Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Radiat Isot ; 164: 109297, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32768887

ABSTRACT

PURPOSE: The present study analyzed different protocols of administration of boronophenylalanine (BPA) and sodium butyrate (NaB) to increase the BNCT efficacy for poorly differentiated thyroid cancer (PDTC). MATERIALS AND METHODS: Nude mice implanted with human PDTC cells (WRO) were distributed into four protocols: 1) BPA; 2) BPA + ip NaB; 3) BPA + oral NaB; 4) Control. Biodistribution and histologic studies were performed. LAT (BPA transporter) isoforms gene expression was assessed by RT-PCR. RESULTS: Tumor growth delay was observed in animals of the Protocol #3 (p < 0.05). NaB (Protocol #2) increased tumor boron uptake 2-h post BPA injection (p < 0.05). On the other hand, NaB upregulated the expression of all the isoforms of the LAT transporter in vitro. Histologic studies showed a significant decrease of mitotic activity and an increase of vacuoles in tumors of Protocol #3. Neutrons alone or combined with NaB caused some tumor growth delay (p < 0.05), while in the BNCT and BNCT + NaB groups, there was a halt in tumor growth in 70 and 80% of the animals, respectively. CONCLUSIONS: Intraperitoneally administration of NaB increased boron uptake while oral administration for a longer period of time induced tumor growth delay previous to BPA administration. The use of NaB via ip would optimize the irradiation results.


Subject(s)
Boron Neutron Capture Therapy/methods , Butyric Acid/therapeutic use , Histone Deacetylase Inhibitors/therapeutic use , Thyroid Neoplasms/drug therapy , Thyroid Neoplasms/radiotherapy , Animals , Butyric Acid/pharmacokinetics , Cell Differentiation , Cell Line, Tumor , Combined Modality Therapy , Histone Deacetylase Inhibitors/pharmacokinetics , Humans , Mice , Thyroid Neoplasms/pathology , Tissue Distribution , Xenograft Model Antitumor Assays
2.
Phys Med ; 67: 9-19, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31610302

ABSTRACT

PURPOSE: Boron Neutron Capture Therapy (BNCT) is a treatment modality that uses an external neutron beam to selectively inactive boron10-loaded tumor cells. This work presents the development and innovative use of radiobiological probability models to adequately evaluate and compare the therapeutic potential and versatility of beams presenting different neutron energy spectra. M&M: Aforementioned characteristics, collectively refer to as the performance of a beam, were defined on the basis of radiobiological probability models for the first time in BNCT. A model of uncomplicated tumor control probability (UTCP) for HN cancer was introduced. This model considers a NTCP able to predict severe mucositis and a TCP for non-uniform doses derived herein. A systematic study comprising a simplified HN cancer model is presented as a practical application of the introduced radiobiological figures of merit (FOM) for assessing and comparing the performance of different clinical beams. Applications involving treated HN cancer patients were also analyzed. RESULTS: The maximum UTCP proved suitable and sensitive to assess the performance of a beam, revealing particularities of the studied sources that the physical FOMs do not highlight. The radiobiological FOMs evaluated in patients showed to be useful tools both for retrospective analysis of the BNCT treatments, and for prospective studies of beam optimization and feasibility. CONCLUSIONS: The presented developments and applications demonstrated that it is possible to assess and compare performances of completely different beams fairly and adequately by assessing the radiobiological FOM UTCP. Thus, this figure would be a practical and essential aid to guide treatment decisions.


Subject(s)
Boron Neutron Capture Therapy/methods , Radiobiology , Head and Neck Neoplasms/radiotherapy , Humans , Probability , Radiotherapy Dosage
3.
Appl Radiat Isot ; 61(5): 835-40, 2004 Nov.
Article in English | MEDLINE | ID: mdl-15308153

ABSTRACT

Irregular fields for boron neutron capture therapy (BNCT) have been already proposed to spare normal tissue in the treatment of superficial tumors. This added dependence would require custom measurements and/or to have a secondary calculation system. As a first step, we implemented the sector-integration method for irregular field calculation in a homogeneous medium and on the central beam axis. The dosimetric responses (fast neutron and photon dose and thermal neutron flux), are calculated by sector integrating the measured responses of circular fields over the field boundary. The measurements were carried out at our BNCT facility, the RA-6 reactor (Argentina). The input data were dosimetric responses for circular fields measured at different depths in a water phantom using ionisation and activation techniques. Circular fields were formed by shielding the beam with two plates: borated polyethilene plus lead. As a test, the dosimetric responses of a 7x4 cm(2) rectangular field, were measured and compared to calculations, yielding differences less than 3% in equivalent dose at any depth indicating that the tool is suitable for redundant calculations.


Subject(s)
Boron Neutron Capture Therapy/statistics & numerical data , Radiotherapy Planning, Computer-Assisted/statistics & numerical data , Argentina , Boron Neutron Capture Therapy/instrumentation , Humans , Neoplasms/radiotherapy , Phantoms, Imaging , Relative Biological Effectiveness
SELECTION OF CITATIONS
SEARCH DETAIL