.


Subject(s)
Biomarkers, Tumor/blood , Neoplasms/metabolism , Neoplastic Cells, Circulating/metabolism , Humans , Neoplastic Cells, Circulating/pathology
4.
Mol Diagn Ther ; 18(4): 459-68, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24664550

ABSTRACT

BACKGROUND AND OBJECTIVES: Among patients with colorectal cancer (CRC), KRAS mutations were reported to occur in 30-51 % of all cases. CRC patients with KRAS mutations were reported to be non-responsive to anti-epidermal growth factor receptor (EGFR) monoclonal antibody (MoAb) treatment in many clinical trials. Hence, accurate detection of KRAS mutations would be critical in guiding the use of anti-EGFR MoAb therapies in CRC. METHODS: In this study, we carried out a detailed investigation of the efficacy of a wild-type (WT) blocking real-time polymerase chain reaction (PCR), employing WT KRAS locked nucleic acid blockers, and Sanger sequencing, for KRAS mutation detection in rare cells. Analyses were first conducted on cell lines to optimize the assay protocol which was subsequently applied to peripheral blood and tissue samples from patients with CRC. RESULTS: The optimized assay provided a superior sensitivity enabling detection of as little as two cells with mutated KRAS in the background of 10(4) WT cells (0.02 %). The feasibility of this assay was further investigated to assess the KRAS status of 45 colorectal tissue samples, which had been tested previously, using a conventional PCR sequencing approach. The analysis showed a mutational discordance between these two methods in 4 of 18 WT cases. CONCLUSION: Our results present a simple, effective, and robust method for KRAS mutation detection in both paraffin embedded tissues and circulating tumour cells, at single-cell level. The method greatly enhances the detection sensitivity and alleviates the need of exhaustively removing co-enriched contaminating lymphocytes.


Subject(s)
Colorectal Neoplasms/genetics , Colorectal Neoplasms/pathology , Neoplastic Cells, Circulating/pathology , ras Proteins/genetics , Humans , Mutation , Paraffin , Paraffin Embedding
5.
Lab Chip ; 12(21): 4388-96, 2012 Nov 07.
Article in English | MEDLINE | ID: mdl-22930096

ABSTRACT

Herein we present a lab-chip device for highly efficient and rapid detection of circulating tumor cells (CTCs) from whole blood samples. The device utilizes a microfabricated silicon microsieve with a densely packed pore array (10(5) pores per device) to rapidly separate tumor cells from whole blood, utilizing the size and deformability differences between the CTCs and normal blood cells. The whole process, including tumor cell capture, antibody staining, removal of unwanted contaminants and immunofluorescence imaging, was performed directly on the microsieve within an integrated microfluidic unit, interconnected to a peristaltic pump for fluid regulation and a fluorescence microscope for cell counting. The latter was equipped with a dedicated digital image processing program which was developed to automatically categorize the captured cells based on the immunofluorescence images. A high recovery rate of >80% was achieved with defined numbers of MCF-7 and HepG2 cancer cells spiked into human whole blood and filtered at a rapid flow rate of 1 mL min(-1). The device was further validated with blood drawn from various cancer patients (8 samples). The whole process, from sample input to result, was completed in 1.5 h. In addition, we have also successfully demonstrated on-microsieve fluorescence in situ hybridization for single cell molecular analysis. This simple method has great potential to supplant existing complex CTC detection schemes for cancer metastasis analysis.


Subject(s)
Cell Separation/methods , In Situ Hybridization, Fluorescence/methods , Microfluidic Analytical Techniques/methods , Neoplastic Cells, Circulating/pathology , Cell Count , Cell Separation/instrumentation , Equipment Design , Hep G2 Cells , Humans , In Situ Hybridization, Fluorescence/instrumentation , MCF-7 Cells , Microfluidic Analytical Techniques/instrumentation , Tumor Cells, Cultured
6.
Electrophoresis ; 33(5): 788-96, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22437793

ABSTRACT

Mutation and polymorphism detection is of increasing importance for a variety of medical applications, including identification of cancer biomarkers and genotyping for inherited genetic disorders. Among various mutation-screening technologies, enzyme mismatch cleavage (EMC) represents a great potential as an ideal scanning method for its simplicity and high efficiency, where the heteroduplex DNAs are recognized and cleaved into DNA fragments by mismatch-recognizing nucleases. Thereby, the enzymatic cleavage activities of the resolving nucleases play a critical role for the EMC sensitivity. In this study, we utilized the unique features of microfluidic capillary electrophoresis and de novo gene synthesis to explore the enzymatic properties of T7 endonuclease I and Surveyor nuclease for EMC. Homoduplex and HE DNAs with specific mismatches at desired positions were synthesized using PCR (polymerase chain reaction) gene synthesis. The effects of nonspecific cleavage, preference of mismatches, exonuclease activity, incubation time, and DNA loading capability were systematically examined. In addition, the utilization of a thermostable DNA ligase for real-time ligase mediation was investigated. Analysis of the experimental results has led to new insights into the enzymatic cleavage activities of T7 endonuclease I and Surveyor nuclease, and aided in optimizing EMC conditions, which enhance the sensitivity and efficiency in screening of unknown DNA variations.


Subject(s)
DNA Ligases/metabolism , DNA Mutational Analysis/methods , Deoxyribonuclease I/metabolism , Deoxyribonucleases/metabolism , Electrophoresis, Microchip/methods , Genes, Bacterial , Models, Molecular , Mutation , Sensitivity and Specificity
7.
Methods Mol Biol ; 852: 23-34, 2012.
Article in English | MEDLINE | ID: mdl-22328423

ABSTRACT

This chapter introduces a simple, cost-effective TopDown one-step gene synthesis method, which is suitable for the sequence assembly of fairly long DNA. This method can be distinguished from conventional gene synthesis methods by two key features: (1) the melting temperature of the outer primers is designed to be ∼8°C lower than that of the assembly oligonucleotides, and (2) different annealing temperatures are utilized to selectively control the efficiencies of oligonucleotide assembly and full-length template amplification. This method eliminates the interference between polymerase chain reactions (PCR) assembly and amplification in one-step gene synthesis. Additionally, the TopDown gene synthesis has been combined with the LCGreen I DNA fluorescence dye in a real-time gene synthesis approach for investigating the stepwise efficiency and kinetics of PCR-based gene synthesis. The obtained real-time fluorescence signals are compared with gel electrophoresis results to optimize gene synthesis conditions.


Subject(s)
Computer Systems , DNA/genetics , Genes, Synthetic/genetics , Oligodeoxyribonucleotides/biosynthesis , Oligodeoxyribonucleotides/genetics , Computer-Aided Design , Cost-Benefit Analysis , DNA/chemistry , DNA/isolation & purification , Electrophoresis, Agar Gel , Indicators and Reagents/chemistry , Nucleic Acid Denaturation , Oligodeoxyribonucleotides/chemistry , Oligodeoxyribonucleotides/isolation & purification , Polymerase Chain Reaction , Transition Temperature
8.
Methods Mol Biol ; 852: 225-34, 2012.
Article in English | MEDLINE | ID: mdl-22328437

ABSTRACT

This chapter presents TmPrime, a computer program to design oligonucleotide for both ligase chain reaction (LCR)- and polymerase chain reaction (PCR)-based de novo gene synthesis. The program divides a long input DNA sequence based on user-specified melting temperatures and assembly conditions, and dynamically optimizes the length of oligonucleotides to achieve homologous melting temperatures. The output reports the melting temperatures, oligonucleotide sequences, and potential formation of secondary structures in a PDF file, which will be sent to the user via e-mail. The program also provides functions on sequence pooling to separate long genes into smaller pieces for multipool assembly and codon optimization for expression based on the highest organism-specific codon frequency. This software has been successfully used in the design and synthesis of various genes with total length >20 kbp. This program is freely available at http://prime.ibn.a-star.edu.sg.


Subject(s)
Oligodeoxyribonucleotides/biosynthesis , Oligodeoxyribonucleotides/genetics , Software , Base Sequence , Codon/genetics , Computational Biology , Humans , Ligase Chain Reaction , Molecular Sequence Data , Nucleic Acid Denaturation , Oligodeoxyribonucleotides/chemistry , Polymerase Chain Reaction
9.
Biomicrofluidics ; 5(3): 34107-341079, 2011 Sep.
Article in English | MEDLINE | ID: mdl-22662036

ABSTRACT

Sample preparation is one of the most crucial processes for nucleic acids based disease diagnosis. Several steps are required for nucleic acids extraction, impurity washes, and DNA/RNA elution. Careful sample preparation is vital to the obtaining of reliable diagnosis, especially with low copies of pathogens and cells. This paper describes a low-cost, disposable lab cartridge for automatic sample preparation, which is capable of handling flexible sample volumes of 10 µl to 1 ml. This plastic cartridge contains all the necessary reagents for pathogen and cell lysis, DNA/RNA extraction, impurity washes, DNA/RNA elution and waste processing in a completely sealed cartridge. The entire sample preparation processes are automatically conducted within the cartridge on a desktop unit using a pneumatic fluid manipulation approach. Reagents transportation is achieved with a combination of push and pull forces (with compressed air and vacuum, respectively), which are connected to the pneumatic inlets at the bottom of the cartridge. These pneumatic forces are regulated by pinch valve manifold and two pneumatic syringe pumps within the desktop unit. The performance of this pneumatic reagent delivery method was examined. We have demonstrated the capability of the on-cartridge RNA extraction and cancer-specific gene amplification from 10 copies of MCF-7 breast cancer cells. The on-cartridge DNA recovery efficiency was 54-63%, which was comparable to or better than the conventional manual approach using silica spin column. The lab cartridge would be suitable for integration with lab-chip real-time polymerase chain reaction devices in providing a portable system for decentralized disease diagnosis.

10.
Lab Chip ; 10(22): 3103-11, 2010 Nov 21.
Article in English | MEDLINE | ID: mdl-20865195

ABSTRACT

Herein we present a fully automated system with pseudo-multiplexing capability for rapid infectious disease diagnosis. The all-in-one system was comprised of a polymer cartridge, a miniaturized thermal cycler, 1-color, 3-chamber fluorescence detectors for real-time reverse transcription polymerase chain reaction (RRT-PCR), and a pneumatic fluidic delivery unit consisting of two pinch-valve manifolds and two pneumatic pumps. The disposable, self-contained cartridge held all the necessary reagents for viral RNA purification and reverse transcription polymerase chain reaction (RT-PCR) detection, which took place all within the completely sealed cartridge. The operator only needed to pipette the patient's sample with lysis buffer into the cartridge, and the system would automatically perform the entire sample preparation and diagnosis within 2.5 h. We have successfully employed this system for seasonal influenza A H1N1 typing and sub-typing, obtaining comparable sensitivity as the experiments conducted using manual RNA extraction and commercial thermal cycler. A minimum detectable virus loading of 100 copies per µl has been determined by serial dilution experiments. This all-in-one desktop system would be suitable for decentralized disease diagnosis at immigration check points and outpatient clinics, and would not require highly skilled operators.


Subject(s)
Influenza, Human/diagnosis , Microfluidic Analytical Techniques/instrumentation , Reverse Transcriptase Polymerase Chain Reaction/instrumentation , Humans , Influenza A Virus, H1N1 Subtype/classification , Influenza A Virus, H1N1 Subtype/genetics , Influenza A Virus, H1N1 Subtype/isolation & purification , Influenza, Human/virology , Microfluidic Analytical Techniques/methods , Nasopharynx/virology , Polymethyl Methacrylate , RNA, Viral/analysis , RNA, Viral/isolation & purification , Reagent Kits, Diagnostic , Reverse Transcriptase Polymerase Chain Reaction/methods , Spectrometry, Fluorescence , Time Factors
11.
Anal Biochem ; 406(1): 51-60, 2010 Nov 01.
Article in English | MEDLINE | ID: mdl-20599643

ABSTRACT

Here we present a simple, highly efficient, universal automatic kinetics switch (AKS) gene synthesis method that enables synthesis of DNA up to 1.6kbp from 1nM oligonucleotide with just one polymerase chain reaction (PCR) process. This method eliminates the interference between the PCR assembly and amplification in one-step gene synthesis and simultaneously maximizes the amplification of emerged desired DNA by using a pair of flanked primers. In addition, we describe an analytical model of PCR gene synthesis based on the thermodynamics and kinetics of DNA hybridization. The kinetics difference between standard PCR amplification and one-step PCR gene synthesis is analyzed using this model and is validated using real-time gene synthesis with eight gene segments (318-1656bp). The effects of oligonucleotide concentration, stringency of annealing temperature, annealing time, extension time, and PCR buffer conditions are examined systematically. Analysis of the experimental results leads to new insights into the gene synthesis process and aids in optimizing gene synthesis conditions. We further extend this method for multiplexing gene assembly with a total DNA length up to 5.74kbp from 1nM oligonucleotide.


Subject(s)
Genes/genetics , Polymerase Chain Reaction/methods , Automation , Buffers , DNA Primers/genetics , Humans , Kinetics , Oligodeoxyribonucleotides/genetics , Temperature
12.
J Am Chem Soc ; 131(34): 12211-7, 2009 Sep 02.
Article in English | MEDLINE | ID: mdl-19655794

ABSTRACT

In this report, an electrical detection scheme for the quantification of DNA using a nanogap sensor array is detailed. The prime objective is to develop a novel sensing procedure, based on the electronic transduction mechanism, which would mitigate the problems intrinsic to nanostructure-based biosensing devices. Design considerations of the sensor array take into account the feasibility of mass production in a cost-effective way by using standard silicon microfabrication technologies. The sensing mechanism relies on bridging the nanogap upon hybridization of the two termini of a target DNA with two different surface-bound capture probes, followed by a simple metallization step. About 2 orders of magnitude enhancement in conductance, as referred to a clean background (<1.0 pS) observed at a control sensor, was obtained in the presence of as little as 1.0 fM target DNA. This sensitivity is comparable to the best of electrochemical/electrical biosensors. A linear relationship between the conductance and the DNA concentration was obtained from 1.0 fM to 1.0 pM with an exceptional signal intensity of 2.1 x 10(4)% change per unit concentration. This change in conductivity is so large that it can unambiguously detect the concentration of DNA quantitatively and may obviate the need for target amplification used in current DNA tests. Moreover, the sensor array exhibited excellent single-base mismatch discrimination due to its unique vertically aligned nanostructure and the two-probe configuration.


Subject(s)
DNA/analysis , Nanotechnology/instrumentation , Nanotechnology/methods , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , DNA/chemistry , DNA Probes/chemistry , Electrochemistry , Nanowires , Nucleic Acid Hybridization , Reproducibility of Results , Silver/chemistry
13.
Nucleic Acids Res ; 37(Web Server issue): W214-21, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19515937

ABSTRACT

Herein we present TmPrime, a computer program to design oligonucleotide sets for gene assembly by both ligase chain reaction (LCR) and polymerase chain reaction (PCR). TmPrime offers much flexibility with no constraints on the gene and oligonucleotide lengths. The program divides the long input DNA sequence based on the input desired melting temperature, and dynamically optimizes the length of oligonucleotides to achieve homologous melting temperatures. The output reports the melting temperatures, oligonucleotide sequences and potential formation of secondary structures. Our program also provides functions on sequence pooling to separate long genes into smaller pieces for multi-pool assembly and codon optimization for expression. The software has been successfully used in the design and synthesis of green fluorescent protein fragment (GFPuv) (760 bp), human protein kinase B-2 (PKB2) (1446 bp) and the promoter of human calcium-binding protein A4 (S100A4) (752 bp) using real-time PCR assembly with LCGreen I, which offers a novel approach to compare the efficiency of gene synthesis. The purity of assembled products is successfully estimated with the use of melting curve analysis, which would potentially eliminate the necessity for agarose gel electrophoresis. This program is freely available at http://prime.ibn.a-star.edu.sg.


Subject(s)
Genes, Synthetic , Oligonucleotides/chemistry , Software , Humans , Ligase Chain Reaction , Polymerase Chain Reaction , Proteins/genetics , Sequence Analysis, DNA
14.
Nucleic Acids Res ; 37(7): e51, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19264797

ABSTRACT

Herein we present a simple, cost-effective TopDown (TD) gene synthesis method that eliminates the interference between the polymerase chain reactions (PCR) assembly and amplification in one-step gene synthesis. The method involves two key steps: (i) design of outer primers and assembly oligonucleotide set with a melting temperature difference of >10 degrees C and (ii) utilization of annealing temperatures to selectively control the efficiencies of oligonucleotide assembly and full-length template amplification. In addition, we have combined the proposed method with real-time PCR to analyze the step-wise efficiency and the kinetics of the gene synthesis process. Gel electrophoresis results are compared with real-time fluorescence signals to investigate the effects of oligonucleotide concentration, outer primer concentration, stringency of annealing temperature, and number of PCR cycles. Analysis of the experimental results has led to insights into the gene synthesis process. We further discuss the conditions for preventing the formation of spurious DNA products. The TD real-time gene synthesis method provides a simple and efficient method for assembling fairly long DNA sequence, and aids in optimizing gene synthesis conditions. To our knowledge, this is the first report that utilizes real-time PCR for gene synthesis.


Subject(s)
Genes, Synthetic , Polymerase Chain Reaction/methods , DNA Primers , Electrophoresis, Agar Gel , Fluorescent Dyes , Humans , Kinetics , S100 Calcium-Binding Protein A4 , S100 Proteins/genetics , Temperature
15.
Lab Chip ; 9(2): 276-85, 2009 Jan 21.
Article in English | MEDLINE | ID: mdl-19107285

ABSTRACT

Herein we present an integrated microfluidic device capable of performing two-step gene synthesis to assemble a pool of oligonucleotides into genes with the desired coding sequence. The device comprised of two polymerase chain reactions (PCRs), temperature-controlled hydrogel valves, electromagnetic micromixer, shuttle micromixer, volume meters, and magnetic beads based solid-phase PCR purification, fabricated using a fast prototyping method without lithography process. The fabricated device is combined with a miniaturized thermal cycler to perform gene synthesis. Oligonucleotides were first assembled into genes by polymerase chain assembly (PCA), and the full-length gene was amplified by a second PCR. The synthesized gene was further separated from the PCR reaction mixture by the solid-phase PCR purification. We have successfully used this device to synthesize a green fluorescent protein fragment (GFPuv) (760 bp), and obtained comparable synthesis yield and error rate with experiments conducted in a PCR tube within a commercial thermal cycler. The resulting error rate determined by DNA sequencing was 1 per 250 bp. To our knowledge, this is the first microfluidic device demonstrating integrated two-step gene synthesis.


Subject(s)
Genes, Synthetic , Microfluidic Analytical Techniques/instrumentation , DNA/chemical synthesis , DNA Mutational Analysis , Microfluidic Analytical Techniques/methods , Nucleic Acid Amplification Techniques , Polymerase Chain Reaction
16.
Org Lett ; 8(11): 2357-60, 2006 May 25.
Article in English | MEDLINE | ID: mdl-16706525

ABSTRACT

[reaction: see text] We report the development of a safety-catch photolabile linker that allows the light-directed synthesis and spatially selective photorelease of oligonucleotides from microarrays. The linker remains stable to light during DNA synthesis, and is activated for photorelease after acidic hydrolysis. We demonstrate that the photoreleased oligonucleotides can be amplified by PCR to produce double stranded DNA. The advantages offered by this linker could aid the development of an automated gene synthesis platform.


Subject(s)
DNA/chemical synthesis , Oligonucleotides/chemical synthesis , Photolysis , DNA/chemistry , Molecular Structure , Oligonucleotides/chemistry
17.
J Am Chem Soc ; 126(51): 16704-5, 2004 Dec 29.
Article in English | MEDLINE | ID: mdl-15612691

ABSTRACT

We describe the development of photolabile protecting groups based on the 3,4,5-trimethoxyphenacyl group (TMP). Orthogonal safety-catches were created by introducing an acid-activatible dimethyl ketal (AA-TMP) and an oxidatively activatible 1,3-dithiane (OA-TMP) into the photolabile TMP group. We demonstrate the application of these protecting groups in light-directed synthesis of small molecule microarrays with diversity elements radially attached to a hydroxyproline scaffold.


Subject(s)
Acetophenones/chemistry , Combinatorial Chemistry Techniques/methods , Microarray Analysis/methods , Benzoin/chemistry , Hydroxyproline/chemistry , Photolysis
18.
Nucleic Acids Res ; 32(17): 5011-8, 2004.
Article in English | MEDLINE | ID: mdl-15448182

ABSTRACT

A basic problem in gene synthesis is the acquisition of many short oligonucleotide sequences needed for the assembly of genes. Photolithographic methods for the massively parallel synthesis of high-density oligonucleotide arrays provides a potential source, once appropriate methods have been devised for their elution in forms suitable for enzyme-catalyzed assembly. Here, we describe a method based on the photolithographic synthesis of long (>60mers) single-stranded oligonucleotides, using a modified maskless array synthesizer. Once the covalent bond between the DNA and the glass surface is cleaved, the full-length oligonucleotides are selected and amplified using PCR. After cleavage of flanking primer sites, a population of unique, internal 40mer dsDNA sequences are released and are ready for use in biological applications. Subsequent gene assembly experiments using this DNA pool were performed and were successful in creating longer DNA fragments. This is the first report demonstrating the use of eluted chip oligonucleotides in biological applications such as PCR and assembly PCR.


Subject(s)
Genes , Oligodeoxyribonucleotides/biosynthesis , Oligonucleotide Array Sequence Analysis/methods , Polymerase Chain Reaction , Oligodeoxyribonucleotides/chemistry , Oligodeoxyribonucleotides/isolation & purification
SELECTION OF CITATIONS
SEARCH DETAIL