J Hosp Infect ; 150: 34-39, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38823646

ABSTRACT

BACKGROUND: Biofilms on dry hospital surfaces can enhance the persistence of micro-organisms on dry harsh clinical surfaces and can potentially act as reservoirs of infectious agents on contaminated surfaces. AIM: This study was conducted to quantify the transfer of viable Staphylococcus aureus cells from dry biofilms through touching and to investigate the impact of nutrient and moisture deprivation on virulence levels in S. aureus. METHODS: Dry biofilms of S. aureus ATCC 25923 and a defective biofilm-forming ability mutant, S. aureus 1132, were formed in 24-well plates under optimized conditions mimicking dry biofilm formation on clinical surfaces. Microbial cell transfer was induced through the touching of the dry biofilms, which were quantified on nutrient agar. To investigate the impact of nutrient and moisture deprivation on virulence levels, dry and standard biofilms as well as planktonic cells of S. aureus ATCC 25923 were inoculated into Galleria mellonella and their kill rates compared. FINDINGS: Results of this study showed that viable cells from dry biofilms of S. aureus ATCC 25923 were significantly more virulent and readily transferrable from dry biofilms through a touch test, therefore representing a greater risk of infection. The biofilm-forming capability of S. aureus strains had no significant impact on their transferability with more cells transferring when biofilm surfaces were wet. CONCLUSIONS: These findings indicate that dry biofilms on hospital surfaces may serve as a reservoir for the dissemination of pathogenic micro-organisms in hospitals, thus highlighting the importance of regular cleaning and adequate disinfection of hospital surfaces.

2.
J Hosp Infect ; 107: 67-75, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33098959

ABSTRACT

INTRODUCTION: The reduced susceptibility of biofilms to disinfectants presents a challenge to the successful reprocessing of medical equipment. This study examined the effect of residual biomass remaining after previous disinfection with peracetic acid (PAA) on the tolerance of subsequent mature Pseudomonas aeruginosa biofilms to PAA. The effect of enzymatic degradation of specific components of the extracellular polymeric substance (EPS) of P. aeruginosa biofilm on the effectiveness of PAA disinfection was also evaluated. METHODS: The susceptibility of biofilm grown on the biomass of PAA-killed biofilm to PAA was compared with the PAA susceptibility of biofilm grown in wells of a 24-well plate by evaluating their viability using the plate count assay. The effect of PAA on biofilm biomass was measured using crystal violet quantification of total biofilm biomass, while its effect on the polysaccharide and protein components of biofilm EPS was quantified using the phenol-sulphuric acid assay or Bradford assay, respectively. A confocal microscope was used to visualize the distribution of living and dead cells in biofilms grown on residual biofilm biomass. FINDINGS: The presence of residual biomass from previously disinfected biofilms significantly enhanced the tolerance of subsequent biofilms. A 96-h-old 'secondary biofilm' formed on disinfected biomass survived PAA concentrations of 4000 ppm, which exceeds the concentrations used in practice for high-level disinfection. CONCLUSION: These observations indicate that, under certain circumstances, recolonization of residual EPS can cause failure of disinfection of medical equipment such as endoscopes, and emphasizes the importance of cleaning endoscopes prior to disinfection.


Subject(s)
Biofilms , Disinfectants , Disinfection , Endoscopes/microbiology , Equipment Contamination , Peracetic Acid , Extracellular Polymeric Substance Matrix , Pseudomonas aeruginosa/drug effects
3.
J Hosp Infect ; 106(1): 189-195, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32599010

ABSTRACT

INTRODUCTION: The ability of healthcare-associated infection pathogens to survive on environmental surfaces is well known. Disinfection is employed to reduce or remove these pathogens but disinfection failures still occur. One method with the potential to improve disinfection efficacy is whole-room disinfection with hydrogen peroxide (H2O2). AIM: To determine the influence of delivery system on the efficacy of low-concentration H2O2 on common healthcare-associated infection pathogens. METHODS: SanoStatic (electrostatic spray) was compared with SanoFog (fogging) in terms of performance for delivery of 5% H2O2 and trace silver ions for disinfection. The bacterial test challenges were vancomycin-resistant Enterobacterales (VRE), extended-spectrum ß-lactamase (ESBL)-producing Klebsiella pneumoniae (ESBLK), carbapenemase-producing Enterobacterales (CPE), meticillin-resistant Staphylococcus aureus (MRSA), Clostridium difficile spores, Bacillus atropheus and Geobacillus stearothermophilus commercial spore strips. FINDINGS: SanoFog and SanoStatic were effective when tested under the conditions of experimentation reported here. For VRE, ESBLK, CPE and MRSA, SanoFog and SanoStatic were comparable in performance. For C. difficile we concluded the following: SanoFog was most effective for disinfection of C. difficile spores when compared to SanoStatic. CONCLUSION: Whereas SanoFog and SanoStatic were effective against bacterial cells, the current practice of using SanoFog and SanoStatic together would be effective for disinfection of C. difficile spores based on investigations under the conditions of experimentation reported here. The spore strips results were not comparable to the results either for the vegetation cells (VRE, ESBLK, CPE, and MRSA) or for C. difficile spores.


Subject(s)
Bacteria/drug effects , Disinfectants/pharmacology , Disinfection/methods , Hydrogen Peroxide/pharmacology , Bacteria/pathogenicity , Colony Count, Microbial , Microbial Sensitivity Tests , Surface Properties
4.
Clin Microbiol Infect ; 26(7): 941.e1-941.e7, 2020 Jul.
Article in English | MEDLINE | ID: mdl-31715298

ABSTRACT

OBJECTIVES: Clostridioides difficile infection (CDI) is a considerable healthcare and economic burden worldwide. Faecal microbial transplant remains the most effective treatment for CDI, but is not at the present time the recommended standard of care. We hereby investigate which factors derived from a healthy gut microbiome might constitute the colonization resistance barrier (CRB) in the gut, inhibiting CDI. METHODS: CRB drivers pH, short chain fatty acid (SCFA), and oxidation-reduction potential (ORP) were investigated in vitro using C. difficile NAP1/BI/027. Readouts for inhibitory mechanisms included germination, growth, toxin production and virulence gene expression. pH ranges (3-7.6), SCFA concentrations (25-200 mM) and ORP (-300 to 200 mV) were manipulated in brain heart infusion broth cultures under anaerobic conditions to assess the inhibitory action of these mechanisms. RESULTS: A pH < 5.3 completely inhibited C. difficile growth to optical density (OD) 0.019 vs. 1.19 for control pH 7.5. Toxin production was reduced to 25 units vs. 3125 units for pH 7.6 (1 in 5 dilutions). Virulence gene expression reduced by 150-fold compared with pH 7.6 (p < 0.05). Germination and proliferation of spores below pH 6.13 yielded an average OD of 0.006 vs. 0.99 for control. SCFA were potent regulators of toxin production at 25 mM and above (p < 0.05). Acetate significantly inhibited toxin production to 25 units independent of OD (0.8733) vs. control (OD 0.6 and toxin titre 3125) (p < 0.05). ORP did not impact C. difficile growth. CONCLUSIONS: This study highlights the critical role that pH has in the CRB, regulating CDI in vitro and that SCFA can regulate C. difficile function independent of pH.


Subject(s)
Acetates/pharmacology , Bacterial Toxins/metabolism , Clostridioides difficile/physiology , Virulence Factors/genetics , Animals , Bacterial Toxins/genetics , Bacteriological Techniques , Chlorocebus aethiops , Clostridioides difficile/growth & development , Clostridioides difficile/metabolism , Clostridioides difficile/pathogenicity , Gene Expression Regulation, Bacterial , Humans , Hydrogen-Ion Concentration , Ribotyping , Spores, Bacterial/growth & development , Spores, Bacterial/physiology , Vero Cells
5.
J Hosp Infect ; 98(4): 433-436, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29203448

ABSTRACT

The emerging pathogenic multidrug-resistant yeast Candida auris is an important source of healthcare-associated infections and of growing global clinical concern. The ability of this organism to survive on surfaces and withstand environmental stressors creates a challenge for eradicating it from hospitals. A panel of C. auris clinical isolates was evaluated on different surface environments against the standard disinfectant sodium hypochlorite and high-level disinfectant peracetic acid. C. auris was shown to selectively tolerate clinically relevant concentrations of sodium hypochlorite and peracetic acid in a surface-dependent manner, which may explain its ability to successfully persist within the hospital environment.


Subject(s)
Candida/drug effects , Candida/isolation & purification , Disinfectants/pharmacology , Environmental Microbiology , Microbial Viability/drug effects , Peracetic Acid/pharmacology , Sodium Hypochlorite/pharmacology , Candida/physiology
6.
J Hosp Infect ; 96(1): 59-62, 2017 May.
Article in English | MEDLINE | ID: mdl-28318779

ABSTRACT

There is a lack of published studies on laundering in ambulance services. We performed bacterial culture on soiled and unsoiled uniforms and reusable mop heads artificially contaminated with Escherichia coli, Staphylococcus aureus, and Clostridium difficile spores. Current laundering processes used for routine cleans in the ambulances appears, from our simulations, to be effective at reducing vegetative pathogenic bacteria to undetectable levels, <3.398log10 colony-forming units (S. aureus and E. coli). Reduced levels of C. difficile were still detected after laundering but the risk this poses for infection is unknown, as background levels of these spores in the environment are unknown.


Subject(s)
Ambulances , Clothing/supply & distribution , Equipment Reuse/standards , Infection Control/methods , Laundering/standards , Clostridioides difficile/growth & development , Clostridioides difficile/isolation & purification , Clothing/standards , Colony Count, Microbial/statistics & numerical data , Cross Infection/microbiology , Decontamination/standards , Decontamination/statistics & numerical data , Disinfection/standards , Disinfection/statistics & numerical data , Escherichia coli/growth & development , Escherichia coli/isolation & purification , Humans , Infection Control/statistics & numerical data , Methicillin-Resistant Staphylococcus aureus/growth & development , Methicillin-Resistant Staphylococcus aureus/isolation & purification , Scotland/epidemiology , Staphylococcus aureus/growth & development , Staphylococcus aureus/isolation & purification , Stem Cells/microbiology , Workforce
7.
Rev Sci Instrum ; 87(11): 115116, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910557

ABSTRACT

A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of 10-29 e ⋅ cm by using polarized "magic" momentum 0.7 GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the standard model at the scale of 3000 TeV.

8.
J Hosp Infect ; 93(3): 242-55, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27112048

ABSTRACT

Investigations into the suspected airborne transmission of pathogens in healthcare environments have posed a challenge to researchers for more than a century. With each pathogen demonstrating a unique response to environmental conditions and the mechanical stresses it experiences, the choice of sampling device is not obvious. Our aim was to review bioaerosol sampling, sampling equipment, and methodology. A comprehensive literature search was performed, using electronic databases to retrieve English language papers on bioaerosol sampling. The review describes the mechanisms of popular bioaerosol sampling devices such as impingers, cyclones, impactors, and filters, explaining both their strengths and weaknesses, and the consequences for microbial bioefficiency. Numerous successful studies are described that point to best practice in bioaerosol sampling, from the use of small personal samplers to monitor workers' pathogen exposure through to large static samplers collecting airborne microbes in various healthcare settings. Of primary importance is the requirement that studies should commence by determining the bioefficiency of the chosen sampler and the pathogen under investigation within laboratory conditions. From such foundations, sampling for bioaerosol material in the complexity of the field holds greater certainty of successful capture of low-concentration airborne pathogens. From the laboratory to use in the field, this review enables the investigator to make informed decisions about the choice of bioaerosol sampler and its application.


Subject(s)
Aerosols , Air Microbiology , Health Facilities , Microbiological Techniques/instrumentation , Microbiological Techniques/methods
9.
Eur J Clin Microbiol Infect Dis ; 34(11): 2161-6, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26354525

ABSTRACT

Clostridium difficile is the dominant cause of pseudomembranous colitis in nosocomial environments. C. difficile infection (CDI) generally affects elderly (≥65 years of age) hospital inpatients who have received broad-spectrum antimicrobial treatment. CDI has a 30 % risk of re-infection and a subsequent 60 % risk of relapse thereafter, leading to a high economic burden of over 7 billion pounds sterling and over 900,000 cases in the USA and Europe per annum. With the long-term consequences of faecal transplantation currently unknown, and limited spectrum of effective antibiotics, there is an urgent requirement for alternative means of preventing and treating CDI in high-risk individuals. Metagenomics has recently improved our understanding of the colonisation resistance barrier and how this could be optimised. pH, oxidation-reduction potentials and short-chain fatty acids have been suggested to inhibit C. difficile growth and toxin production in in vitro and in vivo studies. This review aims to pull together the evidence in support of a colonisation resistance barrier against CDI.


Subject(s)
Carrier State/prevention & control , Clostridioides difficile/immunology , Cross Infection/prevention & control , Enterocolitis, Pseudomembranous/prevention & control , Gastrointestinal Tract/immunology , Aged , Aged, 80 and over , Carrier State/epidemiology , Carrier State/immunology , Cross Infection/epidemiology , Cross Infection/immunology , Enterocolitis, Pseudomembranous/epidemiology , Enterocolitis, Pseudomembranous/microbiology , Europe/epidemiology , Fatty Acids/metabolism , Humans , Hydrogen-Ion Concentration , Oxidation-Reduction , United States/epidemiology
10.
Eur J Clin Microbiol Infect Dis ; 33(12): 2121-30, 2014 Dec.
Article in English | MEDLINE | ID: mdl-24993151

ABSTRACT

The demographics of the healthcare population are changing, with an ever-greater proportion of people being treated outside the traditional hospital setting through community healthcare. This shift in the way that healthcare is delivered raises new concerns over community healthcare-associated infections (HCAIs). A literature search between 2000 and December 2013 was conducted in databases including PubMed, SciVerse ScienceDirect and Google Scholar. National and international guideline and policy documents were searched using Google. Many terms were used in the literature searches, including 'nosocomial', 'healthcare infection', 'community' and 'nursing home'. The rates of HCAI in community healthcare are similar to the rates found in the acute hospital setting, but the types of infection differ, with a greater focus on urinary tract infections (UTIs) in the community and ventilator-associated pneumonias in the hospital setting. Patients who acquire a community HCAI are more likely to exhibit reduced physical condition, have increased levels of morbidity and have higher mortality rates than individuals without infection. Infection control programmes have been developed worldwide to reduce the rates of hospital HCAIs. Such interventions are equally as valid in the community, but how best to implement them and their subsequent impact are much less well understood. The future is clear: HCAIs in the community are going to become an ever-increasing burden and it is critical that our approach to these infections is brought quickly in line with present hospital sector standards.


Subject(s)
Community Health Services/methods , Cross Infection/prevention & control , Infection Control/methods , Humans , Nursing Homes
11.
Clin Exp Immunol ; 173(3): 512-22, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23668840

ABSTRACT

In this study, we hypothesized that the granulomatous disorder sarcoidosis is not caused by a single pathogen, but rather results from abnormal responses of Toll-like receptors (TLRs) to conserved bacterial elements. Unsorted bronchoalveolar lavage (BAL) cells from patients with suspected pulmonary sarcoidosis and healthy non-smoking control subjects were stimulated with representative ligands of TLR-2 (in both TLR-2/1 and TLR-2/6 heterodimers) and TLR-4. Responses were determined by assessing resulting production of tumour necrosis factor (TNF)-α and interleukin (IL)-6. BAL cells from patients in whom sarcoidosis was confirmed displayed increased cytokine responses to the TLR-2/1 ligand 19-kDa lipoprotein of Mycobacterium tuberculosis (LpqH) and decreased responses to the TLR-2/6 agonist fibroblast stimulating ligand-1 (FSL)-1. Subsequently, we evaluated the impact of TLR-2 gene deletion in a recently described murine model of T helper type 1 (Th1)-associated lung disease induced by heat-killed Propionibacterium acnes. As quantified by blinded scoring of lung pathology, P. acnes-induced granulomatous pulmonary inflammation was markedly attenuated in TLR-2(-/-) mice compared to wild-type C57BL/6 animals. The findings support a potential role for disordered TLR-2 responses in the pathogenesis of pulmonary sarcoidosis.


Subject(s)
Sarcoidosis, Pulmonary/metabolism , Toll-Like Receptor 2/metabolism , Adolescent , Adult , Aged , Animals , Bronchoalveolar Lavage Fluid/cytology , Bronchoalveolar Lavage Fluid/immunology , Case-Control Studies , Cytokines/biosynthesis , Disease Models, Animal , Female , Gene Expression , Humans , Ligands , Male , Mice , Mice, Knockout , Middle Aged , Pneumonia/genetics , Pneumonia/immunology , Propionibacterium acnes/immunology , Protein Multimerization , Sarcoidosis, Pulmonary/genetics , Sarcoidosis, Pulmonary/immunology , Toll-Like Receptor 2/antagonists & inhibitors , Toll-Like Receptor 2/genetics , Toll-Like Receptor 4/agonists , Toll-Like Receptor 4/metabolism , Toll-Like Receptors/chemistry , Toll-Like Receptors/genetics , Toll-Like Receptors/metabolism , Young Adult
12.
Gastroenterol Res Pract ; 2011: 491035, 2011.
Article in English | MEDLINE | ID: mdl-21811496

ABSTRACT

Helicobacter pylori infection, often acquired in early childhood, is a global cause of undernutrition, gastritis, peptic ulcer disease and gastric carcinoma. This study tested the feasibility of using H. pylori shed in the faeces as a source of DNA for non-invasive epidemiological studies. H. pylori DNA was chemically recovered and isolated using a specific biotinylated oligonucleotide probe with magnetic capture from 28 H. pylori positive faecal samples obtained from children attending hospital for the investigation of suspected H. pylori infection, together with close family members. Random amplification of polymorphic DNA (RAPD) was subsequently used to discriminate each isolate. 93% of stool samples selected were typeable. Parent, child and sibling samples were compared and similarities determined. Phylogenetic analysis showed that H. pylori DNA obtained from the faeces can be used to genotype individual strains, offering a means of studying intrafamilial transfer of this microorganism.

13.
J Insect Sci ; 10: 111, 2010.
Article in English | MEDLINE | ID: mdl-20874568

ABSTRACT

Morphology is the most direct approach biologists have to recognize uniqueness of insect species as compared to close relatives. Ants of the genus Procryptocerus possess important morphologic characters yet have not been explored for use in a taxonomic revision. The genus is characterized by the protrusion of the clypeus forming a broad nasus and antennal scrobes over the eyes. The toruli are located right posterior to the flanks of the nasus opposite to each other. The vertex is deflexed posteriorly in most species. An in-group comparison of the external morphology is presented focusing on the workers. A general morphology for gynes and males is also presented. Previously mentioned characters as well as new ones are presented, and their character states in different species are clarified. For the metasoma a new system of ant metasomal somite nomenclature is presented that is applicable to Aculeata in general. Finally, a Glossary of morphological terms is offered for the genus (available online). Most of the terminology can be used in other members of the Formicidae and Aculeata.


Subject(s)
Ants/anatomy & histology , Animals , Ants/classification , Female , Head/anatomy & histology , Male , Pigmentation , Sex Characteristics , Wings, Animal/anatomy & histology
14.
J Microbiol Methods ; 82(2): 131-5, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20493214

ABSTRACT

An external quality assessment (EQA) panel consisting of a total of 13 samples in broncho alveolar lavage (BAL) or transport medium was prepared to assess the proficiency of laboratories in the correct detection of Chlamydophila pneumoniae and Mycoplasma pneumoniae by nucleic acid amplification techniques (NAATs) (6 samples containing various concentrations (4.9-490 inclusion forming units (IFU)/ml) of C. pneumoniae, 5 samples containing various concentrations (20-5000 color-changing units (CCU)/ml) of M. pneumoniae and 2 samples negative for both). Seventy-nine laboratories from 18 countries participated in this EQA study. Sixty-four datasets were returned for C. pneumoniae (n=5 conventional commercial, n=10 conventional in-house, n=4 real-time commercial, n=43 real-time in-house, and n=2 SDA). Sixty-seven datasets were obtained for M. pneumoniae (n=5 conventional commercial, n=10 conventional in-house, n=4 real-time commercial, n=46 real-time in-house, and n=2 strand displacement amplification (SDA)). For the total panels, correct results per sample varied between 95.3% and 100% for C. pneumoniae and between 53.7% and 95.5% for M. pneumoniae. In general, commercial conventional NAATs showed possible sensitivity issues when compared to conventional in-house NAATs for both organisms. On the other hand, real-time commercial NAATs scored better than real-time in-house assays in terms of sensitivity for both organisms. For C. pneumoniae and M. pneumoniae, 0.8% and 2.2% true false-positive results and 1.9% and 2.0% false positives were reported in the samples spiked with the other organism. Analysis of the data for C. pneumoniae showed that the concentrations used were easily detectable by the vast majority of participants. The percentage of correct qualitative results for M. pneumoniae demonstrated that the concentrations included in this panel proved challenging for a number of participants.


Subject(s)
Bacteriological Techniques/standards , Chlamydophila Infections/diagnosis , Chlamydophila pneumoniae/isolation & purification , Molecular Diagnostic Techniques/standards , Mycoplasma pneumoniae/isolation & purification , Nucleic Acid Amplification Techniques/standards , Pneumonia, Mycoplasma/diagnosis , Chlamydophila pneumoniae/genetics , Humans , Mycoplasma pneumoniae/genetics , Pilot Projects , Quality Control
15.
J Clin Microbiol ; 48(7): 2536-40, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20147642

ABSTRACT

The purpose of this study was to evaluate the performance of laboratories for the detection and quantification of human herpesvirus 6 (HHV-6) by an external quality assessment (EQA) evaluation. The HHV-6 EQA panel consisted of eight samples containing various concentrations of HHV-6 type A (strain GS) or type B (strain Z29), two samples containing other herpesviruses (i.e., human cytomegalovirus [HCMV] and Epstein-Barr virus [EBV]), and two HHV-6-negative samples. Panel samples were prepared in human plasma, heat inactivated, and lyophilized. Panel distribution, data management, and analysis were coordinated by Quality Control for Molecular Diagnostics (QCMD), Glasgow, United Kingdom. Fifty-one laboratories participated and submitted 57 data sets. Eleven (19.3%) data sets were generated using conventional in-house assays, 11 (19.3%) data sets using commercial real-time PCR assays, and 35 (61.4%) data sets using in-house real-time PCR assays. The presence of HHV-6 DNA at viral loads exceeding 6,000 copies/ml was detected by all participants, and over 80% of the participants still reported correct qualitative results for the sample containing just over 200 copies/ml. The false-positivity rate was 1.8% for both the negative samples and the samples containing HCMV or EBV DNA. The majority (23/33; 69.7%) of quantitative data sets were generated using in-house real-time PCR assays. The standard deviations of the geometric means of the samples ranged from 0.5 to 0.7 log(10). The results of this first international EQA demonstrate encouraging analytical sensitivity for the detection of HHV-6-DNA in human plasma, although we observed extensive interlaboratory variation of quantitative HHV-6 DNA results. Standardization needs to be improved to allow further elucidation of the clinical significance of HHV-6 loads.


Subject(s)
Herpesvirus 6, Human , Molecular Diagnostic Techniques , Viral Load/methods , Virology/methods , DNA, Viral/analysis , DNA, Viral/isolation & purification , False Positive Reactions , Herpesvirus 6, Human/genetics , Herpesvirus 6, Human/isolation & purification , Humans , Laboratories/standards , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Polymerase Chain Reaction , Quality Control , Roseolovirus Infections/diagnosis
16.
Eur J Clin Microbiol Infect Dis ; 29(3): 295-300, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20082105

ABSTRACT

Two multicentre external quality assessments (EQA) for the molecular detection and genotyping of meticillin-resistant Staphylococcus aureus (MRSA) were arranged. Firstly, 11 samples containing various amounts of inactivated MRSA strains, meticillin-susceptible S. aureus (MSSA), meticillin-resistant coagulase-negative staphylococci (MRCoNS) or Escherichia coli were distributed to 82 laboratories. Samples containing 102 or 103 MRSA cells were correctly scored in only 16 and 46% of the datasets returned, respectively. Two of the used MSSA strains contained an SCCmec cassette lacking the mecA gene. There was a marked difference in the percentage of correct results for these two MSSA strains (37 and 39%) compared to the MSSA strain lacking the SCCmec cassette (88%). Secondly, a panel for MRSA genotyping, consisting of ten samples (two identical, three genetically related and five unique strains) was distributed to 19 laboratories. Seventy-three percent of the datasets recorded all samples correctly. Most pulsed-field gel electrophoresis (PFGE) protocols proved to be suboptimal, resulting in inferior resolution in the higher or lower fragment regions. The performance of molecular diagnostics for MRSA shows no significant changes since our first EQA in 2006. The first molecular typing results are encouraging. Both assessments indicate that programme expansion is required and that major performance discrepancies continue to exist.


Subject(s)
Methicillin-Resistant Staphylococcus aureus/genetics , Molecular Diagnostic Techniques/methods , Quality Assurance, Health Care/methods , Staphylococcal Infections/microbiology , Bacterial Proteins/genetics , DNA, Bacterial/analysis , Electrophoresis, Gel, Pulsed-Field/methods , Genotype , Humans , Penicillin-Binding Proteins , Staphylococcus aureus/genetics
17.
Clin Microbiol Infect ; 14(12): 1173-6, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19046164

ABSTRACT

The performance of nucleic acid amplification techniques for detecting respiratory syncytial virus (RSV) was evaluated in 25 laboratories across Europe by an external quality assessment study. In addition, factors related to the diagnostic performance of laboratories were explored. The results of this quality control study show that the performance of laboratories for RSV diagnosis in Europe is good, with an overall correct score of 88%. The type of assay (nested or real-time PCR vs. commercial tests) was identified as a significant factor (OR 8.39; 95% CI 1.91-36.78) in predicting a correct result.


Subject(s)
Health Services Research , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Respiratory Syncytial Virus Infections/diagnosis , Respiratory Syncytial Viruses/isolation & purification , Europe , Humans , Respiratory Syncytial Viruses/genetics
18.
J Clin Virol ; 43(4): 401-6, 2008 Dec.
Article in English | MEDLINE | ID: mdl-18977690

ABSTRACT

BACKGROUND: Drug-resistance testing plays a critical role in selection of optimal treatment regimens for HIV infected individuals. Laboratories performing testing must implement quality control measures including external quality assessment. OBJECTIVES: The ENVA7 Programme (2007) was organised by QCMD to assess the performance of laboratories testing for drug-resistance mutations in the HIV-1 Protease and Reverse Transcriptase genes. STUDY DESIGN: The ENVA7 panel consisted of 5 lyophilised plasma samples (HIV-1 subtypes B, C and F). The viruses harboured wild type or resistant genotypes at various positions of the PR and RT genes. All IAS-defined resistance-associated codons were scored in comparison to the consensus sequence for each sample using a scoring system developed to allow simple and standardised comparisons between laboratories and/or technologies. RESULTS: 111 laboratories from 44 countries participated of which 95 submitted 98 datasets. 36 datasets were generated using ViroSeq (Abbott), 27 using TruGene (Siemens) and 35 using in-house assays. CONCLUSIONS: All technologies successfully genotyped each of the panel samples, irrespective of the virus subtype. While the assays for genotypic HIV drug-resistance determination have evolved into reliable and technically capable procedures of generating high quality results, variation in the quality of results is still observed between laboratories.


Subject(s)
Drug Resistance, Viral , HIV-1/drug effects , HIV-1/genetics , Microbial Sensitivity Tests/methods , Microbial Sensitivity Tests/standards , Molecular Diagnostic Techniques/standards , Quality Assurance, Health Care , Humans
19.
J Clin Virol ; 42(2): 194-7, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18359662

ABSTRACT

BACKGROUND: We cannot predict when an influenza pandemic will occur or which variant of the virus will cause it. Little information is currently available on the ability of laboratories to detect and subtype influenza viruses including the avian influenza viruses. OBJECTIVES: To assess the ability of laboratories to detect and subtype influenza viruses. STUDY DESIGN: In 2006 QCMD distributed an External Quality Assessment panel for the molecular detection and haemagglutinin subtyping of influenza viruses to 87 laboratories in 34 countries Worldwide, which were given 6 weeks to return results. These data were analysed to assess laboratory performance. RESULTS: Influenza virus positive panel samples were correctly identified by 35-98% of laboratories. The correct haemagglutinin subtype was reported by 32-87% of laboratories that detected the virus: incorrect subtyping results included the reporting of avian influenza viruses as human strains and vice versa. Twelve laboratories reported false positives with some avian influenza viruses reported. CONCLUSIONS: These data suggest that improvements are needed in the molecular detection of influenza viruses and influenza virus A haemagglutinin subtyping. Only rapid and accurate identification of circulating pandemic influenza virus will ensure that the maximum time is available for intervention.


Subject(s)
Disease Outbreaks , Influenza A virus , Influenza B virus , Influenza, Human , Laboratories/standards , Animals , False Positive Reactions , Global Health , Hemagglutinin Glycoproteins, Influenza Virus/classification , Hemagglutinin Glycoproteins, Influenza Virus/genetics , Humans , Influenza A Virus, H3N2 Subtype/classification , Influenza A Virus, H3N2 Subtype/genetics , Influenza A Virus, H5N1 Subtype/classification , Influenza A Virus, H5N1 Subtype/genetics , Influenza A virus/classification , Influenza A virus/genetics , Influenza A virus/isolation & purification , Influenza B virus/classification , Influenza B virus/genetics , Influenza B virus/isolation & purification , Influenza, Human/diagnosis , Influenza, Human/epidemiology , Influenza, Human/virology , Quality Control , Reference Standards , Viral Load
20.
Phys Rev Lett ; 99(15): 154801, 2007 Oct 12.
Article in English | MEDLINE | ID: mdl-17995173

ABSTRACT

Acceleration of polarized protons in the energy range of 5 to 25 GeV is challenging. In a medium energy accelerator, the depolarizing spin resonances are strong enough to cause significant polarization loss but full Siberian snakes cause intolerably large orbit excursions and are also not feasible since straight sections usually are too short. Recently, two helical partial Siberian snakes with double pitch design have been installed in the Brookhaven Alternating Gradient Synchrotron (AGS). With a careful setup of optics at injection and along the energy ramp, this combination can eliminate the intrinsic and imperfection depolarizing resonances otherwise encountered during acceleration to maintain a high intensity polarized beam in medium energy synchrotrons. The observation of partial snake resonances of higher than second order will also be described.