Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38696672

ABSTRACT

Objective: To evaluate the safety and explore the efficacy of use of ultra-rapid lispro (URLi, Lyumjev) insulin in the Tandem t:slim X2 insulin pump with Control-IQ 1.5 technology in children, teenagers, and adults living with type 1 diabetes (T1D). Methods: At 14 U.S. diabetes centers, youth and adults with T1D completed a 16-day lead-in period using lispro in a t:slim X2 insulin pump with Control-IQ 1.5 technology, followed by a 13-week period in which URLi insulin was used in the pump. Results: The trial included 179 individuals with T1D (age 6-75 years). With URLi, 1.7% (3 participants) had a severe hypoglycemia event over 13 weeks attributed to override boluses or a missed meal. No diabetic ketoacidosis events occurred. Two participants stopped URLi use because of infusion-site discomfort, and one stopped after developing a rash. Mean time 70-180 mg/dL increased from 65% ± 15% with lispro to 67% ± 13% with URLi (P = 0.004). Mean insulin treatment satisfaction questionnaire score improved from 75 ± 13 at screening to 80 ± 11 after 13 weeks of URLi use (mean difference = 6; 95% confidence interval 4-8; P < 0.001), with the greatest improvement reported for confidence avoiding symptoms of high blood sugar. Mean treatment-related impact measure-diabetes score improved from 74 ± 12 to 80 ± 12 (P < 0.001), and mean TRIM-Diabetes Device (score improved from 82 ± 11 to 86 ± 12 (P < 0.001). Conclusions: URLi use in the Tandem t:slim X2 insulin pump with Control-IQ 1.5 technology was safe for adult and pediatric participants with T1D, with quality-of-life benefits of URLi use perceived by the study participants. Clinicaltrials.gov registration: NCT05403502.

2.
Diabetes Res Clin Pract ; 208: 111114, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38278493

ABSTRACT

OBJECTIVE: Examine patient-reported outcomes (PROs) after the use of t:slim X2 insulin pump with Control-IQ technology (CIQ) in young children with type 1 diabetes. METHODS: Children with type 1 diabetes, ages 2 to < 6 years (n = 102), were randomly assigned 2:1 to either CIQ or standard care (SC) with pump or multiple daily injections (MDI) plus continuous glucose monitoring (CGM) for 13 weeks. Both groups were offered to use CIQ for an additional 13 weeks after the randomized control trial's (RCT) completion. Guardians completed PRO questionnaires at baseline, 13-, and 26-weeks examining hypoglycemia concerns, quality of life, parenting stress, and sleep. At 26 weeks, 28 families participated in user-experience interviews. Repeated measures analyses compared PRO scores between systems used. RESULT: Comparing CIQ vs SC, responses on all 5 PRO surveys favored the CIQ group, showing that CIQ was superior to SC at 26 weeks (p values < 0.05). User-experience interviews indicated significant benefits in optimized glycemic control overall and nighttime control (28 of 28 families endorsed). All but 2/28 families noted substantial reduction in management burden resulting in less mental burden and all but 4 stated that they wanted their children to continue using CIQ. CONCLUSIONS: Families utilizing CIQ experienced glycemic benefits coupled with substantial benefits in PROs, documented in surveys and interviews. Families utilizing CIQ had reduced hypoglycemia concerns and parenting stress, and improved quality of life and sleep. These findings demonstrate the benefit of CIQ in young children with type 1 diabetes that goes beyond documented glycemic benefit.


Subject(s)
Diabetes Mellitus, Type 1 , Hypoglycemia , Child, Preschool , Humans , Blood Glucose , Blood Glucose Self-Monitoring/methods , Diabetes Mellitus, Type 1/drug therapy , Hypoglycemia/prevention & control , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use , Insulin Infusion Systems , Patient Reported Outcome Measures
3.
Clin Diabetes ; 42(1): 116-124, 2024.
Article in English | MEDLINE | ID: mdl-38230336

ABSTRACT

The t:slim X2 insulin pump with Control-IQ technology (Control-IQ) advanced hybrid closed-loop automated insulin delivery system was evaluated in this prospective single-arm trial. Thirty adults with type 2 diabetes using the Control-IQ system showed substantial glycemic improvement with no increase in hypoglycemia. Mean time in range (70-180 mg/dL) improved 15%, representing an increase of 3.6 hours/day, and mean glucose decreased by 22 mg/dL.

SELECTION OF CITATIONS
SEARCH DETAIL