Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
3.
Sci Total Environ ; 812: 151426, 2022 Mar 15.
Article in English | MEDLINE | ID: mdl-34748836

ABSTRACT

Particulate matter (PM), oxides of nitrogen (NOx), carbon monoxide (CO), and total hydrocarbons (THC) in gasoline exhaust affect atmospheric quality, and hence human health. Ethanol produced from corn grain is a renewable resource with favorable anti-knock properties for gasoline blending. Refiners alter petroleum composition to produce a finished blend that meets specifications. Ethanol blending affects emissions from market fuels both directly and indirectly since aromatics are typically removed from the BOB as ethanol is added to reach a constant octane rating. Numerous studies have been conducted to assess the effect of ethanol blending on light duty vehicle emissions. However, few studies have examined market fuel blends directly and small studies yield insufficient information to be generally applicable. If blending of fuels for a study does not yield gasoline that adequately resembles the composition of a market blend, the generalizability of study results may be impacted by nonlinear blending effects. Most vehicle-based fuel effect studies employed fuel formulations that either facilitate examination of several fuel variables or blend ethanol into a baseline gasoline (splash blending). Such study results do not support direct quantification of emissions inventory effects. To examine real world blending implications on regulated emissions [PM, NOx, CO, THC], we compiled a comprehensive database of US emission studies, developed regression models based on fuel and vehicle properties, and used those models to estimate differences in emissions from expected market fuel compositions. We addressed nonlinear responses to ethanol composition by modeling both low (up to 10% ethanol by volume) and mid blends (split models). We used the Federal Test Procedure (FTP) and Unified Cycle (LA92) driving schedule data, with the cold-start eliciting the highest emissions. PM cold-start emissions were lower with higher ethanol content, and more so at higher blend levels but hot-running emissions showed no differences with respect to ethanol level. For all emissions, the effects differed between port fuel injection (PFI) and gasoline direct injection (GDI) powered vehicles and for NOx, CO and THC there were differences between comphrehensive and split models. NOx results varied over blend levels and THC results were scattered for the higher blends. CO emissions were lower with higher ethanol content in nearly all cases for PFI but only the hot-running GDI. Results did not differ between summer regular and premium fuels. To the extent that PFI and GDI models differ, an emissions inventory calculation should treat them separately. There is uncertainty directly associated with the regression process, and with model inputs since study methods vary and compositions are reported differently between laboratories and test methods. Small changes in modeled emissions should be considered in this light.


Subject(s)
Air Pollutants , Air Pollutants/analysis , Ethanol/analysis , Gasoline/analysis , Humans , Particulate Matter/analysis , Vehicle Emissions/analysis
4.
Environ Health Insights ; 11: 1178630217746997, 2017.
Article in English | MEDLINE | ID: mdl-29270018

ABSTRACT

Numerous contemporary incidents demonstrate that conventional control strategies for municipal tap water have limited ability to mitigate exposures to chemicals whose sources are within distribution systems, such as lead, and chemicals that are not removed by standard treatment technologies, such as perfluorooctanoic acid (PFOA)/perfluorooctanesulfonic acid (PFOS). In these situations, point-of-use (POU) controls may be effective in mitigating exposures and managing health risks of chemicals in drinking water, but their potential utility has not been extensively examined. As an initial effort to fill this information gap, we conducted a critical review and analysis of the existing literature and data on the effectiveness of POU drinking water treatment technologies for reducing chemical contaminants commonly found in tap water in the United States. We found that many types of water treatment devices available to consumers in the United States have undergone laboratory testing and often certification for removal of chemical contaminants in tap water, but in most cases their efficacy in actual use has yet to be well characterized. In addition, the few studies of POU devices while "in use" focus on traditional contaminants regulated under the Safe Drinking Water Act, but do not generally consider nontraditional contaminants of concern, such as certain novel human carcinogens, industrial chemicals, pesticides, pharmaceuticals, personal care products, and flame retardants. Nevertheless, the limited information available at present suggests that POU devices can be highly effective when used prophylactically and when deployed in response to contamination incidents. Based on these findings, we identify future areas of research for assessing the ability of POU filters to reduce health-related chemical contaminants distributed through public water systems and private wells.

5.
J Air Waste Manag Assoc ; 66(11): 1061-1076, 2016 11.
Article in English | MEDLINE | ID: mdl-27149166

ABSTRACT

Petroleum coke or "petcoke" is a solid material created during petroleum refinement and is distributed via transfer facilities that may be located in densely populated areas. The health impacts from petcoke exposure to residents living in proximity to such facilities were evaluated for a petcoke transfer facilities located in Chicago, Illinois. Site-specific, margin of safety (MOS) and margin of exposure (MOE) analyses were conducted using estimated airborne and dermal exposures. The exposure assessment was based on a combined measurement and modeling program that included multiyear on-site air monitoring, air dispersion modeling, and analyses of soil and surfaces in residential areas adjacent to two petcoke transfer facilities located in industrial areas. Airborne particulate matter less than 10 microns (PM10) were used as a marker for petcoke. Based on daily fence line monitoring, the average daily PM10 concentration at the KCBX Terminals measured on-site was 32 µg/m3, with 89% of 24-hr average PM10 concentrations below 50 µg/m3 and 99% below 100 µg/m3. A dispersion model estimated that the emission sources at the KCBX Terminals produced peak PM10 levels attributed to the petcoke facility at the most highly impacted residence of 11 µg/m3 on an annual average basis and 54 µg/m3 on 24-hr average basis. Chemical indicators of petcoke in soil and surface samples collected from residential neighborhoods adjacent to the facilities were equivalent to levels in corresponding samples collected at reference locations elsewhere in Chicago, a finding that is consistent with limited potential for off-site exposure indicated by the fence line monitoring and air dispersion modeling. The MOE based upon dispersion model estimates ranged from 800 to 900 for potential inhalation, the primary route of concern for particulate matter. This indicates a low likelihood of adverse health effects in the surrounding community. Implications: Handling of petroleum coke at bulk material transfer facilities has been identified as a concern for the public health of surrounding populations. The current assessment, based on measurements and modeling of two facilities located in a densely populated urban area, indicates that petcoke transport and accumulation in off-site locations is minimal. In addition, estimated human exposures, if any, are well below levels that could be anticipated to produce adverse health effects in the general population.


Subject(s)
Air Pollutants/toxicity , Coke/toxicity , Environmental Exposure , Particulate Matter/toxicity , Petroleum/toxicity , Waste Disposal Facilities , Air Pollution/adverse effects , Chicago , Environmental Monitoring , Humans , Illinois , Risk Assessment
6.
Environ Sci Pollut Res Int ; 23(3): 1986-97, 2016 Feb.
Article in English | MEDLINE | ID: mdl-25994266

ABSTRACT

Growing awareness of polychlorinated biphenyls (PCBs) in legacy caulk and other construction materials of schools has created a need for information on best practices to control human exposures and comply with applicable regulations. A concise review of approaches and techniques for management of building-related PCBs is the focus of this paper. Engineering and administrative controls that block pathways of PCB transport, dilute concentrations of PCBs in indoor air or other exposure media, or establish uses of building space that mitigate exposure can be effective initial responses to identification of PCBs in a building. Mitigation measures also provide time for school officials to plan a longer-term remediation strategy and to secure the necessary resources. These longer-term strategies typically involve removal of caulk or other primary sources of PCBs as well as nearby masonry or other materials contaminated with PCBs by the primary sources. The costs of managing PCB-containing building materials from assessment through ultimate disposal can be substantial. Optimizing the efficacy and cost-effectiveness of remediation programs requires aligning a thorough understanding of sources and exposure pathways with the most appropriate mitigation and abatement methods.


Subject(s)
Air Pollution, Indoor/analysis , Air Pollution, Indoor/prevention & control , Construction Materials/analysis , Polychlorinated Biphenyls/chemistry , Schools , Environmental Exposure , Humans , Polychlorinated Biphenyls/toxicity
8.
J Asthma ; 51(6): 585-94, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24555523

ABSTRACT

OBJECTIVE: Many interventions to reduce allergen levels in the home are recommended to asthma and allergy patients. One that is readily available and can be highly effective is the use of high performing filters in forced air ventilation systems. METHODS: We conducted a modeling analysis of the effectiveness of filter-based interventions in the home to reduce airborne asthma and allergy triggers. This work used "each pass removal efficiency" applied to health-relevant size fractions of particles to assess filter performance. We assessed effectiveness for key allergy and asthma triggers based on applicable particle sizes for cat allergen, indoor and outdoor sources of particles <2.5 µm in diameter (PM2.5), and airborne influenza and rhinovirus. RESULTS: Our analysis finds that higher performing filters can have significant impacts on indoor particle pollutant levels. Filters with removal efficiencies of >70% for cat dander particles, fine particulate matter (PM2.5) and respiratory virus can lower concentrations of those asthma triggers and allergens in indoor air of the home by >50%. Very high removal efficiency filters, such as those rated a 16 on the nationally recognized Minimum Efficiency Removal Value (MERV) rating system, tend to be only marginally more effective than MERV12 or 13 rated filters. CONCLUSIONS: The results of this analysis indicate that use of a MERV12 or higher performing air filter in home ventilation systems can effectively reduce indoor levels of these common asthma and allergy triggers. These reductions in airborne allergens in turn may help reduce allergy and asthma symptoms, especially if employed in conjunction with other environmental management measures recommended for allergy and asthma patients.


Subject(s)
Air Filters , Air Pollution, Indoor/prevention & control , Allergens/analysis , Asthma/prevention & control , Environmental Exposure/prevention & control , Ventilation , Air Pollution, Indoor/analysis , Animals , Cats , Environmental Exposure/analysis , Environmental Monitoring , Humans , Particulate Matter/analysis , Viruses
9.
J Expo Sci Environ Epidemiol ; 24(3): 253-9, 2014.
Article in English | MEDLINE | ID: mdl-24496217

ABSTRACT

Long-term exposure to traffic pollution has been associated with adverse health outcomes in children and adolescents. A significant number of schools may be located near major roadways, potentially exposing millions of children to high levels of traffic pollution, but this hypothesis has not been evaluated nationally. We obtained data on the location and characteristics of 114,644 US public and private schools, grades prekindergarten through 12, and calculated their distance to the nearest major roadway. In 2005-2006, 3.2 million students (6.2%) attended 8,424 schools (7.3%) located within 100 m of a major roadway, and an additional 3.2 million (6.3%) students attended 8,555 (7.5%) schools located 100-250 m from a major roadway. Schools serving predominantly Black students were 18% (95% CI, 13-23%) more likely to be located within 250 m of a major roadway. Public schools eligible for Title I programs and those with a majority of students eligible for free/reduced price meals were also more likely to be near major roadways. In conclusion, 6.4 million US children attended schools within 250 m of a major roadway and were likely exposed to high levels of traffic pollution. Minority and underprivileged children were disproportionately affected, although some results varied regionally.


Subject(s)
Environmental Exposure , Schools , Vehicle Emissions , Humans , United States
10.
Am J Infect Control ; 40(10): 917-21, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22633439

ABSTRACT

BACKGROUND: Elevated percent positivity (≥30%) of Legionella in hospital domestic water systems has been suggested as a metric for assessing the risk of health care-acquired Legionnaires' disease (LD). METHODS: We examined the validity of this metric by analyzing data from peer-reviewed studies containing reports of Legionella prevalence in hospital water (ie, percent positivity) and temporally matched reports of patients with health care-acquired LD. RESULTS: Our literature review identified 31 peer-reviewed publications reporting matched data. We abstracted a total of 206 data points, representing 119 hospitals, from these articles. We determined that the proposed 30% positivity metric has 59% sensitivity and 74% specificity (ie, a 41% false-negative rate and a 26% false-positive rate). These notable error rates could have significant implications, given that we identified 16 peer-reviewed articles and 6 government guidance documents that referenced the 30% positivity metric as a risk assessment tool. CONCLUSIONS: Environmental sampling of hospital water distribution systems for Legionella can be an important component of risk management for LD. However, the possible consequence of using a percent positivity metric with low sensitivity and specificity is that many hospitals might fail to mitigate when a true risk is present, or might unnecessarily allocate limited resources to deal with a negligible risk.


Subject(s)
Cross Infection/epidemiology , Legionella/isolation & purification , Legionnaires' Disease/epidemiology , Risk Management/methods , Water Microbiology , Humans , Sensitivity and Specificity
11.
Environ Health ; 11: 24, 2012 Apr 10.
Article in English | MEDLINE | ID: mdl-22490055

ABSTRACT

BACKGROUND: Sealants and other building materials sold in the U.S. from 1958 - 1971 were commonly manufactured with polychlorinated biphenyls (PCBs) at percent quantities by weight. Volatilization of PCBs from construction materials has been reported to produce PCB levels in indoor air that exceed health protective guideline values. The discovery of PCBs in indoor air of schools can produce numerous complications including disruption of normal operations and potential risks to health. Understanding the dynamics of building-related PCBs in indoor air is needed to identify effective strategies for managing potential exposures and risks. This paper reports on the efficacy of selected engineering controls implemented to mitigate concentrations of PCBs in indoor air. METHODS: Three interventions (ventilation, contact encapsulation, and physical barriers) were evaluated in an elementary school with PCB-containing caulk and elevated PCB concentrations in indoor air. Fluorescent light ballasts did not contain PCBs. Following implementation of the final intervention, measurements obtained over 14 months were used to assess the efficacy of the mitigation methods over time as well as temporal variability of PCBs in indoor air. RESULTS: Controlling for air exchange rates and temperature, the interventions produced statistically significant (p < 0.05) reductions in concentrations of PCBs in indoor air of the school. The mitigation measures remained effective over the course of the entire follow-up period. After all interventions were implemented, PCB levels in indoor air were associated with indoor temperature. In a "broken-stick" regression model with a node at 20 °C, temperature explained 79% of the variability of indoor PCB concentrations over time (p < 0.001). CONCLUSIONS: Increasing outdoor air ventilation, encapsulating caulk, and constructing a physical barrier over the encapsulated material were shown to be effective at reducing exposure concentrations of PCBs in indoor air of a school and also preventing direct contact with PCB caulk. In-place management methods such as these avoid the disruption and higher costs of demolition, disposal and reconstruction required when PCB-containing building materials are removed from a school. Because of the influence of temperature on indoor air PCB levels, risk assessment results based on short-term measurements, e.g., a single day or season, may be erroneous and could lead to sub-optimal allocation of resources.


Subject(s)
Air Pollution, Indoor/analysis , Construction Materials/analysis , Polychlorinated Biphenyls/analysis , Schools , Temperature , Ventilation , Environmental Exposure/analysis , Environmental Pollutants/analysis , Humans , Maximum Allowable Concentration , Risk Assessment , United States , Volatilization
12.
Sci Total Environ ; 426: 113-9, 2012 Jun 01.
Article in English | MEDLINE | ID: mdl-22525559

ABSTRACT

In December 2008, the U.S. Consumer Product Safety Commission (CPSC) began receiving reports about odors, corrosion, and health concerns related to drywall originating from China. In response, a detailed environmental health and engineering evaluation was conducted of 41 complaint and 10 non-complaint homes in the Southeast U.S. Each home investigation included characterization of: 1) drywall composition; 2) indoor and outdoor air quality; 3) temperature, moisture, and building ventilation; and 4) copper and silver corrosion rates. Complaint homes had significantly higher hydrogen sulfide concentrations (mean 0.82 vs.

Subject(s)
Air Pollutants/analysis , Air Pollution, Indoor/statistics & numerical data , Construction Materials/analysis , Housing/statistics & numerical data , Hydrogen Sulfide/analysis , Construction Materials/statistics & numerical data , Corrosion , Environmental Monitoring , Humans , Southeastern United States
13.
J Occup Environ Med ; 53(10): 1110-4, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21918477

ABSTRACT

OBJECTIVE: To assess the effect of fine particulate matter (PM(2.5)) from different particle sources on tumor necrosis factor- (TNF-) α, we measured TNF production from rat alveolar macrophages (AM) and human dendritic cells (DC) exposed to PM(2.5) from different sources. METHODS: Fire-related PM(2.5) samples, rural ambient, and urban indoor and outdoor samples were collected in the Southeast United States. Tumor necrosis factor release was measured from rat AM and human DC following incubation with PM(2.5). RESULTS: Tumor necrosis factor release in AMs was greatest for fire-related PM(2.5) compared with other samples (TNF: P value = 0.005; mortality: P value = 0.005). Tumor necrosis factor releases from the DCs and AMs exposed to fire-associated PM(2.5) were strongly correlated (r = 0.87, P value < 0.0001). CONCLUSIONS: Particulate matter exposure produces TNF release consistent with pulmonary inflammation in rat AMs and human DCs, with the response in rat AMs differing by particle source.


Subject(s)
Air Pollutants/toxicity , Air Pollution, Indoor , Dendritic Cells/metabolism , Macrophages, Alveolar/metabolism , Particulate Matter/toxicity , Tumor Necrosis Factor-alpha/biosynthesis , Animals , Biomarkers/metabolism , Cells, Cultured , Cities , Female , Fires , Humans , Inflammation/metabolism , Rats , Seasons , Statistics, Nonparametric
14.
Environ Health ; 9: 55, 2010 Sep 03.
Article in English | MEDLINE | ID: mdl-20815876

ABSTRACT

BACKGROUND: Laboratory research studies indicate that aerosolized influenza viruses survive for longer periods at low relative humidity (RH) conditions. Further analysis has shown that absolute humidity (AH) may be an improved predictor of virus survival in the environment. Maintaining airborne moisture levels that reduce survival of the virus in the air and on surfaces could be another tool for managing public health risks of influenza. METHODS: A multi-zone indoor air quality model was used to evaluate the ability of portable humidifiers to control moisture content of the air and the potential related benefit of decreasing survival of influenza viruses in single-family residences. We modeled indoor AH and influenza virus concentrations during winter months (Northeast US) using the CONTAM multi-zone indoor air quality model. A two-story residential template was used under two different ventilation conditions - forced hot air and radiant heating. Humidity was evaluated on a room-specific and whole house basis. Estimates of emission rates for influenza virus were particle-size specific and derived from published studies and included emissions during both tidal breathing and coughing events. The survival of the influenza virus was determined based on the established relationship between AH and virus survival. RESULTS: The presence of a portable humidifier with an output of 0.16 kg water per hour in the bedroom resulted in an increase in median sleeping hours AH/RH levels of 11 to 19% compared to periods without a humidifier present. The associated percent decrease in influenza virus survival was 17.5 - 31.6%. Distribution of water vapor through a residence was estimated to yield 3 to 12% increases in AH/RH and 7.8-13.9% reductions in influenza virus survival. CONCLUSION: This modeling analysis demonstrates the potential benefit of portable residential humidifiers in reducing the survival of aerosolized influenza virus by controlling humidity indoors.


Subject(s)
Air Microbiology , Humidity , Influenza A virus/growth & development , Influenza, Human/transmission , Humans , Microbial Viability , Particle Size , Virus Inactivation
15.
J Expo Sci Environ Epidemiol ; 20(3): 273-80, 2010 May.
Article in English | MEDLINE | ID: mdl-19707248

ABSTRACT

Humans are continuously exposed to low levels of ionizing radiation. Known sources include radon, soil, cosmic rays, medical treatment, food, and building products such as gypsum board and concrete. Little information exists about radiation emissions and associated doses from natural stone finish materials such as granite countertops in homes. To address this knowledge gap, gross radioactivity, gamma ray activity, and dose rate were determined for slabs of granite marketed for use as countertops. Annual effective radiation doses were estimated from measured dose rates and human activity patterns while accounting for the geometry of granite countertops in a model kitchen. Gross radioactivity, gamma activity, and dose rate varied significantly among and within slabs of granite with ranges for median levels at the slab surface of ND to 3000 cpm, ND to 98,000 cpm, and ND to 1.5E-4 mSv/h, respectively. The maximum activity concentrations of the (40)K, (232)Th, and (226)Ra series were 2715, 231, and 450 Bq/kg, respectively. The estimated annual radiation dose from spending 4 h/day in a hypothetical kitchen ranged from 0.005 to 0.18 mSv/a depending on the type of granite. In summary, our results show that the types of granite characterized in this study contain varying levels of radioactive isotopes and that their observed emissions are consistent with those reported in the scientific literature. We also conclude from our analyses that these emissions are likely to be a minor source of external radiation dose when used as countertop material within the home and present a negligible risk to human health.


Subject(s)
Air Pollutants, Radioactive/analysis , Air Pollution, Indoor/analysis , Construction Materials , Environmental Exposure/analysis , Environmental Exposure/statistics & numerical data , Radon/analysis , Silicon Dioxide , Air Pollutants, Radioactive/adverse effects , Air Pollution, Indoor/adverse effects , Construction Materials/adverse effects , Environmental Exposure/adverse effects , Housing , Humans , Potassium Radioisotopes/adverse effects , Potassium Radioisotopes/analysis , Radon/adverse effects , Risk Assessment , Silicon Dioxide/adverse effects , Thorium/adverse effects , Thorium/analysis , United States
16.
J Expo Sci Environ Epidemiol ; 20(3): 263-72, 2010 May.
Article in English | MEDLINE | ID: mdl-19707250

ABSTRACT

Radon gas ((222)Rn) is a natural constituent of the environment and a risk factor for lung cancer that we are exposed to as a result of radioactive decay of radium ((226)Ra) in stone and soil. Granite countertops, in particular, have received recent media attention regarding their potential to emit radon. Radon flux was measured on 39 full slabs of granite from 27 different varieties to evaluate the potential for exposure and examine determinants of radon flux. Flux was measured at up to six pre-selected locations on each slab and also at areas identified as potentially enriched after a full-slab scan using a Geiger-Muller detector. Predicted indoor radon concentrations were estimated from the measured radon flux using the CONTAM indoor air quality model. Whole-slab average emissions ranged from less than limit of detection to 79.4 Bq/m(2)/h (median 3.9 Bq/m(2)/h), similar to the range reported in the literature for convenience samples of small granite pieces. Modeled indoor radon concentrations were less than the average outdoor radon concentration (14.8 Bq/m(3); 0.4 pCi/l) and average indoor radon concentrations (48 Bq/m(3); 1.3 pCi/l) found in the United States. Significant within-slab variability was observed for stones on the higher end of whole slab radon emissions, underscoring the limitations of drawing conclusions from discrete samples.


Subject(s)
Air Pollutants, Radioactive/analysis , Air Pollution, Indoor/analysis , Construction Materials , Environmental Exposure/analysis , Environmental Exposure/statistics & numerical data , Radon/analysis , Silicon Dioxide , Air Pollutants, Radioactive/adverse effects , Air Pollution, Indoor/adverse effects , Construction Materials/adverse effects , Environmental Exposure/adverse effects , Housing , Humans , Lung Neoplasms/epidemiology , Lung Neoplasms/etiology , Radiometry , Radon/adverse effects , Risk Assessment , Silicon Dioxide/adverse effects , Silicon Dioxide/chemistry , United States
17.
J Expo Sci Environ Epidemiol ; 20(2): 213-24, 2010 Mar.
Article in English | MEDLINE | ID: mdl-19319161

ABSTRACT

Health risks of fine particle air pollution (PM(2.5)) are an important public health concern that has the potential to be mitigated in part by interventions such as air cleaning devices that reduce personal exposure to ambient PM(2.5). To characterize exposure to ambient PM(2.5) indoors as a function of residential air cleaners, a multi-zone indoor air quality model was used to integrate spatially resolved data on housing, meteorology, and ambient PM(2.5), with performance testing of residential air cleaners to estimate short-term and annual average PM(2.5) of outdoor origin inside residences of three metropolitan areas. The associated public health impacts of reduced ambient PM(2.5) exposure were estimated using a standard health impact assessment methodology. Estimated indoor levels of ambient PM(2.5) varied substantially among ventilation and air cleaning configurations. The median 24-h average indoor-outdoor ratio of ambient PM(2.5) was 0.57 for homes with natural ventilation, 0.35 for homes with central air conditioning (AC) with conventional filtration, and 0.1 for homes with central AC with high efficiency in-duct air cleaner. Median modeled 24-h average indoor concentrations of PM(2.5) of outdoor origin for those three configurations were 8.4, 5.3, and 1.5 microg/m(3), respectively. The potential public health benefits of reduced exposure to ambient PM(2.5) afforded by air cleaning systems were substantial. If the entire population of single-family homes with central AC in the modeling domain converted from conventional filtration to high-efficiency in-duct air cleaning, the change in ambient PM(2.5) exposure is estimated to result in an annual reduction of 700 premature deaths, 940 hospital and emergency room visits, and 130,000 asthma attacks in these metropolitan areas. In addition to controlling emissions from sources, high-efficiency whole-house air cleaner are expected to reduce exposure to particles of outdoor origin and are projected to be an effective means of managing public health impacts of ambient particle pollution.


Subject(s)
Air Pollutants/isolation & purification , Environmental Exposure , Models, Theoretical , Air Pollutants/toxicity , Air Pollution, Indoor , Particle Size
18.
J Air Waste Manag Assoc ; 58(11): 1474-82, 2008 Nov.
Article in English | MEDLINE | ID: mdl-19044163

ABSTRACT

A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-microm particles ranged from 1.5 hr(-1) during operation of an in-duct, 5-in. pleated media filter to 7.2 hr(-1) for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr(-1) when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 microm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr(-1) under baseline conditions, 0.5 hr(-1) during operation of three portable ionic air cleaners, 1 hr(-1) for an in-duct 1-in. media filter, 2.4 hr(-1) for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr(-1) for an in-duct 5-in. media filter, 4.7 hr(-1) during operation of five portable HEPA filters, 6.1 hr(-1) for a conventional in-duct electronic air cleaner, and 7.5 hr(-1) for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates.


Subject(s)
Air Pollutants, Occupational/analysis , Air Pollution/analysis , Environmental Monitoring/statistics & numerical data , Meteorology/statistics & numerical data , Models, Statistical , Oxidants, Photochemical/analysis , Ozone/analysis , Thailand , Vietnam , Weather
19.
Environ Health ; 7: 43, 2008 Aug 06.
Article in English | MEDLINE | ID: mdl-18684328

ABSTRACT

BACKGROUND: Reducing exposure to environmental agents indoors shown to increase asthma symptoms or lead to asthma exacerbations is an important component of a strategy to manage asthma for individuals. Numerous investigations have demonstrated that portable air cleaning devices can reduce concentrations of asthma triggers in indoor air; however, their benefits for breathing problems have not always been reproducible. The potential exposure benefits of whole house high efficiency in-duct air cleaners for sensitive subpopulations have yet to be evaluated. METHODS: We used an indoor air quality modeling system (CONTAM) developed by NIST to examine peak and time-integrated concentrations of common asthma triggers present in indoor air over a year as a function of natural ventilation, portable air cleaners, and forced air ventilation equipped with conventional and high efficiency filtration systems. Emission rates for asthma triggers were based on experimental studies published in the scientific literature. RESULTS: Forced air systems with high efficiency filtration were found to provide the best control of asthma triggers: 30-55% lower cat allergen levels, 90-99% lower risk of respiratory infection through the inhalation route of exposure, 90-98% lower environmental tobacco smoke (ETS) levels, and 50-75% lower fungal spore levels than the other ventilation/filtration systems considered. These results indicate that the use of high efficiency in-duct air cleaners provide an effective means of controlling allergen levels not only in a single room, like a portable air cleaner, but the whole house. CONCLUSION: These findings are useful for evaluating potential benefits of high efficiency in-duct filtration systems for controlling exposure to asthma triggers indoors and for the design of trials of environmental interventions intended to evaluate their utility in practice.


Subject(s)
Air Pollution, Indoor/prevention & control , Allergens/analysis , Asthma/prevention & control , Air Conditioning , Air Pollution, Indoor/adverse effects , Air Pollution, Indoor/analysis , Allergens/immunology , Animals , Asthma/etiology , Asthma/immunology , Cats , Environmental Exposure/adverse effects , Environmental Exposure/prevention & control , Environmental Monitoring , Filtration , Humans , Orthomyxoviridae/isolation & purification , Particulate Matter/adverse effects , Particulate Matter/analysis , Rhinovirus/isolation & purification , Spores, Fungal/isolation & purification , Tobacco Smoke Pollution/adverse effects , Tobacco Smoke Pollution/analysis , Ventilation
20.
J Occup Environ Hyg ; 3(7): 379-89, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16835164

ABSTRACT

Airborne fungal spores were measured in 44 office buildings in the summer and winter throughout the continental United States, as part of the Building Assessment, Survey and Evaluation (BASE) program. Six indoor air and two outdoor air samples were collected on a single day from each building. The cross-sectional and repeated measure design afforded evaluation of between-building and within-building variability of fungal spore levels in buildings. Total fungal spore concentrations in indoor air ranged from < 24 to 1000 spores/m3, except for one building with natural ventilation where indoor levels were approximately 9000 spores/m3. Indoor air concentrations of total spores did not vary significantly between winter and summer or morning and afternoon monitoring periods or among climate zones or locations within a test area. Indoor-outdoor ratios of total spore concentrations typically ranged between 0.01 and 0.1 and were approximately seven times greater in winter than summer because of relatively low outdoor levels in the winter. The indoor-outdoor ratio of total spore concentrations for a building was consistent (reliability coefficient = 0.91) among repeated measures. Distributions of rank correlation coefficients for spore types in pairs of individual indoor-outdoor and indoor-indoor samples were weakly correlated (Spearman correlation = 0.2 on average). When spore type data were aggregated among samples from the same building, the central tendency of the rank correlation coefficients increased to 0.45. Rank correlation coefficients were also proportional to the number of spore types present in the samples that were compared. The BASE study provides normative data on concentrations of fungal spores that can aid in identification of problematic levels of mold in buildings.


Subject(s)
Air Microbiology , Air Pollutants, Occupational/analysis , Air Pollution, Indoor/analysis , Spores, Fungal/isolation & purification , Cross-Sectional Studies , Environmental Monitoring , Facility Design and Construction , Occupational Exposure , Seasons , Sick Building Syndrome , United States
SELECTION OF CITATIONS