Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 51
Filter
1.
Article in English | MEDLINE | ID: mdl-38625830

ABSTRACT

AIMS: In this study, we investigated a cohort of unselected patients with various indications for an implantable cardiac monitor (ICM). Our main objectives were to determine the incidence of arrhythmic diagnoses, both anticipated and incidental in relation to the ICM indication, and to assess their clinical relevance. METHODS: We examined remote monitoring transmissions from patients with an ICM at four Italian sites to identify occurrences of cardiac arrhythmias. Concurrently, we collected data on medical actions taken in response to arrhythmic findings. RESULTS: The study included 119 patients, with a median follow-up period of 371 days. ICM indications were syncope/presyncope (46.2%), atrial fibrillation management (31.1%), and cryptogenic stroke (22.7%). In the atrial fibrillation management group, atrial fibrillation was the most common finding, with an incidence of 36% [95% confidence interval (CI) 22-55%] at 18 months. Rates of atrial fibrillation were not significantly different between patients with cryptogenic stroke and syncope/presyncope [17% (95% CI 7-40%) vs. 8% (95% CI 3-19%), P = 0.229].For patients with cryptogenic stroke, the incidence of asystole and bradyarrhythmias at 18 months was 23% (95% CI 11-45%) and 42% (95% CI 24-65%), respectively, similar to estimates obtained for patients implanted for syncope/presyncope (P = 0.277 vs. P = 0.836).Overall, 30 patients (25.2%) required medical intervention following ICM-detected arrhythmias, predominantly involving atrial fibrillation ablation (10.9%) and medication therapy changes (10.1%). CONCLUSION: In a real-life population with heterogeneous insertion indications, approximately 25% of patients received ICM-guided medical interventions within a short timeframe, including treatments for incidental findings. Common incidental arrhythmic diagnoses were bradyarrhythmias in patients with cryptogenic stroke and atrial fibrillation in patients with unexplained syncope.

3.
Patient Prefer Adherence ; 17: 2579-2594, 2023.
Article in English | MEDLINE | ID: mdl-37881621

ABSTRACT

Purpose: To determine whether a nurse-led care model with telemonitoring in primary care for patients with stable heart failure and their caregivers is feasible and acceptable. Patients and Methods: A mixed-methods feasibility study was conducted. Patients with stable heart failure and their caregivers were consecutively enrolled from March 2021 to April 2022. Participants were managed by nurses in a community health center through education and monitoring with a mobile app. The outcomes were feasibility outcomes, self-care outcomes, and qualitative acceptability and satisfaction. Quantitative and qualitative outcomes were linked to understanding how the model of care might benefit patients. Results: Twenty-six patients and nine of their caregivers were enrolled. Ten participants used the mobile app. Nineteen patients and eight caregivers were interviewed. Participants who improved their self-care appreciated the help in finding coping strategies, being close to the clinic, and feeling cared for. Participants with fewer improvements in self-care perceived the model of care as useless and were far from the centre. Participants decided to use the app mainly for usefulness prevision, and most of them were satisfied. Conclusion: The model of care was not successful in recruiting patients, and adjustments are needed to improve the recruitment strategy and to engage people who perceive the model of care as not useful or unable to use the app.

4.
Int J Cardiol ; 389: 131199, 2023 10 15.
Article in English | MEDLINE | ID: mdl-37481001

ABSTRACT

BACKGROUND: Remote Monitoring (RM) is recognized for its ability to enhance the clinical management of patients with implantable cardiac monitor (ICM). This study aims to provide a comprehensive description of the arrhythmic episodes transmitted by a daily and automatic RM system from a cohort of ICM patients. METHODS: The study retrospectively analyzed daily transmissions from consecutive patients who had been implanted with a long-sensing vector ICM (BIOMONITOR III/IIIm) at four sites. All transmitted arrhythmic recordings were evaluated to determine whether they were true positive episodes or false positives (FP). RESULTS: A total of 14,136 episodes were transmitted from 119 patients (74.8% male, median age 62 years old) during a median follow-up of 371 days. The rate of arrhythmic episodes was 14.2 per patient-year (interquartile range: 1.8-126), with 97 patients (81.5%) experiencing at least one ICM activation. Fifty-five percent of episodes were identified as FP, and 67 patients (56.3%) had at least one inappropriate activation. The FP rate was 1.4 per patient-year (0-40). The best per-episode predictive positive values were observed for bradycardia and atrial fibrillation (0.595 and 0.553, respectively). Notably, the implementation of an algorithm designed to minimize false detections significantly reduced the prevalence of atrial fibrillation FP episodes (17.6% vs. 43.5%, p = 0.008). CONCLUSION: Daily and automatic RM appears to be a reliable tool for the comprehensive remote management of ICM patients. However, the number of arrhythmic episodes requiring review is high, and further improvements are needed to reduce FP and facilitate accurate interpretation of transmissions.


Subject(s)
Atrial Fibrillation , Defibrillators, Implantable , Humans , Male , Middle Aged , Female , Retrospective Studies , Electrocardiography, Ambulatory , Electrocardiography , Algorithms
5.
Heart Rhythm ; 20(2): 233-240, 2023 02.
Article in English | MEDLINE | ID: mdl-37283031

ABSTRACT

BACKGROUND: Elevated resting heart rate is a risk factor for cardiovascular events. OBJECTIVE: The purpose of this study was to investigate the clinical significance of nocturnal heart rate (nHR) and 24-hour mean heart rate (24h-HR) obtained by continuous remote monitoring (RM) of implantable devices. METHODS: We analyzed daily-sampled trends of nHR, 24h-HR, and physical activity in patients on ß-blocker therapy for chronic heart failure and with implantable cardioverter-defibrillators or cardiac resynchronization therapy defibrillators (CRT-Ds). Patients were grouped by average nHR and 24h-HR quartile during follow-up to estimate the respective incidence of nonarrhythmic death and device-treated ventricular tachycardia/fibrillation (VT/VF). RESULTS: The study cohort included 1330 patients (median age 69 years [interquartile range 61-77 years]; 41% [n = 550] with CRT-D; median follow-up 25 months [interquartile range 13-42 months]). Compared with patients in the lowest nHR quartile (≤57 beats/min) group, patients in the highest quartile group (>65 beats/min) had an increased risk of nonarrhythmic death (adjusted hazard ratio [AHR] 2.25; 95% confidence interval [CI] 1.13-4.50; P = .021) and VT/VF (AHR 1.98; 95% CI 1.40-2.79; P < .001) and were characterized by the lowest level of physical activity (P ≤ .0004 vs every other nHR quartiles). The highest 24h-HR quartile group (>75 beats/min) showed an increased risk of VT/VF (AHR 2.13; 95% CI 1.52-2.99; P < .001) and a weaker though significant association with nonarrhythmic mortality (AHR 1.80; 95% CI 1.00-3.22; P = .05) as compared with the lowest 24h-HR quartile group (≤65 beats/min). CONCLUSION: In remotely monitored patients with implantable cardioverter-defibrillator/CRT-D on ß-blocker therapy for heart failure, elevated heart rates (nHR >65 beats/min and 24h-HR >75 beats/min) were associated with increased mortality and VT/VF risk. nHR showed a stronger association than 24h-HR with worst prognosis and lowest physical activity.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Tachycardia, Ventricular , Ventricular Dysfunction, Left , Humans , Middle Aged , Aged , Heart Rate , Prognosis , Stroke Volume , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/therapy , Ventricular Fibrillation/therapy , Arrhythmias, Cardiac/therapy , Risk Factors , Heart Failure/complications , Heart Failure/diagnosis , Heart Failure/therapy , Cardiac Resynchronization Therapy/adverse effects , Defibrillators, Implantable/adverse effects , Ventricular Dysfunction, Left/complications
6.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-36974970

ABSTRACT

AIMS: In patients with prolonged atrioventricular (AV) conduction and pacemaker (PM) indication due to sinus node disease (SND) or intermittent AV-block who do not need continuous ventricular pacing (VP), it may be difficult to determine which strategy to adopt. Currently, the standard of care is to minimize unnecessary VP by specific VP avoidance (VPA) algorithms. The superiority of this strategy over standard DDD or DDD rate-responsive (DDD/DDDR) in improving clinical outcomes is controversial, probably owing to the prolongation of the atrialventricular conduction (PR interval) caused by the algorithms. Conduction system pacing (CSP) may offer the most physiological-VP approach, providing appropriate AV conduction and preventing pacing-induced dyssynchrony. METHODS AND RESULTS: PhysioVP-AF is a prospective, controlled, randomized, single-blind trial designed to determine whether atrial-synchronized conduction system pacing (DDD-CSP) is superior to standard DDD-VPA pacing in terms of 3-year reduction of persistent-AF occurrence. Cardiovascular hospitalization, quality-of-life, and safety will be evaluated. Patients with indication for permanent DDD pacing for SND or intermittent AV-block and prolonged AV conduction (PR interval > 180 ms) will be randomized (1:1 ratio) to DDD-VPA (VPA-algorithms ON, septal/apex position) or to DDD-CSP (His bundle or left bundle branch area pacing, AV-delay setting to control PR interval, VPA-algorithms OFF). Approximately 400 patients will be randomized in 24 months in 13 Italian centres. CONCLUSION: The PhysioVP-AF study will provide an essential contribution to patient management with prolonged AV conduction and PM indication for sinus nodal disease or paroxysmal 2nd-degree AV-block by determining whether CSP combined with a controlled PR interval is superior to standard management that minimizes unnecessary VP in terms of reducing clinical outcomes.


Subject(s)
Atrial Fibrillation , Atrioventricular Block , Pacemaker, Artificial , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Prospective Studies , Single-Blind Method , Sick Sinus Syndrome/complications , Sick Sinus Syndrome/diagnosis , Sick Sinus Syndrome/therapy
7.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Article in English | MEDLINE | ID: mdl-36709469

ABSTRACT

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Subject(s)
Arrhythmias, Cardiac , Tachycardia, Ventricular , Humans , Arrhythmias, Cardiac/therapy , Electric Impedance , Retrospective Studies , Ventricular Fibrillation , Defibrillators, Implantable
8.
Neurol Sci ; 44(3): 979-988, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36383264

ABSTRACT

BACKGROUND: Subclinical atrial fibrillation (SCAF) may represent a cause of embolic stroke of undetermined source (ESUS) and its detection has important implications for secondary prevention with anticoagulation. Indications to implantable cardiac monitors (ICM) include SCAF detection. The aims of this study were to (1) evaluate the frequency of ICM-detected SCAF; (2) determine predictors of SCAF; and (3) identify patients who would benefit most from ICM implantation. METHODS: Between February 2017 and November 2020, all consecutive patients referred for ICM implantation after a diagnosis of ESUS and without previous history of atrial fibrillation or atrial flutter were included in this study. SCAF was diagnosed if the ICM electrogram demonstrated an episode of irregularly irregular rhythm without distinct P waves lasting > 2 min. RESULTS: We enrolled 109 patients (age 66, SD = 13 years; 36% females). During a median follow-up of 19.2 (IQR 11.0-27.5) months, SCAF episodes were detected in 36 (33%) patients. Only abnormal P wave terminal force in lead V1, left atrial end-systolic indexed volume > 34 ml/m2, and BMI > 25 kg/m2 were independently associated with an increased risk of SCAF (HR 2.44, 95% CI 1.14-5.21, p = 0.021; HR 2.39, 95% CI 1.11-5.13, p = 0.026; and HR 2.64, 95% CI 1.06-6.49, p = 0.036 respectively). The ROC curve showed that the presence of all three parameters had the best accuracy (74%) to predict SCAF detection (sensitivity 39%, specificity 91%). CONCLUSION: A multiparametric evaluation has the best accuracy to predict SCAF in ESUS patients and may help identifying those who would benefit most from ICM.


Subject(s)
Atrial Fibrillation , Embolic Stroke , Stroke , Female , Humans , Aged , Male , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Embolic Stroke/complications , Risk Factors , Electrocardiography/adverse effects , Stroke/complications , Stroke/diagnosis
9.
Eur J Cardiovasc Nurs ; 22(8): 773-779, 2023 Dec 14.
Article in English | MEDLINE | ID: mdl-36346102

ABSTRACT

AIMS: Implantable cardiac monitors (ICMs) can generate false-positive (FP) alerts. Although these devices have an extended programmability, there are no recommendations on their optimization to reduce not-relevant activations.We tested a strategic programming optimization guide based on the type of FP and investigated the safety and feasibility of the nurse-led insertion of ICMs with a long-sensing vector. METHODS AND RESULTS: Consecutive patients implanted by trained nurses with long-sensing vector ICM were enrolled in a 1-month observational stage (Phase A). Patients who had ≥10 FP episodes underwent ICM reprogramming based on the predefined guide and were followed for an additional month (Phase B). A total of 78 patients had successful ICM insertion by nurses with a mean R wave amplitude of 0.96 ± 0.43 mV and an 86% P wave visibility. Only one patient reported a significant device-related issue, and nurse-delivered ICM was generally well accepted by the patients. During Phase A, 11 patients (14%) generated most of FP (3,627/3,849; 94%) and underwent ICM reprogramming. In the following month (Phase B), five patients (45%) were free from FP and six (55%) transmitted 57 FP alerts (98% reduction compared with Phase A). The median number of FP per patient was significantly reduced after reprogramming [195 (interquartile range, 50-311) vs. one (0-10), P = 0.0002]. CONCLUSION: A strategic reprogramming of ICM in those patients with a high FP alert burden reduces the volume of erroneous activations with potential benefits for the remote monitoring service. No concerns were raised regarding nurse-led insertion of ICMs with a long-sensing vector.


Subject(s)
Atrial Fibrillation , Electrocardiography, Ambulatory , Humans , Arrhythmias, Cardiac , Electrocardiography , Electrocardiography, Ambulatory/methods , Nurse's Role , Prostheses and Implants , Feasibility Studies
10.
JACC Clin Electrophysiol ; 8(12): 1553-1562, 2022 12.
Article in English | MEDLINE | ID: mdl-36543505

ABSTRACT

BACKGROUND: Causes of sex differences in incidence of sustained ventricular arrhythmias (SVAs) are poorly understood. OBJECTIVES: This study aims to investigate sex-specific risk of SVAs and device therapies by balancing sex groups in relation to several baseline characteristics with the propensity score (PS). METHODS: We used a large remote monitoring dataset from implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds). Study endpoints were time to the first appropriate SVA, time to the first device therapy for SVA, and time to the first ICD shock. Results were compared between females and a PS-matched male subgroup. RESULTS: In a cohort of 2,532 patients with an ICD or CRT-D (median age, 70 years), 488 patients (19.3%) were women. After selecting 488 men PS-matched for 19 variables relative to baseline demographics, implant indications, principal comorbidities, and concomitant therapy, yet the SVA rate at the 2.1-year median follow-up was significantly lower in women than in man (adjusted HR: 0.65; 95% CI: 0.51-0.81; P < 0.001). Women also showed a reduced risk of any device therapy (HR: 0.59; 95% CI: 0.45-0.76; P < 0.001) and shocks (HR: 0.66; 95% CI: 0.47-0.94; P = 0.021). Differences in sex-specific SVA risk profile were not confirmed in CRT-D patients (HR: 0.78; 95% CI: 0.55-1.09; P = 0.14) nor in those with an ejection fraction <30% (HR: 0.80; 95% CI: 0.52-1.23; P = 0.31). CONCLUSIONS: After matching demographics, indications, principal comorbidities, and concomitant therapy, women still exhibited a lower SVA risk profile than men, except in the subgroups of CRT-D or/and ejection fraction <30%.


Subject(s)
Defibrillators, Implantable , Humans , Male , Female , Aged , Defibrillators, Implantable/adverse effects , Propensity Score , Treatment Outcome , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/therapy , Electric Countershock
11.
Assist Inferm Ric ; 41(2): 74-86, 2022.
Article in Italian | MEDLINE | ID: mdl-35856306

ABSTRACT

. The TeMP_cardio Model for the district management of heart failure patients: a feasibility study for the implementation of the family nurse. INTRODUCTION: The need to enhance primary health nursing care and chronic disease management requires the development of complex and feasible models in local contexts. AIM: To test the feasibility of a complex care model, based on the introduction of the family and community nurse for patients with stable heart failure and their caregivers. METHODS: A pre-post six-month feasibility study was conducted in 2021-2022 in the Autonomous Province of Trento. Patients with stable heart failure able to access services were taken in charge with a multidisciplinary model, with the nurse as care manager, and technological and telemonitoring support. RESULTS: 26 patients out of 137 were included and nine of their caregivers. Ten participants accepted to use the mobile app. Twenty-three patients and seven caregivers completed the study, and the app was used regularly by five participants. Self-care skills improved in patients, mostly in self-monitoring, less in caregivers. One access to the emergency department for heart failure exacerbation was detected. CONCLUSIONS: The model was evaluated feasible to retain patients, with the need to build effective strategies for the recruitment, and the regular use of telemonitoring tools.


Subject(s)
Heart Failure , Mobile Applications , Caregivers , Chronic Disease , Feasibility Studies , Heart Failure/therapy , Humans
12.
Med Biol Eng Comput ; 60(8): 2307-2319, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35729476

ABSTRACT

This work dealt with the assessment of a computational tool to estimate the electrical activation in the left ventricle focusing on the latest electrically activated segment (LEAS) in patients with left bundle branch block and possible myocardial fibrosis. We considered the Eikonal-diffusion equation and to recover the electrical activation maps in the myocardium. The model was calibrated by using activation times acquired in the coronary sinus (CS) branches or in the CS solely with an electroanatomic mapping system (EAMS) during cardiac resynchronization therapy (CRT). We applied our computational tool to ten patients founding an excellent accordance with EAMS measures; in particular, the error for LEAS location was less than 4 mm. We also calibrated our model using only information in the CS, still obtaining an excellent agreement with the measured LEAS. The proposed tool was able to accurately reproduce the electrical activation maps and in particular LEAS location in the CS branches, with an almost real-time computational effort, regardless of the presence of myocardial fibrosis, even when information only at CS was used to calibrate the model. This could be useful in the clinical practice since LEAS is often used as a target site for the left lead placement during CRT. Overall picture of the computational pipeline for the estimation of LEAS.


Subject(s)
Cardiac Resynchronization Therapy , Coronary Sinus , Heart Failure , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy Devices , Fibrosis , Humans , Treatment Outcome
13.
Z Gesundh Wiss ; 30(1): 77-92, 2022.
Article in English | MEDLINE | ID: mdl-34150467

ABSTRACT

AIM: In response to the SARS-CoV-2 emergency, the Competence Centre on digital health 'TrentinoSalute4.0' has developed TreC_Televisita, a tele visit solution that meets the needs of the Trentino healthcare system and maintains high-quality patient-doctor interactions while respecting social distancing. This paper highlights how 'TreC_Televisita' was integrated into the Trentino healthcare system and its potential to become a structural and durable solution for the future local healthcare service provisioning. SUBJECT AND METHODS: This paper presents the multifactorial context that TreC_Televisita has faced for its implementation and the strategies adopted for its structural integration into the healthcare system. The analysis focuses on the main issues faced for the integration of the tele visits (e.g. privacy, payments) and how the context of TrentinoSalute4.0 permitted responding quickly to its implementation during the pandemic. It also describes how TreC_Televisita fits into the healthcare continuum from the organisational and technological standpoint, the end-user perspective and the barriers that could hamper the solution scalability. RESULTS: TreC_Televisita has demonstrated to be a technological solution that can be contextualised for different clinical domains beyond SARS-CoV-2. Moreover, it has shown its potential to scale up the solution beyond the COVID-19 emergency to the whole healthcare provisioning system in the long term. CONCLUSION: Being a positive experience in the first months of its implementation, the long-term goal is to transform TreC_Televisita into a structural pillar of the Trentino healthcare system, setting the bases for a sustainable, win-win situation for all the stakeholders involved in healthcare service provisioning.

14.
Int J Cardiol Heart Vasc ; 36: 100879, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34604501

ABSTRACT

Athletes with asymptomatic ventricular pre-excitation (VP) should undergo electrophysiological study for risk stratification. We aimed to evaluate the feasibility, efficacy, safety and tolerability of an electrophysiological study using a percutaneous antecubital vein access and without the use of X-ray (ESnoXr). Methods: We collected data from all young athletes < 18 year-old with AVP, who underwent ESnoXr from January 2000 to September 2020 for evaluation of accessory pathway refractoriness and arrhythmia inducibility using an antecubital percutaneous venous access. Endocavitary signals were used to advance the catheter in the right atrium and ventricle. Results: We included 63 consecutive young athletes (mean age 14.6 ± 1.9 years, 46% male). Feasibility of the ESnoXr technique was 87% while in 13% fluoroscopy and/or a femoral approach were needed. Specifically, fluoroscopy was used in 7 cases to position the catheter inside the heart cavities with an average exposure of 43 ± 38 s while in 2 femoral venous access was needed. The mean procedural time was 35 ± 11 min. The exam was diagnostic in all patients, there were no procedural complications and tolerability was excellent. 53% of the patients had an accessory pathway with high refractoriness and no inducible atrio-ventricular reentry tachycardia: this subgroup was considered eligible to competitive sports and no event was observed during long-term follow-up (13.6 ± 5.2 years) without drug use. The others underwent catheter ablation. Conclusion. ESnoXr has been shown to be a feasible, effective, safe and well-tolerated procedure for the assessment of arrhythmic risk in a population of young athletes with asymptomatic VP.

15.
J Clin Med ; 10(18)2021 Sep 10.
Article in English | MEDLINE | ID: mdl-34575197

ABSTRACT

The COVID-19 pandemic has had a profound impact on the organisation of health care in Italy, with an acceleration in the development of telemedicine. To assess the impact of the COVID-19 pandemic on the spread of remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) in Italy, a survey addressed to cardiologists operating in all Italian CIED-implanting centres was launched. A total of 127 cardiologists from 116 Italian arrhythmia centres took part in the survey, 41.0% of all 283 CIED-implanting centres operating in Italy in 2019. All participating centres declared to use RM of CIEDs. COVID-19 pandemic resulted in an increase in the use of RM in 83 (71.6%) participating centres. In a temporal perspective, an increase in the median number of patients per centre followed up by RM was found from 2012 to 2017, followed by an exponential increase from 2017 to 2020. In 36 participating centres (31.0%) a telehealth visits service was activated as a replacement for in-person outpatient visits (in patients with or without CIED) during the COVID-19 pandemic. COVID-19 pandemic has caused an acceleration in the use of RM of CIEDs and in the use of telemedicine in the clinical practice of cardiology.

16.
Eur J Intern Med ; 92: 86-93, 2021 10.
Article in English | MEDLINE | ID: mdl-34247889

ABSTRACT

BACKGROUND: Implantable cardiac monitor (ICM) revealed subclinical atrial fibrillation (SCAF) in up to 30% of cryptogenic stroke (CS) patients in randomized trials. However, real world data are limited. OBJECTIVES: We investigated SCAF occurrence, treatments, clinical outcomes and predictors of SCAF in a multicenter real-world population subjected to ICM after CS. METHODS: From September 2016 to November 2019, 20 Italian centers collected data of consecutive patients receiving ICM after CS and followed with remote and outpatient follow-up according to clinical practice. All device-detected AF events were confirmed by the cardiologist to diagnose SCAF. RESULTS: ICM was implanted in 334 CS patients (mean age±SD 67.4±11.5 years, 129 (38.6%) females, 242 (76.1%) with CHA2DS2-VASC score≥4). During a follow-up of 23.6 (IQR 14.6-31.5) months, SCAF was diagnosed in 92 (27.5%) patients. First episode was asymptomatic in 81 (88.1%). SCAF daily burden ≥5 minutes was 22.0%, 24.1% and 31.5% at 6, 12, and 24 months after ICM implantation. Median time to first day with AF was 60 (IQR 18-140) days. Female gender, age>69 years, PR interval>160 ms and cortical-subcortical infarct type at enrolment were independently associated with an increased risk of SCAF. CONCLUSIONS: In a real-world population, ICM detected SCAF in more than a quarter of CS patients. This experience confirms the relevance of implanting CS patients, for maximizing the possibilities to detect AF, following failure of Holter monitoring, according to guidelines. However, there is need to demonstrate that shift to oral anticoagulation following SCAF detection is associated with reduced risk of recurrent stroke.


Subject(s)
Atrial Fibrillation , Ischemic Stroke , Stroke , Aged , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Electrocardiography , Electrocardiography, Ambulatory , Female , Humans , Risk Factors , Stroke/epidemiology
18.
J Cardiovasc Med (Hagerstown) ; 22(10): 751-758, 2021 10 01.
Article in English | MEDLINE | ID: mdl-34009182

ABSTRACT

AIMS: Radiation use in medicine has significantly increased over the last decade, and cardiologists are among the specialists most responsible for X-ray exposure. The present study investigates a broad range of aspects, from specific European Union directives to general practical principles, related to radiation management among a national cohort of cardiologists. METHODS AND RESULTS: A voluntary 31-question survey was run on the Italian Arrhythmology and Pacing Society (AIAC) website. From June 2019 to January 2020, 125 cardiologists, routinely performing interventional electrophysiology, participated in the survey. Eighty-seven (70.2%) participants are aware of the recent European Directive (Euratom 2013/59), although only 35 (28.2%) declare to have read the document in detail. Ninety-six (77.4%) participants register the dose delivered to the patient in each procedure, in 66.1% of the cases both as fluoroscopy time and dose area product. Years of exposition (P = 0.009) and working in centers performing pediatric procedures (P = 0.021) related to greater degree of X-ray equipment optimization. The majority of participants (72, 58.1%) did not recently attend radioprotection courses. The latter is related to increased awareness of techniques to reduce radiation exposure (96% vs. 81%, P = 0.022), registration of the delivered dose in each procedure (92% vs. 67%, P = 0.009), and X-ray equipment optimization (50% vs. 36%, P = 0.006). CONCLUSION: Italian interventional cardiologists show an acceptable level of radiation awareness and knowledge of updated European directives. However, there is clear space for improvement. Comparison to other health professionals, both at national and international levels, is needed to pursue proper X-ray management and protect public health.


Subject(s)
Electrophysiologic Techniques, Cardiac , Occupational Exposure , Radiation Exposure , Safety Management , Cardiac Electrophysiology/standards , Cardiology/standards , Electrophysiologic Techniques, Cardiac/adverse effects , Electrophysiologic Techniques, Cardiac/methods , Electrophysiologic Techniques, Cardiac/standards , Health Knowledge, Attitudes, Practice , Humans , Italy , Occupational Exposure/analysis , Occupational Exposure/prevention & control , Occupational Exposure/statistics & numerical data , Radiation Exposure/analysis , Radiation Exposure/prevention & control , Radiation Exposure/statistics & numerical data , Safety Management/methods , Safety Management/organization & administration , Surveys and Questionnaires
19.
Int J Cardiol ; 334: 49-54, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-33930512

ABSTRACT

BACKGROUND: The remote follow-up of pacemakers and implantable cardiac defibrillators (ICDs) usually includes scheduled checks and alert transmissions. However, this results in a high volume of remote data reviews to be managed. We measured the relative contribution of scheduled and alert transmissions to the detection of relevant conditions, and the workload generated by their management. METHODS: At our center, the frequency of remote scheduled transmissions is 4/year. Moreover, all system-integrity and clinical alerts are turned on for wireless notification. We calculated the number of transmissions received from January to December 2020, and identified transmissions that necessitated in-hospital access for further assessment and transmissions that required clinical discussion with the physician. For all alert transmissions, we identified whether the alert was clinically meaningful (i.e. center was not previously aware of the condition and no action had yet been taken to treat it). RESULTS: Of 8545 transmissions received from 1697 pacemakers and ICDs, 5766 (67%) were scheduled and 2779 (33%) were alert transmissions received from 764 patients (45%); 499 (9%) scheduled transmissions required clinical discussion with the physician, but only 2 of these necessitated in-hospital visits for further assessment. Of the alert transmissions, 664 (24%) required clinical discussion, and 75 (3%) necessitated in-hospital visits. The proportion of alerts judged clinically meaningful was 7%. CONCLUSION: Scheduled transmissions generate 67% of remote data reviews for pacemakers and ICDs, but their ability to detect clinically relevant events is very low. A strategy that relies exclusively on alert transmissions could ensure continuity of patient monitoring while reducing the workload at the center.


Subject(s)
Defibrillators, Implantable , Electronics , Follow-Up Studies , Humans , Monitoring, Physiologic , Workload
SELECTION OF CITATIONS
SEARCH DETAIL
...