Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
J Clin Microbiol ; 61(12): e0079923, 2023 12 19.
Article in English | MEDLINE | ID: mdl-37971271

ABSTRACT

In 2017, the Centers for Disease Control and Prevention (CDC) established the Antimicrobial Resistance Laboratory Network to improve domestic detection of multidrug-resistant organisms. CDC and four laboratories evaluated a commercial broth microdilution panel. Antimicrobial susceptibility testing using the Sensititre GN7F (ThermoFisher Scientific, Lenexa, KS) was evaluated by testing 100 CDC and Food and Drug Administration AR Isolate Bank isolates [40 Enterobacterales (ENT), 30 Pseudomonas aeruginosa (PSA), and 30 Acinetobacter baumannii (ACB)]. We assessed multiple amounts of transfer volume (TV) between the inoculum and tubed 11-mL cation-adjusted Mueller-Hinton broth: 1 µL [tribe Proteeae (P-tribe) only] and 10, 30, and 50 µL, resulting in respective CFU per milliter of 1 × 104, 1 × 105, 3 × 105, and 5 × 105. Four TV combinations were analyzed: standard (STD) [1 µL (P-tribe) and 10 µL], enhanced standard (E-STD) [1 µL (P-tribe) and 30 µL], 30 µL, and 50 µL. Essential agreement (EA), categorical agreement, major error (ME), and very major error (VME) were analyzed by organism then TVs. For ENT, the average EA across laboratories was <90% for 7 of 15 ß-lactams using STD and E-STD TVs. As TVs increased, EA increased (>90%), and VMEs decreased. For PSA, EA improved as TVs increased; however, MEs also increased. For ACB, increased TVs provided slight EA improvements; all TVs yielded multiple VMEs and MEs. For ENT and ACB, Minimum inhibitory concentrations (MICs) trended downward using a 1 or 10 µL TV; there were no obvious MIC trends by TV for PSA. The public health and clinical consequences of missing resistance warrant increased TV of 30 µL for the GN7F, particularly for P-tribe, despite being considered "off-label" use.


Subject(s)
Acinetobacter baumannii , Pseudomonas Infections , Humans , Anti-Bacterial Agents/pharmacology , Laboratories , Drug Resistance, Bacterial , Microbial Sensitivity Tests , Pseudomonas aeruginosa
4.
Microbiol Resour Announc ; 10(1)2021 Jan 07.
Article in English | MEDLINE | ID: mdl-33414286

ABSTRACT

Thirty Clostridioides difficile isolates collected in 2016 through the Centers for Disease Control and Prevention Emerging Infections Program were selected for reference antimicrobial susceptibility testing and whole-genome sequencing. Here, we present the genetic characteristics of these isolates and announce their availability in the CDC & FDA Antibiotic Resistance Isolate Bank.

5.
J Antimicrob Chemother ; 76(4): 979-983, 2021 03 12.
Article in English | MEDLINE | ID: mdl-33367916

ABSTRACT

BACKGROUND: Aztreonam/avibactam is a combination agent that shows promise in treating infections caused by highly antibiotic-resistant MBL-producing Enterobacterales. This combination can be achieved by combining two FDA-approved drugs: ceftazidime/avibactam and aztreonam. It is unknown whether ceftazidime in the combination ceftazidime/aztreonam/avibactam has a synergistic or antagonistic effect on the in vitro activity of aztreonam/avibactam by significantly increasing or decreasing the MIC. OBJECTIVES: To determine whether increasing ceftazidime concentrations affect the MICs of aztreonam/avibactam alone. METHODS: A custom 8 × 8 chequerboard broth microdilution (BMD) panel was made using a digital dispenser (Hewlett-Packard, Corvallis, OR, USA). The panel included orthogonal 2-fold dilution series of aztreonam and ceftazidime ranging from 0.5 to 64 mg/L. Avibactam concentration was kept constant at 4 mg/L throughout the chequerboard. Thirty-seven Enterobacterales isolates from the CDC & FDA Antibiotic Resistance Isolate Bank or CDC's internal collection with intermediate or resistant interpretations to aztreonam and ceftazidime/avibactam were included for testing. All isolates harboured at least one of the following MBL genes: blaIMP, blaNDM or blaVIM. RESULTS: Regardless of the concentration of ceftazidime, aztreonam/avibactam with ceftazidime MICs for all 37 isolates were within one 2-fold doubling dilution of the aztreonam/avibactam MIC. CONCLUSIONS: Ceftazidime, in the combination ceftazidime/avibactam/aztreonam, did not affect the in vitro activity of aztreonam/avibactam in this sample of isolates. These findings can help assure clinical and public health laboratories that testing of aztreonam/avibactam by BMD can act as a reliable surrogate test when the combination of ceftazidime/avibactam and aztreonam is being considered for treatment of highly antibiotic-resistant MBL-producing Enterobacterales.


Subject(s)
Aztreonam , Ceftazidime , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use , Azabicyclo Compounds/pharmacology , Aztreonam/pharmacology , Ceftazidime/pharmacology , Drug Combinations , Microbial Sensitivity Tests , beta-Lactamases
6.
J Clin Microbiol ; 58(4)2020 03 25.
Article in English | MEDLINE | ID: mdl-32051259

ABSTRACT

Aztreonam-avibactam is a combination antimicrobial agent with activity against carbapenemase-producing Enterobacteriaceae (CPE) with metallo-ß-lactamases (MßLs). Although aztreonam-avibactam is not yet approved by the U.S. Food and Drug Administration (FDA), clinicians can administer this combination by using two FDA-approved drugs: aztreonam and ceftazidime-avibactam. This combination of drugs is recommended by multiple experts for treatment of serious infections caused by MßL-producing CPE. At present, in vitro antimicrobial susceptibility testing (AST) of aztreonam-avibactam is not commercially available; thus, most clinicians receive no laboratory-based guidance that can support consideration of aztreonam-avibactam for serious CPE infections. Here, we report our internal validation for aztreonam-avibactam AST by reference broth microdilution (BMD) according to Clinical and Laboratory Standards Institute (CLSI) guidelines. The validation was performed using custom frozen reference BMD panels prepared in-house at the Centers for Disease Control and Prevention (CDC). In addition, we took this opportunity to evaluate a new panel-making method using a digital dispenser, the Hewlett Packard (HP) D300e. Our studies demonstrate that the performance characteristics of digitally dispensed panels were equivalent to those of conventionally prepared frozen reference BMD panels for a number of drugs, including aztreonam-avibactam. We found the HP D300e digital dispenser to be easy to use and to provide the capacity to prepare complex drug panels. Our findings will help other clinical and public health laboratories implement susceptibility testing for aztreonam-avibactam.


Subject(s)
Aztreonam , Enterobacteriaceae , Microbial Sensitivity Tests , Anti-Bacterial Agents/pharmacology , Azabicyclo Compounds , Aztreonam/pharmacology , Ceftazidime , Drug Combinations , beta-Lactamases
8.
J Clin Microbiol ; 56(2)2018 02.
Article in English | MEDLINE | ID: mdl-29118174

ABSTRACT

The FDA-CDC Antimicrobial Resistance Isolate Bank was created in July 2015 as a publicly available resource to combat antimicrobial resistance. It is a curated repository of bacterial isolates with an assortment of clinically important resistance mechanisms that have been phenotypically and genotypically characterized. In the first 2 years of operation, the bank offered 14 panels comprising 496 unique isolates and had filled 486 orders from 394 institutions throughout the United States. New panels are being added.


Subject(s)
Bacteria/isolation & purification , Biological Specimen Banks , Drug Resistance, Microbial , Fungi/isolation & purification , Anti-Infective Agents/pharmacology , Bacteria/drug effects , Bacteria/genetics , Biological Specimen Banks/organization & administration , Biological Specimen Banks/standards , Centers for Disease Control and Prevention, U.S. , Communicable Diseases/diagnosis , Communicable Diseases/microbiology , Fungi/drug effects , Fungi/genetics , Humans , United States , United States Food and Drug Administration
9.
Free Radic Res ; 40(6): 565-70, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16753833

ABSTRACT

The objective of the work was to study the relationship between the oxidative state of the mother and the newborn at the moment of birth. We measured oxidative stress markers (carbonyl groups, lipid peroxides and total antioxidant capacity (TAC)) and found a good correlation between the oxidative state of the normal mother and the neonate, since a high mother oxidative stress corresponds to an even higher oxidative stress of the newborn in umbilical cord blood. We also found that smoking mothers and their newborns had a higher concentration of the carbonyl group, lipid peroxides and less TAC. Newborns from these mothers weighed significantly less than others at birth. These data suggest a need for interest in monitoring the oxidative state of mothers during the pregnancy period, especially taking into account that the oxidative level could be involved in later risks of metabolic diseases for both mother and newborn.


Subject(s)
Biomarkers/blood , Fetal Blood/metabolism , Oxidative Stress , Adult , Antioxidants/metabolism , Female , Humans , Infant, Newborn , Lipid Peroxidation , Mothers , Oxytocin/metabolism , Patient Admission
10.
Rev. do IHB ; 1(1): 36-8, 1992. quadro
Article in Portuguese | HomeoIndex Homeopathy | ID: hom-4585

ABSTRACT

Estudo de pesquisa para ver os contaminantes da agua destilada e deionizada, sendo redomendada a agua destilada, com as devidas precaucoes


Subject(s)
Water Quality , Homeopathic Pharmacy Techniques , Homeopathic Vehicles , Distilled Water , Quality of Homeopathic Remedies
SELECTION OF CITATIONS
SEARCH DETAIL
...