Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35
Filter
1.
Article in English | MEDLINE | ID: mdl-39054295

ABSTRACT

BACKGROUND AND PURPOSE: Lumbar disc herniation, potentially leading to nerve root compression and cauda equina syndrome, is typically evaluated using MR imaging. However, the limited availability of MR imaging outside regular hours in certain health care systems poses considerable challenges. This purpose of this study was to prospectively evaluate the diagnostic accuracy of an optimized CT lumbar spine protocol as a potential alternative to MR imaging in assessing suspected neural compression. MATERIALS AND METHODS: Patients presenting to the emergency department with suspected cauda equina syndrome or acute radicular symptoms secondary to lumbar disc herniation referred for MR imaging were prospectively enrolled for an additional CT optimized to assess spinal stenosis. An expert radiologist, blinded to clinical data, graded canal stenosis at each lumbar level on CT. The same grading process was applied to MR imaging after a 4-week interval to maintain blinding. RESULTS: Fifty-nine individuals were included in the final analysis. In 22 (39%) cases, no significant stenosis was identified. In a further 22 (37%) cases, disc pathology was identified that was managed conservatively. Thirteen (22%) individuals proceeded to urgent surgical decompression. In 1 (2%) instance, an alternative diagnosis was identified. Compared with MR imaging, the sensitivity, specificity, and positive and negative predictive values for CT in detecting disc pathology in patients presenting with symptoms suggestive of acute neural compression were 97% (95% CI, 82%-99%), 97% (95% CI, 83%-99%), 97% (95% CI, 92%-99%), and 97% (95% CI, 83%-99%), respectively. CT accurately identified all cases requiring urgent decompression. CONCLUSIONS: CT accurately predicted MR imaging findings in patients with suspected cauda equina and nerve root compression, demonstrating its utility as an adjunct tool for patient triage in emergency settings with limited MR imaging access. This protocol could enhance the allocation of emergency resources by appropriately selecting patients for emergent MR imaging.

2.
Br J Radiol ; 97(1159): 1234-1242, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38718224

ABSTRACT

BACKGROUND: Prostate cancer ranks among the most prevalent cancers affecting men globally. While conventional MRI serves as a diagnostic tool, its extended acquisition time, associated costs, and strain on healthcare systems, underscore the necessity for more efficient methods. The emergence of AI-acceleration in prostate MRI offers promise to mitigate these challenges. METHODS: A systematic review of studies looking at AI-accelerated prostate MRI was conducted, with a focus on acquisition time along with various qualitative and quantitative measurements. RESULTS: Two primary findings were observed. Firstly, all studies indicated that AI-acceleration in MRI achieved notable reductions in acquisition times without compromising image quality. This efficiency offers potential clinical advantages, including reduced scan durations, improved scheduling, diminished patient discomfort, and economic benefits. Secondly, AI demonstrated a beneficial effect in reducing or maintaining artefact levels in T2-weighted images despite this accelerated acquisition time. Inconsistent results were found in all other domains, which were likely influenced by factors such as heterogeneity in methodologies, variability in AI models, and diverse radiologist profiles. These variances underscore the need for larger, more robust studies, standardization, and diverse training datasets for AI models. CONCLUSION: The integration of AI-acceleration in prostate MRI thus far shows some promising results for efficient and enhanced scanning. These advancements may fill current gaps in early detection and prognosis. However, careful navigation and collaborative efforts are essential to overcome challenges and maximize the potential of this innovative and evolving field. ADVANCES IN KNOWLEDGE: This article reveals overall significant reductions in acquisition time without compromised image quality in AI-accelerated prostate MRI, highlighting potential clinical and diagnostic advantages.


Subject(s)
Magnetic Resonance Imaging , Prostatic Neoplasms , Humans , Male , Prostatic Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Prostate/diagnostic imaging , Prostate/pathology , Artificial Intelligence
3.
Eur Radiol ; 34(8): 4864-4873, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38296849

ABSTRACT

BACKGROUND: Pulmonary embolism (PE) is a leading cause of pregnancy-related mortality. CT pulmonary angiogram (CTPA) is the first-line advanced imaging modality for suspected PE in pregnancy at institutes offering low-dose techniques; however, a protocol balancing safety with low dose remains undefined. The wide range of CTPA doses reported in pregnancy suggests a lack of confidence in implementing low-dose techniques in this group. PURPOSE: To define and validate the safety, radiation dose and image quality of a low-dose CTPA protocol optimised for pregnancy. MATERIALS AND METHODS: The OPTICA study is a prospective observational study. Pregnant study participants with suspected PE underwent the same CTPA protocol between May 2018 and February 2022. The primary outcome, CTPA safety, was judged by the reference standard; the 3-month incidence of venous thromboembolism (VTE) in study participants with a negative index CTPA. Secondary outcomes defined radiation dose and image quality. Absorbed breast, maternal effective and fetal doses were estimated by Monte-Carlo simulation on gestation-matched phantoms. Image quality was assessed by signal-to-noise and contrast-to-noise ratios and a Likert score for pulmonary arterial enhancement. RESULTS: A total of 116 CTPAs were performed in 113 pregnant women of which 16 CTPAs were excluded. PE was diagnosed on 1 CTPA and out-ruled in 99. The incidence of recurrent symptomatic VTE was 0.0% (one-sided 95% CI, 2.66%) at follow-up. The mean absorbed breast dose was 2.9 ± 2.1mGy, uterine/fetal dose was 0.1 ± 0.2mGy and maternal effective dose was 1.4 ± 0.9mSv. Signal-to-noise ratio (SNR) was 11.9 ± 3.7. Contrast-to-noise ratio (CNR) was 10.4 ± 3.5. CONCLUSION: The OPTICA CTPA protocol safely excluded PE in pregnant women across all trimesters, with low fetal and maternal radiation. CLINICAL RELEVANCE: OPTICA (Optimised CT Pulmonary Angiography in Pregnancy) is the first prospective study to define the achievable radiation dose, image-quality and safety of a low-dose CT pulmonary angiogram protocol optimised for pregnancy (NCT04179487). It provides the current benchmark for safe and achievable CT pulmonary angiogram doses in the pregnant population. KEY POINTS: • Despite the increased use of CT pulmonary angiogram in pregnancy, an optimised low-dose protocol has not been defined and reported doses in pregnancy continue to vary widely. • The OPTICA (Optimised CT Pulmonary Angiography in Pregnancy) study prospectively defines the achievable dose, image quality and safety of a low-dose CT pulmonary angiogram protocol using widely available technology. • OPTICA provides a benchmark for safe and achievable CT pulmonary angiogram doses in the pregnant population.


Subject(s)
Computed Tomography Angiography , Pregnancy Complications, Cardiovascular , Pulmonary Embolism , Radiation Dosage , Humans , Female , Pregnancy , Computed Tomography Angiography/methods , Adult , Prospective Studies , Pulmonary Embolism/diagnostic imaging , Pregnancy Complications, Cardiovascular/diagnostic imaging , Signal-To-Noise Ratio
4.
Br J Radiol ; 96(1146): 20220143, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37066810

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate the technical success and complication rates of image-guided lumbar puncture (IGLP) and to evaluate for differences in approach employed to help establish the optimum technique. METHODS: A retrospective search of the hospital picture archiving and communications system was performed to identify all IGLPs that had taken place over a 5-year period. Radiology reports and the electronic medical record were examined to identify technical parameters and complications associated with each procedure. RESULTS: The technical success rate was 96% (219/228). 69.4% (n = 161) had a previously failed bedside attempt. The rate of complications was 0.01% (n = 2). No major complications were observed. There was no difference in the rates of failure (2.4% vs 3.6%, p = 0.68) or complications (0.008% vs 0.012%, p = 1) between interlaminar and interspinous approaches. CONCLUSION: IGLP is a safe procedure with a high rate of technical success. Where a difficult bedside attempt is anticipated, it is reasonable to forego this and proceed directly to IGLP. ADVANCES IN KNOWLEDGE:: This paper helps to confirm what is already assumed about a common radiological procedure. This is important as there has been a shift from bedside technique to most lumbar punctures being performed via image guidance.


Subject(s)
Radiography, Interventional , Spinal Puncture , Humans , Spinal Puncture/methods , Retrospective Studies , Fluoroscopy , Radiography, Interventional/methods , Radiology, Interventional
5.
Quant Imaging Med Surg ; 13(1): 196-209, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36620175

ABSTRACT

Background: Limited magnetic resonance (MR) pulse sequences facilitate lumbosacral nerve imaging with acceptable image quality. This study aimed to evaluate the impact of parameter modification for Diffusion Weighted Image (DWI) using Readout Segmentation of Long Variable Echo-trains (RESOLVE) sequence with opportunities for improving the visibility of lumbosacral nerves and image quality. Methods: Following ethical approval and acquisition of informed consent, imaging of an MR phantom and twenty healthy volunteers (n=20) was prospectively performed with 3T MRI scanner. Acquired sequences included standard two-dimensional (2D) turbo spin echo sequences and readout-segmented echo-planar imaging (EPI) DWI-RESOLVE using three different b-values b-50, b-500 and b-800 s/mm2. Signal-to-noise ratio (SNR), apparent diffusion coefficient (ADC) and nerve size were measured. Two musculoskeletal radiologists evaluated anatomical structure visualisation and image quality. Quantitative and qualitative findings for healthy volunteers were investigated for differences using Wilcoxon signed-rank and Friedman tests, respectively. Inter and intra-observer agreement was determined with κ statistics. Results: Phantom images revealed higher SNR for images with low b-values with 206.1 (±10.9), 125.1 (±45.2) and 59.2 (±17.8) for DWI-RESOLVE images acquired at b50, b500 and b800, respectively. Comparable results were found for SNR, ADC and nerve size across normal right and left sided for healthy volunteer images. The SNR findings for b-50 images were higher than b-500 and b-800 images for healthy volunteer images. The qualitative findings ranked images acquired using b-50 and b-500 images significantly higher than corresponding b-800 images (P<0.05). Inter and intra-observer agreements for evaluation across all b-values ranged from 0.59 to 0.81 and 0.83 to 0.92, respectively. Conclusions: The modified DWI-RESOLVE images facilitated visualization of the normal lumbosacral nerves with acceptable image quality, which support the clinical applicability of this sequence.

6.
Skeletal Radiol ; 52(10): 1863-1871, 2023 Oct.
Article in English | MEDLINE | ID: mdl-36171350

ABSTRACT

Epidural steroid injections (ESIs) play an important role in the multifaceted management of neck and back pain. Corticosteroid preparations used in ESIs may be considered "particulate" or "non-particulate" based on whether they form a crystalline suspension or a soluble clear solution, respectively. In the past two decades, there have been reports of rare but severe and permanent neurological complications as a result of ESI. These complications have principally occurred with particulate corticosteroid preparations when using a transforaminal injection technique at cervical or thoracic levels, and only rarely in the lumbosacral spine. As a result, some published clinical guidelines and recommendations have advised against the use of particulate corticosteroids for transforaminal ESI, and the FDA introduced a warning label for injectable corticosteroids regarding the risk of serious neurological adverse events. There is growing evidence that the efficacy of non-particulate corticosteroids for pain relief and functional improvement after ESI is non-inferior to particulate agents, and that non-particulate injections almost never result in permanent neurological injury. Despite this, particulate corticosteroids continue to be routinely used for transforaminal epidural injections. More consistent clinical guidelines and societal recommendations are required alongside increased awareness of the comparative efficacy of non-particulate agents among specialists who perform ESIs. The current role for particulate corticosteroids in ESIs should be limited to caudal and interlaminar approaches, or transforaminal injections in the lumbar spine only if initial non-particulate ESI resulted in a significant but short-lived improvement.


Subject(s)
Adrenal Cortex Hormones , Back Pain , Humans , Adrenal Cortex Hormones/therapeutic use , Back Pain/drug therapy , Lumbosacral Region , Lumbar Vertebrae , Injections, Epidural/methods , Steroids/therapeutic use
7.
J Thorac Imaging ; 38(1): 36-43, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36162076

ABSTRACT

OBJECTIVES: To determine the impact of breast shields on breast dose and image quality when combined with a low-dose computed tomography pulmonary angiography (CTPA) protocol for pregnancy. METHODS: A low-dose CTPA protocol, with and without breast shields, was evaluated by anthropomorphic phantom and 20 prospectively recruited pregnant participants from January to October 2019. Thermoluminescent dosimeters measured surface and absorbed breast dose in the phantom and surface breast dose in participants. The Monte-Carlo method estimated the absorbed breast dose in participants. Image quality was assessed quantitatively by regions of interest analysis and subjectively by the Likert scale. Doses and image quality for CTPA alone were compared with CTPA with breast shields. RESULTS: Mean surface and absorbed breast dose for CTPA alone were 1.3±0.4 and 2.8±1.5 mGy in participants, and 1.5±0.7 and 1.6±0.6 mGy in the phantom. Shielding reduced surface breast dose to 0.5±0.3 and 0.7±0.2 mGy in the phantom (66%) and study participants (48%), respectively. Absorbed breast dose reduced to 0.9±0.5 mGy (46%) in the phantom.Noise increased with breast shields at lower kV settings (80 to 100 kV) in the phantom; however, in study participants there was no significant difference between shield and no-shield groups for main pulmonary artery noise (no-shield: 34±9.8, shield: 36.3±7.2, P =0.56), SNR (no-shield: 11.2±3.7, shield: 10.8±2.6, P =0.74) or contrast-to-noise ratio (no-shield: 10.0±3.3, shield: 9.3±2.4, P =0.6). Median subjective image quality scores were comparable (no-shield: 4.0, interquartile range: 3.5 to 4.4, shield: 4.3, interquartile range: 4.0 to 4.5). CONCLUSION: Combining low-dose CTPA with breast shields confers additional breast-dose savings without impacting image quality and yields breast doses approaching those of low-dose scintigraphy, suggesting breast shields play a role in protocol optimization for select groups.


Subject(s)
Angiography , Tomography, X-Ray Computed , Female , Pregnancy , Humans , Radiation Dosage , Tomography, X-Ray Computed/methods , Phantoms, Imaging , Computed Tomography Angiography/methods
9.
Br J Radiol ; 94(1126): 20201333, 2021 Oct 01.
Article in English | MEDLINE | ID: mdl-34328792

ABSTRACT

Currently, there is much variation in the terminology used to describe groin pain in athletes. Several groups have attempted to reach consensus on nomenclature in this area. This article outlines the current status of groin pain nomenclature for the radiologist, highlighting inherent heterogeneity, recent attempts to reach a consensus, the need for a radiological consensus and why imprecise terminology should be avoided when reporting.


Subject(s)
Athletic Injuries/diagnostic imaging , Groin/diagnostic imaging , Groin/injuries , Pelvic Pain/diagnostic imaging , Terminology as Topic , Humans
10.
Insights Imaging ; 12(1): 54, 2021 Apr 20.
Article in English | MEDLINE | ID: mdl-33877460

ABSTRACT

OBJECTIVES: To investigate the accuracy of Diffusion Weighted Imaging (DWI) using the Readout Segmentation of Long Variable Echo-trains (RESOLVE) sequence in detecting lumbosacral nerve abnormalities. METHODS: Following institutional ethics committee approval, patients with sciatica-type lower limb radicular symptoms (n = 110) were recruited and prospectively scanned using 3T MRI. Additional participants (n = 17) who underwent neurophysiological testing (EMG/NCV), were also prospectively studied. In addition to routine lumbar spine MRI, a DWI-RESOLVE sequence of the lumbosacral plexus was performed. Two radiologists, blinded to the side of patient symptoms, independently evaluated the MR images. The size and signal intensity changes of the nerves were evaluated using ordinal 4-point Likert-scales. Signal-to-noise ratio (SNR), apparent diffusion coefficient (ADC) and size were measured for affected and normal nerves. Inter-observer agreement was determined with kappa statistics; κ. RESULTS: In patients who did not undergo EMG/NCV testing (n = 110), the DWI-RESOLVE sequence detected lumbosacral nerve abnormalities that correlated with symptoms in 36.3% (40/110). This is a similar percentage to patients who underwent EMG/NCV testing, which was positive and correlated with symptoms in 41.2% (7/17). Inter-observer agreement for evaluation of lumbosacral nerve abnormalities was excellent and ranged from 0.87 to 0.94. SNR and nerve size measurements demonstrated statistically significant differences for the L5 and S1 nerves (p value < 0.05) for patients who did not undergo EMG/NCV testing. CONCLUSION: The DWI-RESOLVE sequence is a promising new method that may permit accurate detection and localization of lumbar nerve abnormalities in patients with sciatica.

11.
Acad Radiol ; 28(10): 1426-1432, 2021 10.
Article in English | MEDLINE | ID: mdl-32952034

ABSTRACT

OBJECTIVE: A radiology sign that references a resemblance to something which is not actually present within an image has been termed a 'metaphoric' sign. Metaphoric signs are widely described in the literature and commonly used in teaching as a form of pattern recognition, or 'pareidolia'. However, the educational benefit of metaphoric signs has not been previously assessed. We aimed to assess the utility of metaphoric signs in medical student teaching. MATERIALS AND METHODS: Fifteen radiology cases were prepared into two lecture formats for medical student education. A 'test' lecture utilizing metaphoric radiology signs to describe the appearance of the cases and a 'control' lecture where pathology was compared to normal anatomical appearances without reference to metaphoric signs. Forty-nine volunteer medical students were randomized with cluster sampling to receive either the test or control lecture. Four days later, students were quizzed to determine retention of knowledge and to assess interest in the lecture on a visual analogue scale from 0 to 100. RESULTS: The median interest level of the test group (69.5) was higher than the control group (50) (p = 0.001). The mean quiz score was higher in the test group (34.5) than in the control group (29) (Difference 5.5, 95% confidence interval 0.08-10.92, p = 0.047). CONCLUSION: The use of metaphoric signs in radiology education of medical students increased interest, descriptive ability and short-term knowledge retention, compared to the same material taught with normal anatomy correlation. Metaphoric signs should be considered as a useful radiology teaching tool.


Subject(s)
Education, Medical , Radiology , Students, Medical , Teacher Training , Humans
12.
Eur J Radiol ; 134: 109414, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33246271

ABSTRACT

PURPOSE: To date, the majority of chest imaging studies in COVID-19 pneumonia have focused on CT. Evidence for the utility of chest radiographs (CXRs) in this population is less robust. Our objectives were to develop a systematic approach for reporting likelihood of COVID-19 pneumonia on CXRs, to measure the interobserver variability of this approach and to evaluate the diagnostic performance of CXRs compared to real-time reverse transcription polymerase chain reaction (RT-PCR). METHOD: Retrospective review of patients suspected of having COVID-19 pneumonia who attended our emergency department and underwent both CXR and a RT-PCR were included. Two radiologists reviewed the CXRs, blind to the RT-PCR, and classified them according to a structured reporting template with five categories (Characteristic, High Suspicion, Indeterminate, Unlikely and Normal) which we devised. For analysis of diagnostic accuracy, Characteristic and High Suspicion CXRs were considered positive and the remaining categories negative. Concordance between the two assessors was also measured. RESULTS: Of 582 patients (51 +/- 20 years), 143/582 (24.6 %) had a positive RT-PCR. The absolute concordance between the two assessors was 71.1 % (414/582) with a Fleiss-Cohen-weighted Cohen's κ of 0.81 (95 % confidence interval, 0.78-0.85). A patient with a positive CXR had an 88 % (95 % CI 80-96 %) probability of having a positive RT-PCR during a period of high incidence, early in the COVID-19 pandemic. CONCLUSION: Using a structured approach, a positive CXR had a high likelihood of predicting a positive RT-PCR, with good interrater reliability. CXRs can be useful in identifying new cases of COVID-19.


Subject(s)
COVID-19/diagnosis , Lung/diagnostic imaging , Radiography, Thoracic/methods , Adult , Aged , Emergency Service, Hospital , Female , Humans , Male , Middle Aged , Observer Variation , Pandemics , Reproducibility of Results , Retrospective Studies , SARS-CoV-2 , Sensitivity and Specificity
13.
Skeletal Radiol ; 50(2): 343-349, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32734375

ABSTRACT

OBJECTIVE: To establish the incidence and define the nature of complications occurring following image-guided musculoskeletal injections at our institution. MATERIALS AND METHODS: All patients undergoing image-guided musculoskeletal injection during the study period (16/3/2016 to 24/01/2020) were included. Departmental records were reviewed to identify all patients describing possible complications following injection, what therapy was required (if any) and what the outcome was. No patients were excluded. Complications were classified as minor or major. Injections were categorised as follows: cervical spine, lumbar facet joint, lumbar nerve root, caudal epidural and 'other'. The complication rate for each individual category of procedure was compared with the combined complication rate for all other categories by constructing contingency tables and using Fisher's exact test. RESULTS: A total of 8226 patients underwent image-guided musculoskeletal injections within the study period. Exactly 100 patients were identified as having reported a complication, producing an overall complication rate of 1.2%. One complication was categorised as 'major', with the patient requiring expedited surgery. The remainder (99 patients) were categorised as having experienced minor complications. The incidence of complications after 'other' injections was significantly greater than for other categories of injection (1.86%, p = 0.028). There was no significant difference in the complication rate for cervical spine (0.93%, p = 0.257), lumbar nerve root (0.85%, p = 0.401), lumbar facet joint (0.67%, p = 0.326) or caudal epidural (1.29%, p = 0.687) injections. 'Other' injections were subsequently further sub-categorised by anatomical site and imaging modality used. Glenohumeral (2.97%, p = 0.0361) and sacro-iliac (3.51%, p = 0.0498) joint injections were associated with a significantly increased risk of complications. There was no difference in the incidence of complications with fluoroscopic or ultrasound guidance. CONCLUSION: In conclusion, image-guided musculoskeletal injections are safe and well-tolerated procedures. Complications are rare, occurring in just 1.2% of patients. 99% of complications are minor, either not requiring intervention or resolving with simple supportive treatment.


Subject(s)
Cervical Vertebrae , Zygapophyseal Joint , Fluoroscopy , Humans , Injections, Epidural/adverse effects , Injections, Intra-Articular , Spinal Nerve Roots
14.
Emerg Radiol ; 26(6): 631, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31468206

ABSTRACT

The above article was published online with an error in an author's last name: It should be Muzikansky (and not Muzikanski). The correct name is presented here. The original article has been corrected.

15.
Emerg Radiol ; 26(6): 623-630, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31376018

ABSTRACT

PURPOSE: Patients with acute pulmonary embolism (PE) can quickly deteriorate and the condition has high mortality due to right ventricular (RV) failure. Immediately available predictors of adverse outcome are of major interest to the treating physician in the acute setting. The purpose of the present study was to evaluate if easily attainable measurements of RV function from the diagnostic computed tomography pulmonary angiography (CTPA) provide information for fast risk stratification in patients with acute PE. METHODS: We retrospectively evaluated images from CTPA in 261 patients (age median 60 years, 50% females) enrolled in a prospective study. RV and left ventricular (LV) diameters and their ratio, the presence of septal bowing, contrast reflux in the inferior vena cava, and the diameter of the central pulmonary arteries (PA) were measured. The composite outcome was 5-day severe adverse events including death, acute decompensation, or need for emergent treatment. We used Wilcoxon rank sum test and Fischer's exact test to test between groups and multivariate logistic regression for prediction. RESULTS: In multivariate analysis, increased diameter of the main PA (OR = 1.08 per 1 mm increase, p = 0.047) and the presence of septal bowing (OR = 2.23, p = 0.055) were associated with severe adverse events. RV/LV > 1 did not predict severe outcomes (OR = 0.73, p = 0.541). CONCLUSIONS: Two easily attainable parameters of RV function on CTPA, septal bowing and main PA diameter, are associated with short-term adverse outcomes in patients with acute PE. Further study is required to determine whether these findings can be incorporated into clinical treatment algorithms.


Subject(s)
Computed Tomography Angiography , Pulmonary Artery/diagnostic imaging , Pulmonary Embolism/diagnostic imaging , Acute Disease , Aged , Contrast Media , Female , Heart Ventricles/diagnostic imaging , Humans , Iopamidol , Male , Middle Aged , Retrospective Studies , Vena Cava, Inferior/diagnostic imaging
16.
AJR Am J Roentgenol ; 213(5): 1117-1123, 2019 11.
Article in English | MEDLINE | ID: mdl-31287723

ABSTRACT

OBJECTIVE. The purpose of this study was to assess the result of adding cone-beam CT to the standard imaging algorithm for patients with suspected radiographically occult traumatic radiocarpal fractures. SUBJECTS AND METHODS. A prospective review was performed on all patients who had cone-beam CT investigation of acute wrist pain after normal initial radiographs. Patients with no identified fractures were clinically reassessed and referred for MRI if concern for a fracture persisted. RESULTS. In all, 117 patients were assessed; 50.4% had fractures identified with a total of 67 radiographically occult fractures. One fracture was identified on MRI that was not seen on cone-beam CT. Cone-beam CT had sensitivity of 98.3% (95% CI, 91.1-100%), specificity of 100% (95% CI, 93.7-100%), positive predictive value of 100%, and negative predictive value of 98.3% (95% CI, 89.1-100%). Accuracy was 99.1% (95% CI, 95.3-100%). CONCLUSION. Incorporating cone-beam CT into routine clinical practice as part of a standardized diagnostic algorithm yielded a 50% fracture detection rate in patients with negative wrist radiographs but ongoing clinical concern for radiocarpal fracture. Cone-beam CT provides more diagnostic information than radiographs at a lower radiation dose than conventional MDCT. Given the poor accuracy of radiographs for acute radiocarpal fractures and the high fracture prevalence in this cohort, we feel that cone-beam CT should be regarded as the new standard of care in the investigation of these patients.


Subject(s)
Algorithms , Carpal Bones/diagnostic imaging , Carpal Bones/injuries , Cone-Beam Computed Tomography , Fractures, Closed/diagnostic imaging , Radius Fractures/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Diagnosis, Differential , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Prospective Studies , Sensitivity and Specificity
17.
Ir J Med Sci ; 188(4): 1385-1389, 2019 Nov.
Article in English | MEDLINE | ID: mdl-30875006

ABSTRACT

BACKGROUND: There has been a year on year increase in imaging requests at our academic institution. The iRefer guidelines are produced by the Royal College of Radiologists in the UK and are designed to prevent inappropriate imaging and radiation exposure. They have been available to general practitioners and hospital physicians in Ireland since March 2015. AIMS: Our aims were to determine the proportion of inappropriate imaging referrals pre- and post-guideline introduction and to calculate the cost and dose estimates for inappropriate scans. METHODS: A retrospective review of 1124 radiographs was performed with reference to a validated audit template. Emergency department, in-patient, and general practitioner referrals were reviewed. Cost and cumulative dose estimates were calculated for inappropriate referrals taking into account salaries, average time spent performing/reporting radiographs, and median effective dose values. RESULTS: The introduction of the iRefer guidelines has not significantly affected the proportion of inappropriate radiograph referrals at our institution, 42% pre-introduction and 43% post-introduction. We identified 784 inappropriate referrals across 6 radiograph subtypes, imparting a total median effective dose of 65.1 mSv to patients. The time spent performing inappropriate abdominal and spinal radiographs in 2017 yielded an estimated cost of €8036.40. CONCLUSION: A significant amount of inappropriate radiographs continue to be requested and performed, exposing patients to needless ionizing radiation and wasting staff members time at a financial cost. Interventions are needed to decrease inappropriate referrals.


Subject(s)
Emergency Service, Hospital/statistics & numerical data , Radiography/statistics & numerical data , Radiology/statistics & numerical data , Referral and Consultation/statistics & numerical data , Humans , Ireland , Retrospective Studies
18.
Emerg Radiol ; 26(3): 319-329, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30706257

ABSTRACT

In this paper, we propose a CT imaging algorithm for patients presenting with suspected acute stroke that incorporates automated CT perfusion (CTP) imaging. The algorithm details evaluation of the non-contrast CT (NCCT) for hemorrhage and acute ischemia, calculation of ASPECTS, with performance and interpretation of CTP if appropriate. In particular, we consider the key steps in expeditious interpretation of non-contrast CT and CT angiography in the context of suspected acute ischemic stroke. Given the recent expansion of the "imaging based" treatment window for thrombectomy from 6 to 24 h in the 2018 American Heart Association stroke guidelines, we consider the key criteria in the decision to perform CT perfusion and the patient cohorts in which this might be most helpful. We also describe how imaging findings might be incorporated into the treatment paradigm for suspected with acute ischemic stroke and we allude to some of the most frequently encountered pitfalls associated with CTP which we think will be particularly helpful for radiologists and stroke physicians who are considering adding CT perfusion to their work-up for acute stroke.


Subject(s)
Algorithms , Brain Ischemia/diagnostic imaging , Cerebral Angiography/methods , Computed Tomography Angiography/methods , Stroke/diagnostic imaging , Cerebrovascular Circulation , Decision Making , Humans
19.
Eur Radiol ; 28(4): 1731-1738, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29134350

ABSTRACT

OBJECTIVE: To describe and evaluate a novel technical development to improve detection of intracranial vessel occlusions using multiphase CT angiography (MPCTA). MATERIALS AND METHODS: The institutional ethics committee approved the study. Fifty patients (30 consecutive distal (M2 or smaller) anterior circulation occlusions, ten M1 occlusions, ten cases without occlusion) presenting with suspected AIS who underwent MPCTA were included. Post-processing of MPCTA studies created "subtraction" and "delayed enhancement" (DE) datasets. Initially, non-contrast CT and MPCTA studies for each patient were evaluated. Readers' confidence, speed and sensitivity of detection of intracranial vessel occlusions were recorded. After an interval of at least 4 weeks, readers were provided with post-processed images and studies were re-evaluated. RESULTS: While the sensitivity of detection of intracranial vessel occlusions was equal for both conventional MPCTA and subMPCTA, the mean time taken to identify a vessel occlusion decreased by 64 % using subMPCTA (16 s vs. 45 s with conventional MPCTA) (p<0.001). In addition, confidence in interpretation improved (from 4.4 to 4.9) using subMPCTA (p<0.001). CONCLUSION: SubMPCTA is a novel technique that aids in identifying small intracranial vessel occlusions in the suspected AIS patient. SubMPCTA increases confidence in interpretation and reduces the time taken to detect intracranial vessel occlusions. KEY POINTS: • SubMPCTA processes MPCTA data to better demonstrate intracranial arterial occlusions. • SubMPCTA increases confidence and speed of interpretation of MPCTA studies. • SubMPCTA may aid in rapidly differentiating acute ischaemic stroke from stroke mimics.


Subject(s)
Angiography, Digital Subtraction/methods , Arterial Occlusive Diseases/diagnostic imaging , Brain Ischemia/diagnostic imaging , Cerebral Angiography/methods , Computed Tomography Angiography/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted
20.
AJR Am J Roentgenol ; 207(3): 526-33, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27341350

ABSTRACT

OBJECTIVE: Spinal injections are common pain management procedures using corticosteroids and local anesthetics. Most corticosteroid preparations are particulate suspensions, such as methylprednisolone acetate and triamcinolone acetonide. In the cervical spine, particulate corticosteroids have been linked to catastrophic complications, including blindness, paralysis, and death. Serious neurologic injuries have also been reported at the thoracic, lumbar, and sacral levels. CONCLUSION: Nonparticulate preparations, such as dexamethasone, are safer but have shorter-lived antiinflammatory effects. Local anesthetics are often mixed with corticosteroids in pain management procedures. Although everyday risks are minimal, injection techniques should take into account neural and cardiac toxicities. In this article, we discuss the potential for serious adverse events associated with injected medications. We review the current literature to make conclusions on medication combinations that balance safety and efficacy.


Subject(s)
Adrenal Cortex Hormones/therapeutic use , Anesthetics, Local/therapeutic use , Injections, Spinal/methods , Pain Management , Adrenal Cortex Hormones/adverse effects , Anesthetics, Local/adverse effects , Drug Combinations , Humans , Injections, Spinal/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL