Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 103
Filter
1.
Expert Rev Med Devices ; : 1-8, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38884608

ABSTRACT

BACKGROUND: Autologous bone dust can be filled in bone defects to promote effective bone healing but typically it is lost when using suction during surgery. The aim of this study was to develop a novel bone collector that can be used to collect bone chips/dust of varying sizes without changing current surgical procedures. RESEARCH DESIGN AND METHODS: This collector was designed to connect to a surgical continuous suction system and comprised a plate filter with a 3 mm hole and featured a taper filter with a mesh size of 0.27 mm for the separation and collection of both coarse and fine bone chips/dust. The bone collector was manufactured using nylon 3D printing and plastic injection with biocompatible materials. RESULTS: The bone collector functional test revealed high bone chip collection efficiency (93%) with automatic size separation function. Low (3.42%) filtration errors showed that most of the water can be drained smoothly from the bone collector. In clinical usability testing, bone collectors can provide functions demonstrated in in vivo spinal fusion and femoral fracture surgeries with different bone grafting size requirements. CONCLUSIONS: The novel bone collector has been validated as a viable and effective surgical device, offering surgeons an additional option to enhance patient outcomes.

2.
J Orthop Surg Res ; 19(1): 299, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755635

ABSTRACT

BACKGROUND: This study aims to evaluate the optimal ratio of synthetic bone graft (SBG) material and platelet rich fibrin (PRF) mixed in a metal 3D-printed implant to enhance bone regeneration. METHODS: Specialized titanium hollow implants (5 mm in diameter and 6 mm in height for rabbit; 6 mm in diameter and 5 mm in height for pig) were designed and manufactured using 3D printing technology. The implants were divided into three groups and filled with different bone graft combinations, namely (1) SBG alone; (2) PRF to SBG in 1:1 ratio; (3) PRF to SBG in 2:1 ratio. These three groups were replicated tightly into each bone defect in distal femurs of rabbits (nine implants, n = 3) and femoral shafts of pigs (fifteen implants, n = 5). Animal tissue sections were obtained after euthanasia at the 8th postoperative week. The rabbit specimens were stained with analine blue, while the pig specimens were stained with Masson-Goldner's trichrome stain to perform histologically examination. All titanium hollow implants were well anchored, except in fracture specimens (three in the rabbit and one fracture in the pig). RESULT: Rabbit specimens under analine blue staining showed that collagen tissue increased by about 20% and 40% in the 1:1 ratio group and the 2:1 ratio group, respectively. Masson-Goldner's trichrome stain results showed that new bone growth increased by 32% in the 1:1 ratio PRF to SBG, while - 8% in the 2:1 ratio group. CONCLUSION: This study demonstrated that placing a 1:1 ratio combination of PRF and SBG in a stabilized titanium 3D printed implant resulted in an optimal increase in bone growth.


Subject(s)
Bone Regeneration , Platelet-Rich Fibrin , Printing, Three-Dimensional , Titanium , Animals , Rabbits , Bone Regeneration/drug effects , Bone Regeneration/physiology , Swine , Femur/surgery , Bone Substitutes , Bone Transplantation/methods , Prostheses and Implants
3.
Int J Bioprint ; 9(5): 772, 2023.
Article in English | MEDLINE | ID: mdl-37457946

ABSTRACT

This study aimed to design an anatomical contour metal three-dimensional (3D)-printed oblique lateral lumbar interbody fusion (OLIF) cage with porous (lattices) structure and embedded screw fixation to enhance bone ingrowth to reduce the risk of cage subsidence and avoid the stress-shielding effect. Finite element (FE) analysis and weight topology optimization (WTO) were used to optimize the structural design of the OLIF cage based on the anatomical contour morphology of patients with osteoporosis. Two oblique embedded fixation screws and lattice design with 65% porosity and average pore size of 750 µm were equipped with the cage structure. The cage was fabricated via metal 3D printing, and static/dynamic compression and compressive-shear tests were performed in accordance with the ASTM F2077-14 standard to evaluate its mechanical resistance. On FE analysis, the OLIF cage with embedded screw model had the most stability, lowest stress values on the endplate, and uniform stress distribution versus standalone cage and fixed with lateral plate under extension, lateral flexion, and rotation. The fatigue test showed that the stiffnesses/endurance limits (pass 5 million dynamic test) were 16,658 N/mm/6000 N for axial load and 19,643 N/mm/2700 N for compression shear. In conclusion, an OLIF cage with embedded fixation screws can be designed by integrating FE and WTO analysis based on the statistical results of endplate morphology. This improves the stability of the OLIF cage to decrease endplate destruction. The complex contour and lattice design of the OLIF cage need to be manufactured via metal 3D printing; the dynamic axial compression and compressive-shear strengths are greater than that of the U.S. Food and Drug Administration (FDA) standard.

4.
J Orthop Sci ; 2023 Jun 29.
Article in English | MEDLINE | ID: mdl-37393110

ABSTRACT

BACKGROUND: Fixing the posterolateral fragments of tibial plateau fractures has been challenging owing to potential neurovascular injuries and fibular head blocks. Several surgical approaches and fixation techniques have been reported, with distinct limitations. We propose a novel lateral tibia plateau hook plate system and compare its biomechanical stability with other fixation methods. METHODS: Twenty-four synthetic tibia models were simulated to present posterolateral tibial plateau fractures. These models were randomly assigned to three groups. Group A models were fixed with the lateral tibia plateau hook plate system, Group B with variable-angle anterolateral locking compression plates, and Group C with direct posterior buttress plates. The models' biomechanical stability was evaluated using static (gradually increased axial compressive loads) and fatigue (cyclically loaded from 100 to 600 N for 2000 cycles each) tests. RESULTS: Groups A and C models exhibited comparable axial stiffness, subsidence load, failure load, and displacement in the static test. Group A model exhibited higher subsidence and failure loads than Group B model. Groups A and C models exhibited comparable displacement at 100 N cyclic loading in the fatigue test. Group C model was more stable at higher loads. Group C model endured the highest subsidence cycle numbers, followed by Groups A and B models. CONCLUSIONS: The lateral tibia plateau hook plate system provided similar static biomechanical stability as the direct posterior buttress plates and comparable dynamic stability under limited axial loading. This system is a potential posterolateral treatment choice owing to its convenience and safety, in treating tibia plateau fractures.

5.
Bioengineering (Basel) ; 10(6)2023 Jun 05.
Article in English | MEDLINE | ID: mdl-37370619

ABSTRACT

Iliac vein compression syndrome (IVCS, or May-Thurner syndrome) occurs due to the compression of the left common iliac vein between the lumbar spine and right common iliac artery. Because most patients with compression are asymptomatic, the syndrome is difficult to diagnose based on the degree of anatomical compression. In this study, we investigated how the tilt angle of the left common iliac vein affects the flow patterns in the compressed blood vessel using three-dimensional computational fluid dynamic (CFD) simulations to determine the flow fields generated after compression sites. A patient-specific iliac venous CFD model was created to verify the boundary conditions and hemodynamic parameter set in this study. Thirty-one patient-specific CFD models with various iliac venous angles were developed using computed tomography (CT) angiograms. The angles between the right or left common iliac vein and inferior vena cava at the confluence level of the common iliac vein were defined as α1 and α2. Flow fields and vortex locations after compression were calculated and compared according to the tilt angle of the veins. Our results showed that α2 affected the incidence of flow field disturbance. At α2 angles greater than 60 degrees, the incidence rate of blood flow disturbance was 90%. In addition, when α2 and α1 + α2 angles were used as indicators, significant differences in tilt angle were found between veins with laminar, transitional, and turbulent flow (p < 0.05). Using this mathematical simulation, we concluded that the tilt angle of the left common iliac vein can be used as an auxiliary indicator to determine IVCS and its severity, and as a reference for clinical decision making.

6.
Int J Bioprint ; 9(3): 697, 2023.
Article in English | MEDLINE | ID: mdl-37273986

ABSTRACT

In this study, we designed and manufactured a posterior lumbar interbody fusion cage for osteoporosis patients using 3D-printing. The cage structure conforms to the anatomical endplate's curved surface for stress transmission and internal lattice design for bone growth. Finite element (FE) analysis and weight topology optimization under different lumbar spine activity ratios were integrated to design the curved surface (CS-type) cage using the endplate surface morphology statistical results from the osteoporosis patients. The CS-type and plate (P-type) cage biomechanical behaviors under different daily activities were compared by performing non-linear FE analysis. A gyroid lattice with 0.25 spiral wall thickness was then designed in the internal cavity of the CS-type cage. The CS-cage was manufactured using metal 3D printing to conduct in vitro biomechanical tests. The FE analysis result showed that the maximum stress values at the inferior L3 and superior L4 endplates under all daily activities for the P-type cage implantation model were all higher than those for the CS-type cage. Fracture might occur in the P-type cage because the maximum stresses found in the endplates exceeded its ultimate strength (about 10 MPa) under flexion, torsion and bending loads. The yield load and stiffness of our designed CS-type cage fall into the optional acceptance criteria for the ISO 23089 standard under all load conditions. This study approved a posterior lumbar interbody fusion cage designed to have osteoporosis anatomical curved surface with internal lattice that can achieve appropriate structural strength, better stress transmission between the endplate and cage, and biomechanically tested strength that meets the standard requirements for marketed cages.

7.
Biomed Eng Online ; 22(1): 42, 2023 May 10.
Article in English | MEDLINE | ID: mdl-37161417

ABSTRACT

BACKGROUND: Although minimally invasive surgeries have gained popularity in many orthopaedic fields, minimally invasive approaches for diaphyseal clavicular fracture have not been widely performed, which is attributed to difficulties in performing a closed reduction of fracture deformities of a curved bone in a three-dimensional space. The goal of this study was to investigate the radiographic parameters of fracture deformities in a three-dimensional space and to identify the risk factors for deformities. METHODS: The computed tomography images of 100 patients who sustained a clavicle fracture were included. Five parameters were used to analyze the deformities: change in clavicle length, fracture displacement, and fragment rotation around the X, Y, Z axes. The change in length was assessed using the length of the endpoint line. The displacement was assessed using the distance between the fracture midpoints. The rotation deformities were assessed using the Euler angles. The correlation between the parameters was evaluated with the Pearson correlation coefficient. The risk factors were evaluated using univariable analysis and multiple regression analysis. RESULTS: The average change in length was - 5.3 ± 8.3 mm. The displacement was 11.8 ± 7.1 mm. The Euler angles in the Z-Y-X sequences were -1 ± 8, 1 ± 8, and - 8 ± 13 degrees. The correlation coefficient between the change in length and the displacement was - 0.724 (p < 0.001). The variables found to increase the risk of shortening and displacement were right-sided fracture (p = 0.037), male sex (p = 0.015), and multifragmentary type (p = 0.020). The variables found to increase the risk of rotation deformity were the number of rib fractures (p = 0.001) and scapula fracture (p = 0.025). CONCLUSIONS: There was a strong correlation between shortening and displacement. The magnitude of anterorotation around the X axis was greater than the magnitude of retraction around the Z axis and depression around the Y axis. The risk factors for shortening and displacement included right-sided fracture, male sex, and multifragmentary type. The risk factor for retraction around the Z axis was the number of rib fractures, and the risk factor for depression around the Y axis was scapula fracture. These results could be useful adjuncts in guiding minimally invasive surgical planning for diaphyseal clavicular fractures.


Subject(s)
Orthopedics , Rib Fractures , Shoulder Fractures , Thoracic Injuries , Humans , Male , Clavicle/diagnostic imaging , Risk Factors
8.
Spine J ; 23(5): 766-779, 2023 05.
Article in English | MEDLINE | ID: mdl-36623736

ABSTRACT

BACKGROUND CONTEXT: Titanium implantable vertebral augmentation device (TIVAD) are regarded as having potential in the treatment of vertebral compression fractures (VCFs). However, improper design in current TIVADs results in the inability to effectively restore VCF height and maintain stability. There is still an unmet clinical need for improvement. PURPOSE: The authors tested a newly developed a TIVAD (Tri-blade fixed system) that can provide enough endplate collapse support to restore the vertebral body height in a safe retraction mechanism for VCFs using minimally invasive surgery (MIS). STUDY DESIGN: The performed biomechanical tests included blade expansion force, lifetime of cement embedded and vertebral height restoration efficiency of porcine osteoporosis VCFs for its feasibility. METHODS: A cylinder with 3 surface cuts that form blades that can be expanded into a conical space was designed (Tri-blade fixed system). The 3 blades can be expanded outward with angles between blades as 105°/ 105°/150° for lower left/lower right/upper arms, respectively that reach 15mm in height and 14.8 mm in width. A frame was specifically designed to measure the contact force using force sensing resistors during blade expansion. The Tri-blade fixed system was embedded into a cement block to perform fatigue testing under 2000N pressure (5*106 cycles) for understanding the device lifetime limitation. The Tri-blade system was then inserted into porcine osteoporosis VCFs to examine the vertebral height restoration efficiency. RESULTS: The average maximum contact force for the top, bottom left and right blades were 299.0N, 283.5N and 279.3N, respectively with uniformly outward expansion forces. The fatigue test found that there were no obvious cracks or damage to the cement block. The porcine osteoporosis vertebral body at the anterior, middle, and posterior heights can be restored to 21.9%, 12.6% and 6.4%, respectively. CONCLUSIONS: This study developed a novel TIVAD with conical shape that can provide a more stable structure with sufficient/uniform expansion force, passing the fatigue test with bone cement and high effective in vertebral height restoration tests for porcine osteoporosis VCFs. CLINICAL SIGNIFICANCE: The new 3D Tri-blade TIVAD may offer a new treatment option for VCFs.


Subject(s)
Fractures, Compression , Osteoporosis , Spinal Fractures , Animals , Swine , Spinal Fractures/surgery , Titanium , Fractures, Compression/surgery , Spine/surgery , Osteoporosis/surgery , Osteoporosis/drug therapy , Bone Cements/therapeutic use , Treatment Outcome
9.
J Shoulder Elbow Surg ; 32(1): 192-200, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36167290

ABSTRACT

BACKGROUND: Previous researchers used transverse fractures centered over the midpoint of the clavicle as the diaphyseal clavicular fracture models. However, as a result of shear stress concentration in sigmoid-shaped structures, most diaphyseal clavicular fractures have coronal fracture edges and are located distal to the midpoint. The purpose of this study was to quantify the morphology and utilize these parameters to establish clinically relevant fracture models. METHODS: The computed tomographic DICOM data of 100 consecutive patients were included. We investigated the morphologic characteristics of the fracture edges after virtual fracture reduction. The fracture orientation was determined based on the normal vectors of the best-fit plane of the fracture edges. The fracture location was measured by the extreme points of the edges. The fracture configuration was evaluated using fracture maps. RESULTS: There were 28 simple, 43 wedge, and 29 multifragmentary types. Coronal oriented fracture edges accounted for more than 70% of the simple, wedge, and multifragmentary types. The most proximal point of the proximal edge was located at 46.7% (42.0%-56.5%), 47.6% (42.5%-50.1%), and 46.3% (42.0%-49.3%) of the endpoint line in the simple, wedge, and multifragmentary types, respectively (P = .548). The most distal point of the distal edge was located at 72.2% (68.4%-75.0%), 73.2% (69.5%-76.9%), and 74.0% (69.6%-77.1%) of the endpoint line (P = .353). The longest proximal main fragments occurred in the simple types at 71.9% (66.3%-75.4%) of the endpoint line (P < .001), and the shortest distal main fragments occurred in the multifragmentary types at 55.8% (49.8%-59.3%) of the endpoint line (P = .001). The heatmaps showed a high concentration of anteriorly distributed wedge fragments (88%; n = 38/43) and coronally distributed multifragmentary fragments (62%; n = 18/29). CONCLUSIONS: We showed that typical diaphyseal clavicular fractures have coronal fracture edges and are located within the distal half of the diaphyseal segment. The fractured fragments were initiated anteriorly in the wedge types and then propagated coronally in the multifragmentary types. The features of these fracture edges could be useful in designing osteotomy models and provide different perspectives of anterior and superior plating techniques.


Subject(s)
Clavicle , Fractures, Bone , Humans , Clavicle/diagnostic imaging , Clavicle/surgery , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Diaphyses/diagnostic imaging , Fracture Fixation, Internal/methods , Osteotomy
10.
Int J Bioprint ; 8(4): 608, 2022.
Article in English | MEDLINE | ID: mdl-36404776

ABSTRACT

The aim of this study is to develop a titanium three-dimensional (3D) printing novel hybrid suture anchor (HSA) with wing structure mechanism which can be opened to provide better holding power for surrounding osteoporotic bone. A screw-type anchor (5.5-mm diameter and 16-mm length) was designed with wing mechanism as well as micro dual-thread in the outer cortex bone contact area and macro single-thread in the anchor body. Both side wings can be opened by an internal screw to provide better bone holding power. The suture anchor and internal screw were manufactured using Ti6Al4V 3D printing and traditional machining, respectively. Static pullout and after dynamic 300-cyclic load (150 N) pullout tests for HSA with or without the wing open and commercial solid anchor (CSA) were performed (n = 5) in severely osteoporotic bone and osteoporotic bone to evaluate failure strengths. Comparison of histomorphometrical evaluation was performed through in vivo pig implantation of HSAs with the wing open and CSAs. The failure strengths of HSA with or without the wing open were 2.50/1.95- and 2.46/2.17-fold higher than those of CSA for static and after dynamic load pullout tests in severely osteoporotic bone, respectively. Corresponding values for static and after dynamic load pullout tests were 1.81/1.54- and 1.77/1.62-fold in osteoporotic bone, respectively. Histomorphometrical evaluation revealed that the effects of new bone ingrowth along the anchor contour for CSA and HSA were both approximately 20% with no significant difference. A novel HSA with wing mechanism was developed using 3D printing and the opened wing mechanism can be used to increase bone holding power for osteoporosis when necessary. Better failure strength of HSA than CSA under static and after dynamic load pullout tests and equivalence of bone ingrowth along the anchor contours confirmed the feasibility of the novel HSA.

11.
Int J Bioprint ; 8(3): 579, 2022.
Article in English | MEDLINE | ID: mdl-36105127

ABSTRACT

In this study, we developed a modularized proximal interphalangeal (PIP) joint implant that closely resembles the anatomical bone articular surface and cavity contour based on computed tomography (CT) image reconstruction. Clouds of points of 48 groups reconstructed phalanx articular surfaces of CT images, including the index, middle, ring, and little fingers, were obtained and fitted to obtain the articular surface using iterative closest points algorithm. Elliptical-cone stems, including the length, the major and minor axis at the stem metaphyseal/diaphyseal side for the proximal and middle phalanxes, were designed. The resurfacing PIP joint implant components included the bi-condylar surface for the proximal phalanx with elliptical-cone stem, ultra-high molecular weight polyethylene bi-concave articular surface for middle phalanx with hook mechanism, and the middle phalanx with elliptical-cone stem. Nine sets of modularized designs were made to meet the needs of clinical requirements and the weakness structure from the nine sets, that is, the worst structure case combination was defined and manufactured using titanium alloy three-dimensional (3D) printing. Biomechanical tests including anti-loosening pull-out strength for the proximal phalanx, elliptical-cone stem, and articular surface connection strength for the middle phalanx, and static/dynamic (25000 cycles) dislocation tests under three daily activity loads for the PIP joint implant were performed to evaluate the stability and anti-dislocation capability. Our experimental results showed that the pull-out force for the proximal phalanx implant was 727.8N. The connection force for the hook mechanism to cone stem of the middle phalanx was 49.9N and the hook mechanism was broken instead of stem pull out from the middle phalanx. The static dislocation forces/dynamic fatigue limits (pass 25000 cyclic load) of daily activities for piano-playing, pen-writing, and can-opening were 525.3N/262.5N, 316.0N/158N, and 115.0N/92N, respectively, and were higher than general corresponding acceptable forces of 19N, 17N, and 45N from the literatures. In conclusion, our developed modularized PIP joint implant with anatomical articular surface and elliptical-cone stem manufactured by titanium alloy 3D printing could provide enough joint stability and the ability to prevent dislocation.

12.
Reprod Biomed Online ; 45(3): 491-500, 2022 09.
Article in English | MEDLINE | ID: mdl-35843780

ABSTRACT

RESEARCH QUESTION: What factors affect the incidence of mosaic embryos resulting from assisted reproductive technology? DESIGN: A retrospective analysis of data from preimplantation genetic testing for aneuploidies in 544 couples was conducted using data from an electronic medical record database. RESULTS: Of 1910 embryos studied, 127 (6.6%) were mosaic. In multivariable logistic regression analysis, mosaicism incidence increased in embryos from IVF versus intracytoplasmic sperm injection (ICSI) (odds ratio [OR] 4.560, 95% confidence interval [CI] 2.800-7.424, P < 0.001), and in embryos from abnormal versus normal semen (OR 3.496, 95% CI 2.455-4.979, P < 0.001). Embryos tested using SurePlex 24Sure had lower mosaicism percentages than those tested using MALBAC-NGS and PicoPLEX GenetiSure (OR 2.726, 95% CI 1.532-4.852, P = 0.001; OR 2.389, 95% CI 1.537-3.711, P < 0.001, respectively). CONCLUSIONS: Semen quality, fertilization method and detection system are independent factors associated with embryonic mosaicism.


Subject(s)
Mosaicism , Preimplantation Diagnosis , Aneuploidy , Blastocyst , Female , Fertilization in Vitro , Genetic Testing/methods , Humans , Male , Pregnancy , Preimplantation Diagnosis/methods , Retrospective Studies , Semen , Semen Analysis
13.
Curr Med Imaging ; 18(11): 1195-1203, 2022.
Article in English | MEDLINE | ID: mdl-35379138

ABSTRACT

BACKGROUND: Hounsfield Units (HU) values derived from Computerized Tomography (CT) have been used in the diagnosis of osteoporosis in the lumbar spine. OBJECTIVE: This study aimed to identify anatomical dimensions of lumbar vertebrae on CT images, which were different between older normal, osteopenic, and osteoporotic subjects. METHODS: This prospective pilot study enrolled 79 older adults. Based on CT measurements of lumbar vertebrae in HU, participants were classified into three groups: normal (HU > 109), osteopenia (HU: 94-108), and osteoporosis (HU < 93). Altogether, 42 anatomical variables of lumbar vertebrae, L2, L3, L4, and L5, were measured in each participant by CT, including 24 parameters measurable by MRI or plain X-ray and 18 parameters measurable by MRI only. RESULTS: Among the morphological measurements also measurable by MRI and plain X-ray, the length upper curve, 50% and 75% of L5, length upper with the cortex of L4, length center of the cortex of L3, as well as width upper curve 75% of L2, were significantly different between the three groups (p= 0.008, 0.007, 0.035, 0.036, and 0.003 respectively). Among the morphological measurements also measurable by MRI, only the width upper cortex 75% of L5 and the width lower cortex 25% of L3, were significantly different between the three groups (p= 0.031 and 0.020, respectively). CONCLUSION: Seven CT morphological measurements may be used as "reference standard" CT measurements for preliminarily diagnosing osteoporosis and osteopenia in older adults.


Subject(s)
Bone Diseases, Metabolic , Osteoporosis , Absorptiometry, Photon/methods , Aged , Bone Density , Bone Diseases, Metabolic/diagnostic imaging , Humans , Lumbar Vertebrae/diagnostic imaging , Osteoporosis/diagnostic imaging , Pilot Projects , Prospective Studies , Tomography, X-Ray Computed/methods
14.
Int J Bioprint ; 8(1): 437, 2022.
Article in English | MEDLINE | ID: mdl-35187275

ABSTRACT

This study developed design criterion for patient-specific reconstructed implants with appearance consideration and structural optimization of various mandibular continuity defects. The different mandible continuity defects include C (from left to right canines), B (from 1st premolar to 3rd molar), and A (from 3rd molar to ramus) segments defined based on the mandible image. The finite element (FE) analysis and weighted topology optimization methods were combined to design internal support beam structures within different reconstructed implants with corresponding occlusal conditions. Five continuity mandibular defects (single B/C/A+B and combination of B+C and B+C+B segments) were restored using additive manufacturing (AM) reconstructed implant and bone plate to confirm reasonable design criterion through biomechanical fatigue testing. The worst mandible strength was filtered based on the material mechanics and results from segmental bone length, thickness, and height statistics from the established database containing mandible images of 105 patients. The weighted optimization analysis results indicated that the sizes and positions of internal supporting beams within the reconstructed C, B, and A+B implants can be defined parametrically through corresponding segmental bone length, width, and height. The FE analysis found that the weight variation percentage between the parametric designed implants and original core solid implants in the C, B, and A+B was reduced by 54.3%, 63.7%, and 69.7%, respectively. The maximum stress values of the reconstructed implant and the remaining bone were not obviously reduced but the stress values were far lower than the material ultimate strength. The biomechanical fatigue testing indicated that all cases using the AM reconstructed implant could pass the 250,000 dynamic load. However, condyle head, bone plate fracture, and bone screw loosening could be found in cases using bone plates. This study developed a design criterion for patient-specific reconstructed implants for various mandibular continuity defects applicable for AM to further clinical use.

15.
Materials (Basel) ; 14(20)2021 Oct 18.
Article in English | MEDLINE | ID: mdl-34683780

ABSTRACT

This study compares the absolute and relative stabilities of a novel hybrid dorsal double plating (HDDP) to the often-used dorsal double plating (DDP) under distal radius fracture. The "Y" shape profile with 1.6 mm HDDP thickness was obtained by combining weighted topology optimization and finite element (FE) analysis and fabricated using Ti6Al4V alloy to perform the experimental tests. Static and fatigue four-point bending testing for HDDP and straight L-plate DDP was carried out to obtain the corresponding proof load, strength, and stiffness and the endurance limit (passed at 1 × 106 load cycles) based on the ASTM F382 testing protocol. Biomechanical fatigue tests were performed for HDDP and commercial DDP systems fixed on the composite Sawbone under physiological loads with axial loading, bending, and torsion to understand the relative stability in a standardized AO OTA 2R3A3.1 fracture model. The static four-point bending results showed that the corresponding average proof load values for HDDP and DDPs were 109.22 N and 47.36 N, that the bending strengths were 1911.29 N/mm and 1183.93 N/mm, and that the bending stiffnesses were 42.85 N/mm and 4.85 N/mm, respectively. The proof load, bending strength and bending stiffness of the HDDPs were all significantly higher than those of DDPs. The HDDP failure patterns were found around the fourth locking screw hole from the proximal site, while slight plate bending deformations without breaks were found for DDP. The endurance limit was 76.50 N (equal to torque 1338.75 N/mm) for HDDP and 37.89 N (equal to torque 947.20 N/mm) for DDP. The biomechanical fatigue test indicated that displacements under axial load, bending, and torsion showed no significant differences between the HDDP and DDP groups. This study concluded that the mechanical strength and endurance limit of the HDDP was superior to a commercial DDP straight plate in the four-point bending test. The stabilities on the artificial radius fractured system were equivalent for novel HDDP and commercial DDP under physiological loads in biomechanical fatigue tests.

16.
J Pers Med ; 11(7)2021 Jul 11.
Article in English | MEDLINE | ID: mdl-34357120

ABSTRACT

Personalized tongue pressure (TP) training focuses on improving swallowing. This study aims to establish the TP values of different age levels and compare changes between different swallowing status among community-dwelling elders. In this cross-sectional study, 1000 participants, aged 60 years old and above, were recruited from community care centers. All participants were classified into non chewing and/or swallowing difficulties (NCSD) and with chewing and/or swallowing difficulties (CSD) groups and their diseases and dieting status were recorded using a structured questionnaire. A disposable oral probe was used to measure TP by asking participants to compress it against the hard palate with maximum voluntary effort. Among 1000 elders, 63.10% had CSD and their TP (from 31.76 to 18.20 kPa) was lower than the NCSD group (from 33.56 to 24.51 kPa). Both groups showed the same tendency for TP decline with increasing age. Decline of TP makes CSD elderly have a poor appetite, eat a soft or liquid diet, and take longer to eat a meal (all p < 0.050). The secondary risk factor dominating TP decline for NCSD and CSD elders is having an education level less than primary school and an abnormal eating assessment, respectively. Our results demonstrated that TP decline has a significant relationship with age changes. Education level and an abnormal eating assessment score are closely associated with TP decline. A series of TP values can be used as a reference indicator of personalized medicine during the aging process among community-dwelling older adults.

17.
Diagnostics (Basel) ; 11(3)2021 Mar 10.
Article in English | MEDLINE | ID: mdl-33801947

ABSTRACT

This study developed a novel chair-side tongue pressure (TP) measuring instrument with a disposable positioning mouthpiece controlled using a smartphone application (APP), denoted as the TP wireless application (TPWA). The mouthpiece was designed with a palate-shaped air balloon containing a tongue contact bump and a plastic bite positioning tube. Fatigue load testing was performed to evaluate mouthpiece durability by applying 700 displacement cycles (50 times a day for one week during training, with twice the safety factor) on the air balloon. The main component used in developing this instrument was a silicon pressure sensor equipped with wireless Bluetooth connection. Young (52 adults; mean age = 20.23 ± 2.17) and elderly (40 adults; mean age = 72.60 ± 7.03) individuals participated in the test with the new instrument, with the results compared to those of a commercial device. The TPWA mouthpiece fatigue test showed that mean response pressures were maintained at 12 kPa. No significant (p > 0.05) differences were found during testing repetitions 0-10 and 701-710. There were no significant differences in the maximum TP values presented between the test sequences using different instruments for young and elderly participants. The TPWA results showed that TP values gradually decreased with increasing age (40.77 kPa for young and 16.55 kPa for elderly participants). The maximum TP for males (43.51 kPa) was significantly larger than that for females (35.14 kPa) in the young group, but an opposite trend was seen in the elderly group (12.97 for males and 17.59 for females). Thus, this study developed a novel chair-side TP measurement instrument with Bluetooth wireless mobile application control. A durable positioning oral mouthpiece was approved for measuring pressure sufficiently, reliably, and precisely for TP screening.

18.
Biosensors (Basel) ; 12(1)2021 Dec 22.
Article in English | MEDLINE | ID: mdl-35049632

ABSTRACT

This study aims to develop a generalizable method for designing a patient-specific reconstructive scaffold implant for a large distal lateral femur defect using finite element (FE) analysis and topology optimization. A 3D solid-core implant for the distal femur defect was designed to withhold the femur load. Data from FE analysis of the solid implant were use for topology optimization to obtain a 'bone scaffold implant' with light-weight internal cavity and surface lattice features to allow for filling with bone material. The bone scaffold implant weighed 69.6% less than the original solid-core implant. The results of FE simulation show that the bone repaired with the bone scaffold implant had lower total displacement (12%), bone plate von Mises stress (34%), bone maximum first principal stress (33%), and bone maximum first principal strain (32%) than did bone repaired with bone cement. The trend in experimental strain with increasing load on the composite femur was greater with bone cement than with the bone scaffold implant. This study presents a generalizable method for designing a patient-specific reconstructive scaffold implant for the distal lateral femur defect that has sufficient strength and space for filling with allograft bone.


Subject(s)
Bone Cements , Femur , Biomechanical Phenomena , Femur/diagnostic imaging , Femur/surgery , Finite Element Analysis , Humans , Prostheses and Implants , Stress, Mechanical
19.
Diagnostics (Basel) ; 10(10)2020 Oct 19.
Article in English | MEDLINE | ID: mdl-33086684

ABSTRACT

This study developed a numerical simulation to understand bone mechanical behavior and micro-crack propagation around a fixation screw with severe mandibular defects. A mandible finite element (FE) model was constructed in a rabbit with a right unilateral body defect. The reconstruction implant was designed to be fixed using six screws distributed on the distal and mesial sides. The element death technique provided in FE analysis was combined with bone remodeling theory to simulate bone necrosis around the fixation screw in which the strain value reached the overload threshold. A total of 20 iterations were performed to observe the micro-crack propagation pattern for each screw according to the high strain locations occurring in each result from consecutive iterations. A parallel in vivo animal study was performed to validate the FE simulation by placing specific metal 3D printing reconstruction implants in rabbits to compare the differences in bone remodeling caused by radiation treatment after surgery. The results showed that strain values of the surrounding distal bone fixation screws were much larger than those at the mesial side. With the increase in the number of iteration analyses, the micro-crack prorogation trend for the distal fixation screws can be represented by the number and element death locations during the iteration analysis process. The corresponding micro-movement began to increase gradually and induced screw loosening after iteration calculation. The strained bone results showed that relatively high bone loss (damage) existed around the distal fixation screws under radiation treatment. This study concluded that the FE simulation developed in this study can provide a better predictive diagnosis method for understanding fixation screw loosening and advanced implant development before surgery.

20.
Clin Biomech (Bristol, Avon) ; 74: 124-130, 2020 04.
Article in English | MEDLINE | ID: mdl-32361012

ABSTRACT

BACKGROUND: This study evaluated the effect of two self-tapping implants on implant stability in immediate implantation. METHODS: Two types of self-tapping implants, straight flute (STF) and spiral flute (SPF) designs, were studied. Two synthetic bone blocks with varying densities (0.32 g/cm3 and 0.16 g/cm3) were chosen to simulate the bone quality of the anterior maxilla. Insertion torque values were measured by a torque testing machine during implant insertion. Four biomechanical tests were performed: resonance frequency analysis was conducted using the Osstell device, and the strengths of screw push-in, lateral bending, and pull-out were evaluated using an MTS machine. The strength for each design feature was obtained by averaging the results of 10 trials. In total, 40 specimens were tested for each bone density. Statistical difference was determined by one-way analysis of variance followed by Bonferroni post hoc multiple tests between groups. FINDINGS: The STF and SPF groups exhibited similar insertion torque values (p = 0.525 in low-density bone, and p = 0.99 in high-density bone). A significant difference (p < 0.001) was observed in the push-in test between the two groups when low-density bone was tested. The SPF group exhibited a significantly higher lateral bending force (p = 0.001) and a higher stiffness (p < 0.001) than the STF group in high-density bone. The SPF design attained higher (p < 0.001) ISQ numbers than the STF design, but all numbers were below 60. INTERPRETATION: Implant stability can be influenced by the apical fixture design of self-tapping implants in immediate implantation.


Subject(s)
Dental Implants , Mechanical Phenomena , Prosthesis Design , Biomechanical Phenomena , Bone Density , Humans , Surface Properties , Torque
SELECTION OF CITATIONS
SEARCH DETAIL
...