Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Biomed Phys Eng Express ; 10(4)2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38815565

ABSTRACT

X-ray phase-contrast imaging has become a valuable tool for biomedical research due to its improved contrast abilities over regular attenuation-based imaging. The recently emerged Talbot-Lau interferometer can provide quantitative attenuation, phase-contrast and dark-field image data, even with low-brilliance x-ray tube sources. Thus, it has become a valid option for clinical environments. In this study, we analyze the effects of x-ray tube voltage and total number of images on the contrast-to-noise ratio (CNR) and dose-weighted CNR (CNRD) calculated from tomographic transmission and phase-contrast data of a phantom sample. Constant counting statistics regardless of the voltage was ensured by adjusting the image exposure time for each voltage setting. The results indicate that the x-ray tube voltage has a clear effect on both image contrast and noise. This effect is amplified in the case of phase-contrast images, which is explained by the polychromatic x-ray spectrum and the dependence of interferometer visibility on the spectrum. CNRD is additionally affected by the total imaging time. While submerging the sample into a water container effectively reduces image artefacts and improves the CNR, the additional attenuation of the water must be compensated with a longer exposure time. This reduces dose efficiency. Both the CNR and CNRD are higher in the phase-contrast images compared to transmission images. For transmission images, and phase-contrast images without the water container, CNRD can be increased by using higher tube voltages (in combination with a lower exposure time). For phase-contrast images with the water container, CNRD is increased with lower tube voltages. In general, the CNRD does not strongly depend on the number of tomographic angles or phase steps used.


Subject(s)
Interferometry , Phantoms, Imaging , Radiation Dosage , Interferometry/methods , Interferometry/instrumentation , Signal-To-Noise Ratio , Tomography, X-Ray Computed/methods , Humans , X-Rays , Image Processing, Computer-Assisted/methods , Algorithms
2.
ACS Appl Bio Mater ; 4(9): 7157-7167, 2021 09 20.
Article in English | MEDLINE | ID: mdl-35006947

ABSTRACT

The diversity and safety of nanofibrillated cellulose (NFC) hydrogels have gained a vast amount of interest at the pharmaceutical site in recent years. Moreover, this biomaterial has a high potential to be utilized as a protective matrix during the freeze-drying of heat-sensitive pharmaceuticals and biologics to increase their properties for long-term storing at room temperature and transportation. Since freeze-drying and subsequent reconstitution have not been optimized for this biomaterial, we must find a wider understanding of the process itself as well as the molecular level interactions between the NFC hydrogel and the most suitable lyoprotectants. Herein we optimized the reconstitution of the freeze-dried NFC hydrogel by considering critical quality attributes required to ensure the success of the process and gained insights of the obtained experimental data by simulating the effects of the used lyoprotectants on water and NFC. We discovered the correlation between the measured characteristics and molecular dynamics simulations and obtained successful freeze-drying and subsequent reconstitution of NFC hydrogel with the presence of 300 mM of sucrose. These findings demonstrated the possibility of using the simulations together with the experimental measurements to obtain a more comprehensive way to design a successful freeze-drying process, which could be utilized in future pharmaceutical applications.


Subject(s)
Cellulose , Hydrogels , Biocompatible Materials , Freeze Drying , Water
SELECTION OF CITATIONS
SEARCH DETAIL