Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Cardiol ; 377: 9-16, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36640965

ABSTRACT

OBJECTIVE: The role of combined FFR/CFR measurements in decision-making on coronary revascularization remains unclear. DEFINE-FLOW prospectively assessed the relationship of FFR/CFR agreement with 2-year major adverse cardiac event (MACE) and target vessel failure (TVF) rates, and uniquely included core-laboratory analysis of all pressure and flow tracings. We aimed to document the impact of core-laboratory analysis on lesion classification, and the relationship between core-laboratory fractional flow reserve (FFR) and coronary flow reserve (CFR) values with clinical outcomes and angina burden during follow-up. METHODS: In 398 vessels (348 patients) considered for intervention, ≥1 coronary pressure/flow tracing was approved by the core-laboratory. Revascularization was performed only when both FFR(≤0.80) and CFR(<2.0) were abnormal, all others were treated medically. RESULTS: MACE was lowest for concordant normal FFR/CFR, but was not significantly different compared with either discordant group (low FFR/normal CFR: HR:1.63; 95%CI:0.61-4.40; P = 0.33; normal FFR/low CFR: HR:1.81; 95%CI:0.66-4.98; P = 0.25). Moreover, MACE did not differ between discordant groups treated medically and the concordant abnormal group undergoing revascularization (normal FFR/low CFR: HR:0.63; 95%CI:0.23-1.73;P = 0.37; normal FFR/low CFR: HR:0.70; 95%CI:0.22-2.21;P = 0.54). Similar findings applied to TVF. CONCLUSIONS: Patients with concordantly normal FFR/CFR have very low 2-year MACE and TVF rates. Throughout follow-up, there were no differences in event rates between patients in whom revascularization was deferred due to preserved CFR despite reduced FFR, and those in whom PCI was performed due to concordantly low FFR and CFR. These findings question the need for routine revascularization in vessels showing low FFR but preserved CFR. CLINICAL TRIAL REGISTRATION: http://ClinicalTrials.govNCT02328820.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Percutaneous Coronary Intervention , Humans , Coronary Angiography , Treatment Outcome , Coronary Artery Disease/diagnosis , Coronary Artery Disease/therapy
3.
Circ Cardiovasc Interv ; 9(12)2016 12.
Article in English | MEDLINE | ID: mdl-27899407

ABSTRACT

BACKGROUND: The Navvus pressure sensor-equipped microcatheter allows to measure functional stenosis severity over a work-horse guidewire and is used as a more feasible alternative to regular sensor-equipped wires. However, Navvus is larger in diameter than contemporary sensor-equipped guidewires and may, thereby, influence functional measurements. The present study evaluates the hemodynamic influence of the Navvus microcatheter. METHODS AND RESULTS: In patients with intermediate coronary stenosis, coronary pressure and flow velocity were measured using a dual sensor-equipped guidewire before and after introduction of Navvus. Patients were randomized to microcatheter-first or guidewire-first measurement. The primary end point was the difference in hyperemic stenosis resistance index between measurements before and after introduction of Navvus. Measurements were completed in 28 patients (28 stenoses). Mean hyperemic stenosis resistance was 0.37±0.19 Hg/cm/s for wire-only assessment and 0.48±0.26 Hg/cm/s after Navvus introduction (P<0.001). Bland-Altman analysis documented a mean bias of +0.11 Hg/cm/s (limits of agreement: -0.13 to 0.36), proportional to mean hyperemic stenosis resistance (Spearman ρ =0.61; P=0.001). Passing-Bablok analysis revealed absence of a constant difference but significant proportional difference between the methods. Mean fractional flow reserve was 0.86±0.06 for wire-only assessment and 0.82±0.07 after Navvus introduction (P<0.001). Bland-Altman analysis documented a mean bias of -0.033 (limits of agreement: -0.09 to 0.03), proportional to mean fractional flow reserve (Spearman ρ =0.40; P=0.036). Passing-Bablok analysis revealed significant constant and proportional differences between methods. Similar results were documented for resting indices of stenosis severity. CONCLUSIONS: Introduction of the Navvus microcatheter leads to clinically relevant stenosis severity overestimation in intermediate stenosis.


Subject(s)
Cardiac Catheterization/instrumentation , Cardiac Catheters , Coronary Circulation , Coronary Stenosis/diagnosis , Coronary Vessels/physiopathology , Hemodynamics , Transducers, Pressure , Aged , Arterial Pressure , Blood Flow Velocity , Coronary Angiography , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/physiopathology , Coronary Vessels/diagnostic imaging , Equipment Design , Female , Humans , Male , Middle Aged , Miniaturization , Predictive Value of Tests , Prognosis , Reproducibility of Results , Severity of Illness Index
SELECTION OF CITATIONS
SEARCH DETAIL
...