Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Publication year range
1.
Clin Chim Acta ; 528: 56-64, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35092724

ABSTRACT

BACKGROUND: Automated, technically simple analytical methods offering objective results are highly valued in clinical laboratories. Kappa free light chains (KFLC) in cerebrospinal fluid (CSF) are promising multiple sclerosis (MS) biomarkers, particularly kappa (K) index. METHODS: KFLC were determined in CSF and serum samples of patients diagnosed with MS, clinically/radiologically isolated syndrome (N, 39), and controls (N, 152; inflammatory and non-inflammatory neurological disorders). Diagnostic performance of several KFLC parameters, previously determined oligoclonal band (OCB) testing, and IgG index, was assessed. A K index decision threshold for sample screening was identified and reduction in performed OCB analyses estimated accordingly. RESULTS: Higher KFLC parameters were detected in the MS group and K index performed best among them (AUC 0.92). At a 7.25 cut-off it showed better sensitivity (85% vs. 77%) though less specificity (88% vs. 91%) than OCBs. Comparatively, IgG index's performance was inferior (AUC 0.83). A decision K index threshold of 2.55 (97% sensitivity) would reduce OCB testing by 52% in the studied population. CONCLUSIONS: The proposed 7.25 cut-off could assist MS diagnostics and identify some false negative cases from OCB studies. Sequential algorithms using K index for the decision to perform OCB detection would improve laboratory efficiency and substantially reduce costs.


Subject(s)
Multiple Sclerosis , Biomarkers , Humans , Immunoglobulin kappa-Chains/cerebrospinal fluid , Laboratories, Clinical , Multiple Sclerosis/cerebrospinal fluid , Oligoclonal Bands/cerebrospinal fluid
2.
Rev. Inst. Adolfo Lutz ; 41(1): e36993, jun 30, 1981. ilus
Article in Portuguese | LILACS, CONASS, Coleciona SUS, Sec. Est. Saúde SP, SESSP-IALPROD, Sec. Est. Saúde SP, SESSP-IALACERVO | ID: lil-11826

ABSTRACT

Foi feita uma avaliação do biiodeto de mercúrio (HgI 2 ) como preservativo de material biológico, tendo em vista a sua capacidade de conservação por longo tempo, e a propriedade de não aglutinar partículas. Ao sedimento obtido de 400 amostras de fezes acrescentou-se o iodo-mercurato de potássio a 0,20/0, preparado com formol, álcool e soluto fisiológico, na proporção de três partes de conservante para uma parte de sedimento. Numa segunda etapa empregou-se o conservante a 0,1%, preparado com benzeno, álcool, e soluto fisiológico isotônico. Como controles utilizaram-se os conservantes de Railliet & Henry, o MIF (mertiolato, iodo e formol) e o de Schaudinn. Os resultados avaliados após seis meses revelaram que o iodo-mercurato de potássio a 0,2% (primeira fórmula) preservou adequadamente cistos e trofozoítos de protozoários, além de ovos e exemplares adultos de helmintos, com exceção dos ovos de Humenolepis nana e Hymenolepis diminuta, que se apresentaram mais bem conservados usando a segunda fórmula. Resultados semelhantes obtiveram-se com os controles, evidenciando-se o iodo-mercurato de potássio pela propriedade de não aglutinar as partículas de fezes (AU).


Subject(s)
Preservation, Biological , Feces , Mercury
SELECTION OF CITATIONS
SEARCH DETAIL
...