Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Rev. lab. clín ; 9(4): 147-158, oct.-dic. 2016. tab
Article in English | IBECS | ID: ibc-158431

ABSTRACT

Introduction. The selection and definition of quality indicators is essential for proper control of processes. This is not always easy, particularly with extra-analytical indicators, due to the complexity and degree of comparison of processes between laboratories, and the fact that data collection is not always automated. For this reason, the indicators and specifications need to be dynamic and re-designed in accordance with changes in the system. The aim of this paper is to describe the methodology used in the selection and definition of quality indicators, and their specifications for extra-analytical processes in public laboratories in Catalonia. Material and methods. During the study period (2004-2013), the members of the working group reported the mean annual value for each indicator, and the overall yearly mean of all participants was calculated. These results were compared and analyzed during periodic meetings, with regards to the pre-established specifications of the different laboratories. Results. Quality indicators and their specifications are presented. The evaluation of the validity of each quality indicator was made taking into account aspects including usefulness of the indicator in process monitoring, a clear definition, and a precise and reliable quantification. This methodology has made it possible to contrast the validity of the indicators or to reconsider the specification. Conclusions. The last 10 years’ experience of the Catalonian Health Institute Working Group on Quality Indicators in designing indicators and establishing quality specifications has proved very useful for improving the monitoring of processes in clinical laboratories included in the group (AU)


Introducción. La selección y definición de los indicadores de la calidad es imprescindible para controlar adecuadamente un proceso. Ello no siempre es fácil, sobre todo en el caso de los indicadores extraanalíticos, dada la complejidad y grado de comparabilidad de los procesos entre laboratorios y la necesaria recogida de datos que en muchas ocasiones no está automatizada. Asimismo, los indicadores y especificaciones deben ser dinámicos y rediseñarse en función de los cambios del sistema. El objetivo de este trabajo es describir la metodología utilizada en la selección y definición de indicadores de calidad y especificaciones para los procesos extraanalíticos en los laboratorios públicos de Cataluña. Material y métodos. Durante el período de estudio (2004-2013), los miembros del grupo han informado del valor medio anual para cada indicador, y se ha calculado la media anual de todos los participantes para cada uno de ellos. Estos resultados se han comparado y analizado a través de reuniones periódicas, con respecto a las especificaciones preestablecidas de los diferentes laboratorios. Resultados. Se presentan los indicadores de calidad y sus especificaciones. La evaluación de la validez de cada indicador de calidad se llevó a cabo teniendo en cuenta los aspectos incluyendo la utilidad del indicador en la supervisión de procesos, una definición clara y una cuantificación precisa y fiable. Esta metodología ha permitido contrastar la validez de los indicadores o reconsiderar la especificación. Conclusiones. Los últimos 10 años de experiencia del Grupo de Trabajo del Instituto Catalán de la Salud de Indicadores de Calidad en el diseño de indicadores y en establecer especificaciones de calidad ha demostrado ser muy útil para mejorar el seguimiento de los procesos en los laboratorios clínicos integrados en el grupo (AU)


Subject(s)
Humans , Male , Female , Medical Laboratory Science/methods , Clinical Laboratory Techniques/methods , Laboratory Test/methods , Quality Indicators, Health Care/organization & administration , Quality Indicators, Health Care/standards , Quality Indicators, Health Care , Quality Assurance, Health Care/organization & administration , Quality Assurance, Health Care/standards , Quality Control , Quality of Health Care/organization & administration , Quality of Health Care/standards
2.
Med. clín (Ed. impr.) ; 116(1): 6-11, ene. 2001.
Article in Es | IBECS | ID: ibc-2900

ABSTRACT

FUNDAMENTO: Se estudió la utilidad del IGF-I, la IGFBP-3 y la excreción urinaria de la hormona del crecimiento (GH) en el diagnóstico del retraso de crecimiento en niños y adolescentes varones con talla baja. SUJETOS Y MÉTODO: Se enviaron a un laboratorio central las muestras de suero de dos pruebas farmacológicas de estímulo de la secreción de GH y dos muestras de orina de 24 h para determinar la GH sérica y urinaria, y las concentraciones séricas de IGF-I, IGFBP-3 y GHBP tanto en valores absolutos como estandarizados para sujetos de la misma edad y sexo (índice Z). Los niños con talla baja se clasificaron en dos grupos diagnósticos dependiendo de los resultados del pico de concentración de GH estimulada que se estableció arbitrariamente en 7,5 µg/l: deficitarios en hormona del crecimiento (DGH) (n = 25) (pico < 7,5 µg/l), y talla baja idiopática (TBI) (n = 54) (pico 7,5 µg/l). Además, se incluyó un grupo de 15 niños y adolescentes varones con crecimiento normal. RESULTADOS: La velocidad de crecimiento estandarizada fue menor, y el índice de masa corporal mayor, en el grupo de DGH respecto al de TBI. Los valores estandarizados del IGF-I presentaron diferencias significativas entre los 3 grupos (p = 0,001). El análisis de regresión lineal múltiple, considerando la velocidad de crecimiento estandarizada como variable dependiente, reveló que el IGF-I estandarizado es el mejor factor de predicción, seguido de la respuesta máxima de la GH al estímulo con clonidina y de la excreción urinaria de GH. Las curvas ROC revelaron un nivel de corte óptimo para el diagnóstico de déficit de GH (DGH) de -2,05 para el IGF-I estandarizado (32 por ciento de sensibilidad y 90 por ciento de especificidad) y de -1,14 para la IGFBP-3 estandarizada (28 por ciento de sensibilidad y 94 por ciento de especificidad). CONCLUSIONES: Las mediciones de IGF-I e IGFBP-3 estandarizadas para sujetos de la misma edad y sexo resultaron muy eficientes sólo en el diagnóstico del DGH grave, pero tuvieron escasa sensibilidad para diagnosticar el DGH idiopático aislado, definido según una baja respuesta de la GH a las pruebas de estímulo (AU)


Subject(s)
Child , Child, Preschool , Adolescent , Male , Humans , Sensitivity and Specificity , Growth Hormone , Regression Analysis , Insulin-Like Growth Factor I , Growth Disorders , Insulin-Like Growth Factor Binding Protein 3
SELECTION OF CITATIONS
SEARCH DETAIL