Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 17(1)2017 Jan 07.
Article in English | MEDLINE | ID: mdl-28067854

ABSTRACT

Due to a lack of appropriate image resolution, most ultrasound scanners are unable to sensitively discern the pulley tissues. To extensively investigate the properties of the A1 pulley system and the surrounding tissues for assessing trigger finger, a 30 MHz ultrasound system was implemented to perform in vitro experiments using the hypodermis, A1 pulley, and superficial digital flexor tendon (SDFT) dissected from cadavers. Ultrasound signals were acquired from both the transverse and sagittal planes of each tissue sample. The quantitative ultrasonic parameters, including sound speed, attenuation coefficient, integrated backscatter (IB) and Nakagami parameter (m), were subsequently estimated to characterize the tissue properties. The results demonstrated that the acquired ultrasound images have high resolution and are able to sufficiently differentiate the variations of tissue textures. Moreover, the attenuation slope of the hypodermis is larger than those of the A1 pulley and SDFT. The IB of A1 pulley is about the same as that of the hypodermis, and is very different from SDFT. The m parameter of the A1 pulley is also very different from those of hypodermis and SDFT. This study demonstrated that high-frequency ultrasound images in conjunction with ultrasonic parameters are capable of characterizing the A1 pulley system and surrounding tissues.


Subject(s)
Ultrasonography , Cadaver , Humans , Sound , Tendons , Trigger Finger Disorder
2.
Biomed Res Int ; 2016: 6893712, 2016.
Article in English | MEDLINE | ID: mdl-27034946

ABSTRACT

Muscle strain is still awanting a noninvasive quantitatively diagnosis tool. High frequency ultrasound (HFU) improves image resolution for monitoring changes of tissue structures, but the biomechanical factors may influence ultrasonography during injury detection. We aim to illustrate the ultrasonic parameters to present the histological damage of overstretched muscle with the consideration of biomechanical factors. Gastrocnemius muscles from mice were assembled and ex vivo passive stretching was performed before or after injury. After injury, the muscle significantly decreased mechanical strength. Ultrasonic images were obtained by HFU at different deformations to scan in cross and longitudinal orientations of muscle. The ultrasonography was quantified by echogenicity and Nakagami parameters (NP) for structural evaluation and correlated with histological results. The injured muscle at its original length exhibited decreased echogenicity and NP from HFU images. Cross-sectional ultrasonography revealed a loss of correlation between NP and passive muscle stretching that suggested a special scatterer pattern in the cross section of injured muscle. The independence of NP during passive stretching of injured muscle was confirmed by histological findings in ruptured collagen fibers, decreased muscle density, and increased intermuscular fiber space. Thus, HFU analysis of NP in cross section represents muscle injury that may benefit the clinical diagnosis.


Subject(s)
Muscle Fibers, Skeletal/pathology , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/injuries , Ultrasonography , Animals , Humans , Mechanical Phenomena , Mice , Muscle Fibers, Skeletal/ultrastructure , Muscle, Skeletal/pathology
3.
Ultrasound Med Biol ; 42(5): 1075-83, 2016 May.
Article in English | MEDLINE | ID: mdl-26831343

ABSTRACT

The purpose was to identify the A1 pulley's exact location and thickness by comparing measurements from a clinical high-frequency ultrasound scanner system (CHUS), a customized high-frequency ultrasound imaging research system (HURS) and a digital caliper. Ten cadaveric hands were used. We explored the pulley by layers, inserted guide pins and scanned it with the CHUS. After identifying the pulley, we measured each long finger's thickness using the CHUS and excised the pulley to measure its thickness with a digital caliper and the HURS. The thin hypo-echoic layer was revealed to be the synovial fluid space, and the pulley appears hyper-echoic regardless of scan direction. We also defined the pulley's boundaries. Moreover, the CHUS provided a significantly lower measurement of the pulley's thickness than the digital caliper and HURS. Likewise, based on the digital caliper's measurement, the HURS had significantly lower mean absolute and relative errors than the CHUS.


Subject(s)
Finger Joint/anatomy & histology , Finger Joint/diagnostic imaging , Physical Examination/methods , Tendons/anatomy & histology , Tendons/diagnostic imaging , Ultrasonography/methods , Anatomic Landmarks/anatomy & histology , Anatomic Landmarks/diagnostic imaging , Cadaver , Female , Humans , Image Interpretation, Computer-Assisted/methods , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Taiwan
4.
Sensors (Basel) ; 14(5): 7738-52, 2014 Apr 28.
Article in English | MEDLINE | ID: mdl-24787637

ABSTRACT

Carpal tunnel syndrome (CTS) is typically diagnosed by physical examination or nerve conduction measurements. With these diagnostics however it is difficult to obtain anatomical information in the carpal tunnel. To further improve the diagnosis of CTS, an attempt using 30 MHz high-frequency ultrasound to noninvasively detect the local anatomical structures and the kinetic trajectory of the median nerve (MN) in the wrist was explored. Measurements were performed on the right wrist of 14 asymptomatic volunteers. The kinetic trajectory of the MN corresponding to flexion (from 0° to 90°) and extension (from 90° to 0°) movements of the fingers were detected by a cross correlation-based motion tracking technique. The average displacements of the MN according to finger movements were measured to be 3.74 and 2.04 mm for male and female subjects, respectively. Moreover, the kinetic trajectory of the MN in both the ulnar-palmar and total directions generally follows a sigmoidal curve tendency. This study has verified that the use of high-frequency ultrasound imaging and a motion tracking technique to sensitively detect the displacement and kinetic trajectory of the MN for the assessment of CTS patients is feasible.


Subject(s)
Finger Joint/diagnostic imaging , Finger Joint/physiology , Image Interpretation, Computer-Assisted/methods , Median Nerve/diagnostic imaging , Median Nerve/physiology , Range of Motion, Articular/physiology , Ultrasonography/methods , Adult , Equipment Design , Equipment Failure Analysis , Female , Fiducial Markers , Humans , Image Interpretation, Computer-Assisted/instrumentation , Male , Reproducibility of Results , Sensitivity and Specificity , Ultrasonography/instrumentation
5.
Ultrasonics ; 54(1): 177-86, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23871514

ABSTRACT

Bone fracture induces moderate inflammatory responses that are regulated by cyclooxygenase-2 (COX-2) or 5-lipoxygenase (5-LO) for initiating tissue repair and bone formation. Only a handful of non-invasive techniques focus on monitoring acute inflammation of injured bone currently exists. In the current study, we monitored in vivo inflammation levels during the initial 2 weeks of the inflammatory stage after mouse bone fracture utilizing 50 MHz ultrasound. The acquired ultrasonic images were correlated well with histological examinations. After the bone fracture in the tibia, dynamic changes in the soft tissue at the medial-posterior compartment near the fracture site were monitored by ultrasound on the days of 0, 2, 4, 7, and 14. The corresponding echogenicity increased on the 2nd, 4th, and 7th day, and subsequently declined to basal levels after the 14th day. An increase of cell death was identified by the positive staining of deoxynucleotidyl transferase dUTP nick end-labeling (TUNEL) assay and was consistent with ultrasound measurements. The increases of both COX-2 and Leukotriene B4 receptor 1 (BLT1, 5-LO-relative receptor), which are regulators for tissue inflammation, in the immunohistochemistry staining revealed their involvement in bone fracture injury. Monitoring the inflammatory response to various non-steroidal anti-inflammatory drugs (NSAIDs) treatments was investigated by treating injured mice with a daily oral intake of aspirin (Asp), indomethacin (IND), and a selective COX-2 inhibitor (SC-236). The Asp treatment significantly reduced fracture-increased echogenicity (hyperechogenicity, p<0.05) in ultrasound images as well as inhibited cell death, and expression of COX-2 and BLT1. In contrast, treatment with IND or SC-236 did not reduce the hyperechogenicity, as confirmed by cell death (TUNEL) and expression levels of COX-2 or BLT1. Taken together, the current study reports the feasibility of a non-invasive ultrasound method capable of monitoring post-fracture tissue inflammation that positively correlates with histological findings. Results of this study also suggest that this approach may be further applied to elucidate the underlying mechanisms of inflammatory processes and to develop therapeutic strategies for facilitating fracture healing.


Subject(s)
Anti-Inflammatory Agents/therapeutic use , Cytokines/immunology , Osteitis/diagnostic imaging , Osteitis/drug therapy , Tibial Fractures/diagnostic imaging , Tibial Fractures/drug therapy , Ultrasonography/methods , Animals , Early Diagnosis , Fracture Healing/drug effects , Mice , Osteitis/immunology , Tibial Fractures/immunology , Treatment Outcome
6.
J Memb Sci ; 433: 100-111, 2013 Apr 15.
Article in English | MEDLINE | ID: mdl-25309028

ABSTRACT

A 50 MHz high-frequency ultrasound and analysis method were developed to further improve the in situ assessment of deposition and distribution of organic fouling on the polyvinylidene fluoride (PVDF) membranes. Measurements of fouling depositions were performed from PVDF membranes filtrated with aqueous humic acid solutions (HAS) of 2 and 4 ppm concentrations in a flat-sheet module. Ultrasound signals reflected from the PVDF membranes, following filtrations at various durations including 0, 5, 15, 30, 60, and 100 min, were acquired. The thickness and distribution of fouling estimated and assessed by peak-to-peak echo voltage (Vpp) and C-mode images were found to be non-homogeneously deposited on the membranes. Following the filtrations with 2 and 4 ppm HAS for 100 min, the corresponding thickness of fouling deposition increased from 1.81±9 to 2.4571.57 mm, respectively; those average Vpp decreased from 2.05±07 to 1.13±16 V and from 2.11±08 to 0.94±15 V. These results demonstrated that the deposition and distribution of organic fouling could be sensitively and rapidly evaluated by high-frequency ultrasound image incorporated with the analysis method.

7.
Article in English | MEDLINE | ID: mdl-22622982

ABSTRACT

Conductive polymer composites, typically fabricated from a mix of conductive fillers and a polymer substrate, are commonly applied as bipolar plates in a fuel cell stack. Electrical conductivity is a crucial property that greatly depends on the distribution and orientation of the fillers. In this study, a 50-MHz ultrasound imaging system and analysis techniques capable of nondestructively assessing the properties of carbon fibers (CFs) in conductive polymer composites were developed. Composite materials containing a mix of polycarbonate substrates and 0 to 0.3 wt% of CFs were prepared using an injection molding technique. Ultrasonic A-line signals and C-scan images were acquired from each composite sample in regions at a depth of 0.15 mm beneath the sample surface (region A) and those at a depth of 0.3 mm (region B). The integrated backscatter (IB) and the Nakagami statistical parameter were calculated to quantitatively assess the samples. The area ratio, defined as the percentage of areas composed of CF images normalized by that of the whole C-scan image, was applied to further quantify the orientation of CFs perpendicular to the sample surface. Corresponding to the increase in CF concentrations from 0.1 to 0.3 wt%, the average IB and Nakagami parameter (m) of the composite samples increased from -78.10 ± 2.20 (mean ± standard deviation) to -72.66 ± 1.40 dB and from 0.024 ± 0.012 to 0.048 ± 0.011, respectively. The corresponding area ratios were respectively estimated to be 0.78 ± 0.35%, 2.33 ± 0.66%, and 2.20 ± 0.60% in region A of the samples; those of CFs with a perpendicular orientation were 0.04 ± 0.03%, 0.08 ± 0.02%, and 0.12 ± 0.05%. The area ratios in region B of the samples were calculated to be 1.19 ± 0.54%, 2.81 ± 0.42%, and 2.64 ± 0.76%, and those of CFs with a perpendicular orientation were 0.07 ± 0.04%, 0.12 ± 0.04%, and 0.14 ± 0.03%. According to the results of the orientations and ultrasonic images, CFs tended to distribute more uniformly in the deeper regions of the samples. This study validates that the distribution and orientation of CFs in conductive polymer composites could be sensitively and quantitatively assessed by high-frequency ultrasound in conjunction with current analysis methods.


Subject(s)
Carbon/chemistry , Polycarboxylate Cement/chemistry , Sound , Carbon Fiber , Electric Conductivity , Radio Waves
8.
Phys Med Biol ; 56(3): 757-73, 2011 Feb 07.
Article in English | MEDLINE | ID: mdl-21239847

ABSTRACT

An accurate and quantitative modality to assess the burn degree is crucial for determining further treatments to be properly applied to burn injury patients. Ultrasounds with frequencies higher than 20 MHz have been applied to dermatological diagnosis due to its high resolution and noninvasive capability. Yet, it is still lacking a substantial means to sensitively correlate the burn degree and ultrasonic measurements quantitatively. Thus, a 50 MHz ultrasound system was developed and implemented to measure ultrasonic signals backscattered from the burned skin tissues. Various burn degrees were achieved by placing a 100 °C brass plate onto the dorsal skins of anesthetized rats for various durations ranged from 5 to 20 s. The burn degrees were correlated with ultrasonic parameters, including integrated backscatter (IB) and Nakagami parameter (m) calculated from ultrasonic signals acquired from the burned tissues of a 5 × 1.4 mm (width × depth) area. Results demonstrated that both IB and m decreased exponentially with the increase of burn degree. Specifically, an IB of -79.0 ± 2.4 (mean ± standard deviation) dB for normal skin tissues tended to decrease to -94.0 ± 1.3 dB for those burned for 20 s, while the corresponding Nakagami parameters tended to decrease from 0.76 ± 0.08 to 0.45 ± 0.04. The variation of both IB and m was partially associated with the change of properties of collagen fibers from the burned tissues verified by samples of tissue histological sections. Particularly, the m parameter may be more sensitive to differentiate burned skin due to the fact that it has a greater rate of change with respect to different burn durations. These ultrasonic parameters in conjunction with high-frequency B-mode and Nakagami images could have the potential to assess the burn degree quantitatively.


Subject(s)
Burns/diagnostic imaging , Burns/pathology , Models, Statistical , Ultrasonography/methods , Animals , Female , Rats , Rats, Wistar , Skin/diagnostic imaging , Skin/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...