Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Chem Res Toxicol ; 36(8): 1355-1360, 2023 08 21.
Article in English | MEDLINE | ID: mdl-37439580

ABSTRACT

The presence and toxicological risks of synthetic coolants in electronic nicotine delivery systems (ENDS) have not been thoroughly studied. We identified the synthetic coolant menthone 1,2-glycerol ketal (MGK) in a menthol-flavored e-liquid at a concentration of ∼170 µg/mL. We also detected MGK in aerosols resulting from heating the e-liquid with an electronic waterpipe. MGK was initially detected in the e-liquid by two-dimensional gas chromatography-time-of-flight mass spectrometry. To avoid potential analytical artifacts that could result from heating samples in the injection port of the gas chromatograph, quantitation of MGK in the e-liquid was accomplished using a liquid chromatography-tandem mass spectrometry method. Following recent reports identifying other synthetic coolants in e-liquids, these results add knowledge about inhalation exposures from ENDS use and suggest the importance of future research to study the potential inhalation toxicity related to the use of MGK-containing e-liquids in ENDS devices. Furthermore, the results demonstrate the ability to quantify ketals in e-liquids using liquid chromatography methods.


Subject(s)
Electronic Nicotine Delivery Systems , Water Pipe Smoking , Nicotine/analysis , Menthol/analysis , Glycerol/analysis , Gas Chromatography-Mass Spectrometry , Aerosols/analysis , Flavoring Agents/analysis
3.
Inhal Toxicol ; 32(4): 177-187, 2020 03.
Article in English | MEDLINE | ID: mdl-32408835

ABSTRACT

Background: Marijuana blunts, which are tobacco cigar wrappers filled with marijuana, are commonly smoked in the US as a means of cannabis use. The use of marijuana blunts presents toxicity concerns because the smoke contains both marijuana-related and tobacco-related chemicals. Thus, it is important to understand the chemical composition of mainstream smoke (MSS) from marijuana blunts. This study demonstrates the ability to detect and identify chemical constituents exclusively associated with blunt MSS in contrast to tobacco cigar MSS (designated as 'new exposures') through non-targeted chemical analysis.Methods: Samples collected separately from blunt MSS and tobacco cigar MSS were analyzed using two-dimensional gas chromatography-time-of-flight mass spectrometry (GC × GC-TOFMS).Results and Discussion: Two new exposures, which likely represent only a subset of all new exposures, were identified by evaluating the data from thousands of detected signals and then confirming selected compound identities in analyses using authentic chemical standards. The two confirmed new exposures, mellein and 2-phenyl-2-oxazoline, are not cannabinoids and, to the best of our knowledge, have not been previously reported in association with cannabis, tobacco, or smoke of any kind. In addition, we detected and quantified three phenols (2-, 3-, and 4-ethylphenol) in blunt MSS. Given the toxicity of phenols, quantifying the levels of other phenols could be pursued in future research on blunt MSS.Conclusion: This study shows the power and utility of GC × GC-TOFMS as a methodology for non-targeted chemical analysis to identify new chemical exposures in blunt MSS and to provide data to guide further investigations of blunt MSS.


Subject(s)
Cannabis , Nicotiana , Smoke/analysis , Gas Chromatography-Mass Spectrometry , Marijuana Smoking , Ochratoxins/analysis , Oxazoles/analysis , Phenols/analysis , Tobacco Products
4.
Aerosol Sci Technol ; 52(11): 1233-1248, 2018.
Article in English | MEDLINE | ID: mdl-32773918

ABSTRACT

A combination of a real-time high resolution aerosol differential mobility spectrometer (DMS500) and an electrical low pressure impactor (used as a traditional impactor) was applied to simultaneously collect real-time data and analyze particle size by weighing the mass of the aerosol collected on the impactor stages. Nonrefillable fixed-power as well as refillable and power adjustable e-cigarettes (e-cigs) were tested at various puffing flow rates. Two types of smoking machines were used: a smoke cycle simulator that provides instantaneous straight sample delivery to the analyzer and a Human Profile Pump that utilizes two synchronized pistons and operates by sample pull-push mode. Chemical analysis of the major components of e-liquid (propylene glycol, vegetable glycerol, water, and nicotine) was made using a proton nuclear magnetic resonance method. Limited amounts of samples collected on impactor stages were analyzed by liquid chromatography time-of-flight mass-spectrometry to find newly formed semi- or low-volatile organic compounds in e-cig aerosol and by transmission electron microscopy to check for the presence of nanoparticles in e-cig emissions. Differential mobility and inertial impaction methods showed comparable particle size results. Method of aerosol generation (type of the smoking machine) as well as puffing topography affected the e-cig particle size. Newly formed semi- or low-volatile organic compounds as well as metal nanoparticles were found in e-cig aerosol.