Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Vet Med Sci ; 6(3): 543-549, 2020 08.
Article in English | MEDLINE | ID: mdl-32281259

ABSTRACT

BACKGROUND AND OBJECTIVE: There are a growing number of porcine models being used for orthopaedic experiments for human beings. Therefore, pain management of those research pigs using ultrasound (US)-guided nerve block can be usefully performed. The aim of this study is to determine optimal US approaches for accessing and localizing the sciatic nerve at the midthigh level, a relevant block site for hindlimb surgery in female Yorkshire pigs. METHODS: As a first step, we dissected the intubated, blood-washed out pigs (n = 3) and confirmed the anatomical position of the sciatic nerve at midthigh level. After dissection, we found the sciatic nerve, connected with nerve stimulator, and checked the dorsiflexion or plantar flexion of the hindlimb. We matched the sciatic nerve location with the US image. After the pigs were euthanized, the neural structures of the sciatic nerve were confirmed by histological examination with H&E staining. In second step, a main US-guided sciatic nerve block study was done in the intubated, live pigs (n = 8) based on the above study. RESULTS: In lateral position, the effective US-guided nerve block site was about 6 cm from the patella crease level; immediately proximal to the bifurcation of the sciatic nerve into the tibial nerve and common peroneal nerve. The distal femur was selected as the landmark. There were no vessels or other nerves surrounding the sciatic nerve. The needle-tip was positioned less than 1 cm lateral from the distal femur and about 2 cm deep to skin. 'Donut sign' in US images was confirmed in all 16 nerves. CONCLUSIONS: Midthigh level sciatic nerve is located superficially, which enables nerve block to be easily performed using US. This is the first study to describe midthigh sciatic nerve block in the lateral position under US guidance in a porcine model from a clinical perspective.


Subject(s)
Nerve Block/veterinary , Sciatic Nerve/physiology , Sus scrofa/surgery , Ultrasonography, Interventional/veterinary , Animals , Female , Humans , Models, Animal , Nerve Block/methods
2.
J Int Med Res ; 45(3): 1042-1053, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28534703

ABSTRACT

Objective The efficacy of chlorhexidine- and silver sulfadiazine-coated central venous catheters (CSS-CVC) against catheter-related infection remains controversial. We hypothesized that the loss of silver nanoparticles may reduce the antibacterial efficacy of CSS-CVCs and that this loss could be due to the frictional force between the surface of the CVC and the bloodstream. The objective of this study was to investigate whether the antimicrobial effect of CSS-CVCs decreases with increasing exposure time in a bloodstream model and quantitatively assay the antimicrobial effect of CSS-CVCs compared with polyurethane and antiseptic-impregnated CVCs. Methods Each CVC was subjected to 120 hours of saline flow and analyzed at intervals over 24 hours. The analyses included energy-dispersive X-ray spectroscopy, scanning electron microscopy, and optical density after a Staphylococcus aureus incubation test. Results The weight percentage of silver in the CSS-CVCs significantly decreased to 56.18% (44.10% ± 3.32%) with 48-hour catheterization and to 18.88% (14.82% ± 1.33%) with 120-hour catheterization compared with the initial weight percentage (78.50% ± 6.32%). In the S. aureus incubation test, the antibacterial function of CSS-CVCs was lost after 48 hours [3 (N/D) of OD]. Similar results were observed in a pilot clinical study using 18 CSS-CVCs. Conclusions We found that the efficacy of CSS-CVCs decreased over time and that the antibacterial function was lost after 48 hours of simulated wear-out. Therefore, antibiotic-impregnated CVCs may be a better option when longer (>48 hours) indwelling is needed.


Subject(s)
Anti-Infective Agents, Local/administration & dosage , Catheter-Related Infections/prevention & control , Central Venous Catheters , Chlorhexidine/administration & dosage , Silver Sulfadiazine/administration & dosage , Humans , Spectrometry, X-Ray Emission , Staphylococcus aureus/drug effects
3.
Acta Neurochir (Wien) ; 158(7): 1421-7, 2016 07.
Article in English | MEDLINE | ID: mdl-27177734

ABSTRACT

BACKGROUND: Dual-energy X-ray absorptiometry (DEXA) scan is an easy and cost-effective method of assessing bone mineral density (BMD). However, in patients with degenerative changes of the spine, overestimation of T-score on DEXA scan can occur despite low BMD during pedicle screw placement in spine surgery. The goal of this study is to assess BMD using Hounsfield unit (HU) measurements from computed tomography (CT) and to correlate these with DEXA-assessed T-scores in non-degenerative and degenerative patients. METHODS: This study included 80 non-degenerative and 30 degenerative patients who underwent DEXA and spine CT assessment. The HU value on the mid-body axial images of CT and DEXA-assessed T-scores were measured from the L1-4 vertebrae. RESULTS: In the non-degenerative group, HU values had a strong positive correlation with BMD and T-score, exhibiting correlation coefficients (r) greater than 0.7: the r-value (p value) between HU and T-score of the L1 vertebra was 0.701 (<0.001); 0.709 (<0.001) for L2; 0.709 (<0.001) for L3; 0.649 (<0.001) for L4; and 0.734 (<0.001) for L1-4. BMD assessed as +100 HU matched a T-score of -2.0 while +150, +200 HU matched T-scores of -1.0, 0.0. The differences were significant (p < 0.001). In the degenerative group, there was a weak positive correlation with r of approximately 0.4: the r-value (p value) was 0.300 (0.104); 0.457 (0.013); 0.433 (0.017); 0.447 (0.013) at each segment and 0.398 (0.031) for L1-4. CONCLUSIONS: HU values provide a meaningful assessment of BMD and have a strong correlation with T-score. However, in degenerative patients, the T-score tended to be higher than the actual BMD. BMD assessment using HU might be helpful in predicting real BMD in patients undergoing instrumentation surgery with degenerative changes of the spine.


Subject(s)
Absorptiometry, Photon/methods , Bone Density , Osteoporosis/diagnostic imaging , Tomography, X-Ray Computed/methods , Absorptiometry, Photon/adverse effects , Adult , Aged , Aged, 80 and over , Female , Humans , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/pathology , Middle Aged , Tomography, X-Ray Computed/adverse effects
4.
Opt Lett ; 39(23): 6675-8, 2014 Dec 01.
Article in English | MEDLINE | ID: mdl-25490650

ABSTRACT

This work reports micromachined tethered silicon oscillators (MTSOs) for endoscopic Lissajous fiber scanners. An MTSO comprises an offset silicon spring for stiffness modulation of a scanning fiber and additional mass for modulation of resonant scanning frequency in one body. MTSOs were assembled with a resonant fiber scanner and enhanced scanning reliability of the scanner by eliminating mechanical cross coupling. The fiber scanner with MTSOs was fully packaged as an endomicroscopic catheter and coupled with a conventional laparoscope and spectral domain OCT system. The endomicroscope was maneuvered with the integrated laparoscope and in vivo swine tissue OCT imaging was successfully demonstrated during open surgery. This new component serves as an important element inside an endoscopic Lissajous fiber scanner for early cancer detection or on-demand minimum lesional margin decision during noninvasive endoscopic biopsy.


Subject(s)
Endoscopy/instrumentation , Fiber Optic Technology , Microtechnology/instrumentation , Silicon , Animals , Catheters , Intestine, Small , Swine
5.
J Korean Neurosurg Soc ; 55(6): 331-6, 2014 Jun.
Article in English | MEDLINE | ID: mdl-25237428

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate the differences in sagittal spinopelvic alignment between lumbar degenerative spondylolisthesis (DSPL) and degenerative spinal stenosis (DSS). METHODS: Seventy patients with DSPL and 72 patients with DSS who were treated with lumbar interbody fusion surgery were included in this study. The following spinopelvic parameters were measured on whole spine lateral radiographs in a standing position : pelvic incidence (PI), pelvic tilt (PT), sacral slope (SS), lumbar lordosis angle (LL), L4-S1 segmental lumbar angle (SLL), thoracic kyphosis (TK), and sagittal vertical axis from the C7 plumb line (SVA). Two groups were subdivided by SVA value, respectively. Normal SVA subgroup and positive SVA subgroup were divided as SVA value (<50 mm and ≥50 mm). Spinopelvic parameters/PI ratios were assessed and compared between the groups. RESULTS: The PI of DSPL was significantly greater than that of DSS (p=0.000). The SVA of DSPL was significantly greater than that of DSS (p=0.001). In sub-group analysis between the positive (34.3%) and normal SVA (65.7%), there were significant differences in LL/PI and SLL/PI (p<0.05) in the DSPL group. In sub-group analysis between the positive (12.5%) and normal SVA (87.5%), there were significant differences in PT/PI, SS/PI, LL/PI and SLL/PI ratios (p<0.05) in the DSS group. CONCLUSION: Patients with lumbar degenerative spondylolisthesis have the propensity for sagittal imbalance and higher pelvic incidence compared with those with degenerative spinal stenosis. Sagittal imbalance in patients with DSPL is significantly correlated with the loss of lumbar lordosis, especially loss of segmental lumbar lordosis.

6.
Article in English | MEDLINE | ID: mdl-23781258

ABSTRACT

Objective. Recently, a novel circulatory system, the primo vascular system (PVS), was found in the brain ventricles and in the central canal of the spinal cord of a rat. The aim of the current work is to detect the PVS along the transverse sinuses between the cerebrum and the cerebellum of a mouse brain. Materials and Methods. The PVS in the subarachnoid space was analyzed after staining with 4',6-diamidino-2-phenylindole (DAPI) and phalloidin in order to identify the PVS. With confocal microscopy and polarization microscopy, the primo vessel underneath the sagittal sinus was examined. The primo nodes under the transversal sinuses were observed after peeling off the dura and pia maters of the brain. Results. The primo vessel underneath the superior sagittal sinus was observed and showed linear optical polarization, similarly to the rabbit and the rat cases. The primo nodes were observed under the left and the right transverse sinuses at distances of 3,763 µ m and 5,967 µ m. The average size was 155 µ m × 248 µ m. Conclusion. The observation of primo vessels was consistent with previous observations in rabbits and rats, and primo nodes under the transverse sinuses were observed for the first time in this work.

7.
J Korean Neurosurg Soc ; 53(2): 96-101, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23560173

ABSTRACT

OBJECTIVE: The purpose of this study was to analyze the differences of spinopelvic parameters between degenerative spondylolisthesis (DSPL) and isthmic spondylolisthesis (ISPL) patients. METHODS: Thirty-four patients with DSPL and 19 patients with ISPL were included in this study. Spinopelvic parameters were evaluated on whole spine X-rays in a standing position. The following spinopelvic parameters were measured : pelvic incidence (PI), sacral slope, pelvic tilt (PT), lumbar lordosis (LL), and sagittal vertical axis from C7 plumb line (SVA). The population of patients was compared with a control population of 30 normal and asymptomatic adults. RESULTS: There were statistically significant differences in LL (p=0.004) and SVA (p=0.005) between the DSPL and ISPL group. The LL of DSPL (42±13°) was significantly lower than that of the control group (48±11°; p=0.029), but that of ISPL (55±6°) was significantly greater than a control group (p=0.004). The SVA of DSPL (55±49 mm) was greater than that of a control group (<40 mm), but that of ISPL (21±22 mm) was within 40 mm as that of a control group. The PT of DSPL (24±7°) and ISPL (21±7°) was significantly greater than that of a control group (11±6°; p=0.000). CONCLUSION: Both symptomatic DSPL and ISPL patients had a greater PI than that of the asymptomatic control group. In conclusion, DSPL populations are likely to have global sagittal imbalance (high SVA) compared with ISPL populations because of the difference of lumbar lordosis between two groups.

8.
Korean J Spine ; 10(2): 65-71, 2013 Jun.
Article in English | MEDLINE | ID: mdl-24757461

ABSTRACT

OBJECTIVE: To evaluate the radiographic results of minimally invasive (MIS) anterior lumbar interbody fusion (ALIF) and transforaminal lumbar interbody fusion (TLIF). METHODS: Twelve and nineteen patients who underwent MIS-ALIF, MIS-TLIF, respectively, from 2006 to 2008 were analyzed with a minimum 24-months' follow-up. Additionally, 18 patients treated with single level open TLIF surgery in 2007 were evaluated as a comparative group. X-rays and CT images were evaluated preoperatively, postoperatively, and at the final follow-up. Fusion and subsidence rates were determined, and radiographic parameters, including lumbar lordosis angle (LLA), fused segment angle (FSA), sacral slope angle (SSA), disc height (DH), and foraminal height (FH), were analyzed. These parameters were also compared between the open and MIS-TLIF groups. RESULTS: In the MIS interbody fusion group, statistically significant increases were observed in LLA, FSA, and DH and FH between preoperative and final values. The changes in LLA, FSA, and DH were significantly increased in the MIS-ALIF group compared with the MIS-TLIF group, but SSA and FH were not significantly different. No significant differences were seen between open and MIS-TLIF except for DH. The interbody subsidence and fusion rates of the MIS groups were 12.0±4% and 96%, respectively. CONCLUSION: Radiographic results of MIS interbody fusion surgery are as favorable as those with conventional surgery regarding fusion, restoration of disc height, foraminal height, and lumbar lordosis. MIS-ALIF is more effective than MIS-TLIF for intervertebral disc height restoration and lumbar lordosis.

9.
J Korean Neurosurg Soc ; 43(1): 5-10, 2008 Jan.
Article in English | MEDLINE | ID: mdl-19096537

ABSTRACT

OBJECTIVE: To evaluate the surgical outcomes of ventral interbody grafting and anterior or posterior spinal instrumentation for the treatment of advanced spondylodiscitis in patients who had failed medical management. METHODS: A total of 28 patients were evaluated for associated medical illness, detected pathogen, level of involved spine, and perioperative complications. Radiological evaluation including the rate of bony union, segmental Cobb angle, graft- and instrumentation-related complications, and clinical outcomes by mean Frankel scale and VAS score were performed. RESULTS: There are 14 pyogenic spondylodiscitis, 6 postoperative spondylodiscitis, and 8 tuberculous spondylodiscitis. There were 21 males and 7 females. Mean age was 51 years, with a range from 18 to 77. Mean follow-up period was 10.9 months. Associated medical illnesses were 6 diabetes, 3 pulmonary tuberculosis, and 4 chronic liver diseases. Staphylococcus was the most common pathogen isolated (25%), and Mycobacterium tuberculosis was found in 18% of the patients. Operative approaches, either anterior or posterior spinal instrumentation, were done simultaneously or delayed after anterior aggressive debridement, neural decompression, and structural interbody bone grafting. All patients with neurological deficits improved after operation, except only one who died from aggravation as military tuberculosis. Mean Frankel scale was changed from 3.78+/-0.78 preoperatively to 4.78+/-0.35 at final follow up and mean VAS score was improved from 7.43+/-0.54 to 2.07+/-1.12. Solid bone fusion was obtained in all patients except only one patient who died. There was no need for prolongation of duration of antibiotics and no evidence of secondary infection owing to spinal instrumentations. CONCLUSION: According to these results, debridement and anterior column reconstruction with ventral interbody grafting and instrumentation is effective and safe in patients who had failed medical management and neurological deficits in advanced spondylodiscitis.

10.
Surg Neurol ; 69(1): 40-5; discussion 45, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18054613

ABSTRACT

BACKGROUND: We focused on the cause of hematoma expansion after admission because the volume of hematoma after S-ICH plays a crucial role in the cause of mortality and morbidity. METHODS: In a retrospective review, 51 patients with hematoma expansion of S-ICH were identified among 880 cases of S-ICH treated between 2001 and May 2006. We divided cases into 2 groups according to the time of hematoma expansion. An enlargement of hematoma within 2 weeks after hospitalization was categorized as the acute stage group and after 2 weeks was categorized as the chronic stage group. Spontaneous intracerebral hemorrhage without hematoma expansion group (100 cases) had been consecutively selected as a control group. We analyzed the risk factors of hematoma expansion in patients with S-ICH especially in the acute stage group. RESULTS: Fifty-one of 880 patients had the enlargement of hematoma (5.8%). Forty-three (84%) of 51 cases were acutely developed and 8 cases (16%) were developed chronically. On univariate analysis there were significant differences in BP within the initial 48 hours (P < .0001), GOS (P < .0001), and previously taking anticoagulant agents (P = .0053). Especially the difference in SBP and DBP within 48 hours between groups was 19 (11%) and 13 mm Hg (14%), respectively. The DBP within the initial 24 hours had a meaningful odds ratio (1.06) on logistic regression analysis. CONCLUSION: A reduction of BP by 15% (SBP < or =140 mm Hg, DBP < or =80 mm Hg) is necessary at acute stage in S-ICH.


Subject(s)
Cerebral Hemorrhage/pathology , Hematoma/pathology , Anticoagulants/adverse effects , Blood Pressure/physiology , Cerebral Hemorrhage/etiology , Female , Glasgow Outcome Scale , Hematoma/etiology , Humans , Logistic Models , Male , Middle Aged , Odds Ratio , Retrospective Studies , Risk Factors , Time Factors
11.
J Photochem Photobiol B ; 73(1-2): 43-8, 2004 Jan 23.
Article in English | MEDLINE | ID: mdl-14732250

ABSTRACT

Among the putative mechanisms, by which extremely low frequency (ELF) magnetic field (MF) may affect biological systems is that of increasing free radical life span in organisms. To test this hypothesis, we investigated whether ELF (60 Hz) MF can modulate antioxidant system in mouse brain by detecting chemiluminescence and measuring superoxide dismutase (SOD) activity in homogenates of the organ. Compared to sham exposed control group, lucigenin-initiated chemiluminescence in exposed group was not significantly increased. However, lucigenin-amplified t-butyl hydroperoxide (TBHP)-initiated brain homogenates chemiluminescence, was significantly increased in mouse exposed to 60 Hz, MF, 12 G for 3 h compared to sham exposed group. We also measured SOD activity, that plays a critical role of the antioxidant defensive system in brain. In the group exposed to 60 Hz, MF, 12 G for 3 h, brain SOD activity was significantly increased. These results suggest that 60 Hz, MF could deteriorate antioxidant defensive system by reactive oxygen species (ROS), other than superoxide radicals. Further studies are needed to identify the kind of ROS generated by the exposure to 60 Hz, MF and elucidate how MF can affect biological system in connection with oxidative stress.


Subject(s)
Antioxidants/pharmacology , Brain/metabolism , Magnetics , tert-Butylhydroperoxide/pharmacology , Animals , Brain/enzymology , Luminescent Measurements , Mice , Mice, Inbred BALB C , Superoxide Dismutase/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...