Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Musculoskelet Disord ; 25(1): 580, 2024 Jul 24.
Article in English | MEDLINE | ID: mdl-39048966

ABSTRACT

BACKGROUND: The calcar of the proximal humerus is a fundamental structure for medial humeral column support. This study aimed to assess the outcome of osteosynthesis across cases of unstable proximal humerus fractures (PHFs) with medial calcar comminution, following treatment with a PHILOS locking plate and medial support screw (MSS). METHODS: Between January 2010 and December 2018, we retrospectively analyzed the outcomes of 121 cases of osteosynthesis for PHFs with medial column disruption. For the medial support, at least one oblique screw was inserted within 5 mm of the subchondral bone in the inferomedial quadrant of the humeral head. All patients were categorized into two groups: 26 patients in the single MSS group, and 95 in the multiple MSS group. Follow-up after at least an year involved clinical and radiographic outcome evaluations, and correspondingly measuring the Constant-Murley score, University of California, Los Angeles (UCLA) shoulder scale, pain visual analogue scale (VAS), major complications, neck-shaft angle (NSA), humeral head height (HHH), and the eventual time to bone union. Risk factors for the major complications were assessed by multivariate logistic regression analyses. RESULTS: The cohort's mean age was 64.4 ± 15.4 years, and the mean follow-up duration was 19.5 ± 7.6 months. At the final follow-up, between the single MSS and multiple MSS groups, no significant differences in the Constant-Murley score (p = 0.367), UCLA score (p = 0.558), VAS (p = 0.571), time to bone union (p = 0.621), NSA loss (p = 0.424), and HHH loss (p = 0.364) were observed. The incidence of complications (p = 0.446) based on the number of MSS were not significantly different. The initial insufficient reduction after surgery (of NSA < 125°) was found to be a significant risk factor for post-surgical complications. CONCLUSIONS: To treat unstable PHFs, the use of at least one MSS along with a locking plate system is sufficient to achieve satisfactory outcomes. Successful operative treatment using a locking plate for PHF treatment is inherent in anatomical fracture reduction, coupled with medial column support.


Subject(s)
Bone Plates , Bone Screws , Fracture Fixation, Internal , Shoulder Fractures , Humans , Shoulder Fractures/surgery , Shoulder Fractures/diagnostic imaging , Male , Female , Middle Aged , Retrospective Studies , Aged , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Treatment Outcome , Aged, 80 and over , Follow-Up Studies , Adult
2.
BMC Surg ; 24(1): 125, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38664803

ABSTRACT

BACKGROUND: The ideal treatment of terrble triad injuries and whether fixation of coronoid process fractures is needed or not are still debated. Therefore, we aimed to investigate if terrible triad injuries necessitate coronoid fracture fixation and evaluate if non-fixation treatments have similar efficacies and outcomes as fixation-treatments in cases of terrible triad injuries. METHODS: From August 2011 to July 2020, 23 patients with acute terrible triad injuries without involvement of the anteromedial facet of the coronoid process were included to evaluate the postoperative clinical and radiological outcomes (minimum follow-up of 20 months). According to the preoperative height loss evaluation of the coronoid process and an intraoperative elbow stability test, seven patients underwent coronoid fracture fixation, and the other eight patients were treated conservatively. The elbow range of motion (ROM), Mayo Elbow Performance Score (MEPS), and modified Broberg-Morrey score were evaluated at the last follow-up. In addition, plain radiographs were reviewed to evaluate joint congruency, fracture union, heterotopic ossification, and the development of arthritic changes. RESULTS: At the last follow-up, the mean arcs of flexion-extension and supination-pronation values were 118.2° and 146.8° in the fixation group and 122.5° and 151.3° in the non-fixation group, respectively. The mean MEPSs were 96.4 in the fixation group (excellent, nine cases; good, tow cases) and 96.7 in the non-fixation group (excellent, ten cases; good, two cases). The mean modified Broberg-Morrey scores were 94.0 in the fixation group (excellent, sevev cases; good, four cases) and 94.0 in the non-fixation group (excellent, ten cases; good, tow cases). No statistically significant differences in clinical scores and ROM were identified between the two groups. However, the non-fixation group showed a significantly lower height loss of the coronoid process than the fixation group (36.3% versus 54.5%). CONCLUSIONS: There were no significant differences in clinical outcomes between the fixation and non-fixation groups in terrible triad injuries.


Subject(s)
Elbow Injuries , Elbow Joint , Fracture Fixation, Internal , Range of Motion, Articular , Ulna Fractures , Humans , Male , Adult , Female , Ulna Fractures/surgery , Ulna Fractures/diagnostic imaging , Middle Aged , Fracture Fixation, Internal/methods , Range of Motion, Articular/physiology , Elbow Joint/diagnostic imaging , Elbow Joint/physiopathology , Elbow Joint/surgery , Retrospective Studies , Young Adult , Treatment Outcome , Follow-Up Studies
3.
J Clin Med ; 13(8)2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38673473

ABSTRACT

Treatment of a comminuted proximal humerus fracture (PHF) in elderly patients with severe osteoporosis is challenging, often leading to arthroplasty (such as hemiarthroplasty or reverse shoulder arthroplasty) as the treatment of choice. However, arthroplasty does not always guarantee favorable outcomes. In contrast, the use of intramedullary fibular strut allografts provides additional reduction stability during locking plate fixation; however, to our knowledge, there is limited literature on the use of fibular strut allografts, including the fibular head. Here we aim to report the advantages of using a fibular strut containing the fibular head in severe osteoporotic PHFs. We present the case of an 88-year-old female patient with severe osteoporosis diagnosed with a left PHF accompanied by severe metaphyseal comminution following a fall from a chair. Rather than shoulder arthroplasty, we performed osteosynthesis using a fibular strut allograft containing the fibular head. At the one-year follow-up after surgery, we observed excellent bony union and a favorable functional outcome without major complications, such as reduction loss. The novel use of a fibular strut allograft containing the fibular head could be promising for PHFs with severe metaphyseal comminution, potentially avoiding the need for arthroplasty.

SELECTION OF CITATIONS
SEARCH DETAIL