Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Environ Health Res ; : 1-13, 2022 Oct 06.
Article in English | MEDLINE | ID: mdl-36201749

ABSTRACT

Owing to the importance of drug delivery, the synthesis of advanced nanomaterials for targeted drug delivery plays a considerable role in medical treatment. One of the most prominent nanomaterials is PIL, which is used as controlled anticancer drug delivery and significantly improves the half-life and antitumor effect. In this study, a stable and effective drug carrier containing silver nanoparticles was reported for the drug delivery with an antimicrobial effect, and the capability of the drug carrier . PILP was synthesized by radical polymerization, and silver nanoparticles were anchored into PIL voids by in-situ reduction, which developed the adsorption antimicrobial effect and capability of the drug carrier. The synthesized nanocomposite was characterized. The Ag-PILP nanocomposite showed antibacterial activityagainst both E. coli and S. aureus with a MIC of 256 µg/mL, and bactericidal activity against E. coli and S. aureus strains with a MBC of 256 and 512 µg/mL, respectively.

2.
J Sep Sci ; 39(24): 4835-4840, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27790835

ABSTRACT

We describe the synthesis of a layered zinc hydroxide-dodecyl sulfate organic-inorganic hybrid nanocomposite as a new solid-phase microextraction fiber. The fiber coating can be prepared easily in a short time and the reaction is at room temperature; it is mechanically stable and exhibits relatively high thermal stability. The synthesized layered zinc hydroxide-dodecyl sulfate nanocomposite was successfully prepared and immobilized on a stainless steel wire and evaluated for the extraction of aromatic compounds from aqueous sample solutions in combination with gas chromatography and mass spectrometry. The method yields good results for some validation parameters. Under optimum conditions (extraction time: 15 min, extraction temperature: 50°C, desorption time: 1 min, desorption temperature: 250°C, salt concentration: 0.5 g/mL), the limit of detection and dynamic linear range were 0.69-3.2 ng/L and 10-500 ng/L, respectively. The method was applied to the analyses of benzene, toluene, ethylbenzene, and o-, p-, and m-xylenes in two real water samples collected from the Aji river and Mehran river, Tabriz, Iran. Under optimum conditions, the repeatability and reproducibility for one fiber (n = 3), expressed as the relative standard deviation, was 3.2-7.3% and 4.2-11.2% respectively. The fibers are thermally stable and yield better recoveries than conventional methods of analysis.

SELECTION OF CITATIONS
SEARCH DETAIL
...