Europace ; 16(5): 689-97, 2014 May.
Article in English | MEDLINE | ID: mdl-24500787

ABSTRACT

AIMS: The OPTI-MIND study aims to collect 2-year clinical outcomes of pacemaker patients in real-world clinical practice, overall and according to patient characteristics and pacemaker settings. METHODS AND RESULTS: The present analysis of the OPTI-MIND study describes the programmed device settings after discharge from the pacemaker implant. The objective was to determine whether these settings fit recent guidelines for device-programmed physiological pacing based on the preservation of atrioventricular synchrony, avoiding unnecessary pacing, ensuring rate increase during exercise or preventing neurally mediated symptoms. A total of 1740 patients were enroled at 68 centres worldwide. Baseline patient characteristics and device programming settings are available in 1674 of 1740 patients (96%). Guidelines to ensure physiological pacing were followed in 41% of patients: in patients with sinus node disease (SND), and without atrioventricular block (AVB), device programming could have led to unnecessary right ventricular pacing in 38% of patients. In SND patients with chronotropic incompetence, assisted rate increase during exercise was not programmed in 42% of patients. In 11% of patients with AVB, atrioventricular (AV) synchrony was not pursued; the main drivers being advanced age and history of atrial fibrillation. Patients with both SND and AVB were generally programmed physiologically (87%). CONCLUSION: The present analysis showed that frequent deviations occurred when comparing the device settings at discharge from the pacemaker implant in clinical practice to the available guidelines on pacing mode selection. Analysis of 2-year outcomes in the OPTI-MIND study will provide an insight into whether specific physiological settings could improve the quality of pacing with a positive effect on patient outcome.


Subject(s)
Atrial Fibrillation/therapy , Atrioventricular Block/therapy , Cardiac Pacing, Artificial/methods , Pacemaker, Artificial , Sick Sinus Syndrome/therapy , Aged , Aged, 80 and over , Cardiac Pacing, Artificial/standards , Cohort Studies , Female , Guideline Adherence/statistics & numerical data , Humans , Male , Middle Aged , Practice Guidelines as Topic , Prospective Studies , Treatment Outcome
2.
Pacing Clin Electrophysiol ; 26(4 Pt 1): 827-35, 2003 Apr.
Article in English | MEDLINE | ID: mdl-12715842

ABSTRACT

AIMS: To determine whether the loss of repetitive slow pathway conduction identifies a successful radiofrequency ablation of atrioventricular nodal reentry tachycardia (AVNRT). METHODS AND RESULTS: Thirty nine consecutive patients undergoing ablation of AVNRT using the slow pathway approach were included. At baseline and after each radiofrequency application with an episode of junctional rhythm, repetitive slow pathway conduction was assessed as follows: Effective refractory period of the fast pathway was determined. The coupling interval of the first atrial extrastimulus (A2) was set at 30 ms below the effective refractory period of the fast pathway to ensure its conduction via the slow pathway. The second atrial extrastimulus (A3) was introduced at progressively longer coupling intervals starting from 200 ms until: (1) it propagated to the His bundle or (2) an anterogradely blocked AV nodal echo of A2 appeared before a conducted A3 depolarized the atrium in the His bundle electrogram. The response was termed repetitive slow pathway conduction if A3 was conducted with an AH > 200 ms. Application was considered successful if no AVNRT could be induced. Repetitive slow pathway conduction was present after 1 of 39 successful and after 34 of 40 ineffective applications (P < 0.0001). Repetitive slow pathway conduction identified a successful application with 97% sensitivity, 86% specificity, 86% positive predictive value, and 97% negative predictive value. CONCLUSION: The presence of repetitive slow pathway conduction identifies an unsuccessful application with a clinically meaningful negative predictive value.


Subject(s)
Catheter Ablation/methods , Tachycardia, Atrioventricular Nodal Reentry/surgery , Chi-Square Distribution , Electrocardiography , Humans , Predictive Value of Tests , Sensitivity and Specificity , Tachycardia, Atrioventricular Nodal Reentry/physiopathology , Treatment Outcome