Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Bioengineering (Basel) ; 11(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38790322

ABSTRACT

Detection and segmentation of brain metastases (BMs) play a pivotal role in diagnosis, treatment planning, and follow-up evaluations for effective BM management. Given the rising prevalence of BM cases and its predominantly multiple onsets, automated segmentation is becoming necessary in stereotactic radiosurgery. It not only alleviates the clinician's manual workload and improves clinical workflow efficiency but also ensures treatment safety, ultimately improving patient care. Recent strides in machine learning, particularly in deep learning (DL), have revolutionized medical image segmentation, achieving state-of-the-art results. This review aims to analyze auto-segmentation strategies, characterize the utilized data, and assess the performance of cutting-edge BM segmentation methodologies. Additionally, we delve into the challenges confronting BM segmentation and share insights gleaned from our algorithmic and clinical implementation experiences.

2.
Bioresour Technol ; 395: 130400, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38286169

ABSTRACT

The rational use of bamboo to make dissolving pulp can offer up new opportunities for cellulose production, alleviating wood scarcity. Bamboo contains a high content of non-fiber cells, which presents technical challenges in dissolving pulp production by the conventional process. In this study, a process concept of separating hemicelluloses is presented by fiber fractionation and purification for cleaner production of bamboo dissolving pulp: bamboo kraft pulp was fractionated into long-fiber and short-fiber fractions. The cellulose-rich long-fiber fraction was converted to dissolving pulp by further purification treatment with acid hydrolysis and cold caustic extraction. The hemicellulose-rich short-fiber fraction was used for papermaking. The laboratory results were confirmed by those from mill trials. The combined pulp yield (dissolving pulp + paper-grade pulp) reached 49 %, which was significantly higher than that of the conventional pre-hydrolysis kraft pulping process. Furthermore, the quality of dissolving pulp was higher due to inherently higher cellulose content of long-fiber fraction.


Subject(s)
Cellulose , Chemical Fractionation , Wood , Hydrolysis
3.
Med Phys ; 51(4): 2526-2537, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38014764

ABSTRACT

BACKGROUND: Volumetric reconstruction of magnetic resonance imaging (MRI) from sparse samples is desirable for 3D motion tracking and promises to improve magnetic resonance (MR)-guided radiation treatment precision. Data-driven sparse MRI reconstruction, however, requires large-scale training datasets for prior learning, which is time-consuming and challenging to acquire in clinical settings. PURPOSE: To investigate volumetric reconstruction of MRI from sparse samples of two orthogonal slices aided by sparse priors of two static 3D MRI through implicit neural representation (NeRP) learning, in support of 3D motion tracking during MR-guided radiotherapy. METHODS: A multi-layer perceptron network was trained to parameterize the NeRP model of a patient-specific MRI dataset, where the network takes 4D data coordinates of voxel locations and motion states as inputs and outputs corresponding voxel intensities. By first training the network to learn the NeRP of two static 3D MRI with different breathing motion states, prior information of patient breathing motion was embedded into network weights through optimization. The prior information was then augmented from two motion states to 31 motion states by querying the optimized network at interpolated and extrapolated motion state coordinates. Starting from the prior-augmented NeRP model as an initialization point, we further trained the network to fit sparse samples of two orthogonal MRI slices and the final volumetric reconstruction was obtained by querying the trained network at 3D spatial locations. We evaluated the proposed method using 5-min volumetric MRI time series with 340 ms temporal resolution for seven abdominal patients with hepatocellular carcinoma, acquired using golden-angle radial MRI sequence and reconstructed through retrospective sorting. Two volumetric MRI with inhale and exhale states respectively were selected from the first 30 s of the time series for prior embedding and augmentation. The remaining 4.5-min time series was used for volumetric reconstruction evaluation, where we retrospectively subsampled each MRI to two orthogonal slices and compared model-reconstructed images to ground truth images in terms of image quality and the capability of supporting 3D target motion tracking. RESULTS: Across the seven patients evaluated, the peak signal-to-noise-ratio between model-reconstructed and ground truth MR images was 38.02 ± 2.60 dB and the structure similarity index measure was 0.98 ± 0.01. Throughout the 4.5-min time period, gross tumor volume (GTV) motion estimated by deforming a reference state MRI to model-reconstructed and ground truth MRI showed good consistency. The 95-percentile Hausdorff distance between GTV contours was 2.41 ± 0.77 mm, which is less than the voxel dimension. The mean GTV centroid position difference between ground truth and model estimation was less than 1 mm in all three orthogonal directions. CONCLUSION: A prior-augmented NeRP model has been developed to reconstruct volumetric MRI from sparse samples of orthogonal cine slices. Only one exhale and one inhale 3D MRI were needed to train the model to learn prior information of patient breathing motion for sparse image reconstruction. The proposed model has the potential of supporting 3D motion tracking during MR-guided radiotherapy for improved treatment precision and promises a major simplification of the workflow by eliminating the need for large-scale training datasets.


Subject(s)
Abdomen , Magnetic Resonance Imaging , Humans , Retrospective Studies , Motion , Respiration , Magnetic Resonance Spectroscopy , Imaging, Three-Dimensional
4.
IEEE Trans Pattern Anal Mach Intell ; 45(11): 13408-13421, 2023 11.
Article in English | MEDLINE | ID: mdl-37363838

ABSTRACT

Defining the loss function is an important part of neural network design and critically determines the success of deep learning modeling. A significant shortcoming of the conventional loss functions is that they weight all regions in the input image volume equally, despite the fact that the system is known to be heterogeneous (i.e., some regions can achieve high prediction performance more easily than others). Here, we introduce a region-specific loss to lift the implicit assumption of homogeneous weighting for better learning. We divide the entire volume into multiple sub-regions, each with an individualized loss constructed for optimal local performance. Effectively, this scheme imposes higher weightings on the sub-regions that are more difficult to segment, and vice versa. Furthermore, the regional false positive and false negative errors are computed for each input image during a training step and the regional penalty is adjusted accordingly to enhance the overall accuracy of the prediction. Using different public and in-house medical image datasets, we demonstrate that the proposed regionally adaptive loss paradigm outperforms conventional methods in the multi-organ segmentations, without any modification to the neural network architecture or additional data preparation.


Subject(s)
Algorithms , Neural Networks, Computer , Image Processing, Computer-Assisted/methods
5.
Med Phys ; 50(5): 3137-3147, 2023 May.
Article in English | MEDLINE | ID: mdl-36621812

ABSTRACT

BACKGROUND: Linear accelerator (Linac) beam data commissioning and quality assurance (QA) play a vital role in accurate radiation treatment delivery and entail a large number of measurements using a variety of field sizes. How to optimize the effort in data acquisition while maintaining high quality of medical physics practice has been sought after. PURPOSE: We propose to model Linac beam data through implicit neural representation (NeRP) learning. The potential of the beam model in predicting beam data from sparse measurements and detecting data collection errors was evaluated, with the goal of using the beam model to verify beam data collection accuracy and simplify the commissioning and QA process. MATERIALS AND METHODS: NeRP models with continuous and differentiable functions parameterized by multilayer perceptrons (MLPs) were used to represent various beam data including percentage depth dose (PDD) and profiles of 6 MV beams with and without flattening filter. Prior knowledge of the beam data was embedded into the MLP network by learning the NeRP of a vendor-provided "golden" beam dataset. The prior-embedded network was then trained to fit clinical beam data collected at one field size and used to predict beam data at other field sizes. We evaluated the prediction accuracy by comparing network-predicted beam data to water tank measurements collected from 14 clinical Linacs. Beam datasets with intentionally introduced errors were used to investigate the potential use of the NeRP model for beam data verification, by evaluating the model performance when trained with erroneous beam data samples. RESULTS: Linac beam data predicted by the model agreed well with water tank measurements, with averaged Gamma passing rates (1%/1 mm passing criteria) higher than 95% and averaged mean absolute errors less than 0.6%. Beam data samples with measurement errors were revealed by inconsistent beam predictions between networks trained with correct versus erroneous data samples, characterized by a Gamma passing rate lower than 90%. CONCLUSION: A NeRP beam data modeling technique has been established for predicting beam characteristics from sparse measurements. The model provides a valuable tool to verify beam data collection accuracy and promises to simplify commissioning/QA processes by reducing the number of measurements without compromising the quality of medical physics service.


Subject(s)
Radiotherapy, Intensity-Modulated , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Particle Accelerators , Water
6.
Med Phys ; 49(9): 6110-6119, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35766221

ABSTRACT

PURPOSE: To develop a geometry-informed deep learning framework for volumetric MRI with sub-second acquisition time in support of 3D motion tracking, which is highly desirable for improved radiotherapy precision but hindered by the long image acquisition time. METHODS: A 2D-3D deep learning network with an explicitly defined geometry module that embeds geometric priors of the k-space encoding pattern was investigated, where a 2D generation network first augmented the sparsely sampled image dataset by generating new 2D representations of the underlying 3D subject. A geometry module then unfolded the 2D representations to the volumetric space. Finally, a 3D refinement network took the unfolded 3D data and outputted high-resolution volumetric images. Patient-specific models were trained for seven abdominal patients to reconstruct volumetric MRI from both orthogonal cine slices and sparse radial samples. To evaluate the robustness of the proposed method to longitudinal patient anatomy and position changes, we tested the trained model on separate datasets acquired more than one month later and evaluated 3D target motion tracking accuracy using the model-reconstructed images by deforming a reference MRI with gross tumor volume (GTV) contours to a 5-min time series of both ground truth and model-reconstructed volumetric images with a temporal resolution of 340 ms. RESULTS: Across the seven patients evaluated, the median distances between model-predicted and ground truth GTV centroids in the superior-inferior direction were 0.4 ± 0.3 mm and 0.5 ± 0.4 mm for cine and radial acquisitions, respectively. The 95-percentile Hausdorff distances between model-predicted and ground truth GTV contours were 4.7 ± 1.1 mm and 3.2 ± 1.5 mm for cine and radial acquisitions, which are of the same scale as cross-plane image resolution. CONCLUSION: Incorporating geometric priors into deep learning model enables volumetric imaging with high spatial and temporal resolution, which is particularly valuable for 3D motion tracking and has the potential of greatly improving MRI-guided radiotherapy precision.


Subject(s)
Deep Learning , Radiotherapy, Image-Guided , Humans , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging , Motion , Radiotherapy, Image-Guided/methods
7.
Phys Med Biol ; 66(17)2021 09 03.
Article in English | MEDLINE | ID: mdl-34412047

ABSTRACT

Abdominal organ motions introduce geometric uncertainties to radiotherapy. This study investigates a multi-temporal resolution 3D motion prediction scheme that accounts for both breathing and slow drifting motion in the abdomen in support of MRI-guided radiotherapy. Ten-minute MRI scans were acquired for 8 patients using a volumetric golden-angle stack-of-stars sequence. The first five-minutes was used for patient-specific motion modeling. Fast breathing motion was modeled from high temporal resolution radial k-space samples, which served as a navigator signal to sort k-space data into different bins for high spatial resolution reconstruction of breathing motion states. Slow drifting motion was modeled from a lower temporal resolution image time series which was reconstructed by sequentially combining a large number of breathing-corrected k-space samples. Principal components analysis (PCA) was performed on deformation fields between different motion states. Gaussian kernel regression and linear extrapolation were used to predict PCA coefficients of future motion states for breathing motion (340 ms ahead of acquisition) and slow drifting motion (8.5 s ahead of acquisition) respectively. k-space data from the remaining five-minutes was used to compare ground truth motions states obtained from retrospective reconstruction/deformation with predictions. Median distances between predicted and ground truth centroid positions of gross tumor volume (GTV) and organs at risk (OARs) were less than 1 mm on average. 95- percentile Hausdorff distances between predicted and ground truth GTV contours of various breathing motions states were 2 mm on average, which was smaller than the imaging resolution and 95-percentile Hausdorff distances between predicted and ground truth OAR contours of different slow drifting motion states were less than 0.2 mm. These results suggest that multi-temporal resolution motion models are capable of volumetric predictions of breathing and slow drifting motion with sufficient accuracy and temporal resolution for MRI-based tracking, and thus have potential for supporting MRI-guided abdominal radiotherapy.


Subject(s)
Abdomen , Magnetic Resonance Imaging , Respiration , Abdomen/diagnostic imaging , Humans , Imaging, Three-Dimensional , Motion , Retrospective Studies
8.
Phys Med Biol ; 66(8)2021 04 12.
Article in English | MEDLINE | ID: mdl-33725676

ABSTRACT

Abdominal organ motions introduce geometric uncertainties to gastrointestinal radiotherapy. This study investigated slow drifting motion induced by changes of internal anatomic organ arrangements using a 3D radial MRI sequence with a scan length of 20 min. Breathing motion and cyclic GI motion were first removed through multi-temporal resolution image reconstruction. Slow drifting motion analysis was performed using an image time series consisting of 72 image volumes with a temporal sampling rate of 17 s. B-spline deformable registration was performed to align image volumes of the time series to a reference volume. The resulting deformation fields were used for motion velocity evaluation and patient-specific motion model construction through principal component analysis (PCA). Geometric uncertainties introduced by slow drifting motion were assessed by Hausdorff distances between unions of organs at risk (OARs) at different motion states and reference OAR contours as well as probabilistic distributions of OARs predicted using the PCA model. Thirteen examinations from 11 patients were included in this study. The averaged motion velocities ranged from 0.8 to 1.9 mm min-1, 0.7 to 1.6 mm min-1, 0.6 to 2.0 mm min-1and 0.7 to 1.4 mm min-1for the small bowel, colon, duodenum and stomach respectively; the averaged Hausdorff distances were 5.6 mm, 5.3 mm, 5.1 mm and 4.6 mm. On average, a margin larger than 4.5 mm was needed to cover a space with OAR occupancy probability higher than 55%. Temporal variations of geometric uncertainties were evaluated by comparing across four 5 min sub-scans extracted from the full scan. Standard deviations of Hausdorff distances across sub-scans were less than 1 mm for most examinations, indicating stability of relative margin estimates from separate time windows. These results suggested slow drifting motion of GI organs is significant and geometric uncertainties introduced by such motion should be accounted for during radiotherapy planning and delivery.


Subject(s)
Magnetic Resonance Imaging , Respiration , Humans , Image Processing, Computer-Assisted , Motion , Organs at Risk
9.
Phys Med Biol ; 65(12): 125001, 2020 06 15.
Article in English | MEDLINE | ID: mdl-32330923

ABSTRACT

Magnetic resonance imaging (MRI) is gaining popularity in guiding radiation treatment for intrahepatic cancers due to its superior soft tissue contrast and potential of monitoring individual motion and liver function. This study investigates a deep learning-based method that generates synthetic CT volumes from T1-weighted MR Dixon images in support of MRI-based intrahepatic radiotherapy treatment planning. Training deep neutral networks for this purpose has been challenged by mismatches between CT and MR images due to motion and different organ filling status. This work proposes to resolve such challenge by generating 'semi-synthetic' CT images from rigidly aligned CT and MR image pairs. Contrasts within skeletal elements of the 'semi-synthetic' CT images were determined from CT images, while contrasts of soft tissue and air volumes were determined from voxel-wise intensity classification results on MR images. The resulting 'semi-synthetic' CT images were paired with their corresponding MR images and used to train a simple U-net model without adversarial components. MR and CT scans of 46 patients were investigated and the proposed method was evaluated for 31 patients with clinical radiotherapy plans, using 3-fold cross validation. The averaged mean absolute errors between synthetic CT and CT images across patients were 24.10 HU for liver, 28.62 HU for spleen, 47.05 HU for kidneys, 29.79 HU for spinal cord, 105.68 HU for lungs and 110.09 HU for vertebral bodies. VMAT and IMRT plans were optimized using CT-derived electron densities, and doses were recalculated using corresponding synthetic CT-derived density grids. Resulting dose differences to planning target volumes and various organs at risk were small, with the average difference less than 0.15 Gy for all dose metrics evaluated. The similarities in both image intensity and radiation dose distributions between CT and synthetic CT volumes demonstrate the accuracy of the method and its potential in supporting MRI-only radiotherapy treatment planning.


Subject(s)
Liver Neoplasms/radiotherapy , Magnetic Resonance Imaging/methods , Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Abdomen/diagnostic imaging , Humans , Radiotherapy Dosage
10.
Phys Med Biol ; 62(8): 2922-2934, 2017 04 21.
Article in English | MEDLINE | ID: mdl-28306547

ABSTRACT

A technique for generating MRI-derived synthetic CT volumes (MRCTs) is demonstrated in support of adaptive liver stereotactic body radiation therapy (SBRT). Under IRB approval, 16 subjects with hepatocellular carcinoma were scanned using a single MR pulse sequence (T1 Dixon). Air-containing voxels were identified by intensity thresholding on T1-weighted, water and fat images. The envelope of the anterior vertebral bodies was segmented from the fat image and fuzzy-C-means (FCM) was used to classify each non-air voxel as mid-density, lower-density, bone, or marrow in the abdomen, with only bone and marrow classified within the vertebral body envelope. MRCT volumes were created by integrating the product of the FCM class probability with its assigned class density for each voxel. MRCTs were deformably aligned with corresponding planning CTs and 2-ARC-SBRT-VMAT plans were optimized on MRCTs. Fluence was copied onto the CT density grids, dose recalculated, and compared. The liver, vertebral bodies, kidneys, spleen and cord had median Hounsfield unit differences of less than 60. Median target dose metrics were all within 0.1 Gy with maximum differences less than 0.5 Gy. OAR dose differences were similarly small (median: 0.03 Gy, std:0.26 Gy). Results demonstrate that MRCTs derived from a single abdominal imaging sequence are promising for use in SBRT dose calculation.


Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Cone-Beam Computed Tomography/methods , Liver Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Aged , Aged, 80 and over , Carcinoma, Hepatocellular/radiotherapy , Female , Humans , Liver Neoplasms/radiotherapy , Male , Middle Aged , Radiotherapy Dosage
11.
Phys Med Biol ; 62(8): 2935-2949, 2017 04 21.
Article in English | MEDLINE | ID: mdl-28306550

ABSTRACT

Using MRI for radiotherapy treatment planning and image guidance is appealing as it provides superior soft tissue information over CT scans and avoids possible systematic errors introduced by aligning MR to CT images. This study presents a method that generates Synthetic CT (MRCT) volumes by performing probabilistic tissue classification of voxels from MRI data using a single imaging sequence (T1 Dixon). The intensity overlap between different tissues on MR images, a major challenge for voxel-based MRCT generation methods, is addressed by adding bone shape information to an intensity-based classification scheme. A simple pelvic bone shape model, built from principal component analysis of pelvis shape from 30 CT image volumes, is fitted to the MR volumes. The shape model generates a rough bone mask that excludes air and covers bone along with some surrounding soft tissues. Air regions are identified and masked out from the tissue classification process by intensity thresholding outside the bone mask. A regularization term is added to the fuzzy c-means classification scheme that constrains voxels outside the bone mask from being assigned memberships in the bone class. MRCT image volumes are generated by multiplying the probability of each voxel being represented in each class with assigned attenuation values of the corresponding class and summing the result across all classes. The MRCT images presented intensity distributions similar to CT images with a mean absolute error of 13.7 HU for muscle, 15.9 HU for fat, 49.1 HU for intra-pelvic soft tissues, 129.1 HU for marrow and 274.4 HU for bony tissues across 9 patients. Volumetric modulated arc therapy (VMAT) plans were optimized using MRCT-derived electron densities, and doses were recalculated using corresponding CT-derived density grids. Dose differences to planning target volumes were small with mean/standard deviation of 0.21/0.42 Gy for D0.5cc and 0.29/0.33 Gy for D99%. The results demonstrate the accuracy of the method and its potential in supporting MRI only radiotherapy treatment planning.


Subject(s)
Pelvic Bones/diagnostic imaging , Pelvic Neoplasms/diagnostic imaging , Pelvic Neoplasms/radiotherapy , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Female , Humans , Magnetic Resonance Imaging/methods , Models, Theoretical , Pelvic Neoplasms/pathology , Prospective Studies , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
12.
Phys Med Biol ; 61(1): 169-82, 2016 Jan 07.
Article in English | MEDLINE | ID: mdl-26624989

ABSTRACT

Separating bone from air in MR data is one of the major challenges in using MR images to derive synthetic CT. The problem is further complicated when the anatomic regions filled with air are altered across scans due to air mobility, for instance, in pelvic regions, thereby the air regions estimated using an ultrashort echo time (UTE) sequence are invalid in other image series acquired for multispectral classification. This study aims to develop and investigate a female pelvic bone shape model to identify low intensity regions in MRI where air is unlikely to be present in support of synthetic CT generation without UTE imaging. CT scans of 30 patients were collected for the study, 17 of them also have corresponding MR scans. The shape model was built from the CT dataset, where the reference image was aligned to each of the training images using B-spline deformable registration. Principal component analysis was performed on B-spline coefficients for a compact model where shape variance was described by linear combination of principal modes. The model was applied to identify pelvic bone in MR images by deforming the corresponding MR data of the reference image to target MR images, where the search space of the deformation process was constrained within the subspace spanned by principal modes. The local minima in the search space were removed effectively by the shape model, thus supporting an efficient binary search for the optimal solution. We evaluated the model by its efficacy in identifying bone voxels and excluding air regions. The model was tested across the 17 patients that have corresponding MR scans using a leave-one-out cross validation. A simple model using the first leading principal mode only was found to achieve reasonable accuracy, where an averaged 87% of bone voxels were correctly identified. Finally dilation of the optimally fit bone mask by 5 mm was found to cover 96% of bone voxels while minimally impacting the overlap with air (below 0.4%).


Subject(s)
Pelvic Bones/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Female , Humans , Models, Theoretical
13.
J Hazard Mater ; 185(2-3): 1264-72, 2011 Jan 30.
Article in English | MEDLINE | ID: mdl-21071139

ABSTRACT

In this paper, a novel inorganic polymer coagulant was prepared from oil shale ash, and was adopted to treat municipal sewage. Effect of coagulants dosage on the turbidity and Chemical Oxygen Demand (COD) removal were examined. In addition, the structure and morphology of the prepared coagulants were characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD) and infra-red spectra (FTIR), furthermore, the zeta potential of the sewage and the microscopic images of flocks were measured. The results indicate that the characterization and coagulation performance of the samples are affected by Al/Fe mole ratios and the type of lixiviant. The most of Fe(3+) is not turned into the crystals, which means that the samples are not simple mixtures of raw materials but inorganic polymer compounds with iron, aluminum, silicon and other ions. When Al/Fe mole ratio is 0.71 or the 2HCl/H(2)SO(4) mole ratio of the lixiviant is 1:1, the coagulation performance of the sample is better than that of the others. The integrated analysis suggests that the entrapment, adsorption and complexation abilities play important roles in coagulation process although the charge neutralization is weak. Also, the chain-net structure and the suitable size of polymer group are favorable for the entrapment, adsorption and complexation ability of the samples.


Subject(s)
Inorganic Chemicals/chemistry , Petroleum , Polymers/chemistry , Microscopy, Electron, Transmission , Spectroscopy, Fourier Transform Infrared , X-Ray Diffraction
SELECTION OF CITATIONS
SEARCH DETAIL
...