Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Psychol Med ; : 1-9, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38825858

ABSTRACT

BACKGROUND: Persistent cognitive deficits and functional impairments are associated with bipolar disorder (BD), even during the euthymic phase. The dysfunction of default mode network (DMN) is critical for self-referential and emotional mental processes and is implicated in BD. The current study aims to explore the balance of excitatory and inhibitory neurotransmitters, i.e. glutamate and γ-aminobutyric acid (GABA), in hubs of the DMN during the euthymic patients with BD (euBD). METHOD: Thirty-four euBD and 55 healthy controls (HC) were recruited to the study. Using proton magnetic resonance spectroscopy (1H-MRS), glutamate (with PRESS sequence) and GABA levels (with MEGAPRESS sequence) were measured in the medial prefrontal cortex/anterior cingulate cortex (mPFC/ACC) and the posterior cingulate gyrus (PCC). Measured concentrations of excitatory glutamate/glutamine (Glx) and inhibitory GABA were used to calculate the excitatory/inhibitory (E/I) ratio. Executive and attentional functions were respectively assessed using the Wisconsin card-sorting test and continuous performance test. RESULTS: euBD performed worse on attentional function than controls (p = 0.001). Compared to controls, euBD had higher E/I ratios in the PCC (p = 0.023), mainly driven by a higher Glx level in the PCC of euBD (p = 0.002). Only in the BD group, a marginally significant negative association between the mPFC E/I ratio (Glx/GABA) and executive function was observed (p = 0.068). CONCLUSIONS: Disturbed E/I balance, particularly elevated Glx/GABA ratio in PCC is observed in euBD. The E/I balance in hubs of DMN may serve as potential biomarkers for euBD, which may also contribute to their poorer executive function.

2.
Se Pu ; 41(8): 683-689, 2023 Aug.
Article in Chinese | MEDLINE | ID: mdl-37534555

ABSTRACT

Dendrobium officinale (D. officinale) and Anoectochilus roxburghii (A. roxburghii) are precious raw materials for traditional Chinese medicine. The growing demand for D. officinale and A. roxburghii cannot be met by current production techniques. Hence, the widespread artificial cultivation of D. officinale and A. roxburghii using substantial amounts of plant growth regulators (PGRs) has emerged. The excessive use of PGRs not only affects the quality and efficacy of medicinal materials but also causes a series of safety issues. Therefore, expanding research on residual PGRs in valuable Chinese medicinal materials is important to avoid the health hazards caused by these substances. Unfortunately, the identification of PGRs is challenging because of their trace and complex matrices. High performance liquid chromatography (HPLC) has become one of the mainstream analytical methods for PGR determination. An important consideration in the application of this technique to the detection of trace acidic PGRs is how to improve its accuracy and sensitivity. Three-phase hollow fiber liquid phase microextraction (3P-HF-LPME) has the advantages of a high enrichment factor, complex sample purification ability, low reagent consumption, low cost, and easy integration with chromatographic systems. Thus, the 3P-HF-LPME method overcomes the many shortcomings of traditional sample pretreatment methods. In this study, a novel, simple, and effective analytical method based on 3P-HF-LPME combined with HPLC was developed to extract, purify, enrich, and detect three trace acidic PGRs (indole-3-acetic acid, naphthyl acetic acid and indolebutyric acid) in D. officinale and A. roxburghii. The chromatographic separation conditions and 3P-HF-LPME model parameters were systematically optimized for this purpose. First, the sample solution was prepared by ultrasonication and low-temperature standing, and then adjusted to pH 3.0 using dilute hydrochloric acid. The sample solution (10 mL) and NaCl (1.50 g) were stored in a 15 mL brown extraction bottle with a built-in magnetic stirrer. Next, 30 µL of NaOH solution (pH 11.0) as the inner phase solution was injected into the inner cavity of a hollow fiber tube, which was subsequently sealed at both ends. The hollow fiber tube was soaked in n-octanol for 5 min and dried naturally to remove excess extraction solvent from its surface. Finally, the fiber tube was placed in a brown extraction bottle and stirred using a thermostatic magnetic stirrer at 40 ℃ and 1600 r/min for 2 h. After extraction, the three target analytes were separated on a Welch Ultimate XB-C18 column (250 mm×4.6 mm, 5 µm) under isocratic elution conditions using acetic acid aqueous solution and methanol (45∶55, v/v) as the eluent. The results indicated that the three PGRs showed good linearity in the range of 0.5-100.0 µg/L (coefficients of determination (r2)=0.9999), with limits of detection (LODs) of 0.02-0.15 µg/L. The method recoveries were 88.5-102.2%, with relative standard deviations (RSDs) of less than 3.7% (n=3). The extraction efficiencies and enrichment factors of the three PGRs in 15 batches of fresh D. officinale and A. roxburghii products were found to be 42.0%-86.8% and 140-289. Full-scan mass spectrometry was used to further identify positive samples to avoid false-positive results and enhance the reliability of the experimental method. In summary, the proposed method is sensitive, accurate, reliable, environment friendly, and capable of high enrichment. It could be used to determine the residues of three acidic PGRs in D. officinale and A. roxburghii. Moreover, it can provide technical support for the residue detection of PGRs in other Chinese medicinal materials.


Subject(s)
Dendrobium , Liquid Phase Microextraction , Plant Growth Regulators/analysis , Chromatography, High Pressure Liquid , Liquid Phase Microextraction/methods , Reproducibility of Results
3.
IEEE Trans Biomed Circuits Syst ; 9(1): 105-12, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24956395

ABSTRACT

An airflow sensing chip, which integrates MEMS sensors with their CMOS signal processing circuits into a single chip, is proposed for respiration detection. Three micro-cantilever-based airflow sensors were designed and fabricated using a 0.35 µm CMOS/MEMS 2P4M mixed-signal polycide process. Two main differences were present among these three designs: they were either metal-covered or metal-free structures, and had either bridge-type or fixed-type reference resistors. The performances of these sensors were measured and compared, including temperature sensitivity and airflow sensitivity. Based on the measured results, the metal-free structure with fixed-type reference resistors is recommended for use, because it has the highest airflow sensitivity and also can effectively reduce the output voltage drift caused by temperature change.


Subject(s)
Monitoring, Ambulatory/instrumentation , Equipment Design , Humans , Micro-Electrical-Mechanical Systems , Respiration , Signal-To-Noise Ratio , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...