Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Legal Med ; 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38561435

ABSTRACT

Initial experiences with magnetic resonance imaging (MRI) of living strangulation victims demonstrated additional findings of internal injuries compared to the standard clinical forensic examination. However, existing studies on the use of MRI for this purpose mostly focused on the first 48 h after the incident. The aims of this study were (a) to evaluate the longitudinal visibility of MRI findings after violence against the neck by performing two MRI examinations within 12 days and a minimum of four days between both MRI scans and (b) to assess which MRI sequences were most helpful for the detection of injuries. Twenty strangulation victims participated in this study and underwent one (n = 8) or two (n = 12) MRI scans. The first MRI examination was conducted during the first five days, the second five to 12 days after the incident. Two blinded radiologists assessed the MRI data and looked for lesions in the structures of the neck. In total, 140 findings were reported in the 32 MRI examinations. Most of the findings were detected in the thyroid and the muscles of the neck. T2-weighted SPACE with fat suppression, T1-weighted TSE and T1-weighted MPRAGE were rated as the most helpful MRI sequences. Subjects who showed findings in the initial scan also demonstrated comparable results in the second scan, which was performed on average 8.4 days after the incident. Our results show that even up to 12 days after the incident, the criminal proceeding of strangulation cases may greatly profit from the information provided by an MRI examination of the neck in addition to the standard clinical forensic examination.

2.
J Clin Med ; 11(10)2022 May 16.
Article in English | MEDLINE | ID: mdl-35628923

ABSTRACT

Objectives: Ischemic stroke is a leading cause of mortality and acquired disability worldwide and thus plays an enormous health-economic role. Imaging of choice is computed-tomographic (CT) or magnetic resonance imaging (MRI), especially diffusion-weighted (DW) sequences. However, MR imaging is associated with high costs and therefore has a limited availability leading to low-field-MRI techniques increasingly coming into focus. Thus, the aim of our study was to assess the potential of stroke imaging with low-field MRI. Material and Methods: A scanner comparison was performed including 27 patients (17 stroke cohort, 10 control group). For each patient, a brain scan was performed first with a 1.5T scanner and afterwards with a 0.55T scanner. Scan protocols were as identical as possible and optimized. Data analysis was performed in three steps: All DWI/ADC (apparent diffusion coefficient) and FLAIR (fluid attenuated inversion recovery) sequences underwent Likert rating with respect to image impression, resolution, noise, contrast, and diagnostic quality and were evaluated by two radiologists regarding number and localization of DWI and FLAIR lesions in a blinded fashion. Then segmentation of lesion volumes was performed by two other radiologists on DWI/ADC and FLAIR. Results: DWI/ADC lesions could be diagnosed with the same reliability by the most experienced reader in the 0.55T and 1.5T sequences (specificity 100% and sensitivity 92.9%, respectively). False positive findings did not occur. Detection of number/location of FLAIR lesions was mostly equivalent between 0.55T and 1.5T sequences. No significant difference (p = 0.789−0.104) for FLAIR resolution and contrast was observed regarding Likert scaling. For DWI/ADC noise, the 0.55T sequences were significantly superior (p < 0.026). Otherwise, the 1.5T sequences were significantly superior (p < 0.029). There was no significant difference in infarct volume and volume of infarct demarcation between the 0.55T and 1.5T sequences, when detectable. Conclusions: Low-field MRI stroke imaging at 0.55T may not be inferior to scanners with higher field strengths and thus has great potential as a low-cost alternative in future stroke diagnostics. However, there are limitations in the detection of very small infarcts. Further technical developments with follow-up studies must show whether this problem can be solved.

SELECTION OF CITATIONS
SEARCH DETAIL
...