Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
World J Surg ; 41(7): 1743-1751, 2017 07.
Article in English | MEDLINE | ID: mdl-28275833

ABSTRACT

OBJECTIVE: Evaluate the capacity of government-run hospitals in Bangladesh to provide emergency and essential surgical, obstetric and anaesthetic services. METHODS: Cross-sectional survey of 240 Bangladeshi Government healthcare facilities using the World Health Organisation Situational Analysis Tool to Assess Emergency and Essential Surgical Care (SAT). This tool evaluates the ability of a healthcare facility to provide basic surgical, obstetric and anaesthetic care based on 108 queries that detail the infrastructure and population demographics, human resources, surgical interventions and reason for referral, and available surgical equipment and supplies. For this survey, the Bangladeshi Ministry of Health sent the SAT to sub-district, district/general and teaching hospitals throughout the country in April 2013. RESULTS: Responses were received from 240 healthcare facilities (49.5% response rate): 218 sub-district and 22 district/general hospitals. At the sub-district level, caesarean section was offered by 55% of facilities, laparotomy by 7% and open fracture repair by 8%. At the district/general hospital level, 95% offered caesarean section, 86% offered laparotomy and 77% offered open fracture treatment. Availability of anaesthesia services, general equipment and supplies reflected this trend, where district/general hospitals were better equipped than sub-district hospitals, though equipment and infrastructure shortages persist. CONCLUSION: There has been overall impressive progress by the Bangladeshi Government in providing essential surgical services. Areas for improvement remain across all key areas, including infrastructure, human resources, surgical interventions offered and available equipment. Investment in surgical services offers a cost-effective opportunity to continue to improve the health of the Bangladeshi population and move the country towards universal healthcare coverage.


Subject(s)
Anesthesiology , Emergency Medical Services , Health Facilities , Health Services Accessibility , Obstetrics , Bangladesh , Cesarean Section , Cross-Sectional Studies , Female , Government , Humans , Pregnancy
2.
Europace ; 19(5): 775-783, 2017 May 01.
Article in English | MEDLINE | ID: mdl-27247002

ABSTRACT

AIMS: Force-Time Integral (FTI) is commonly used as a marker of ablation lesion quality during pulmonary vein isolation (PVI), but does not incorporate power. Ablation Index (AI) is a novel lesion quality marker that utilizes contact force, time, and power in a weighted formula. Furthermore, only a single FTI target value has been suggested despite regional variation in left atrial wall thickness. We aimed to study AI's and FTI's relationships with PV reconnection at repeat electrophysiology study, and regional threshold values that predicted no reconnection. METHODS AND RESULTS: Forty paroxysmal atrial fibrillation patients underwent contact force-guided PVI, and the minimum and mean AI and FTI values for each segment were identified according to a 12-segment model. All patients underwent repeat electrophysiology study at 2 months, regardless of symptoms, to identify sites of PV reconnection. Late PV reconnection was seen in 53 (11%) segments in 25 (62%) patients. Reconnected segments had significantly lower minimum AI [308 (252-336) vs. 373 (323-423), P < 0.0001] and FTI [137 (92-182) vs. 228 (157-334), P < 0.0001] compared with non-reconnected segments. Minimum AI and FTI were both independently predictive, but AI had a smaller P value. Higher minimum AI and FTI values were required to avoid reconnection in anterior/roof segments than for posterior/inferior segments (P < 0.0001). No reconnection was seen where the minimum AI value was ≥370 for posterior/inferior segments and ≥480 for anterior/roof segments. CONCLUSION: The minimum AI value in a PVI segment is independently predictive of reconnection of that segment at repeat electrophysiology study. Higher AI and FTI values are required for anterior/roof segments than for posterior/inferior segments to prevent reconnection.


Subject(s)
Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Body Surface Potential Mapping/methods , Diagnosis, Computer-Assisted/methods , Heart Conduction System/surgery , Outcome Assessment, Health Care/methods , Pulmonary Veins/surgery , Atrial Fibrillation/physiopathology , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...