Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Materials (Basel) ; 17(10)2024 May 16.
Article in English | MEDLINE | ID: mdl-38793447

ABSTRACT

In this study, lead(II) sulphide (PbS) nanoparticles of varying particle sizes were synthesized using the hot injection method, employing 1-octadecene (ODE) as a coordinating ligand in conjunction with oleylamine (OAm). This synthesis approach was compared with the preparation of hexagonal-shaped nanoparticles through the ligand of 1-Dodecanethiol (DT), resulting in DT-capped PbS nanoparticles. The prepared nanoparticles were characterized using multiple techniques including photoluminescence (PL), transmission electron microscopy (TEM), X-ray diffraction (XRD), and Fourier-transform infrared spectroscopy (FT-IR). The condensation reaction of DT ligands led to various nanoparticles within the range of 34.87 nm to 35.87 nm across different synthesis temperatures (120 °C, 150 °C, 180 °C, 210 °C, and 240 °C). The PbS with DT ligands exhibited a highly crystalline and superhydrophilic structure. Interestingly, near-infrared (NIR)-PL analysis revealed peaks at 1100 nm, representing the lowest-energy excitonic absorption peak of PbS nanoparticles for both ligands. This suggests their potential utility in various applications, including IR photoreactors, as well as in the development of non-toxic nanoparticles for potential applications in in vivo bioimaging.

2.
Materials (Basel) ; 15(24)2022 Dec 13.
Article in English | MEDLINE | ID: mdl-36556708

ABSTRACT

Perovskite CsPbI3 quantum dots (QDs) were synthesized as a hole-transporting layer (HTL) of a planar perovskite solar cell (PSC). By using the Octam solution during the ligand engineering, CsPbI3 QDs exhibits a denser grain and a larger grain size due to the short-chain ligands of Octam. In addition, CsPbI3 QDs with the Octam solution showed a smooth and uniform surface on MAPbI3 film, indicating the QDs improved the microstructure of the MAPbI3 perovskite film. As a result, the PSC with CsPbI3 QDs as an HTL has the optimal open-circuit voltage as 1.09 V, the short-circuit current as 20.5 mA/cm2, and the fill factor (FF) as 75.7%, and the power conversion efficiency (PCE) as 17.0%. Hence, it is inferred that introducing QDs as a HTL via the ligand engineering can effectively improve the device performance of the PSC.

3.
Sensors (Basel) ; 16(10)2016 Oct 22.
Article in English | MEDLINE | ID: mdl-27782089

ABSTRACT

In this paper, a novel fiber-optic sensing system based on fiber Bragg gratings (FBGs) to measure foot plantar pressure is proposed. This study first explores the Pedar-X insole foot pressure types of the adult-size chart and then defines six measurement areas to effectively identify four foot types: neutral foot, cavus foot, supinated foot and flat foot. The plantar pressure signals are detected by only six FBGs, which are embedded in silicone rubber. The performance of the fiber optic sensing is examined and compared with a digital pressure plate of i-Step P1000 with 1024 barometric sensors. In the experiment, there are 11 participants with different foot types to participate in the test. The Pearson correlation coefficient, which is determined from the measured results of the homemade fiber-optic plantar pressure system and i-Step P1000 plantar pressure plate, reaches up to 0.671 (p < 0.01). According to the measured results from the plantar pressure data, the proposed fiber optic sensing system can successfully identify the four different foot types. Measurements of this study have demonstrated the feasibility of the proposed system so that it can be an alternative for plantar pressure detection systems.

SELECTION OF CITATIONS
SEARCH DETAIL
...