Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
ACS Sustain Chem Eng ; 12(20): 7924-7934, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38783844

ABSTRACT

Perfluorinated sulfonic acid ionomers are well known for their unique water uptake properties and chemical/mechanical stability. Understanding their performance-stability trade-offs is key to realizing membranes with optimal properties. Terahertz time-domain spectroscopy has been demonstrated to resolve water states inside industrially relevant membranes, producing qualitatively agreeable results to conventional gravimetric analysis and prior demonstrations. Using the proposed humidity-controlled terahertz time-domain spectroscopy, here we quantify this detailed water information inside commercially available Nafion membranes at various humidities for direct comparison against literature values from dynamic vapor sorption, differential scanning calorimetry, and Fourier transform infrared spectroscopy on selected samples. Using this technique therefore opens up opportunities for rapid future parameter space investigation for membrane optimization.

2.
Sci Rep ; 13(1): 10809, 2023 Jul 04.
Article in English | MEDLINE | ID: mdl-37402736

ABSTRACT

Fourier domain optical coherence tomography (FD-OCT) is a well-established imaging technique that provides high-resolution internal structure images of an object at a fast speed. Modern FD-OCT systems typically operate at speeds of 40,000-100,000 A-scans/s, but are priced at least tens of thousands of pounds. In this study, we demonstrate a line-field FD-OCT (LF-FD-OCT) system that achieves an OCT imaging speed of 100,000 A-scan/s at a hardware cost of thousands of pounds. We demonstrate the potential of LF-FD-OCT for biomedical and industrial imaging applications such as corneas, 3D printed electronics, and printed circuit boards.

3.
Plant Direct ; 6(7): e428, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35844779

ABSTRACT

Seed germination and uniform plant stand in the field are the most critical crop growth stages determining the final yield. Pea (Pisum sativum L.) seeds production is often hampered due to the seed dormancy caused by the hard seed coat. Such effect is mainly attributed to poor or uneven germination and unsynchronised seedling emergence. Understanding the time course of water intake and several critical germination indicators can reveal many features of seed germination such as rate and uniformity. This paper used optical coherence tomography (OCT), a noninvasive and cross-sectional imaging technique, to monitor the inner structural changes throughout the germination process. A sequence of cross-sectional OCT images of pea (P. sativum L.) seeds, together with additional microscopic optical images, was recorded continuously and in situ for over 40 h. OCT and microscopic images revealed the changes in the internal structure and the external shape of the pea seeds during germination, respectively. It was found that the cross-sectional OCT images helped to identify the critical indicators distinguishing the different phases of germination pea seeds. Therefore, the presented OCT approach offers a fast and nondestructive way to precisely measure the structural indicators in different germination phases.

4.
J Biomater Appl ; 36(5): 912-929, 2021 11.
Article in English | MEDLINE | ID: mdl-34139891

ABSTRACT

The eggshell membrane (ESM) is an abundant resource with innate complex structure and composition provided by nature. With at least 60 million tonnes of hen eggs produced globally per annum, utilisation of this waste resource is highly attractive in positively impacting sustainability worldwide. Given the morphology and mechanical properties of this membrane, it has great potential as a biomaterials for wound dressing. However, to date, no studies have demonstrated nor reported this application. As such, the objective of this investigation was to identify and optimise a reproducible extraction protocol of the ESM and to assess the physical, chemical, mechanical and biological properties of the substrate with a view to use as a wound dressing. ESM samples were isolated by either manual peeling (ESM-strip) or via extraction using acetic acid [ESM-A0.5] or ethylenediaminetetraacetic acid, EDTA [ESM-E0.9]. Energy dispersive X-ray spectroscopy (EDS) confirmed that there were no traces of calcium residues from the extraction process. Fourier transform infrared (FTIR) spectroscopy revealed that the extraction method (acetic acid and EDTA) did not alter the chemical structures of the ESM and also clarified the composition of the fibrous proteins of the ESM. Scanning electron microscopy (SEM) analyses revealed a three-layer composite structure of the ESM: an inner layer as continuous, dense and non-fibrous (limiting membrane), a middle layer with a network of fibres (inner shell membrane) and the outer layer (outer shell membrane) of larger fibres. Material properties including optical transparency, porosity, fluid absorption/uptake, thermal stability, mechanical profiling of the ESM samples were performed and demonstrated suitable profiles for translational applications. Biological in vitro studies using SV40 immortalised corneal epithelial cells (ihCEC) and corneal mesenchymal stromal cells (C-MSC) demonstrated excellent biocompatibility. Taken together, these results document the development of a novel sustainable biomaterial that may be used for ophthalmic wounds and/or other biomedical therapies.


Subject(s)
Biocompatible Materials/chemistry , Corneal Injuries/therapy , Egg Shell/chemistry , Wound Healing , Animals , Bandages , Biomimetics , Cell Culture Techniques , Chickens , Microscopy, Electron, Scanning , Spectroscopy, Fourier Transform Infrared , Tissue Engineering
5.
Glob Chall ; 5(2): 2000102, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33552556

ABSTRACT

Melanins are a class of biopolymers that are widespread in nature and have diverse origins, chemical compositions, and functions. Their chemical, electrical, optical, and paramagnetic properties offer opportunities for applications in materials science, particularly for medical and technical uses. This review focuses on the application of analytical techniques to study melanins in multidisciplinary contexts with a view to their use as sustainable resources for advanced biotechnological applications, and how these may facilitate the achievement of the United Nations Sustainable Development Goals.

6.
Anal Chem ; 93(4): 2449-2455, 2021 02 02.
Article in English | MEDLINE | ID: mdl-33401901

ABSTRACT

In the field of non-destructive testing, terahertz sensing has been used to analyze a wide range of materials where the most successful applications have involved materials that are semi-transparent to terahertz radiation. In this work, we demonstrate the sensitivity of terahertz time-domain spectroscopy to quantify water absorption in hygrothermally aged simple and commercial epoxy systems supported by conventional gravimetric analysis.

7.
Sensors (Basel) ; 20(5)2020 Mar 06.
Article in English | MEDLINE | ID: mdl-32155785

ABSTRACT

Terahertz pulsed imaging (TPI) was introduced approximately fifteen years ago and has attracted a lot of interest in the pharmaceutical industry as a fast, non-destructive modality for quantifying film coatings on pharmaceutical dosage forms. In this topical review, we look back at the use of TPI for analysing pharmaceutical film coatings, highlighting the main contributions made and outlining the key challenges ahead.


Subject(s)
Pharmaceutical Preparations/chemistry , Terahertz Imaging , Calibration , Dosage Forms , Refractometry
8.
Opt Express ; 27(10): 13951-13964, 2019 May 13.
Article in English | MEDLINE | ID: mdl-31163852

ABSTRACT

In the laundry industry, colorimetry is a common way to evaluate the stain removal efficiency of detergents and cleaning products. For ease of visualization, the soiling agent is treated with a dye before measurement. However, it effectively measures the dye removal rather than stain removal, and it cannot provide depth-resolved information of the sample. In this study, we show that full-field (FF) optical coherence tomography (OCT) technique is capable of measuring the cleaning effect on cotton fabric by imaging the sub-surface features of fabric samples. We used a broadband light-emitting diode (LED) source to power the FF-OCT system that achieves the resolution of 1 µm axially and 1.6 µm laterally. This allows the micron-sized cotton fibres/fibrils at different depth positions to be resolved. The clean, the soiled, and the washed samples can be differentiated from their cross-sectional images using OCT, where the cleaning effect can be correlated with the sub-surface fibre volume. The experimental results of the proposed method were found to be in good agreement with those of the standard colorimetry method. The proposed technique therefore offers an alternative way for measuring the stain removal from fabric substrate to assess the effectiveness of laundry detergent products.

9.
Sci Rep ; 7(1): 10625, 2017 09 06.
Article in English | MEDLINE | ID: mdl-28878213

ABSTRACT

We demonstrate how terahertz time-domain spectroscopy (THz-TDS) operating in reflection geometry can be used for quantitative conductivity mapping of large area chemical vapour deposited graphene films on sapphire, silicon dioxide/silicon and germanium. We validate the technique against measurements performed with previously established conventional transmission based THz-TDS and are able to resolve conductivity changes in response to induced back-gate voltages. Compared to the transmission geometry, measurement in reflection mode requires careful alignment and complex analysis, but circumvents the need of a terahertz transparent substrate, potentially enabling fast, contactless, in-line characterisation of graphene films on non-insulating substrates such as germanium.

10.
J Pharm Sci ; 106(10): 3171-3176, 2017 10.
Article in English | MEDLINE | ID: mdl-28624417

ABSTRACT

Optical coherence tomography (OCT) has recently been demonstrated to measure the film coating thickness of pharmaceutical tablets and pellets directly. The results enable the analysis of inter- and intra-tablet coating variability at an off-line and in-line setting. To date, only a few coating formulations have been tried and there is very little information on the applicability of OCT to other coatings. As it is well documented that optical methods including OCT are prone to scattering leading to limited penetration, some pharmaceutical coatings may not be measurable altogether. This study presents OCT measurements of 22 different common coatings for the assessment of OCT applicability.


Subject(s)
Pharmaceutical Preparations/chemistry , Tablets, Enteric-Coated/chemistry , Chemistry, Pharmaceutical/methods , Drug Compounding/methods , Drug Implants/chemistry , Excipients/chemistry , Surface Properties , Tomography, Optical Coherence/methods
11.
J Pharm Sci ; 106(4): 1075-1084, 2017 04.
Article in English | MEDLINE | ID: mdl-28017653

ABSTRACT

We present in-line coating thickness measurements acquired simultaneously using 2 independent sensing modalities: terahertz pulsed imaging (TPI) and optical coherence tomography (OCT). Both techniques are sufficiently fast to resolve the coating thickness of individual pharmaceutical tablets in situ during the film coating operation, and both techniques are direct structural imaging techniques that do not require multivariate calibration. The TPI sensor is suitable to measure coatings greater than 50 µm and can penetrate through thick coatings even in the presence of pigments over a wide range of excipients. Due to the long wavelength, terahertz radiation is not affected by scattering from dust within the coater. In contrast, OCT can resolve coating layers as thin as 20 µm and is capable of measuring the intratablet coating uniformity and the intertablet coating thickness distribution within the coating pan. However, the OCT technique is less robust when it comes to the compatibility with excipients, dust, and potentially the maximum coating thickness that can be resolved. Using a custom-built laboratory scale coating unit, the coating thickness measurements were acquired independently by the TPI and OCT sensors throughout a film coating operation. Results of the in-line TPI and OCT measurements were compared against one another and validated with off-line TPI and weight gain measurements. Compared with other process analytical technology sensors, such as near-infrared and Raman spectroscopy, the TPI and OCT sensors can resolve the intertablet thickness distribution based on sampling a significant fraction of the tablet populations in the process. By combining 2 complementary sensing modalities, it was possible to seamlessly monitor the coating process over the range of film thickness from 20 µm to greater than 250 µm.


Subject(s)
Chemistry, Pharmaceutical/methods , Tablets, Enteric-Coated/chemical synthesis , Terahertz Imaging/methods , Tomography, Optical Coherence/methods , Chemistry, Pharmaceutical/instrumentation , Tablets, Enteric-Coated/analysis , Terahertz Imaging/instrumentation , Tomography, Optical Coherence/instrumentation
12.
J Pharm Sci ; 106(2): 546-553, 2017 02.
Article in English | MEDLINE | ID: mdl-27810097

ABSTRACT

Spectral domain optical coherence tomography (SD-OCT) has recently attracted a lot of interest in the pharmaceutical industry as a fast and non-destructive modality for direct quantification of thin film coatings that cannot easily be resolved with other techniques. While previous studies with SD-OCT have estimated the intra-tablet coating uniformity, the estimates were based on limited number of B-scans. In order to obtain a more accurate estimate, a greater number of B-scans are required that can quickly lead to an overwhelming amount of data. To better manage the data so as to generate a more accurate representation of the intra-tablet coating uniformity without compromising on the achievable axial resolution and imaging depth, we comprehensively examine an algebraic reconstruction technique with OCT to significantly reduce the data required. Specifically, a set of coated pharmaceutical tablets with film coating thickness in the range of 60-100 µm is investigated. Results obtained from performing the reconstruction reveal that only 30% of the acquired data are actually required leading to a faster convergence time and a generally good agreement with benchmark data against the intra-tablet coating uniformity measured with terahertz pulsed imaging technology.


Subject(s)
Tablets, Enteric-Coated/chemistry , Tomography, Optical Coherence/methods , Drug Compounding , Equipment Design , Image Processing, Computer-Assisted , Terahertz Imaging , Tomography, Optical Coherence/instrumentation
14.
Obes Surg ; 26(4): 810-5, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26208411

ABSTRACT

OBJECTIVE: The objective of this study was to investigate the effects of adherence to postoperative recommended psychiatric follow-up on weight loss in morbid obesity patients with psychiatric disorders 1 year after gastric bypass. METHODS: Three hundred eighteen morbidly obese patients were retrospectively reviewed. They were divided into four groups according to preoperative psychiatric evaluations and adherence to psychiatric follow-up 1 year after their bypass surgery. The first group included patients who did not meet the referral criteria (NMRC). The second group consisted of patients who did not meet the psychiatric diagnostic criteria (NMDC). The third group was patients who met criteria for a psychiatric disorder and were nonadherent (NA) to psychiatric follow-up. The fourth group consisted of patients who met criteria for a psychiatric disorder and were adherent (A) to psychiatric follow-up. RESULTS: The A group exhibited higher % change in BMI than the NA and NMRC groups at 1 year after bypass surgery. Regression analyses to examine the effects of the grouping variable on % change in BMI were performed by controlling the effects of age, gender, educational level, and preoperative BMI. The regression coefficient for the grouping variable was 0.175 (p = .003) at the 6-month and 0.133 (p = .027) at the 1-year % change in BMI. CONCLUSION: Our preliminary data suggest that adherence to postoperative psychiatric follow-up is associated with greater postoperative weight loss. However, evidence from studies with a longer follow-up is required to justify this therapeutic approach.


Subject(s)
Gastric Bypass , Mental Disorders/therapy , Mental Health Services , Patient Compliance , Weight Loss , Adult , Body Mass Index , Female , Follow-Up Studies , Humans , Male , Obesity, Morbid/psychology , Obesity, Morbid/surgery , Postoperative Care , Retrospective Studies
15.
Curr Pharm Biotechnol ; 17(2): 200-7, 2015.
Article in English | MEDLINE | ID: mdl-26511980

ABSTRACT

Mammalian cells are involved in a range of biotechnological applications and more recently have been increasingly exploited in regenerative medicine. Critical to successful applications involving mammalian cells are their long-term storage and transport, for which cryopreservation in liquid nitrogen is the most frequently used strategy. However, cryopreservation suffers from high costs, difficulties in transport logistics and the use of undesirable additives (e.g. animal sera or DMSO). An alternative approach, proposed as low cost, low maintenance and process-compatible, is viable desiccation of mammalian cells. Several groups claim to have achieved this, but the extent of desiccation in the cell samples concerned is not always clear, in part because of difficulties in determining very low water content. Although several techniques exist that are frequently used to quantify the amount of water in samples (e.g. FTIR spectroscopy, thermogravimetric analysis (TGA), NMR spectroscopy), the complexity of sample preparation, as well as the costs and time constraints involved are disadvantageous. Here, we assess a novel, rapid and low cost technique, i.e. terahertz (THz) spectroscopy, for the quantification of water content within dehydrated mammalian cell samples.


Subject(s)
Water/chemistry , Water/metabolism , 3T3 Cells , Animals , Cell Proliferation , Cell Survival , Cryopreservation/methods , Feasibility Studies , Mice , Spectroscopy, Fourier Transform Infrared
16.
J Pharm Sci ; 104(10): 3377-85, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26284354

ABSTRACT

Spectral domain optical coherence tomography (OCT) has recently attracted a lot of interest in the pharmaceutical industry as a fast and non-destructive modality for quantification of thin film coatings that cannot easily be resolved with other techniques. Because of the relative infancy of this technique, much of the research to date has focused on developing the in-line measurement technique for assessing film coating thickness. To better assess OCT for pharmaceutical coating quantification, this paper evaluates tablets with a range of film coating thickness measured using OCT and terahertz pulsed imaging (TPI) in an off-line setting. In order to facilitate automated coating quantification for film coating thickness in the range of 30-200 µm, an algorithm that uses wavelet denoising and a tailored peak finding method is proposed to analyse each of the acquired A-scan. Results obtained from running the algorithm reveal an increasing disparity between the TPI and OCT measured intra-tablet variability when film coating thickness exceeds 100 µm. The finding further confirms that OCT is a suitable modality for characterising pharmaceutical dosage forms with thin film coatings, whereas TPI is well suited for thick coatings.


Subject(s)
Tablets, Enteric-Coated/chemistry , Algorithms , Chemistry, Pharmaceutical , Data Interpretation, Statistical , Drug Compounding , Reproducibility of Results , Surface Properties , Terahertz Imaging , Tomography, Optical Coherence , Uncertainty , Wavelet Analysis
17.
J Pharm Sci ; 104(8): 2513-22, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26037660

ABSTRACT

A novel in-line technique utilising pulsed terahertz radiation for direct measurement of the film coating thickness of individual tablets during the coating process was previously developed and demonstrated on a production-scale coater. Here, we use this technique to monitor the evolution of tablet film coating thickness and its inter-tablet variability during the coating process under a number of different process conditions that have been purposefully induced in the production-scale coating process. The changes that were introduced to the coating process include removing the baffles from the coater, adding uncoated tablets to the running process, halting the drum, blockage of spray guns and changes to the spray rate. The terahertz sensor was able to pick up the resulting changes in average coating thickness in the coating drum and we report the impact of these process changes on the resulting coating quality.


Subject(s)
Drug Compounding/methods , Tablets, Enteric-Coated/chemistry , Automation , Chemical Phenomena , Electrochemical Techniques , Image Processing, Computer-Assisted , Quality Control , Reproducibility of Results , Surface Properties
18.
J Med Syst ; 39(4): 210, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25712814

ABSTRACT

Breast cancer is one of the most common cause of cancer mortality. Early detection through mammography screening could significantly reduce mortality from breast cancer. However, most of screening methods may consume large amount of resources. We propose a computational model, which is solely based on personal health information, for breast cancer risk assessment. Our model can be served as a pre-screening program in the low-cost setting. In our study, the data set, consisting of 3976 records, is collected from Taipei City Hospital starting from 2008.1.1 to 2008.12.31. Based on the dataset, we first apply the sampling techniques and dimension reduction method to preprocess the testing data. Then, we construct various kinds of classifiers (including basic classifiers, ensemble methods, and cost-sensitive methods) to predict the risk. The cost-sensitive method with random forest classifier is able to achieve recall (or sensitivity) as 100 %. At the recall of 100 %, the precision (positive predictive value, PPV), and specificity of cost-sensitive method with random forest classifier was 2.9 % and 14.87 %, respectively. In our study, we build a breast cancer risk assessment model by using the data mining techniques. Our model has the potential to be served as an assisting tool in the breast cancer screening.


Subject(s)
Breast Neoplasms/epidemiology , Data Mining/methods , Support Vector Machine , Age Factors , Aged , Bayes Theorem , Body Weights and Measures , Breast Feeding , Contraceptives, Oral, Hormonal , Early Detection of Cancer , Estrogen Replacement Therapy , Female , Genetic Predisposition to Disease , Humans , Menstruation , Middle Aged , Predictive Value of Tests , Risk Assessment
19.
J Pharm Sci ; 104(5): 1658-67, 2015 May.
Article in English | MEDLINE | ID: mdl-25645509

ABSTRACT

Tablet dissolution is strongly affected by swelling and solvent penetration into its matrix. A terahertz-pulsed imaging (TPI) technique, in reflection mode, is introduced as a new tool to measure one-dimensional swelling and solvent ingress in flat-faced pharmaceutical compacts exposed to dissolution medium from one face of the tablet. The technique was demonstrated on three tableting excipients: hydroxypropylmethyl cellulose (HPMC), Eudragit RSPO, and lactose. Upon contact with water, HPMC initially shrinks to up to 13% of its original thickness before undergoing expansion. HPMC and lactose were shown to expand to up to 20% and 47% of their original size in 24 h and 13 min, respectively, whereas Eudragit does not undergo dimensional change. The TPI technique was used to measure the ingress of water into HPMC tablets over a period of 24 h and it was observed that water penetrates into the tablet by anomalous diffusion. X-ray microtomography was used to measure tablet porosity alongside helium pycnometry and was linked to the results obtained by TPI. Our results highlight a new application area of TPI in the pharmaceutical sciences that could be of interest in the development and quality testing of advanced drug delivery systems as well as immediate release formulations.


Subject(s)
Chemistry, Pharmaceutical/methods , Powders/chemistry , Terahertz Imaging/methods , Diffusion , Solubility , Tablets
20.
J Pharm Sci ; 104(10): 3377-3385, 2015 Oct.
Article in English | MEDLINE | ID: mdl-28739039

ABSTRACT

Spectral domain optical coherence tomography (OCT) has recently attracted a lot of interest in the pharmaceutical industry as a fast and non-destructive modality for quantification of thin film coatings that cannot easily be resolved with other techniques. Because of the relative infancy of this technique, much of the research to date has focused on developing the in-line measurement technique for assessing film coating thickness. To better assess OCT for pharmaceutical coating quantification, this paper evaluates tablets with a range of film coating thickness measured using OCT and terahertz pulsed imaging (TPI) in an off-line setting. In order to facilitate automated coating quantification for film coating thickness in the range of 30-200µm, an algorithm that uses wavelet denoising and a tailored peak finding method is proposed to analyse each of the acquired A-scan. Results obtained from running the algorithm reveal an increasing disparity between the TPI and OCT measured intra-tablet variability when film coating thickness exceeds 100µm. The finding further confirms that OCT is a suitable modality for characterising pharmaceutical dosage forms with thin film coatings, whereas TPI is well suited for thick coatings. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 104:3377-3385, 2015.

SELECTION OF CITATIONS
SEARCH DETAIL
...