Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
EuroIntervention ; 11(8): 926-34, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25169589

ABSTRACT

AIMS: Treatment of bare metal in-stent restenosis with the paclitaxel-coated balloon catheter based on the PACCOCATH® technology has yielded superior six-month angiographic and one-year clinical results compared to a paclitaxel-eluting stent. The three-year clinical follow-up is presented. METHODS AND RESULTS: One hundred and thirty-one patients with coronary bare metal in-stent restenosis (>70%, length: <22 mm, vessel diameter: 2.5-3.5 mm) were randomly treated with the paclitaxel-coated balloon (DCB) (3 µg/mm²) or a paclitaxel-eluting stent (DES). Clinical follow-up information was requested from the patients and from their physicians. Quantitative angiographic and demographic baseline data were statistically not different between the groups. Per intention-to-treat analysis at 12 months, the lesion-related rates of major adverse cardiac events were 7.6% and 16.9% (p=0.11) while at 36 months the respective numbers were 9.1% and 18.5% (p=0.14). These differences were primarily due to reduced target lesion revascularisation (TLR) in DCB 4/66 (6.2%) compared to DES patients 10/65 (15.4%) (p=0.10). From 12 to 36 months, 1/65 (1.5%) DCB patients experienced a myocardial infarction while neither TLR nor death occurred in any study patient in either group during that period. CONCLUSIONS: The six-month superiority of the paclitaxel-coated balloon compared to the paclitaxel-eluting stent in the treatment of bare metal coronary in-stent restenosis persisted throughout the three-year clinical follow-up period indicating stability of the lesions treated. (ClinicalTrials.gov Identifier: NCT00393315).


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Coronary Artery Disease/therapy , Coronary Restenosis/therapy , Drug-Eluting Stents , Paclitaxel/administration & dosage , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Stents , Vascular Access Devices , Aged , Angioplasty, Balloon, Coronary/adverse effects , Coronary Angiography , Coronary Artery Disease/diagnosis , Coronary Restenosis/diagnosis , Coronary Restenosis/etiology , Disease-Free Survival , Female , Germany , Humans , Intention to Treat Analysis , Kaplan-Meier Estimate , Male , Metals , Middle Aged , Myocardial Infarction/etiology , Platelet Aggregation Inhibitors/therapeutic use , Prosthesis Design , Retreatment , Time Factors , Treatment Outcome
2.
Circulation ; 119(23): 2986-94, 2009 Jun 16.
Article in English | MEDLINE | ID: mdl-19487593

ABSTRACT

BACKGROUND: Treatment of in-stent restenosis with paclitaxel-coated balloon catheter as compared with plain balloon angioplasty has shown surprisingly low late lumen loss at 6 months and fewer major adverse cardiac events up to 2 years. We compared the efficacy and safety of a paclitaxel-coated balloon with a paclitaxel-eluting stent as the current standard of care. METHODS AND RESULTS: One hundred thirty-one patients with coronary in-stent restenosis were randomly assigned to treatment by a paclitaxel-coated balloon (3 microg/mm2) or a paclitaxel-eluting stent. The main inclusion criteria encompassed diameter stenosis of > or =70% and < or =22 mm in length, with a vessel diameter of 2.5 to 3.5 mm. The primary end point was angiographic in-segment late lumen loss. Quantitative coronary angiography revealed no differences in baseline parameters. At 6 months follow-up, in-segment late lumen loss was 0.38+/-0.61 mm in the drug-eluting stent group versus 0.17+/-0.42 mm (P=0.03) in the drug-coated balloon group, resulting in a binary restenosis rate of 12 of 59 (20%) versus 4 of 57 (7%; P=0.06). At 12 months, the rate of major adverse cardiac events were 22% and 9%, respectively (P=0.08). This difference was primarily due to the need for target lesion revascularization in 4 patients (6%) in the coated-balloon group, compared with 10 patients (15%) in the stent group (P=0.15). CONCLUSIONS: Treatment of coronary in-stent restenosis with the paclitaxel-coated balloon was at least as efficacious and as well tolerated as the paclitaxel-eluting stent. For the treatment of in-stent restenosis, inhibition of re-restenosis does not require a second stent implantation.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Restenosis/therapy , Drug-Eluting Stents , Paclitaxel/administration & dosage , Tubulin Modulators/administration & dosage , Aged , Angioplasty, Balloon, Coronary/adverse effects , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/prevention & control , Drug-Eluting Stents/adverse effects , Female , Follow-Up Studies , Humans , Male , Middle Aged , Platelet Aggregation Inhibitors/therapeutic use
3.
J Invasive Cardiol ; 15(10): 557-60, 2003 Oct.
Article in English | MEDLINE | ID: mdl-14519886

ABSTRACT

UNLABELLED: Percutaneous interventions of degenerated saphenous vein grafts (SVG) are associated with high rates of distal embolic events and in-stent restenosis. A novel ePTFE-covered stent graft has been developed to improve outcomes for these difficult lesions. The stent graft has been treated with a 15-amino acid, cell adhesion peptide (P-15) to promote endothelialization on the inner surface post-implantation. Patients with de novo lesions in SVGs were treated with a peptide-coated ePTFE stent graft. Follow-up data was collected at 30 days, 3 and 6 months. An angiographic core lab analyzed an angiographic follow-up at 6 months. RESULTS: Procedural success was achieved in all cases. No device-related major adverse cardiac events occurred in-hospital, at 30 days, or at 3 months, despite the lack of distal protection. Six-month restenosis rates were 21%, and were comparable to similar devices. CONCLUSIONS: The peptide-treated stent graft appears to be a safe and effective treatment for SVG lesions, and has the potential to reduce complications without the use of adjunct distal protection in this patient population.


Subject(s)
Coated Materials, Biocompatible/therapeutic use , Collagen/therapeutic use , Coronary Artery Bypass/adverse effects , Graft Occlusion, Vascular/therapy , Peptide Fragments/therapeutic use , Polytetrafluoroethylene/therapeutic use , Saphenous Vein/pathology , Vascular Surgical Procedures/instrumentation , Aged , Blood Vessel Prosthesis , Coronary Artery Bypass/methods , Female , Humans , Male , Middle Aged , Prospective Studies , Saphenous Vein/transplantation , Stents
SELECTION OF CITATIONS
SEARCH DETAIL
...