Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 121
Filter
1.
J Drugs Dermatol ; 23(4): 216-226, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38564399

ABSTRACT

BACKGROUND: Multiple treatment options exist for the management of moderate-to-severe acne. However, the comparative effectiveness (efficacy/safety) of moderate-to-severe acne treatments has not been systematically examined. METHODS: A systematic literature review (SLR) was conducted to identify randomized controlled trials of ≥4 weeks of treatment (topical, oral, physical, or combinations) for moderate-to-severe facial acne in patients aged ≥9 years. Efficacy outcomes included: percentage of patients achieving ≥2-grade reduction from baseline and “clear” or “almost clear” for global severity score (treatment success); absolute change in inflammatory (ILs reduction); and noninflammatory lesion counts (NILs reduction). A random-effects network meta-analysis (NMA) was conducted for the efficacy outcomes. Treatments were ranked with posterior rank plots and surface under cumulative ranking values.  Results: Eighty-five studies were included in the SLR/NMA. Topical triple-agent fixed-dose combination (FDC) gel (clindamycin phosphate 1.2%/adapalene 0.15%/benzoyl peroxide 3.1%) and combinations of double-agent fixed-dose topical treatments with oral antibiotics (TOA3) consistently ranked in the top 3 treatments. Topical triple-agent FDC gel was numerically superior to TOA3 for treatment success (log-odds ratios: 1.84 [95% credible interval (CrI) 1.36 to 2.29]) and 1.69 (95% CrI: 1.01 to 2.32) vs placebo/vehicle). TOA3 was numerically superior to topical triple-agent FDC gel for reduction of ILs (mean difference: -8.21 [-10.33 to -6.13]) and -10.40 [-13.44 to -7.14] vs placebo/vehicle) and NILs (mean difference: -13.41 [-16.69 to -10.32] and -17.74 [-22.56 to -12.85] vs placebo/vehicle). CONCLUSIONS: Based on this SLR/NMA, topical triple-agent FDC gel was the most efficacious and safe treatment for moderate-to-severe acne. J Drugs Dermatol. 2024;23(4):     doi:10.36849/JDD.8148.


Subject(s)
Acne Vulgaris , Adapalene, Benzoyl Peroxide Drug Combination , Dermatologic Agents , Humans , Benzoyl Peroxide , Acne Vulgaris/diagnosis , Acne Vulgaris/drug therapy , Acne Vulgaris/chemically induced , Network Meta-Analysis , Drug Combinations , Treatment Outcome , Gels/therapeutic use
2.
JAMA Netw Open ; 7(3): e243994, 2024 Mar 04.
Article in English | MEDLINE | ID: mdl-38546650

ABSTRACT

This secondary analysis of a randomized clinical trial investigates the effect of spironolactone and cyproterone acetate hormone therapy on the QT interval corrected for heart rate among transgender women and nonbinary or transfeminine individuals.


Subject(s)
Electrocardiography , Hormones , Humans
3.
J Dermatolog Treat ; 34(1): 2245081, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37577786

ABSTRACT

OBJECTIVE: Fixed-combination halobetasol propionate (0.01%) and tazarotene (0.045%) lotion (HP/TAZ) is approved for the treatment of plaque psoriasis in adults, with a demonstrated efficacy and safety profile in phase 3 trials. This study examined the effect of HP/TAZ on the reduction of tumor necrosis factor alpha (TNF-α) and interleukin 17 A (IL-17A) and its correlation to psoriasis improvement. MATERIALS AND METHODS: Ten adults with mild-to-moderate plaque psoriasis and 2 symmetrical plaques self-applied HP/TAZ (treated plaque) or vehicle lotion (untreated plaque) for 12 weeks. At baseline and each study visit (weeks 2, 4, 8, and 12), Investigator's Global Assessment (IGA) score and erythema, scaling, and induration were assessed. Additionally, D-squame tape strips were utilized to quantify TNF-α and IL-17A in target lesions by enzyme-linked immunosorbent assay. RESULTS: Significant improvements in mean IGA score in HP/TAZ-treated compared with untreated plaques were evident at week 2 and maintained through week 12 (p < 0.003). HP/TAZ significantly reduced TNF-α levels at weeks 4 through 12 (p < 0.03) and IL-17A levels at weeks 2 through 8 (p < 0.05) in treated compared with untreated plaques. CONCLUSIONS: HP/TAZ was highly effective in treating psoriasis plaques and, although HP/TAZ is not a biologic, effectively reduced cytokine-associated inflammatory markers that drive psoriatic disease.


Subject(s)
Dermatologic Agents , Psoriasis , Adult , Humans , Tumor Necrosis Factor-alpha , Interleukin-17 , Drug Combinations , Treatment Outcome , Dermatologic Agents/therapeutic use , Severity of Illness Index , Skin Cream/therapeutic use , Clobetasol/therapeutic use , Psoriasis/drug therapy , Emollients , Emulsions , Immunoglobulin A , Double-Blind Method
4.
Kardiologiia ; 63(1): 54-59, 2023 Jan 31.
Article in English | MEDLINE | ID: mdl-36749202

ABSTRACT

Aim    The primary aim was to ascertain long-term rates of atrial fibrillation (AF) recurrence in this all-comer patient population undergoing elective electrical cardioversion (DCR). Secondary aims included procedural DCR success, clinical predictors of long-term maintenance of sinus rhythm (SR) and AF related hospitalizations.Material and Methods    A retrospective cohort study was conducted. Consecutive patients (n=316) undergoing elective DCR were included.Results    Successful immediate reversion to SR was attained in 266 (84 %) of patients. 224 (84 %) patients were followed up for a median period of 3.5 years (IQR 2.7-4.3). Most patients (150 [67 %]) had recurrence of AF / flutter at a median time of 240 days. Clinical predictors of AF recurrence included a history of AF (HR 0.63, p=0.038) and a dilated left atrium (HR 4.13, p=0.048). Maintenance of SR was associated with fewer unplanned hospitalizations for AF (HR 3.25, p<0.01).Conclusion    There was high procedural success post DCR. However, long-term rates of AF recurrence were high, and AF recurrences were associated with increased hospitalizations. These findings underscore the importance of clinical vigilance and multi-modal management as part of a comprehensive and effective rhythm control strategy.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Humans , Electric Countershock/methods , Retrospective Studies , Heart Atria , Recurrence , Treatment Outcome
6.
Psychol Med ; 53(11): 4952-4961, 2023 08.
Article in English | MEDLINE | ID: mdl-35775366

ABSTRACT

BACKGROUND: Posttraumatic stress symptoms (PTSS) are common following traumatic stress exposure (TSE). Identification of individuals with PTSS risk in the early aftermath of TSE is important to enable targeted administration of preventive interventions. In this study, we used baseline survey data from two prospective cohort studies to identify the most influential predictors of substantial PTSS. METHODS: Self-identifying black and white American women and men (n = 1546) presenting to one of 16 emergency departments (EDs) within 24 h of motor vehicle collision (MVC) TSE were enrolled. Individuals with substantial PTSS (⩾33, Impact of Events Scale - Revised) 6 months after MVC were identified via follow-up questionnaire. Sociodemographic, pain, general health, event, and psychological/cognitive characteristics were collected in the ED and used in prediction modeling. Ensemble learning methods and Monte Carlo cross-validation were used for feature selection and to determine prediction accuracy. External validation was performed on a hold-out sample (30% of total sample). RESULTS: Twenty-five percent (n = 394) of individuals reported PTSS 6 months following MVC. Regularized linear regression was the top performing learning method. The top 30 factors together showed good reliability in predicting PTSS in the external sample (Area under the curve = 0.79 ± 0.002). Top predictors included acute pain severity, recovery expectations, socioeconomic status, self-reported race, and psychological symptoms. CONCLUSIONS: These analyses add to a growing literature indicating that influential predictors of PTSS can be identified and risk for future PTSS estimated from characteristics easily available/assessable at the time of ED presentation following TSE.


Subject(s)
Stress Disorders, Post-Traumatic , Male , Humans , Female , Stress Disorders, Post-Traumatic/diagnosis , Stress Disorders, Post-Traumatic/epidemiology , Stress Disorders, Post-Traumatic/etiology , Prospective Studies , Reproducibility of Results , Risk Factors , Pain
7.
Cerebrovasc Dis ; 52(2): 166-170, 2023.
Article in English | MEDLINE | ID: mdl-36088906

ABSTRACT

BACKGROUND AND PURPOSE: Research into the temporal relationship between atrial tachyarrhythmias (atrial tachycardia [AT] and atrial fibrillation [AF]) and stroke has produced conflicting findings. Systematic categorization of stroke subtypes may help clarify the discussion. OBJECTIVES: The objective of the study was to examine the presence and timing of AT/AF in relation to ischemic stroke subtypes, categorized as either cardioembolic (CE) or non-CE. METHODS: Consecutive patients presenting to the Austin Hospital with acute stroke from 2012 to 2019 and a cardiac implantable electronic device (CIED) were identified. Using a case-control design, the temporal proximity of AT/AF episodes in the 90 days prior to stroke was compared in the CE and non-CE stroke groups. RESULTS: 5,591 patients presented to the Austin Hospital with acute stroke from 2012 to 2019, of whom 31 patients with an ischemic stroke and a CIED with ≥90 days of monitoring were identified. Twelve strokes were adjudicated as CE and 19 as non-CE by a stroke neurologist. Six of the 12 CE stroke patients (50%) experienced AT/AF within 30 days preceding their stroke, while none of the 19 non-CE stroke patients recorded any AT/AF in the same period (p = 0.001). Four CE stroke patients (33%) had no AT/AF preceding their strokes at any time. The odds ratio for CE stroke was highest (39; 95% confidence interval [CI]: 1.92-791.5) when AT/AF occurred in the 30 days prior, declining to 20.65 (95% CI: 1.00-427.66) and 6.07 (95% CI: 0.94-39.04) in the subsequent 31-60- and 61-90-day windows, respectively. CONCLUSIONS: CE strokes were associated with a significantly higher proportion of preceding AT/AF compared with non-CE strokes. These findings support a potential temporal relationship between AT/AF and CE stroke and demonstrate that stroke subtyping can better characterize the relationship between AF and ischemic stroke. However, this study's findings are limited by its sample size and small number of informative cases.


Subject(s)
Atrial Fibrillation , Embolic Stroke , Stroke , Humans , Risk Factors , Stroke/complications , Tachycardia/complications
8.
Intern Med ; 61(7): 969-977, 2022.
Article in English | MEDLINE | ID: mdl-35370254

ABSTRACT

Objective For risk stratification of sudden cardiac death in patients with structural heart disease, more precise predictors in addition to left ventricular ejection fraction (LVEF) are clinically needed. The present study assessed the utility of galectin-3 as an independent indicator for the prognosis of heart failure patients with implantable cardioverter-defibrillators (ICD). Methods The study population consisted of 91 consecutive patients who underwent a routine ICD checkup in our ICD outpatient clinic. Circulating galectin-3 was assessed using a commercially available enzyme-linked immunosorbent assay kit. The enrolled patients were prospectively followed. The primary endpoint was defined as the occurrence of appropriate ICD therapy (AIT), and the secondary endpoint was defined as the occurrence of unplanned overnight hospitalization due to decompensated heart failure (dHF). Results During a mean follow-up of 472±107 days, AIT occurred in 18 patients (20%). Unplanned hospitalizations due to dHF were noted in 12 patients (13%). A receiver-operative characteristics analysis demonstrated a sensitivity of 83% and specificity of 68% for AIT occurrences with a galectin-3 cut-off value of 13.1 ng/mL (area under the curve =0.82). A Kaplan-Meier analysis demonstrated that patients with galectin-3 >13.1 ng/mL had significantly higher incidences of AIT as compared to those with lower galectin-3 (log-rank, p<0.001). This significance was also observed in both subgroup analyses with ischemic and non-ischemic etiology. Cox regression demonstrated that higher galectin-3 was an independent predictor of AIT and dHF, even after adjusting for previous arrhythmic events. Conclusion The circulating galectin-3 level can be used as a clinical indicator of subsequent occurrence of ventricular arrhythmic events and decompensated heart failure, regardless of a history of ventricular arrhythmias.


Subject(s)
Defibrillators, Implantable , Heart Failure , Arrhythmias, Cardiac/etiology , Defibrillators, Implantable/adverse effects , Galectin 3 , Heart Failure/complications , Heart Failure/therapy , Hospitalization , Humans , Stroke Volume , Ventricular Function, Left
9.
Int J Cardiol Heart Vasc ; 35: 100828, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34235244

ABSTRACT

BACKGROUND: There is uncertainty regarding whether outcomes after Cardiac Implantable Electronic Devices (CIED) differ between women and men. There are no prospectively collected data regarding Australian CIED outcomes. This study aimed to determine whether the characteristics and outcomes of Australian patients undergoing CIED implantation differ by sex. METHODS: We prospectively followed 5,360 patients undergoing CIED implantation between 2015 and 2019 in a large multi-centre Australian registry. Patient characteristics, procedural data, medications and clinical outcomes to 1 year were analysed. RESULTS: The mean age was 76.2 + 11.2 years, and 2022 (37.7%) were female. Women were older than men at device implantation (77.0 ±â€¯11.6 years vs. 75.5 ±â€¯10.9 years, p < 0.001). Most implants were de novo (79.7%). Pacing was more commonly for sick sinus syndrome in women than men (54.4% vs. 47.2%, p < 0.001) and less often for A-V block (28.3% vs. 35.1%, p < 0.001). Adverse events at 30 days were low compared to international cohorts, for mortality (0.06%) and major complications (0.6%). There were no significant sex differences (women vs. men) for death (HR 1.33, 95% CI 0.58-3.13, p = 0.49) or major complications (HR 1.41, 95% 95% CI 0.65-3.03, p = 0.39). At 1-year, there was no difference in major complications or risk-adjusted all-cause mortality (HR 1.05, 95% CI 0.70-1.29, p = 0.77) between women and men. CONCLUSIONS: Clinical practice and 30-day outcomes after CIED implantation in Australia are consistent with international reports. There were no differences in procedural complication rates or clinical outcomes at 1-year between women and men, regardless of age or CIED system implanted.

10.
Pacing Clin Electrophysiol ; 44(9): 1504-1515, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34289168

ABSTRACT

PURPOSE: Recently, a novel cardiac imaging system based on a wide-band dielectric technology (KODEX-EPD) was introduced to guide catheter ablation. The aim of the study was to evaluate this 3D wide-band dielectric imaging system (WDIS) during cryoballoon (CB)-based atrial fibrillation (AF) ablation focusing on accuracy of pulmonary vein (PV)-anatomy. METHODS: In consecutive patients with symptomatic AF, CB-based ablation was performed in conjunction with the 3D WDIS. Selective PV-angiographies were performed, and 3D anatomy of the left atrium (LA) and PVs using the 3D WDIS was created. The ostial diameters of the ipsilateral right-sided and left-sided PVs and ostial diameters of the right-/left-sided upper/lower PVs demonstrated by selective angiographies were analyzed and compared to 3D WDIS-based PV visualization. RESULTS: In 65 patients (42/65 (65%) male, age 65 ± 9 years, 29/65 (45%) paroxysmal AF) a total of 260 PVs were identified. Median ostial PV-diameters for the ipsilateral left- and right-sided PVs were 38 [34; 43] and 37 [34; 40.3] mm when assessed fluoroscopically and 40 [35.7; 43] and 39 [35.0; 43] mm as demonstrated by 3D WDIS. There was no statistically significant difference between both methods regarding PV-diameter measurements. KODEX-EPD overestimated fluoroscopy measurements by 1.08 mm (95% limits of agreement of -1.93 mm and 4.1 mm). CONCLUSION: The novel wide-band dielectric 3D-imaging system is feasible to create high-resolution images of cardiac structures during CB ablation procedures and accurately visualizes PV-anatomy.


Subject(s)
Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/methods , Cryosurgery/methods , Imaging, Three-Dimensional/methods , Aged , Angiography , Female , Fluoroscopy , Humans , Male , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery
11.
J Dermatolog Treat ; 32(4): 391-398, 2021 Jun.
Article in English | MEDLINE | ID: mdl-31522563

ABSTRACT

BACKGROUND: Successful clinical data on halobetasol propionate 0.01%/tazarotene 0.045% (HP/TAZ) lotion in moderate-to-severe plaque psoriasis are published. This article charts its formulation development. METHODS: Dermal deposition, clinical efficacy, and synergistic effect of HP and TAZ delivered by polymeric emulsion technology was compared to HP 0.05% cream (Ultravate) and TAZ 0.1% cream (Tazorac); skin hydration and barrier maintenance with vehicle lotion through Trans Epidermal Water Loss (TEWL) and corneometry using human cadaver tissue; and steroid potency by vasoconstrictor assay (VCA) in healthy volunteers. Safety and tolerability evaluated in clinical studies and patient preference questionnaire. RESULTS: HP/TAZ lotion, using polymeric emulsion technology demonstrated better active ingredient delivery than HP 0.05% or TAZ 0.1% creams; supported by synergistic clinical data, with high HP potency outcome. Efficacy was rapid and sustained posttreatment. Layering TAZ 0.1% cream onto HP 0.05% cream had a negative effect on receptor phase levels. HP/TAZ lotion provided rapid and sustained increases in skin moisturization and gradually decreases in TEWL. Most subjects responded favorably to questions on the physical attributes of the vehicle lotion. CONCLUSIONS: Fixed combination HP 0.01%/TAZ 0.045% lotion formulation utilizing innovative polymeric emulsion technology and optimal selection of solvents/emollients/humectants, has recently been developed. Features inherent in technology translate into rapid, sustained efficacy, low irritation, and good patient acceptance.


Subject(s)
Clobetasol/analogs & derivatives , Nicotinic Acids/administration & dosage , Psoriasis/drug therapy , Clobetasol/administration & dosage , Dermatologic Agents/therapeutic use , Drug Combinations , Emulsions , Humans , Severity of Illness Index , Treatment Outcome
12.
J Interv Card Electrophysiol ; 61(3): 453-460, 2021 Sep.
Article in English | MEDLINE | ID: mdl-32740689

ABSTRACT

PURPOSE: Multipoint pacing (MPP) improves left ventricular (LV) electrical synchrony in cardiac resynchronization therapy (CRT). SyncAV automatically adjusts atrioventricular delay (AVD) according to intrinsic AV intervals and may further improve synchrony. Their combination has not been assessed. The objective was to evaluate the improvement in electrical synchrony achieved by SyncAV combined with MPP in an international, multicenter study. METHODS: Patients with LBBB undergoing CRT implant with a quadripolar lead (Abbott Quartet™) were prospectively enrolled. QRS duration (QRSd) was measured by blinded observers from 12-lead ECG during: intrinsic conduction, BiV pacing (conventional biventricular pacing, nominal static AVD), MPP (2 LV cathodes maximally spaced, nominal static AVD), BiV + SyncAV, and MPP + SyncAV. All SyncAV offsets were individualized for each patient to yield the narrowest QRSd during BiV pacing. QRSd changes were compared by ANOVA and post hoc Tukey-Kramer tests. RESULTS: One hundred and three patients were enrolled (65.7 ± 12.1 years, 67% male, 37% ischemic, EF 26.4 ± 6.5%, PR 190.3 ± 39.1 ms). Relative to intrinsic conduction (QRSd of 165 ± 16 ms), BiV reduced QRSd by 11.9% to 145 ± 18 ms (P < 0.001 vs intrinsic), and MPP reduced QRSd by 13.3% to 142 ± 19 ms (P < 0.001 vs intrinsic). However, enabling SyncAV with a patient-optimized offset nearly doubled this QRSd reduction. BiV + SyncAV reduced QRSd by 22.0% to 128 ± 13 ms (P < 0.001 vs BiV), while MPP + SyncAV reduced QRSd further by 25.6% to 122 ± 14 ms (P < 0.05 vs BiV + SyncAV). CONCLUSION: SyncAV can significantly improve acute electrical synchrony beyond conventional CRT, with further improvement achieved by superimposing MPP.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Cardiac Resynchronization Therapy Devices , Electrocardiography , Female , Heart Failure/diagnostic imaging , Heart Failure/therapy , Heart Ventricles , Humans , Male , Treatment Outcome
14.
JACC Clin Electrophysiol ; 6(12): 1525-1536, 2020 11.
Article in English | MEDLINE | ID: mdl-33213813

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate the safety and performance of an extravascular (EV) implantable cardioverter-defibrillator (ICD). BACKGROUND: Limitations of existing transvenous and subcutaneous ICD systems include lead reliability and morbidity issues associated with ICD lead implantation in the vasculature or lack of pacing therapies (e.g., antitachycardia pacing) in subcutaneous systems. The EV defibrillator uses a novel substernal lead placement to address these limitations. METHODS: This was a prospective, nonrandomized, chronic pilot study conducted at 4 centers in Australia and New Zealand. Participants were 21 patients referred for ICD implantation. Patients received EV ICD systems. Data collection included major systemic and procedural adverse events, defibrillation testing at implantation, and sensing and pacing thresholds. RESULTS: Among 20 patients who underwent successful implantation, the median defibrillation threshold was 15 J, and 90% passed defibrillation testing with a ≥10-J safety margin. Mean R-wave amplitude was 3.4 ± 2.0 mV, mean ventricular fibrillation amplitude was 2.8 ± 1.7 mV, and pacing was successful in 95% at ≤10 V. There were no intraprocedural complications. Two patients have undergone elective chronic system removal since hospital discharge. In the 15 patients presently implanted, the systems are stable in long-term follow-up. CONCLUSIONS: This first-in-human evaluation of an EV ICD demonstrated the feasibility of substernal lead placement, defibrillation, and pacing with a chronically implanted system. There were no acute major complications, and pacing, defibrillation, and sensing performance at implantation were successful in most patients. (Extravascular ICD Pilot Study [EV ICD]; NCT03608670).


Subject(s)
Defibrillators, Implantable , Defibrillators, Implantable/adverse effects , Humans , Pilot Projects , Prospective Studies , Reproducibility of Results , Ventricular Fibrillation/therapy
16.
Europace ; 22(8): 1240-1251, 2020 08 01.
Article in English | MEDLINE | ID: mdl-32500141

ABSTRACT

AIMS: The aim of this study was to analyse tamponades following electrophysiological procedures regarding frequency and mortality in a high-volume centre and to identify independent predictors for severe tamponades. METHODS AND RESULTS: We performed a retrospective study on 34 982 consecutive patients undergoing diagnostic electrophysiological studies or catheter ablation of cardiac arrhythmias. The combined endpoint was defined as severe tamponade. Criteria for severe tamponade included surgical repair, repeat pericardiocentesis, cardiopulmonary resuscitation, intrahospital death or death during follow-up, and thrombo-embolic events or complications due to therapeutic management. Multivariate analysis was performed to identify independent predictors for severe tamponade. A total of 226 tamponades were identified. Overall frequency of tamponades was 0.6%. Procedures requiring epicardial approach had the highest rate of tamponades (9.4%). Twenty-nine patients with tamponade underwent surgery (12.8% of all tamponades and 21.4% of tamponades during epicardial procedures). Overall tamponade-related mortality was 0.03% (9 deaths). Fifty-six patients (24.8%) experienced severe tamponade. Independent risk factors for severe tamponades were endocardial ablation of ventricular tachycardia, epicardial approach, balloon device ablation, high aspiration volume during pericardiocentesis and structural heart disease. CONCLUSION: The frequency of tamponades is strongly dependent on the type of procedure performed. Overall tamponade-related mortality was low but significantly higher in patients undergoing epicardial procedures. Surgical backup should be considered for patients undergoing complex ventricular tachycardia ablation and left atrial ablation procedures.


Subject(s)
Cardiac Tamponade , Catheter Ablation , Cardiac Electrophysiology , Cardiac Tamponade/diagnosis , Cardiac Tamponade/surgery , Catheter Ablation/adverse effects , Humans , Pericardiocentesis/adverse effects , Retrospective Studies , Treatment Outcome
17.
J Drugs Dermatol ; 19(5): 504-514, 2020 May 01.
Article in English | MEDLINE | ID: mdl-32484629

ABSTRACT

BACKGROUND: Previous results from two phase 3 studies demonstrated efficacy and safety of fixed combination halobetasol propionate 0.01%/tazarotene 0.045% (HP/TAZ) lotion in participants with moderate-to-severe plaque psoriasis. This post hoc analysis evaluated sex-specific efficacy and safety of HP/TAZ lotion. METHODS: In two randomized, double-blind, phase 3 studies, participants were randomized (2:1) to receive HP/TAZ or vehicle lotion once daily for 8 weeks. Male and female participants were evaluated separately in this pooled analysis. Efficacy assessments included treatment success (at least 2­grade improvement in Investigator's Global Assessment [IGA] score and score of clear/almost clear), impact on individual signs of psoriasis, and affected Body Surface Area (BSA). RESULTS: The analysis included 272 males (HP/TAZ, n=175; vehicle, n=97) and 146 females (HP/TAZ, n=101; vehicle, n=45). Significantly more participants achieved overall treatment success at week 8 with HP/TAZ versus vehicle in both male (38.4% vs 9.8%) and female (44.5% vs 9.9%) subgroups (P<0.001, both). Erythema, plaque elevation, and scaling were also reduced by week 8 in both males and females, with significantly more HP/TAZ-treated participants achieving at least 2­grade improvement in each sign of psoriasis than vehicle-treated participants (P<0.001 each, both groups). Mean reductions in affected BSA were significantly greater with HP/TAZ versus vehicle lotion in both males and females (P≤0.001, both). The most frequent treatment-related adverse events were contact dermatitis, pruritis, and application site pain (each 4.0%) in females and contact dermatitis (7.6%) in males. CONCLUSION: HP/TAZ lotion was highly effective and safe in both males and females with moderate-to-severe psoriasis over 8 weeks of once-daily use. J Drugs Dermatol. 2020;19(5): doi:10.36849/JDD.2020.5021.


Subject(s)
Clobetasol/analogs & derivatives , Nicotinic Acids/administration & dosage , Psoriasis/drug therapy , Skin Cream/administration & dosage , Adult , Aged , Clobetasol/administration & dosage , Clobetasol/adverse effects , Dermatitis, Contact/epidemiology , Dermatitis, Contact/etiology , Double-Blind Method , Drug Combinations , Female , Humans , Male , Middle Aged , Nicotinic Acids/adverse effects , Pain/epidemiology , Pain/etiology , Pruritus/epidemiology , Pruritus/etiology , Psoriasis/diagnosis , Severity of Illness Index , Sex Factors , Skin Cream/adverse effects , Treatment Outcome
18.
Sci Rep ; 10(1): 8445, 2020 05 21.
Article in English | MEDLINE | ID: mdl-32439873

ABSTRACT

Artificial intelligence (AI) is developing rapidly in the medical technology field, particularly in image analysis. ECG-diagnosis is an image analysis in the sense that cardiologists assess the waveforms presented in a 2-dimensional image. We hypothesized that an AI using a convolutional neural network (CNN) may also recognize ECG images and patterns accurately. We used the PTB ECG database consisting of 289 ECGs including 148 myocardial infarction (MI) cases to develop a CNN to recognize MI in ECG. Our CNN model, equipped with 6-layer architecture, was trained with training-set ECGs. After that, our CNN and 10 physicians are tested with test-set ECGs and compared their MI recognition capability in metrics F1 (harmonic mean of precision and recall) and accuracy. The F1 and accuracy by our CNN were significantly higher (83 ± 4%, 81 ± 4%) as compared to physicians (70 ± 7%, 67 ± 7%, P < 0.0001, respectively). Furthermore, elimination of Goldberger-leads or ECG image compression up to quarter resolution did not significantly decrease the recognition capability. Deep learning with a simple CNN for image analysis may achieve a comparable capability to physicians in recognizing MI on ECG. Further investigation is warranted for the use of AI in ECG image assessment.


Subject(s)
Algorithms , Artificial Intelligence , Databases, Factual , Deep Learning , Electrocardiography/methods , Myocardial Infarction/diagnosis , Neural Networks, Computer , Humans , Myocardial Infarction/diagnostic imaging
19.
Expert Rev Med Devices ; 17(6): 555-563, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32401089

ABSTRACT

INTRODUCTION: Catheter ablation (CA) for atrial fibrillation (AF) is an effective treatment option with encouraging clinical outcome data. Further improvement of catheter technologies is desirable, in particular for patients with persistent and long-standing persistent AF. The aim of this review is to provide an overview of novel ablation tools in AF-ablation. AREAS COVERED: The most widely used ablation tool still is the single-tip catheter for radiofrequency (RF) ablation. Contact-force (CF) catheters and the introduction of individualized ablation protocols may overcome limitations of single-tip RF-based ablation. Furthermore, balloon-based pulmonary vein isolation (PVI) - first and foremost the cryoballoon (CB) - based ablation - moved into the foreground especially for the treatment of paroxysmal AF, because of its ease of use and proven safety. Upcoming RF balloon technologies are also promising. Moreover, new mapping and imaging technologies might help to identify non-PV-triggers in patients with arrhythmia recurrence and may have the potential to enable real-time therapy assessment. EXPERT OPINION: New ablation tools such as CF-sensing catheters or novel balloon-devices could help to overcome the major limitation of PV-reconnection and lead to improved outcomes. Moreover, novel mapping tools to identify extra-PV-triggers may improve ablation success in patients with persistent and long-standing persistent AF.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Inventions , Catheter Ablation/adverse effects , Electrodes , Humans , Imaging, Three-Dimensional , Pulmonary Veins/surgery
20.
J Electrocardiol ; 60: 118-125, 2020.
Article in English | MEDLINE | ID: mdl-32361086

ABSTRACT

BACKGROUND: Implantable Cardiac Monitors (ICMs) are used for long-term monitoring of arrhythmias. BIOMONITOR III is a novel ICM with a miniaturized profile, long sensing vector due to a flexible antenna, simplified implantation with a dedicated insertion tool for pocket formation and ICM placement in a single step, and daily automatic Home Monitoring (HM) function. METHODS: In 47 patients undergoing BIOMONITOR III insertion for any ICM indication, 16 investigators at 10 Australian sites assessed handling characteristics of the insertion tool, R-wave amplitudes, noise burden, P-wave visibility, and HM transmission success. Patients were followed for 1 month. RESULTS: All 47 attempted insertions were successful. Median time from skin incision to removal of the insertion tool after ICM insertion was 39 s (IQR 19-65) and to wound closure and cleaning was 4.7 min (IQR 3.5-7.8). All aspects of the insertion tool were rated as "good" or "excellent" in ≥97.9% and "fair" in ≤2.1% of patients, except for "force needed for tunnelling" (91.5% good/excellent, 8.5% fair). Based on HM data, R-waves in the first month were stable at 0.70 ± 0.37 mV. Median noise burden (disabling automatic rhythm evaluation) was 0.19% (IQR 0.00-0.93), equivalent to 2.7 min (IQR 0.0-13.4) per day. In HM-transmitted ECG strips with regular sinus rhythm, P-waves were visible in 89 ± 24% of heart cycles. Patient-individual automatic Home Monitoring transmission success was 98.0% ± 5.5%. CONCLUSIONS: The novel ICM performed well in all aspects studied, including fast insertion, reliable R-wave sensing, good P-wave visibility, and highly successful HM transmissions.


Subject(s)
Electrocardiography, Ambulatory , Electrocardiography , Arrhythmias, Cardiac/diagnosis , Australia , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...