Results 1 - 20 de 58
Filter
1.
Sci Rep ; 14(1): 13122, 2024 06 07.
Article in English | MEDLINE | ID: mdl-38849417

ABSTRACT

Deep learning-based methods have demonstrated high classification performance in the detection of cardiovascular diseases from electrocardiograms (ECGs). However, their blackbox character and the associated lack of interpretability limit their clinical applicability. To overcome existing limitations, we present a novel deep learning architecture for interpretable ECG analysis (xECGArch). For the first time, short- and long-term features are analyzed by two independent convolutional neural networks (CNNs) and combined into an ensemble, which is extended by methods of explainable artificial intelligence (xAI) to whiten the blackbox. To demonstrate the trustworthiness of xECGArch, perturbation analysis was used to compare 13 different xAI methods. We parameterized xECGArch for atrial fibrillation (AF) detection using four public ECG databases ( n = 9854 ECGs) and achieved an F1 score of 95.43% in AF versus non-AF classification on an unseen ECG test dataset. A systematic comparison of xAI methods showed that deep Taylor decomposition provided the most trustworthy explanations ( + 24 % compared to the second-best approach). xECGArch can account for short- and long-term features corresponding to clinical features of morphology and rhythm, respectively. Further research will focus on the relationship between xECGArch features and clinical features, which may help in medical applications for diagnosis and therapy.


Subject(s)
Atrial Fibrillation , Deep Learning , Electrocardiography , Neural Networks, Computer , Electrocardiography/methods , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Databases, Factual , Artificial Intelligence , Algorithms
2.
Mult Scler Relat Disord ; 88: 105721, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38885599

ABSTRACT

INTRODUCTION: Multiple sclerosis (MS) is the most common chronic inflammatory disease of the central nervous system. The progressive impairment of gait is one of the most important pathognomic symptoms which are associated with falls and fear of falling (FOF) in people with MS (pwMS). 60 % of pwMS show a FOF, which leads to restrictions in mobility as well as physical activity and reduces the quality of life in general. Therefore, early detection of FOF is crucial because it enables early implementation of rehabilitation strategies as well as clinical decision-making to reduce progression. Qualitative and quantitative evaluation of gait pattern is an essential aspect of disease assessment and can provide valuable insights for personalized treatment decisions in pwMS. Our objective was to identify the most appropriate clinical gait analysis methods to identify FOF in pwMS and to detect the optimal machine learning (ML) algorithms to predict FOF using the complex multidimensional data from gait analysis. METHODS: Data of 1240 pwMS was recorded at the MS Centre of the University Hospital Dresden between November 2020 and September 2021. Patients performed a multidimensional gait analysis with pressure and motion sensors, as well as patient-reported outcomes (PROs), according to a standardized protocol. A feature selection ensemble (FS-Ensemble) was developed to improve the classification performance. The FS-Ensemble consisted of four filtering methods: Chi-square test, information gain, minimum redundancy maximum relevance and ReliefF. Gaussian Naive Bayes, Decision Tree, k-Nearest Neighbor, and Support Vector Machines (SVM) were used to identify FOF. RESULTS: The descriptive analysis showed that 37 % of the 1240 pwMS had a FOF (n = 458; age: 51 ± 16 years, 76 % women, median EDSS: 4.0). The FS-Ensemble improved classification performance in most cases. The SVM showed the best performance of the four classification models in detecting FOF. The PROs showed the best F1 scores (Early Mobility Impairment Questionnaire F1 = 0.81 ± 0.00 and 12-item Multiple Sclerosis Scale F1 = 0.80 ± 0.00). CONCLUSION: FOF is an important psychological risk factor associated with an increased risk of falls. To integrate a functional early warning system for fall detection into MS management and progression monitoring, it is necessary to detect the relevant gait parameters as well as assessment methods. In this context, ML strategies allow the integration of gait parameters from clinical routine to support the initiation of early rehabilitation measures and adaptation of course-modifying therapeutics. The results of this study confirm that patients' self-assessments play an important role in disease management.

3.
Sensors (Basel) ; 24(10)2024 May 15.
Article in English | MEDLINE | ID: mdl-38794005

ABSTRACT

Beat-to-beat (B2B) variability in biomedical signals has been shown to have high diagnostic power in the treatment of various cardiovascular and autonomic disorders. In recent years, new techniques and devices have been developed to enable non-invasive blood pressure (BP) measurements. In this work, we aim to establish the concept of two-dimensional signal warping, an approved method from ECG signal processing, for non-invasive continuous BP signals. To this end, we introduce a novel BP-specific beat annotation algorithm and a B2B-BP fluctuation (B2B-BPF) metric novel for BP measurements that considers the entire BP waveform. In addition to careful validation with synthetic data, we applied the generated analysis pipeline to non-invasive continuous BP signals of 44 healthy pregnant women (30.9 ± 5.7 years) between the 21st and 30th week of gestation (WOG). In line with established variability metrics, a significant increase (p < 0.05) in B2B-BPF can be observed with advancing WOGs. Our processing pipeline enables robust extraction of B2B-BPF, demonstrates the influence of various factors such as increasing WOG or exercise on blood pressure during pregnancy, and indicates the potential of novel non-invasive biosignal sensing techniques in diagnostics. The results represent B2B-BP changes in healthy pregnant women and allow for future comparison with those signals acquired from women with hypertensive disorders.


Subject(s)
Algorithms , Blood Pressure Determination , Blood Pressure , Signal Processing, Computer-Assisted , Humans , Female , Pregnancy , Blood Pressure/physiology , Adult , Blood Pressure Determination/methods , Electrocardiography/methods , Heart Rate/physiology
4.
Sensors (Basel) ; 24(3)2024 Jan 24.
Article in English | MEDLINE | ID: mdl-38339484

ABSTRACT

Postural deformities often manifest themselves in a sagittal imbalance and an asymmetric morphology of the torso. As a novel topographic method, torsobarography assesses the morphology of the back by analysing pressure distribution along the torso in a lying position. At torsobarography's core is a capacitive pressure sensor array. To evaluate its feasibility as a diagnostic tool, the reproducibility of the system and extracted anatomical associated parameters were evaluated on 40 subjects. Landmarks and reference distances were identified within the pressure images. The examined parameters describe the shape of the spine, various structures of the trunk symmetry, such as the scapulae, and the pelvic posture. The results showed that the localisation of the different structures performs with a good (ICC > 0.75) to excellent (ICC > 0.90) reliability. In particular, parameters for approximating the sagittal spine shape were reliably reproduced (ICC > 0.83). Lower reliability was observed for asymmetry parameters, which can be related to the low variability within the subject group. Nonetheless, the reliability levels of selected parameters are comparable to commercial systems. This study demonstrates the substantial potential of torsobarography at its current stage for reliable posture analysis and may pave the way as an early detection system for postural deformities.


Subject(s)
Posture , Spine , Humans , Reproducibility of Results , Observer Variation , Pelvis
5.
PLoS One ; 18(11): e0294069, 2023.
Article in English | MEDLINE | ID: mdl-37943894

ABSTRACT

Numerous vital signs are reported in association with stress response assessment, but their application varies widely. This work provides an overview over methods for stress induction and strain assessment, and presents a multimodal experimental study to identify the most important vital signs for effective assessment of the response to acute mental stress. We induced acute mental stress in 65 healthy participants with the Mannheim Multicomponent Stress Test and acquired self-assessment measures (Likert scale, Self-Assessment Manikin), salivary α-amylase and cortisol concentrations as well as 60 vital signs from biosignals, such as heart rate variability parameters, QT variability parameters, skin conductance level, and breath rate. By means of statistical testing and a self-optimizing logistic regression, we identified the most important biosignal vital signs. Fifteen biosignal vital signs related to ventricular repolarization variability, blood pressure, skin conductance, and respiration showed significant results. The logistic regression converged with QT variability index, left ventricular work index, earlobe pulse arrival time, skin conductance level, rise time and number of skin conductance responses, breath rate, and breath rate variability (F1 = 0.82). Self-assessment measures indicated successful stress induction. α-amylase and cortisol showed effect sizes of -0.78 and 0.55, respectively. In summary, the hypothalamic-pituitary-adrenocortical axis and sympathetic nervous system were successfully activated. Our findings facilitate a coherent and integrative understanding of the assessment of the stress response and help to align applications and future research concerning acute mental stress.


Subject(s)
Hydrocortisone , Salivary alpha-Amylases , Humans , Stress, Psychological , Sympathetic Nervous System/metabolism , Salivary alpha-Amylases/metabolism , Blood Pressure , Saliva/metabolism , Hypothalamo-Hypophyseal System/metabolism , Pituitary-Adrenal System/metabolism
6.
Sensors (Basel) ; 23(14)2023 Jul 18.
Article in English | MEDLINE | ID: mdl-37514793

ABSTRACT

The soft tissues of residual limb amputees are subject to large volume fluctuations over the course of a day. Volume fluctuations in residual limbs can lead to local pressure marks, causing discomfort, pain and rejection of prostheses. Existing methods for measuring interface stress encounter several limitations. A major problem is that the measurement instrumentation is applied in the sensitive interface between the prosthesis and residual limb. This paper presents the principle investigation of a non-intrusive technique to evaluate the fit of orthopaedic prosthesis sockets in transfemoral amputees based on experimentally obtained vibrational data. The proposed approach is based on changes in the dynamical behaviour detectable at the outer surface of prostheses; thus, the described interface is not affected. Based on the experimental investigations shown and the derived results, it can be concluded that structural dynamic measurements are a promising non-intrusive technique to evaluate the fit of orthopaedic prosthesis sockets in transfemoral amputee patients. The obtained resonance frequency changes of 2% are a good indicator of successful applicabilityas these changes can be detected without the need for complex measurement devices.


Subject(s)
Amputees , Artificial Limbs , Orthopedics , Humans , Prosthesis Design , Prosthesis Implantation , Amputation Stumps
7.
Cancers (Basel) ; 15(10)2023 May 11.
Article in English | MEDLINE | ID: mdl-37345051

ABSTRACT

Previous studies suggest that the topological properties of structural and functional neural networks in glioma patients are altered beyond the tumor location. These alterations are due to the dynamic interactions with large-scale neural circuits. Understanding and describing these interactions may be an important step towards deciphering glioma disease evolution. In this study, we analyze structural and functional brain networks in terms of determining the correlation between network robustness and topological features regarding the default-mode network (DMN), comparing prognostically differing patient groups to healthy controls. We determine the driver nodes of these networks, which are receptive to outside signals, and the critical nodes as the most important elements for controllability since their removal will dramatically affect network controllability. Our results suggest that network controllability and robustness of the DMN is decreased in glioma patients. We found losses of driver and critical nodes in patients, especially in the prognostically less favorable IDH wildtype (IDHwt) patients, which might reflect lesion-induced network disintegration. On the other hand, topological shifts of driver and critical nodes, and even increases in the number of critical nodes, were observed mainly in IDH mutated (IDHmut) patients, which might relate to varying degrees of network plasticity accompanying the chronic disease course in some of the patients, depending on tumor growth dynamics. We hereby implement a novel approach for further exploring disease evolution in brain cancer under the aspects of neural network controllability and robustness in glioma patients.

8.
Sensors (Basel) ; 23(3)2023 Jan 17.
Article in English | MEDLINE | ID: mdl-36772102

ABSTRACT

The rowing technique is a key factor in the overall rowing performance. Nowadays the athletes' performance is so advanced that even small differences in technique can have an impact on sport competitions. To further improve the athletes' performance, individualized rowing is necessary. This can be achieved by intelligent measurement technology that provides direct feedback. To address this issue, we developed a novel wireless rowing measurement system (WiRMS) that acquires rowing movement and measures muscle activity using electromyography (EMG). Our measurement system is able to measure several parameters simultaneously: the rowing forces, the pressure distribution on the scull, the oar angles, the seat displacement and the boat acceleration. WiRMS was evaluated in a proof-of-concept study with seven experienced athletes performing a training on water. Evaluation results showed that WiRMS is able to assess the rower's performance by recording the rower's movement and force applied to the scull. We found significant correlations (p < 0.001) between stroke rate and drive-to-recovery ratio. By incorporating EMG data, a precise temporal assignment of the activated muscles and their contribution to the rowing motion was possible. Furthermore, we were able to show that the rower applies the force to the scull mainly with the index and middle fingers.


Subject(s)
Athletic Performance , Water Sports , Humans , Biomechanical Phenomena , Ergometry/methods , Water Sports/physiology , Athletes , Athletic Performance/physiology
9.
Biomedicines ; 10(12)2022 Nov 28.
Article in English | MEDLINE | ID: mdl-36551812

ABSTRACT

Establishing an objective quality assessment of an organ prior to transplantation can help prevent unnecessary discard of the organ and reduce the probability of functional failure. In this regard, normothermic machine perfusion (NMP) offers new possibilities for organ evaluation. However, to date, few studies have addressed the identification of markers and analytical tools to determine graft quality. In this study, function and injury markers were measured in blood and urine during NMP of 26 porcine kidneys and correlated with ex vivo inulin clearance behavior. Significant differentiation of kidneys according to their function could be achieved by oxygen consumption, oxygen delivery, renal blood flow, arterial pressure, intrarenal resistance, kidney temperature, relative urea concentration, and urine production. In addition, classifications were accomplished with supervised learning methods and histological analysis to predict renal function ex vivo. Classificators (support vector machines, k-nearest-neighbor, logistic regression and naive bayes) based on relevant markers in urine and blood achieved 75% and 83% accuracy in the validation and test set, respectively. A correlation between histological damage and function could not be detected. The measurement of blood and urine markers provides information of preoperative renal quality, which can used in future to establish an objective quality assessment.

10.
Brain Sci ; 12(11)2022 Oct 31.
Article in English | MEDLINE | ID: mdl-36358403

ABSTRACT

One of the common causes of falls in people with Multiple Sclerosis (pwMS) is walking impairment. Therefore, assessment of gait is of importance in MS. Gait analysis and fall detection can take place in the clinical context using a wide variety of available methods. However, combining these methods while using machine learning algorithms for detecting falls has not been performed. Our objective was to determine the most relevant method for determining fall risk by analyzing eleven different gait data sets with machine learning algorithms. In addition, we examined the most important features of fall detection. A new feature selection ensemble (FS-Ensemble) and four classification models (Gaussian Naive Bayes, Decision Tree, k-Nearest Neighbor, Support Vector Machine) were used. The FS-Ensemble consisted of four filter methods: Chi-square test, information gain, Minimum Redundancy Maximum Relevance and RelieF. Various thresholds (50%, 25% and 10%) and combination methods (Union, Union 2, Union 3 and Intersection) were examined. Patient-reported outcomes using specialized walking questionnaires such as the 12-item Multiple Sclerosis Walking Scale (MSWS-12) and the Early Mobility Impairment Questionnaire (EMIQ) achieved the best performances with an F1 score of 0.54 for detecting falls. A combination of selected features of MSWS-12 and EMIQ, including the estimation of walking, running and stair climbing ability, the subjective effort as well as necessary concentration and walking fluency during walking, the frequency of stumbling and the indication of avoidance of social activity achieved the best recall of 75%. The Gaussian Naive Bayes was the best classification model for detecting falls with almost all data sets. FS-Ensemble improved the classification models and is an appropriate technique for reducing data sets with a large number of features. Future research on other risk factors, such as fear of falling, could provide further insights.

11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 3623-3627, 2022 07.
Article in English | MEDLINE | ID: mdl-36085996

ABSTRACT

In this work, four different algorithms (fast Fourier transform FFT, short-time Fourier transform STFT, continuous wavelet transform CWT, and instantaneous frequency IF) for calculating median frequency (MDF) from surface EMG signals were investigated for studying muscle fatigue during a on-water rowing training. The study protocol included 5 consecutive parts with increasing stroke rate. Six athletes participated in the study aged 36.6+-14.6 years and a rowing experience of 6 to 35 years. We considered eight muscles: biceps brachii right, biceps brachii left, latissimus dorsi right, latissimus dorsi left, erector spinae right, erector spinae left, rectus femoris and biceps femoris. By applying Friedmann test, we found a significant difference in MDF behavior between algorithms in assessing muscle fatigue . Correlation analyses showed significant correlations between muscle activity duration tact and MDF, which differs for the four considered algorithms and should be taken into account in further experiments. With CWT showing the smallest correlation to tact it might be more robust against time window variations. Our study provides a basis for the development of improved methods for more robust, non-invasive, and continuous detection of muscle fatigue in experiments with dynamic on-water rowing study designs.


Subject(s)
Muscle Fatigue , Water Sports , Electromyography/methods , Humans , Muscle Fatigue/physiology , Muscle, Skeletal/physiology , Water
12.
Biomedicines ; 10(2)2022 Feb 07.
Article in English | MEDLINE | ID: mdl-35203605

ABSTRACT

Facing an ongoing organ shortage in transplant medicine, strategies to increase the use of organs from marginal donors by objective organ assessment are being fostered. In this context, normothermic machine perfusion provides a platform for ex vivo organ evaluation during preservation. Consequently, analytical tools are emerging to determine organ quality. In this study, hyperspectral imaging (HSI) in the wavelength range of 550-995 nm was applied. Classification of 26 kidneys based on HSI was established using KidneyResNet, a convolutional neural network (CNN) based on the ResNet-18 architecture, to predict inulin clearance behavior. HSI preprocessing steps were implemented, including automated region of interest (ROI) selection, before executing the KidneyResNet algorithm. Training parameters and augmentation methods were investigated concerning their influence on the prediction. When classifying individual ROIs, the optimized KidneyResNet model achieved 84% and 62% accuracy in the validation and test set, respectively. With a majority decision on all ROIs of a kidney, the accuracy increased to 96% (validation set) and 100% (test set). These results demonstrate the feasibility of HSI in combination with KidneyResNet for non-invasive prediction of ex vivo kidney function. This knowledge of preoperative renal quality may support the organ acceptance decision.

13.
Physiol Meas ; 43(2)2022 03 21.
Article in English | MEDLINE | ID: mdl-35168227

ABSTRACT

Objective. After skin flap transplants, perfusion strength monitoring is essential for the early detection of tissue perfusion disorders and thus to ensure the survival of skin flaps. Camera-based photoplethysmography (cbPPG) is a non-contact measurement method, using video cameras and ambient light, which provides spatially resolved information about tissue perfusion. It has not been researched yet whether the measurement depth of cbPPG, which is limited by the penetration depth of ambient light, is sufficient to reach pulsatile vessels and thus to measure the perfusion strength in regions that are relevant for skin flap transplants.Approach. We applied constant negative pressure (compared to ambient pressure) to the anterior thighs of 40 healthy subjects. Seven measurements (two before and five up to 90 min after the intervention) were acquired using an RGB video camera and photospectrometry simultaneously. We investigated the performance of different algorithmic approaches for perfusion strength assessment, including the signal-to-noise ratio (SNR), its logarithmic components logS and logN, amplitude maps, and the amplitude height of alternating and direct signal components.Main results. We found strong correlations of up tor= 0.694 (p< 0.001) between photospectrometric measurements and all cbPPG parameters except SNR when using the green color channel. The transfer of cbPPG signals to POS, CHROM, and O3C did not lead to systematic improvements. However, for direct signal components, the transformation to O3C led to correlations of up tor= 0.744 (p< 0.001) with photospectrometric measurements.Significance. Our results indicate that a camera-based perfusion strength assessment in tissue with deep-seated pulsatile vessels is possible.


Subject(s)
Photoplethysmography , Transplants , Body Height , Humans , Perfusion , Thigh
14.
Microvasc Res ; 140: 104301, 2022 03.
Article in English | MEDLINE | ID: mdl-34971695

ABSTRACT

BACKGROUND: Topical negative pressure wound therapy (TNPWT) is a regularly used method in modern wound treatment with a growing and diverse potential for clinical use. So far positive effects on microcirculation have been observed and examined, although precise statements on the underlying mechanism appear unsatisfying. OBJECTIVE: The aim of our study was to extend the understanding of the effect of TNPWT on tissue perfusion and determine the time frame and the extent to which the tissue perfusion changes due to TNPWT. MATERIAL AND METHODS: TNPWT was applied to the anterior thighs of 40 healthy individuals for 30 min, respectively. Before and up to 90 min after the application, measurements of the amount of regional haemoglobin (rHb), capillary venous oxygen saturation (sO2), blood flow (flow) and velocity were conducted with spectrophotometry (combining white light spectrometry and laser Doppler spectroscopy) within two different depths/skin layers. A superficial measuring probe for depths up to 3 mm and a deep measuring probe for up to 7 mm were used. RESULTS: All parameters show significant changes after the intervention compared to baseline measurements. The greater effect was seen superficially. The superficially measured rHb, sO2 and flow showed a significant increase and stayed above the baseline at the end of the protocol. Whereas deeply measured, the rHb initially showed a decrease. The flow and sO2 showed a significant increase up to 60 min after the intervention. CONCLUSION: The application of TNPWT on healthy tissue shows an increase in capillary-venous oxygen saturation and haemoglobin concentration of at least 90 min after intervention. A possible use in clinical practice for preconditioning to enhance wound healing for high-risk patients to develop wound healing disorder, requires further studies to investigate the actual duration of the effect.


Subject(s)
Capillaries/physiology , Microcirculation , Negative-Pressure Wound Therapy , Skin/blood supply , Adult , Blood Flow Velocity , Female , Healthy Volunteers , Hemoglobins/metabolism , Humans , Laser-Doppler Flowmetry , Male , Oxygen/blood , Oxygen Saturation , Pilot Projects , Prospective Studies , Regional Blood Flow , Spectrophotometry , Thigh , Time Factors , Young Adult
15.
ASAIO J ; 68(9): 1211-1218, 2022 09 01.
Article in English | MEDLINE | ID: mdl-34967777

ABSTRACT

Normothermic machine perfusion (NMP) offers a unique opportunity to objectively assess donor organ quality. This study describes the evaluation of inulin clearance as a potential marker for the ex vivo function of porcine kidneys during NMP. The function assessment was performed in both kidneys from slaughterhouse pigs (n = 20) and kidneys from pigs in a laboratory setting (n = 28). The kidneys were exposed to different warm ischemia times (WIT). After a period of static cold storage, the kidneys underwent a 4-hour NMP with autologous whole blood. Inulin clearance, hemodynamic parameters, and urine output were measured. Based on the inulin excretion behavior laboratory pig kidneys were assigned to three classes (functional, limited functional, and nonfunctional), slaughterhouse pig kidneys to two classes (limited functional and nonfunctional), respectively. Contrary to the marginal kidneys of the slaughterhouse pigs, the functional variation of kidneys of the laboratory pigs was associated with the WIT. A correlation between functional kidneys and a WIT less than 25 min was shown. Because none of the slaughterhouse pig kidneys could be assigned to the functional class, only the laboratory pig kidneys were used for examinations with functional markers. Renal blood flow and urine output during NMP correlated significantly ( p < 0.01) with ex vivo kidney function. This study demonstrated that inulin is a marker of high quality for the evaluation of suggested kidney function after NMP with whole blood. Furthermore, surrogate markers measured during NMP can be used to describe and predict the physiologic behavior of kidneys before transplantation.


Subject(s)
Kidney Transplantation , Organ Preservation , Animals , Biomarkers , Inulin , Kidney/physiology , Perfusion , Swine
16.
Brain Sci ; 11(8)2021 Aug 07.
Article in English | MEDLINE | ID: mdl-34439668

ABSTRACT

In multiple sclerosis (MS), gait impairment is one of the most prominent symptoms. For a sensitive assessment of pathological gait patterns, a comprehensive analysis and processing of several gait analysis systems is necessary. The objective of this work was to determine the best diagnostic gait system (DIERS pedogait, GAITRite system, and Mobility Lab) using six machine learning algorithms for the differentiation between people with multiple sclerosis (pwMS) and healthy controls, between pwMS with and without fatigue and between pwMS with mild and moderate impairment. The data of the three gait systems were assessed on 54 pwMS and 38 healthy controls. Gaussian Naive Bayes, Decision Tree, k-Nearest Neighbor, and Support Vector Machines (SVM) with linear, radial basis function (rbf) and polynomial kernel were applied for the detection of subtle walking changes. The best performance for a healthy-sick classification was achieved on the DIERS data with a SVM rbf kernel (κ = 0.49 ± 0.11). For differentiating between pwMS with mild and moderate disability, the GAITRite data with the SVM linear kernel (κ = 0.61 ± 0.06) showed the best performance. This study demonstrates that machine learning methods are suitable for identifying pathologic gait patterns in early MS.

17.
J Biomed Opt ; 26(7)2021 07.
Article in English | MEDLINE | ID: mdl-34304399

ABSTRACT

SIGNIFICANCE: Hyperspectral and multispectral imaging (HMSI) in medical applications provides information about the physiology, morphology, and composition of tissues and organs. The use of these technologies enables the evaluation of biological objects and can potentially be applied as an objective assessment tool for medical professionals. AIM: Our study investigates HMSI systems for their usability in medical applications. APPROACH: Four HMSI systems (one hyperspectral pushbroom camera and three multispectral snapshot cameras) were examined and a spectrometer was used as a reference system, which was initially validated with a standardized color chart. The spectral accuracy of the cameras reproducing chemical properties of different biological objects (porcine blood, physiological porcine tissue, and pathological porcine tissue) was analyzed using the Pearson correlation coefficient. RESULTS: All the HMSI cameras examined were able to provide the characteristic spectral properties of blood and tissues. A pushbroom camera and two snapshot systems achieve Pearson coefficients of at least 0.97 compared to the ground truth, indicating a very high positive correlation. Only one snapshot camera performs moderately to high positive correlation (0.59 to 0.85). CONCLUSION: The knowledge of the suitability of HMSI cameras for accurate measurement of chemical properties of biological objects offers a good opportunity for the selection of the optimal imaging tool for specific medical applications, such as organ transplantation.


Subject(s)
Diagnostic Imaging , Organ Transplantation , Animals , Swine
18.
Front Neurosci ; 14: 547433, 2020.
Article in English | MEDLINE | ID: mdl-33071732

ABSTRACT

Spontaneous baroreflex sensitivity (BRS) is a widely used tool for the quantification of the cardiovascular regulation. Numerous groups use the xBRS method, which calculates the cross-correlation between the systolic beat-to-beat blood pressure and the R-R interval (resampled at 1 Hz) in a 10 s sliding window, with 0-5 s delays for the interval. The delay with the highest correlation is selected and, if significant, the quotient of the standard deviations of the R-R intervals and the systolic blood pressures is recorded as the corresponding xBRS value. In this paper we test the hypothesis that the xBRS method quantifies the causal interactions of spontaneous BRS from non-invasive measurements at rest. We use the term spontaneous BRS in the sense of the sensitivity curve is calculated from non-interventional, i.e., spontaneous, baroreceptor activity. This study includes retrospective analysis of 1828 measurements containing ECG as well as continues blood pressure under resting conditions. Our results show a high correlation between the heart rate - systolic blood pressure variability (HRV/BPV) quotient and the xBRS (r = 0.94, p < 0.001). For a deeper understanding we conducted two surrogate analyses by substituting the systolic blood pressure by its reversed time series. These showed that the xBRS method was not able to quantify causal relationships between the two signals. It was not possible to distinguish between random and baroreflex controlled sequences. It appears xBRS rather determines the HRV/BPV quotient. We conclude that the xBRS method has a potentially large bias in characterizing the capacity of the arterial baroreflex under resting conditions. During slow breathing, estimates for xBRS are significantly increased, which clearly shows that measurements at rest only involve limited baroreflex activity, but does neither challenge, nor show the full range of the arterial baroreflex regulatory capacity. We show that xBRS is exclusively dominated by the heart rate to systolic blood pressure ratio (r = 0.965, p < 0.001). Further investigations should focus on additional autonomous testing procedures such as slow breathing or orthostatic testing to provide a basis for a non-invasive evaluation of baroreflex sensitivity.

19.
Z Orthop Unfall ; 158(3): 318-332, 2020 Jun.
Article in English, German | MEDLINE | ID: mdl-31404938

ABSTRACT

BACKGROUND: The FED method (Fixation, Elongation, Derotation) is a treatment method approach to Patients with scoliosis. The FED method is especially established in Spain and Poland, whereby in Germany it is less well-known. Nevertheless the FED method is within the scope of a research project (Project Number: 19200 BR/3). The purpose of the paper is to characterize the FED method and to highlight the specificities in contrast to the Schroth method, which is international established and especially in Germany. METHODS: This systematic literature research was conducted in Nov 2017-Jan 2018. Therefore common medical and physiotherapeutic databases were used. Furthermore there was a hand search in selected scientific journals. Only a small number of relevant references were identified. That is why the respective authors were asked to provide the full-texts of their papers and to recommend further references. RESULTS: A total of 378 references were identified. After removing duplicates and the content-related selection, 19 references were deemed to be relevant. Based on the analysis of this relevant literature, the FED method was comprehensively characterized. First of all the general structure of the FED method and the scientific evidence for its effectiveness was described. And as a result of the literature research, the operating principles of the FED method were pointed out. Then these operating principles were discussed in comparison with the Schroth method. The Schroth method based on sensomotoric and kinesthetic principles and the correction of the pathologic posture was performed by selective muscle activation and breathing-pattern. Thus, the posture correction will be performed by the patients (auto correction). Compared to the Schroth method, the FED method implements the posture correction by the FED-device. This correction is influenced by mechanical forces with a comparatively high strength and intensity. The repetitive mechanical correction stimulates the sensomotoric system. And due to trophic/biochemical adaptations, the physiological bone growth will be stimulated. CONCLUSION: In total the authors want to clarify, that both treatment methods (Schroth method, FED method) supposed to be applied in consideration of the preconditions of the patients and the pursue of the different treatment goals. Thus, the implementation of treatment methods should be used according to the individual treatment demand and on different stages in the treatment process.


Subject(s)
Physical Therapy Modalities , Scoliosis , Exercise Therapy , Germany , Humans , Poland , Posture , Scoliosis/therapy , Treatment Outcome
20.
Comput Biol Med ; 113: 103395, 2019 10.
Article in English | MEDLINE | ID: mdl-31480008

ABSTRACT

OBJECTIVE: Predicting sepsis onset with a recurrent neural network and performance comparison with InSight - a previously proposed algorithm for the prediction of sepsis onset. METHODOLOGY: A retrospective analysis of adult patients admitted to the intensive care unit (from the MIMIC III database) who did not fall under the definition of sepsis at the time of admission. The area under the receiver operating characteristic (AUROC) measures the performance of the prediction task. We examine the sequence length given to the machine learning algorithms for different points in time before sepsis onset concerning the prediction performance. Additionally, the impact of sepsis onset's definition is investigated. We evaluate the model with a relatively large and thus more representative patient population compared to related works in the field. RESULTS: For a prediction 3 h prior to sepsis onset, our network achieves an AUROC of 0.81 (95% CI: 0.78-0.84). The InSight algorithm achieves an AUROC of 0.72 (95% CI: 0.69-0.75). For a fixed sensitivity of 90% our network reaches a specificity of 47.0% (95% CI: 43.1%-50.8%) compared to 31.1% (95% CI: 24.8%-37.5%) for InSight. In addition, we compare the performance for 6 and 12 h prediction time for both approaches. CONCLUSION: Our findings demonstrate that a recurrent neural network is superior to InSight considering the prediction performance. Most probably, the improvement results from the network's ability of revealing time dependencies. We show that the length of the look back has a significant impact on the performance of the classifier. We also demonstrate that for the correct detection of sepsis onset for a retrospective analysis, further research is necessary.


Subject(s)
Databases, Factual , Diagnosis, Computer-Assisted , Machine Learning , Neural Networks, Computer , Sepsis/diagnosis , Adult , Female , Humans , Male , Middle Aged