Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Synchrotron Radiat ; 20(Pt 4): 531-40, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23765294

ABSTRACT

Nonlinear optical (NLO) instrumentation has been integrated with synchrotron X-ray diffraction (XRD) for combined single-platform analysis, initially targeting applications for automated crystal centering. Second-harmonic-generation microscopy and two-photon-excited ultraviolet fluorescence microscopy were evaluated for crystal detection and assessed by X-ray raster scanning. Two optical designs were constructed and characterized; one positioned downstream of the sample and one integrated into the upstream optical path of the diffractometer. Both instruments enabled protein crystal identification with integration times between 80 and 150 µs per pixel, representing a ∼10(3)-10(4)-fold reduction in the per-pixel exposure time relative to X-ray raster scanning. Quantitative centering and analysis of phenylalanine hydroxylase from Chromobacterium violaceum cPAH, Trichinella spiralis deubiquitinating enzyme TsUCH37, human κ-opioid receptor complex kOR-T4L produced in lipidic cubic phase (LCP), intimin prepared in LCP, and α-cellulose samples were performed by collecting multiple NLO images. The crystalline samples were characterized by single-crystal diffraction patterns, while α-cellulose was characterized by fiber diffraction. Good agreement was observed between the sample positions identified by NLO and XRD raster measurements for all samples studied.


Subject(s)
Microscopy, Fluorescence/methods , Synchrotrons , Crystallization , Humans , Proteins/chemistry , X-Ray Diffraction
2.
Anal Chem ; 85(12): 5720-6, 2013 Jun 18.
Article in English | MEDLINE | ID: mdl-23679898

ABSTRACT

Laser-induced acoustic desorption (LIAD) was recently coupled to atmospheric pressure chemical ionization (APCI) and shown to be of great utility for the analysis of a variety of thermally labile nonpolar analytes that are not amenable to ionization via electrospray ionization, such as nonvolatile hydrocarbons. Despite these advancements, LIAD still suffered from several limitations, including only being able to sample a small fraction of the analyte molecules deposited on a Ti foil for desorption, poor reproducibility, as well as limited laser power throughput to the backside of the foil. These limitations severely hinder the analysis of especially challenging analytes, such as asphaltenes. To address these issues, a novel high-throughput LIAD probe and an assembly for raster sampling of a LIAD foil were designed, constructed, and tested. The new probe design allows 98% of the initial laser power to be realized at the backside of the foil over the 25% achieved previously, thus improving reproducibility and allowing for the analysis of large nonvolatile analytes, including asphaltenes. The raster assembly provided a 5.7 fold increase in the surface area of a LIAD foil that could be sampled and improved reproducibility and sensitivity for LIAD experiments. The raster assembly can also improve throughput as foils containing multiple analytes can be prepared and analyzed.

3.
Acta Crystallogr D Biol Crystallogr ; 67(Pt 10): 839-46, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21931215

ABSTRACT

Two-photon excited ultraviolet fluorescence (TPE-UVF) microscopy is explored for sensitive protein-crystal detection as a complement to second-order nonlinear optical imaging of chiral crystals (SONICC). Like conventional ultraviolet fluorescence (UVF), TPE-UVF generates image contrast based on the intrinsic fluorescence of aromatic residues, generally producing higher fluorescence emission within crystals than the mother liquor by nature of the higher local protein concentration. However, TPE-UVF has several advantages over conventional UVF, including (i) insensitivity to optical scattering, allowing imaging in turbid matrices, (ii) direct compatibility with conventional optical plates and windows by using visible light for excitation, (iii) elimination of potentially damaging out-of-plane UV excitation, (iv) improved signal to noise through background reduction from out-of-plane excitation and (v) relatively simple integration into instrumentation developed for SONICC.


Subject(s)
Microscopy, Fluorescence/methods , Proteins/analysis , Proteins/chemistry , Crystallization , Muramidase/chemistry , Photons , Tryptophan/chemistry , Ultraviolet Rays
4.
J Am Soc Mass Spectrom ; 22(3): 531-8, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21472571

ABSTRACT

Laser-induced acoustic desorption (LIAD) was successfully coupled to a conventional atmospheric pressure chemical ionization (APCI) source in a commercial linear quadrupole ion trap mass spectrometer (LQIT). Model compounds representing a wide variety of different types, including basic nitrogen and oxygen compounds, aromatic and aliphatic compounds, as well as unsaturated and saturated hydrocarbons, were tested separately and as a mixture. These model compounds were successfully evaporated into the gas phase by using LIAD and then ionized by using APCI with different reagents. From the four APCI reagent systems tested, neat carbon disulfide provided the best results. The mixture of methanol and water produced primarily protonated molecules, as expected. However, only the most basic compounds yielded ions under these conditions. In sharp contrast, using APCI with either neat benzene or neat carbon disulfide as the reagent resulted in the ionization of all the analytes studied to predominantly yield stable molecular ions. Benzene yielded a larger fraction of protonated molecules than carbon disulfide, which is a disadvantage. A similar but minor amount of fragmentation was observed for these two reagents. When the experiment was performed without a liquid reagent (nitrogen gas was the reagent), more fragmentation was observed. Analysis of a known mixture as well as a petroleum cut was also carried out. In summary, the new experiment presented here allows the evaporation of thermally labile compounds, both polar and nonpolar, without dissociation or aggregation, and their ionization to predominantly form stable molecular ions.


Subject(s)
Mass Spectrometry/methods , Models, Chemical , Androsterone/chemistry , Carbon Disulfide/chemistry , Cholestanols/chemistry , Nitrogen/chemistry , Petroleum , Phenanthrolines/chemistry , Polycyclic Compounds/chemistry , Sensitivity and Specificity , Squalene/chemistry
5.
Analyst ; 136(4): 652-62, 2011 Feb 21.
Article in English | MEDLINE | ID: mdl-21076729

ABSTRACT

The electromagnetic field strength present within the focal volume of a pulsed laser is routinely high enough to produce reasonably efficient nonlinear summing and mixing of optical frequencies. The polarization-dependence of the outgoing beam is a sensitive function of the polarization state(s) of the incident beam(s) and the structure, orientation, and symmetry of the sample. Mining this information hinges on two elements: (1) accurate and precise polarization-dependent measurements, and (2) reliable modeling to relate the measured responses back to local structure and orientation. The central focus of this review is on the first step. Experimental strategies for precise and accurate nonlinear optical ellipsometry (NOE) polarization measurements are summarized for the most common and simplest case of second harmonic generation (SHG), or the frequency doubling of light, although extension to higher-order nonlinear optical interactions is straightforward in most cases.


Subject(s)
Nonlinear Dynamics , Optical Devices , Equipment Design , Humans , Linear Models , Microscopy , Optical Phenomena , Principal Component Analysis
6.
Talanta ; 68(4): 1366-70, 2006 Feb 15.
Article in English | MEDLINE | ID: mdl-18970473

ABSTRACT

A method for the determination of mercury via UV photoreduction has been investigated. Mercury vapor was generated by the reduction of mercury species in an acetic acid solution using UV radiation. Detection of the volatile mercury was accomplished by atomic absorption spectrometry. An optimized system was found to provide a detection limit (defined as the concentration giving a signal equal to three times the standard deviation of the blank) of 2.1mugL(-1) with a precision of 2.9% relative standard deviation (n=8) for a 500mugL(-1) mercury standard. The effect of various metal ions on the mercury signal was investigated and the method validated with a NRCC certified dogfish liver material (DOLT-3) using the method of standard additions. A reaction pathway is hypothesized for UV photoreduction.

SELECTION OF CITATIONS
SEARCH DETAIL
...