Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Front Pediatr ; 11: 1090332, 2023.
Article in English | MEDLINE | ID: mdl-36743886

ABSTRACT

Objectives: Pulmonary hemorrhage (PH) is one kind of critical lung diseases in newborn infants, which is the most difficult one to be diagnosed by ultrasound. This study was to investigate the specific ultrasonic signs of PH in order to better diagnose neonatal PH by using lung ultrasound (LUS). Methods: A total 168 newborn infants were enrolled in this study, which included PH, pneumonia, meconium aspiration syndrome, and newborns without lung diseases, there were 42 cases in each group. In a quiet state, infants were placed in the supine, lateral or prone position for the examination. Each lung was divided into the anterior, lateral and posterior regions, then each region of both lungs was scanned with the probe perpendicular to the ribs or parallel to the Intercostal spaces. Results: The major results showed that: (1) the common LUS manifestation of PH includes lung consolidation, air bronchograms, fluid bronchograms, pleural effusion, shred signs, pleural line abnormality and B-lines, while fibrin deposition sign is a rare sign of PH. (2) Co-existing of lung consolidation with fluid bronchograms and pleural effusion is the specific sign of PH with a sensitivity of 81.0%, specificity of 98.4% and the positive predictive value (PPV) was 94.4%. (3) Fibrin deposition sign is an uncommon specific LUS sign of PH with a sensitivity 28.6%, specificity of 100% and the PPV was 100%. (4) Nine patients (21.4%) were diagnosed with PH based on ultrasound findings before oronasal bleeding. (5) The survival rate of infants with PH was 100% in this study. Conclusion: LUS is helpful for the early diagnosis of neonatal PH and may therefore improve the prognosis. The lung consolidation with fluid bronchograms and pleural effusion as well as fibrin deposition sign are specific to diagnose PH by using LUS.

2.
J Vis Exp ; (157)2020 03 12.
Article in English | MEDLINE | ID: mdl-32225145

ABSTRACT

Pneumothorax (PTX) represents accumulation of the air in the pleural space. A large or tension pneumothorax can collapse the lung and cause hemodynamic compromise, a life-threatening disorder. Traditionally, neonatal pneumothorax diagnosis has been based on clinical images, auscultation, transillumination, and chest X-ray findings. This approach may potentially lead to a delay in both diagnosis and treatment. The use of lung US in diagnosis of PTX together with US-guided thoracentesis results in earlier and more precise management. The recommendations presented in this publication are aimed at improving the application of lung US in guiding neonatal PTX diagnosis and management.


Subject(s)
Pneumothorax/diagnostic imaging , Pneumothorax/surgery , Thoracentesis/methods , Ultrasonography/methods , Consensus , Female , Humans , Infant, Newborn , Male
3.
J Vis Exp ; (145)2019 03 06.
Article in English | MEDLINE | ID: mdl-30907892

ABSTRACT

Ultrasound is a safe bedside imaging tool that obviates the use of ionizing radiation diagnostic procedures. Due to its convenience, the lung ultrasound has received increasing attention from neonatal physicians. Nevertheless, clear reference standards and guideline limits are needed for accurate application of this diagnostic modality. This document aims to summarize expert opinions and to provide precise guidance to help facilitate the use of the lung ultrasound in the diagnosis of neonatal lung diseases.


Subject(s)
Guidelines as Topic , Infant, Newborn, Diseases/diagnostic imaging , Infant, Newborn, Diseases/diagnosis , Lung Diseases/diagnostic imaging , Lung Diseases/diagnosis , Lung/diagnostic imaging , Point-of-Care Systems , Ultrasonography , Consensus , Humans , Infant, Newborn , Internationality
4.
Am J Emerg Med ; 35(9): 1298-1302, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28404216

ABSTRACT

OBJECTIVE: To explore the reliability and accuracy of lung ultrasound for diagnosing neonatal pneumothorax. METHODS: This study was divided into two phases. (1) In the first phase, from January 2013 to June 2015, 40 patients with confirmed pneumothorax had lung ultrasound examinations performed to identify the sonographic characteristics of neonatal pneumothorax. (2) In the second phase, from July 2015 to August 2016, lung ultrasound was undertaken on 50 newborn infants with severe lung disease who were suspected of having pneumothorax, to evaluate the sonographic accuracy and reliability to diagnose pneumothorax. RESULTS: (1) The main ultrasonic manifestations of pneumothorax are as follows: ① lung sliding disappearance, which was observed in all patients (100%); ② the existence of the pleural line and the A-line, which was also observed in all patients (100%); ③ the lung point, which was found in 75% of the infants with mild-moderate pneumothorax but not found to exist in 25% of the severe pneumothorax patients; ④ the absence of B-lines in the area of the pneumothorax (100% of the pneumothorax patients); and ⑤ no lung consolidation existed in the area of the pneumothorax (100% of the pneumothorax patients). (2) The accuracy and reliability of the lung sonographic signs of lung sliding disappearance as well as the existence of the pleural line and the A-line in diagnosing pneumothorax were as follows: 100% sensitivity, 100% specificity, 100% positive predictive value, and 100% negative predictive value. When the lung point exists, the diagnosis is mild-moderate pneumothorax, whereas if no lung point exists, the diagnosis is severe pneumothorax. CONCLUSION: Lung ultrasound is accurate and reliable in diagnosing and ruling out neonatal pneumothorax and, in our study, was found to be as accurate as chest X-ray.


Subject(s)
Lung/diagnostic imaging , Pneumothorax/diagnostic imaging , Ultrasonography , Case-Control Studies , China , Female , Humans , Infant, Newborn , Male , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...