BMC Musculoskelet Disord ; 23(1): 463, 2022 May 17.
Article in English | MEDLINE | ID: mdl-35581630

ABSTRACT

INTRODUCTION: Malalignment of the Total Ankle Replacement (TAR) has often been postulated as the main reason for the high incidence of TAR failure. As the ankle joint has a small contact area, stresses are typically high, and malalignment may lead to non-homogeneous stress distributions, including stress peaks that may initiate failure. This study aims to elucidate the effect of TAR malalignment on the contact stresses on the bone-implant interface, thereby gaining more understanding of the potential role of malalignment in TAR failure. METHODS: Finite Element (FE) models of the neutrally aligned as well as malaligned CCI (Ceramic Coated Implant) Evolution TAR implant (Van Straten Medical) were developed. The CCI components were virtually inserted in a generic three-dimensional (3D) reconstruction of the tibia and talus. The tibial and talar TAR components were placed in neutral alignment and in 5° and 10° varus, valgus, anterior and posterior malalignment. Loading conditions of the terminal stance phase of the gait cycle were applied. Peak contact pressure and shear stress at the bone-implant interface were simulated and stress distributions on the bone-implant interface were visualized. RESULTS: In the neutral position, a peak contact pressure and shear stress of respectively 98.4 MPa and 31.9 MPa were found on the tibial bone-implant interface. For the talar bone-implant interface, this was respectively 68.2 MPa and 39.0 MPa. TAR malalignment increases peak contact pressure and shear stress on the bone-implant interface. The highest peak contact pressure of 177 MPa was found for the 10° valgus malaligned tibial component, and the highest shear stress of 98.5 MPa was found for the 10° posterior malaligned talar model. High contact stresses were mainly located at the edges of the bone-implant interface and the fixation pegs of the talar component. CONCLUSIONS: The current study demonstrates that TAR malalignment leads to increased peak stresses. High peak stresses could contribute to bone damage and subsequently reduced implant fixation, micromotion, and loosening. Further research is needed to investigate the relationship between increased contact stresses at the bone-implant interface and TAR failure.


Subject(s)
Arthroplasty, Replacement, Ankle , Ankle Joint/surgery , Arthroplasty, Replacement, Ankle/adverse effects , Arthroplasty, Replacement, Ankle/methods , Biomechanical Phenomena , Bone-Implant Interface , Finite Element Analysis , Humans , Stress, Mechanical , Tibia/surgery
2.
Global Spine J ; 12(7): 1330-1337, 2022 Sep.
Article in English | MEDLINE | ID: mdl-33406899

ABSTRACT

STUDY DESIGN: Preclinical ovine model. OBJECTIVE: To assess the in vivo efficacy and safety of the P-15 L bone graft substitute and compare its performance to autologous iliac crest bone graft (ICBG) for lumbar interbody fusion indications. METHODS: Thirty skeletally mature sheep underwent lumbar interbody fusion surgery. Half of the sheep received autologous ICBG and the other half the peptide enhanced bone graft substitute (P-15 L). Following termination at 1, 3, and 6 months after surgery, the operated segments were analyzed using micro computed tomography (µCT), histology, and destructive mechanical testing. Additional systemic health monitoring was performed for the P-15 L group. RESULTS: One month after surgery, there was only minor evidence of bone remodeling and residual graft material could be clearly observed within the cage. There was active bone remodeling between 1 and 3 months after surgery. At 3 months after surgery significantly denser and stiffer bone was found in the P-15 L group, whereas at 6 months, P-15 L and ICBG gave similar fusion results. The P-15 L bone graft substitute did not have any adverse effects on systemic health. CONCLUSIONS: The drug device combination P-15 L was demonstrated to be effective and save for lumbar interbody fusion as evidenced by this ovine model. Compared to autologous ICBG, P-15 L seems to expedite bone formation and remodeling but in the longer-term fusion results were similar.

3.
J Bone Miner Metab ; 40(2): 220-228, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34755216

ABSTRACT

INTRODUCTION: Although computed tomography (CT) can identify the presence of eventual bony bridges following lumbar interbody fusion (LIF) surgery, it does not provide information on the ongoing formation process of new bony structures. 18F sodium fluoride (18F-NaF) positron emission tomography (PET) could be used as complementary modality to add information on the bone metabolism at the fusion site. However, it remains unknown how bone metabolism in the operated segment changes early after surgery in uncompromised situations. This study aimed to quantify the changes in local bone metabolism during consolidation of LIF. MATERIALS AND METHODS: Six skeletally mature sheep underwent LIF surgery. 18F-NaF PET/CT scanning was performed 6 and 12 weeks postoperatively to quantify the bone volume and metabolism in the operated segment. Bone metabolism was expressed as a function of bone volume. RESULTS: Early in the fusion process, bone metabolism was increased at the endplates of the operated vertebrae. In a next phase, bone metabolism increased in the center of the interbody region, peaked, and declined to an equilibrium state. During the entire postoperative time period of 12 weeks, bone metabolism in the interbody region was higher than that of a reference site in the spinal column. CONCLUSION: Following LIF surgery, there is a rapid increase in bone metabolism at the vertebral endplates that develops towards the center of the interbody region. Knowing the local bone metabolism during uncompromised consolidation of spinal interbody fusion might enable identification of impaired bone formation early after LIF surgery using 18F-NaF PET/CT scanning.


Subject(s)
Lumbar Vertebrae , Spinal Fusion , Animals , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Osteogenesis , Positron Emission Tomography Computed Tomography , Sheep , Tomography, X-Ray Computed
4.
Spine J ; 22(1): 174-182, 2022 01.
Article in English | MEDLINE | ID: mdl-34274502

ABSTRACT

BACKGROUND CONTEXT: Lumbar interbody fusion is an effective treatment for unstable spinal segments. However, the time needed to establish a solid bony interbody fusion between the two vertebrae may be longer than twelve months after surgery. During this time window, the instrumented spinal segment is assumed to be at increased risk for instability related complications such as cage migration or subsidence. It is hypothesized that the design of new interbody cages that enable direct osseointegration of the cage at the vertebral endplates, without requiring full bony fusion between the two vertebral endplates, might shorten the time window that the instrumented spinal segment is susceptible to failure. PURPOSE: To quantify the bone ingrowth and resulting segmental stability during consolidation of lumbar interbody fusion using two different cage types. STUDY DESIGN: Preclinical ovine model. METHODS: Seven skeletally mature sheep underwent bi-segmental lumbar interbody fusion surgery with one conventional polyether ether ketone (PEEK) cage, and one newly developed trussed titanium (TT) cage. After a postoperative time period of 13 weeks, non-destructive range of motion testing, and histologic analysis was performed. Additionally, sample specific finite element (FE) analysis was performed to predict the stability of the interbody fusion region alone. RESULTS: Physiological movement of complete spinal motion segments did not reveal significant differences between the segments operated with PEEK and TT cages. The onset of creeping substitution within the cage seemed to be sooner for PEEK cages, which led to significantly higher bone volume over total volume (BV/TV) compared with the TT cages. TT cages showed significantly more direct bone to implant contact (BIC). Although the mean stability of the interbody fusion region alone was not statistically different between the PEEK and TT cages, the variation within the cage types illustrated an all-or-nothing response for the PEEK cages while a more gradual increase in stability was found for the TT cages. CONCLUSIONS: Spinal segments operated with conventional PEEK cages were not different from those operated with newly developed TT cages in terms of segmental stability but did show a different mechanism of bone ingrowth and attachment. Based on the differences in development of bony fusion, we hypothesize that TT cages might facilitate increased early segmental stability by direct osseointegration of the cage at the vertebral endplates without requiring complete bony bridging through the cage. CLINICAL SIGNIFICANCE: Interbody cage type affects the consolidation process of spinal interbody fusion. Whether different consolidation processes of spinal interbody fusion result in clinically significant differences requires further investigation.


Subject(s)
Spinal Fusion , Titanium , Animals , Benzophenones , Ethers , Ketones , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Polymers , Sheep
5.
Front Bioeng Biotechnol ; 9: 750246, 2021.
Article in English | MEDLINE | ID: mdl-35087797

ABSTRACT

Introduction: 3D printed trussed titanium interbody cages may deliver bone stimulating mechanobiological strains to cells attached at their surface. The exact size and distribution of these strains may depend on patient-specific factors, but the influence of these factors remains unknown. Therefore, this study aimed to determine patient-specific variations in local strain patterns on the surface of a trussed titanium interbody fusion cage. Materials and Methods: Four patients eligible for spinal fusion surgery with the same cage size were selected from a larger database. For these cases, patient-specific finite element models of the lumbar spine including the same trussed titanium cage were made. Functional dynamics of the non-operated lumbar spinal segments, as well as local cage strains and caudal endplate stresses at the operated segment, were evaluated under physiological extension/flexion movement of the lumbar spine. Results: All patient-specific models revealed physiologically realistic functional dynamics of the operated spine. In all patients, approximately 30% of the total cage surface experienced strain values relevant for preserving bone homeostasis and stimulating bone formation. Mean caudal endplate contact pressures varied up to 10 MPa. Both surface strains and endplate contact pressures varied more between loading conditions than between patients. Conclusions: This study demonstrates the applicability of patient-specific finite element models to quantify the impact of patient-specific factors such as bone density, degenerative state of the spine, and spinal curvature on interbody cage loading. In the future, the same framework might be further developed in order to establish a pipeline for interbody cage design optimizations.

6.
Spine J ; 21(3): 528-537, 2021 03.
Article in English | MEDLINE | ID: mdl-33007470

ABSTRACT

BACKGROUND CONTEXT: Manual contouring of spinal rods is often required intraoperatively for proper alignment of the rods within the pedicle screw heads. Residual misalignments are frequently reduced by using dedicated reduction devices. The forces exerted by these devices, however, are uncontrolled and may lead to excessive reaction forces. As a consequence, screw pullout might be provoked and surrounding tissue may experience unfavorable biomechanical loads. The corresponding loads and induced tissue deformations are however not well identified. Additionally, whether the forced reduction alters the biomechanical behavior of the lumbar spine during physiological movements postoperatively, remains unexplored. PURPOSE: To predict whether the reduction of misaligned posterior instrumentation might result in clinical complications directly after reduction and during a subsequent physiological flexion movement. STUDY DESIGN: Finite element analysis. METHODS: A patient-specific, total lumbar (L1-S1) spine finite element model was available from previous research. The model consists of poro-elastic intervertebral discs with Pfirrmann grade-dependent material parameters, with linear elastic bone tissue with stiffness values related to the local bone density, and with the seven major ligaments per spinal motion segment described as nonlinear materials. Titanium instrumentation was implemented in this model to simulate a L4, L5, and S1 posterolateral fusion. Next, coronal and sagittal misalignments of 6 mm each were introduced between the rod and the screw head at L4. These misalignments were computationally reduced and a physiological flexion movement of 15° was prescribed. Non-instrumented and well-aligned instrumented models were used as control groups. RESULTS: Pulling forces up to 1.0 kN were required to correct the induced misalignments of 6 mm. These forces affected the posture of the total lumbar spine, as motion segments were predicted to rotate up to 3 degrees and rotations propagated proximally to and even affect the L1-2 level. The facet contact pressures in the corrected misaligned models were asymmetrical suggesting non-physiological joint loading in the misaligned models. In addition, the discs and vertebrae experienced abnormally high forces as a result of the correction procedure. These effects were more pronounced after a 15° flexion movement following forced reduction. CONCLUSIONS: The results of this study indicate that the correction of misaligned posterior instrumentation can result in high forces at the screws consistent with those reported to cause screw pullout, and may cause high-tissue strains in adjacent and downstream spinal segments. CLINICAL SIGNIFICANCE: Proper alignment of spinal posterior instrumentation may reduce clinical complications secondary to unfavorable biomechanics.


Subject(s)
Intervertebral Disc Degeneration , Pedicle Screws , Spinal Fusion , Biomechanical Phenomena , Finite Element Analysis , Humans , Intervertebral Disc Degeneration/etiology , Intervertebral Disc Degeneration/surgery , Lumbar Vertebrae/surgery , Range of Motion, Articular , Spinal Fusion/adverse effects
7.
Comput Methods Biomech Biomed Engin ; 20(5): 483-491, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27800698

ABSTRACT

Pressure ulcers are a type of local soft tissue injury due to sustained mechanical loading and remain a common issue in patient care. People with spinal cord injury (SCI) are especially at risk of pressure ulcers due to impaired mobility and sensory perception. The development of load improving support structures relies on realistic tissue load evaluation e.g. using finite element analysis (FEA). FEA requires realistic subject-specific mechanical properties and geometries. This study focuses on the effect of geometry. MRI is used for the creation of geometrically accurate models of the human buttock for three able-bodied volunteers and three volunteers with SCI. The effect of geometry on observed internal tissue deformations for each subject is studied by comparing FEA findings for equivalent loading conditions. The large variations found between subjects confirms the importance of subject-specific FEA.


Subject(s)
Finite Element Analysis , Imaging, Three-Dimensional , Soft Tissue Injuries/physiopathology , Adult , Compressive Strength , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Spinal Cord Injuries/physiopathology , Stress, Mechanical , Weight-Bearing , Young Adult