Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Crit Care Med ; 38(11): 2095-102, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20711070

ABSTRACT

OBJECTIVE: The antimetabolite drug, 5-fluorouracil, inhibits microbial growth. Coating of central venous catheters with 5-fluorouracil may reduce the risk of catheter infection. Our objective was to compare the safety and efficacy of central venous catheters externally coated with 5-fluorouracil with those coated with chlorhexidine and silver sulfadiazine. DESIGN: Prospective, single-blind, randomized, active-controlled, multicentered, noninferiority trial. SETTING: Twenty-five US medical center intensive care units. PATIENTS: A total of 960 adult patients requiring central venous catheterization for up to 28 days. INTERVENTIONS: Patients were randomized to receive a central venous catheter externally coated with either 5-fluorouracil (n = 480) or chlorhexidine and silver sulfadiazine (n = 480). MEASUREMENTS AND MAIN RESULTS: The primary antimicrobial outcome was a dichotomous measure (<15 colony-forming units or ≥ 15 colony-forming units) for catheter colonization determined by the roll plate method. Secondary antimicrobial outcomes included local site infection and catheter-related bloodstream infection. Central venous catheters coated with 5-fluorouracil were noninferior to chlorhexidine and silver sulfadiazine coated central venous catheters with respect to the incidence of catheter colonization (2.9% vs. 5.3%, respectively). Local site infection occurred in 1.4% of the 5-fluorouracil group and 0.9% of the chlorhexidine and silver sulfadiazine group. No episode of catheter-related bloodstream infection occurred in the 5-fluorouracil group, whereas two episodes were noted in the chlorhexidine and silver sulfadiazine group. Only Gram-positive organisms were cultured from 5-fluorouracil catheters, whereas Gram-positive bacteria, Gram-negative bacteria, and Candida were cultured from the chlorhexidine and silver sulfadiazine central venous catheters. Adverse events were comparable between the two central venous catheter coatings. CONCLUSIONS: Our results suggest that central venous catheters externally coated with 5-fluorouracil are a safe and effective alternative to catheters externally coated with chlorhexidine and silver sulfadiazine when used in critically ill patients.


Subject(s)
Anti-Infective Agents, Local/therapeutic use , Antibiotic Prophylaxis/methods , Antimetabolites/therapeutic use , Catheter-Related Infections/prevention & control , Catheterization, Central Venous/methods , Chlorhexidine/therapeutic use , Fluorouracil/therapeutic use , Silver Sulfadiazine/therapeutic use , Antibiotic Prophylaxis/adverse effects , Antibiotic Prophylaxis/instrumentation , Catheter-Related Infections/microbiology , Catheterization, Central Venous/adverse effects , Catheters, Indwelling/adverse effects , Catheters, Indwelling/microbiology , Colony Count, Microbial , Critical Care/methods , Female , Humans , Male , Middle Aged , Prospective Studies , Single-Blind Method , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...