Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 58
Filter
1.
Magn Reson Med ; 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38968093

ABSTRACT

PURPOSE: T1 mapping and T1-weighted contrasts have a complimentary but currently under utilized role in fetal MRI. Emerging clinical low field scanners are ideally suited for fetal T1 mapping. The advantages are lower T1 values which results in higher efficiency and reduced field inhomogeneities resulting in a decreased requirement for specialist tools. In addition the increased bore size associated with low field scanners provides improved patient comfort and accessibility. This study aims to demonstrate the feasibility of fetal brain T1 mapping at 0.55T. METHODS: An efficient slice-shuffling inversion-recovery echo-planar imaging (EPI)-based T1-mapping and postprocessing was demonstrated for the fetal brain at 0.55T in a cohort of 38 fetal MRI scans. Robustness analysis was performed and placental measurements were taken for validation. RESULTS: High-quality T1 maps allowing the investigation of subregions in the brain were obtained and significant correlation with gestational age was demonstrated for fetal brain T1 maps ( p < 0 . 05 $$ p<0.05 $$ ) as well as regions-of-interest in the deep gray matter and white matter. CONCLUSIONS: Efficient, quantitative T1 mapping in the fetal brain was demonstrated on a clinical 0.55T MRI scanner, providing foundations for both future research and clinical applications including low-field specific T1-weighted acquisitions.

2.
Magn Reson Med ; 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38860530

ABSTRACT

PURPOSE: This study leverages externally generated Pilot Tone (PT) signals to perform motion-corrected brain MRI for sequences with arbitrary k-space sampling and image contrast. THEORY AND METHODS: PT signals are promising external motion sensors due to their cost-effectiveness, easy workflow, and consistent performance across contrasts and sampling patterns. However, they lack robust calibration pipelines. This work calibrates PT signal to rigid motion parameters acquired during short blocks (˜4 s) of motion calibration (MC) acquisitions, which are short enough to unobstructively fit between acquisitions. MC acquisitions leverage self-navigated trajectories that enable state-of-the-art motion estimation methods for efficient calibration. To capture the range of patient motion occurring throughout the examination, distributed motion calibration (DMC) uses data acquired from MC scans distributed across the entire examination. After calibration, PT is used to retrospectively motion-correct sequences with arbitrary k-space sampling and image contrast. Additionally, a data-driven calibration refinement is proposed to tailor calibration models to individual acquisitions. In vivo experiments involving 12 healthy volunteers tested the DMC protocol's ability to robustly correct subject motion. RESULTS: The proposed calibration pipeline produces pose parameters consistent with reference values, even when distributing only six of these approximately 4-s MC blocks, resulting in a total acquisition time of 22 s. In vivo motion experiments reveal significant ( p < 0.05 $$ p<0.05 $$ ) improved motion correction with increased signal to residual ratio for both MPRAGE and SPACE sequences with standard k-space acquisition, especially when motion is large. Additionally, results highlight the benefits of using a distributed calibration approach. CONCLUSIONS: This study presents a framework for performing motion-corrected brain MRI in sequences with arbitrary k-space encoding and contrast, using externally generated PT signals. The DMC protocol is introduced, promoting observation of patient motion occurring throughout the examination and providing a calibration pipeline suitable for clinical deployment. The method's application is demonstrated in standard volumetric MPRAGE and SPACE sequences.

3.
Magn Reson Med ; 92(2): 715-729, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38623934

ABSTRACT

PURPOSE: We propose a quantitative framework for motion-corrected T2 fetal brain measurements in vivo and validate the single-shot fast spin echo (SS-FSE) sequence to perform these measurements. METHODS: Stacks of two-dimensional SS-FSE slices are acquired with different echo times (TE) and motion-corrected with slice-to-volume reconstruction (SVR). The quantitative T2 maps are obtained by a fit to a dictionary of simulated signals. The sequence is selected using simulated experiments on a numerical phantom and validated on a physical phantom scanned on a 1.5T system. In vivo quantitative T2 maps are obtained for five fetuses with gestational ages (GA) 21-35 weeks on the same 1.5T system. RESULTS: The simulated experiments suggested that a TE of 400 ms combined with the clinically utilized TEs of 80 and 180 ms were most suitable for T2 measurements in the fetal brain. The validation on the physical phantom confirmed that the SS-FSE T2 measurements match the gold standard multi-echo spin echo measurements. We measured average T2s of around 200 and 280 ms in the fetal brain grey and white matter, respectively. This was slightly higher than fetal T2* and the neonatal T2 obtained from previous studies. CONCLUSION: The motion-corrected SS-FSE acquisitions with varying TEs offer a promising practical framework for quantitative T2 measurements of the moving fetus.


Subject(s)
Brain , Fetus , Magnetic Resonance Imaging , Phantoms, Imaging , Humans , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Female , Pregnancy , Fetus/diagnostic imaging , Algorithms , Image Processing, Computer-Assisted/methods , Gestational Age , Reproducibility of Results , Computer Simulation , Image Interpretation, Computer-Assisted/methods , Motion
4.
Magn Reson Med ; 91(5): 2028-2043, 2024 May.
Article in English | MEDLINE | ID: mdl-38173304

ABSTRACT

PURPOSE: To develop a framework that jointly estimates rigid motion and polarizing magnetic field (B0 ) perturbations ( δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ ) for brain MRI using a single navigator of a few milliseconds in duration, and to additionally allow for navigator acquisition at arbitrary timings within any type of sequence to obtain high-temporal resolution estimates. THEORY AND METHODS: Methods exist that match navigator data to a low-resolution single-contrast image (scout) to estimate either motion or δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . In this work, called QUEEN (QUantitatively Enhanced parameter Estimation from Navigators), we propose combined motion and δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ estimation from a fast, tailored trajectory with arbitrary-contrast navigator data. To this end, the concept of a quantitative scout (Q-Scout) acquisition is proposed from which contrast-matched scout data is predicted for each navigator. Finally, navigator trajectories, contrast-matched scout, and δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ are integrated into a motion-informed parallel-imaging framework. RESULTS: Simulations and in vivo experiments show the need to model δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ to obtain accurate motion parameters estimated in the presence of strong δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . Simulations confirm that tailored navigator trajectories are needed to robustly estimate both motion and δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . Furthermore, experiments show that a contrast-matched scout is needed for parameter estimation from multicontrast navigator data. A retrospective, in vivo reconstruction experiment shows improved image quality when using the proposed Q-Scout and QUEEN estimation. CONCLUSIONS: We developed a framework to jointly estimate rigid motion parameters and δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ from navigators. Combing a contrast-matched scout with the proposed trajectory allows for navigator deployment in almost any sequence and/or timing, which allows for higher temporal-resolution motion and δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ estimates.


Subject(s)
Algorithms , Magnetic Resonance Imaging , Retrospective Studies , Motion , Magnetic Resonance Imaging/methods , Neuroimaging , Artifacts , Image Processing, Computer-Assisted/methods , Brain/diagnostic imaging
5.
Radiology ; 309(1): e223050, 2023 10.
Article in English | MEDLINE | ID: mdl-37847139

ABSTRACT

Background The benefits of using low-field-strength fetal MRI to evaluate antenatal development include reduced image artifacts, increased comfort, larger bore size, and potentially reduced costs, but studies about fetal low-field-strength MRI are lacking. Purpose To evaluate the reliability and feasibility of low-field-strength fetal MRI to assess anatomic and functional measures in pregnant participants using a commercially available 0.55-T MRI scanner and a comprehensive 20-minute protocol. Materials and Methods This prospective study was performed at a large teaching hospital (St Thomas' Hospital; London, England) from May to November 2022 in healthy pregnant participants and participants with pregnancy-related abnormalities using a commercially available 0.55-T MRI scanner. A 20-minute protocol was acquired including anatomic T2-weighted fast-spin-echo, quantitative T2*, and diffusion sequences. Key measures like biparietal diameter, transcerebellar diameter, lung volume, and cervical length were evaluated by two radiologists and an MRI-experienced obstetrician. Functional organ-specific mean values were given. Comparison was performed with existing published values and higher-field MRI using linear regression, interobserver correlation, and Bland-Altman plots. Results A total of 79 fetal MRI examinations were performed (mean gestational age, 29.4 weeks ± 5.5 [SD] [age range, 17.6-39.3 weeks]; maternal age, 34.4 years ± 5.3 [age range, 18.4-45.5 years]) in 47 healthy pregnant participants (control participants) and in 32 participants with pregnancy-related abnormalities. The key anatomic two-dimensional measures for the 47 healthy participants agreed with large cross-sectional 1.5-T and 3-T control studies. The interobserver correlations for the biparietal diameter in the first 40 consecutive scans were 0.96 (95% CI: 0.7, 0.99; P = .002) for abnormalities and 0.93 (95% CI: 0.86, 0.97; P < .001) for control participants. Functional features, including placental and brain T2* and placental apparent diffusion coefficient values, strongly correlated with gestational age (mean placental T2* in the control participants: 5.2 msec of decay per week; R2 = 0.66; mean T2* at 30 weeks, 176.6 msec; P < .001). Conclusion The 20-minute low-field-strength fetal MRI examination protocol was capable of producing reliable structural and functional measures of the fetus and placenta in pregnancy. Clinical trial registration no. REC 21/LO/0742 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Gowland in this issue.


Subject(s)
Magnetic Resonance Imaging , Placenta , Adolescent , Adult , Female , Humans , Middle Aged , Pregnancy , Young Adult , Cross-Sectional Studies , Feasibility Studies , Fetus , Magnetic Resonance Imaging/methods , Prospective Studies , Reproducibility of Results
6.
Magn Reson Med ; 89(3): 937-950, 2023 03.
Article in English | MEDLINE | ID: mdl-36352772

ABSTRACT

PURPOSE: The MP2RAGE sequence is typically optimized for either T1 -weighted uniform image (UNI) or gray matter-dominant fluid and white matter suppression (FLAWS) contrast images. Here, the purpose was to optimize an MP2RAGE protocol at 7 Tesla to provide UNI and FLAWS images simultaneously in a clinically applicable acquisition time at <0.7 mm isotropic resolution. METHODS: Using the extended phase graph formalism, the signal evolution of the MP2RAGE sequence was simulated incorporating T2 relaxation, diffusion, RF spoiling, and B1 + variability. Flip angles and TI were optimized at different TRs (TRMP2RAGE ) to produce an optimal contrast-to-noise ratio for UNI and FLAWS images. Simulation results were validated by comparison to MP2RAGE brain scans of 5 healthy subjects, and a final protocol at TRMP2RAGE  = 4000 ms was applied in 19 subjects aged 8-62 years with and without epilepsy. RESULTS: FLAWS contrast images could be obtained while maintaining >85% of the optimal UNI contrast-to-noise ratio. Using TI1 /TI2 /TRMP2RAGE of 650/2280/4000 ms, 6/8 partial Fourier in the inner phase-encoding direction, and GRAPPA factor = 4 in the other, images with 0.65 mm isotropic resolution were produced in <7.5 min. The contrast-to-noise ratio was around 20% smaller at TRMP2RAGE  = 4000 ms compared to that at TRMP2RAGE  = 5000 ms; however, the 20% shorter duration makes TRMP2RAGE  = 4000 ms a good candidate for clinical applications example, pediatrics. CONCLUSION: FLAWS and UNI images could be obtained in a single scan with 0.65 mm isotropic resolution, providing a set of high-contrast images and full brain coverage in a clinically applicable scan time. Images with excellent anatomical detail were demonstrated over a wide age range using the optimized parameter set.


Subject(s)
White Matter , Humans , Child , White Matter/diagnostic imaging , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Gray Matter , Neuroimaging
7.
Front Radiol ; 3: 1327075, 2023.
Article in English | MEDLINE | ID: mdl-38304343

ABSTRACT

Introduction: Ultra-high field MR imaging offers marked gains in signal-to-noise ratio, spatial resolution, and contrast which translate to improved pathological and anatomical sensitivity. These benefits are particularly relevant for the neonatal brain which is rapidly developing and sensitive to injury. However, experience of imaging neonates at 7T has been limited due to regulatory, safety, and practical considerations. We aimed to establish a program for safely acquiring high resolution and contrast brain images from neonates on a 7T system. Methods: Images were acquired from 35 neonates on 44 occasions (median age 39 + 6 postmenstrual weeks, range 33 + 4 to 52 + 6; median body weight 2.93 kg, range 1.57 to 5.3 kg) over a median time of 49 mins 30 s. Peripheral body temperature and physiological measures were recorded throughout scanning. Acquired sequences included T2 weighted (TSE), Actual Flip angle Imaging (AFI), functional MRI (BOLD EPI), susceptibility weighted imaging (SWI), and MR spectroscopy (STEAM). Results: There was no significant difference between temperature before and after scanning (p = 0.76) and image quality assessment compared favorably to state-of-the-art 3T acquisitions. Anatomical imaging demonstrated excellent sensitivity to structures which are typically hard to visualize at lower field strengths including the hippocampus, cerebellum, and vasculature. Images were also acquired with contrast mechanisms which are enhanced at ultra-high field including susceptibility weighted imaging, functional MRI, and MR spectroscopy. Discussion: We demonstrate safety and feasibility of imaging vulnerable neonates at ultra-high field and highlight the untapped potential for providing important new insights into brain development and pathological processes during this critical phase of early life.

8.
Magn Reson Imaging ; 92: 180-186, 2022 10.
Article in English | MEDLINE | ID: mdl-35820546

ABSTRACT

PURPOSE: Universal Pulses (UPs) are excitation pulses that reduce the flip angle inhomogeneity in high field MRI systems without subject-specific optimization, originally developed for parallel transmit (PTX) systems at 7 T. We investigated the potential benefits of UPs for single channel (SC) transmit systems at 3 T, which are widely used for clinical and research imaging, and for which flip angle inhomogeneity can still be problematic. METHODS: SC-UPs were designed using a spiral nonselective k-space trajectory for brain imaging at 3 T using transmit field maps (B1+) and off-resonance maps (B0) acquired on two different scanner types: a 'standard' single channel transmit system and a system with a PTX body coil. The effect of training group size was investigated using data (200 subjects) from the standard system. The PTX system was used to compare SC-UPs to PTX-UPs (15 subjects). In two additional subjects, prospective imaging using SC-UP was studied. RESULTS: Average flip angle homogeneity error fell from 9.5 ± 0.5 % for 'default' excitation to 3.0 ± 0.6 % using SC-UPs trained over 50 subjects. Performance of the UPs was found to steadily improve as training group size increased, but stabilized after ~15 subjects. On the PTX-enabled system, SC-UPs again outperformed default excitation in simulations (4.8 ± 0.6 % error versus 10.6 ± 0.8 % respectively) though greater homogenization could be achieved with PTX-UPs (3.9 ± 0.6 %) and personalized pulses (SC-PP 3.6 ± 1.0 %, PTX-PP 2.9 ± 0.6 %). MP-RAGE imaging using SC-UP resulted in greater separation between grey and white matter signal intensities than default excitation. CONCLUSIONS: SC-UPs can improve excitation homogeneity in standard 3 T systems without further calibration and could be used instead of a default excitation pulse for nonselective neuroimaging at 3 T.


Subject(s)
Brain , Magnetic Resonance Imaging , Algorithms , Brain/diagnostic imaging , Calibration , Humans , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Prospective Studies
9.
Magn Reson Med ; 88(3): 1434-1449, 2022 09.
Article in English | MEDLINE | ID: mdl-35666836

ABSTRACT

PURPOSE: To evaluate specific absorption rate (SAR) and temperature distributions resulting from pediatric exposure to a 7T head coil. METHODS: Exposure from a 297-MHz birdcage head transmit coil (CP mode single-channel transmission) was simulated in several child models (ages 3-14, mass 13.9-50.4 kg) and one adult, using time-domain electromagnetic and thermal solvers. Position variability, age-related changes in dielectric properties, and differences in thermoregulation were also considered. RESULTS: Age-adjusted dielectric properties had little effect in this population. Head average SAR (hdSAR) was the limiting factor for all models centered in the coil. The value of hdSAR (normalized to net power) was found to decrease linearly with increasing mass (R2  = 0.86); no equivalent relationship for peak-spatial 10g averaged SAR (psSAR10g ) was identified. Relatively small (< 10%) variability was observed in hdSAR for position shifts of ±25 mm in each orthogonal direction when normalized to net power; accounting for B1+$$ {\mathrm{B}}_1^{+} $$ efficiency can lead to much larger variability. Position sensitivity of psSAR10g was greater, but in most cases hdSAR remained the limiting quantity. For thermal simulations, if blood temperature is fixed (i.e., asserting good thermoregulation), maximum temperatures are compliant with International Electrotechnical Commission limits during 60-min exposure at the SAR limit. Introducing variable blood temperature leads to core temperature changes proportional to whole-body averaged SAR, exceeding guideline limits for all child models. CONCLUSIONS: Children experienced higher SAR than adults for the 297-MHz head transmit coil examined in this work. Thermal simulations suggest that core temperature changes could occur in smaller subjects, although experimental data are needed for validation.


Subject(s)
Heating , Magnetic Resonance Imaging , Adolescent , Adult , Body Temperature , Child , Child, Preschool , Computer Simulation , Humans , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Radio Waves , Temperature
10.
Magn Reson Med ; 88(2): 817-831, 2022 08.
Article in English | MEDLINE | ID: mdl-35526212

ABSTRACT

PURPOSE: To develop a fully data-driven retrospective intrascan motion-correction framework for volumetric brain MRI at ultrahigh field (7 Tesla) that includes modeling of pose-dependent changes in polarizing magnetic (B0 ) fields. THEORY AND METHODS: Tissue susceptibility induces spatially varying B0 distributions in the head, which change with pose. A physics-inspired B0 model has been deployed to model the B0 variations in the head and was validated in vivo. This model is integrated into a forward parallel imaging model for imaging in the presence of motion. Our proposal minimizes the number of added parameters, enabling the developed framework to estimate dynamic B0 variations from appropriately acquired data without requiring navigators. The effect on data-driven motion correction is validated in simulations and in vivo. RESULTS: The applicability of the physics-inspired B0 model was confirmed in vivo. Simulations show the need to include the pose-dependent B0 fields in the reconstruction to improve motion-correction performance and the feasibility of estimating B0 evolution from the acquired data. The proposed motion and B0 correction showed improved image quality for strongly corrupted data at 7 Tesla in simulations and in vivo. CONCLUSION: We have developed a motion-correction framework that accounts for and estimates pose-dependent B0 fields. The method improves current state-of-the-art data-driven motion-correction techniques when B0 dependencies cannot be neglected. The use of a compact physics-inspired B0 model together with leveraging the parallel imaging encoding redundancy and previously proposed optimized sampling patterns enables a purely data-driven approach.


Subject(s)
Algorithms , Image Processing, Computer-Assisted , Artifacts , Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Retrospective Studies
11.
Magn Reson Med ; 88(1): 180-194, 2022 07.
Article in English | MEDLINE | ID: mdl-35266204

ABSTRACT

PURPOSE: This work proposes a novel RF pulse design for parallel transmit (pTx) systems to obtain uniform saturation of semisolid magnetization for magnetization transfer (MT) contrast in the presence of transmit field B1+ inhomogeneities. The semisolid magnetization is usually modeled as being purely longitudinal, with the applied B1+ field saturating but not rotating its magnetization; thus, standard pTx pulse design methods do not apply. THEORY AND METHODS: Pulse design for saturation homogeneity (PUSH) optimizes pTx RF pulses by considering uniformity of root-mean squared B1+ , B1rms , which relates to the rate of semisolid saturation. Here we considered designs consisting of a small number of spatially non-selective sub-pulses optimized over either a single 2D plane or 3D. Simulations and in vivo experiments on a 7T Terra system with an 8-TX Nova head coil in five subjects were carried out to study the homogenization of B1rms and of the MT contrast by acquiring MT ratio maps. RESULTS: Simulations and in vivo experiments showed up to six and two times more uniform B1rms compared to circular polarized (CP) mode for 2D and 3D optimizations, respectively. This translated into 4 and 1.25 times more uniform MT contrast, consistently for all subjects, where two sub-pulses were enough for the implementation and coil used. CONCLUSION: The proposed PUSH method obtains more uniform and higher MT contrast than CP mode within the same specific absorption rate (SAR) budget.


Subject(s)
Brain , Magnetic Resonance Imaging , Algorithms , Humans , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Radio Waves
12.
MAGMA ; 35(5): 765-778, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34997396

ABSTRACT

OBJECTIVE: Neonatal brain and cardiac imaging would benefit from the increased signal-to-noise ratio levels at 7 T compared to lower field. Optimal performance might be achieved using purpose designed RF coil arrays. In this study, we introduce an 8-channel dipole array and investigate, using simulations, its RF performances for neonatal applications at 7 T. METHODS: The 8-channel dipole array was designed and evaluated for neonatal brain/cardiac configurations in terms of SAR efficiency (ratio between transmit-field and maximum specific-absorption-rate level) using adjusted dielectric properties for neonate. A birdcage coil operating in circularly polarized mode was simulated for comparison. Validation of the simulation model was performed on phantom for the coil array. RESULTS: The 8-channel dipole array demonstrated up to 46% higher SAR efficiency levels compared to the birdcage coil in neonatal configurations, as the specific-absorption-rate levels were alleviated. An averaged normalized root-mean-square-error of 6.7% was found between measured and simulated transmit field maps on phantom. CONCLUSION: The 8-channel dipole array design integrated for neonatal brain and cardiac MR was successfully demonstrated, in simulation with coverage of the baby and increased SAR efficiency levels compared to the birdcage. We conclude that the 8Tx-dipole array promises safe operating procedures for MR imaging of neonatal brain and heart at 7 T.


Subject(s)
Electromagnetic Fields , Magnetic Resonance Imaging , Brain/diagnostic imaging , Equipment Design , Humans , Infant, Newborn , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Signal-To-Noise Ratio
13.
Magn Reson Med ; 87(1): 220-235, 2022 01.
Article in English | MEDLINE | ID: mdl-34418151

ABSTRACT

PURPOSE: Magnetization transfer (MT) and inhomogeneous MT (ihMT) contrasts are used in MRI to provide information about macromolecular tissue content. In particular, MT is sensitive to macromolecules, and ihMT appears to be specific to myelinated tissue. This study proposes a technique to characterize MT and ihMT properties from a single acquisition, producing both semiquantitative contrast ratios and quantitative parameter maps. THEORY AND METHODS: Building on previous work that uses multiband RF pulses to efficiently generate ihMT contrast, we propose a cyclic steady-state approach that cycles between multiband and single-band pulses to boost the achieved contrast. Resultant time-variable signals are reminiscent of an MR fingerprinting acquisition, except that the signal fluctuations are entirely mediated by MT effects. A dictionary-based low-rank inversion method is used to reconstruct the resulting images and to produce both semiquantitative MT ratio and ihMT ratio maps, as well as quantitative parameter estimates corresponding to an ihMT tissue model. RESULTS: Phantom and in vivo brain data acquired at 1.5 Tesla demonstrate the expected contrast trends, with ihMT ratio maps showing contrast more specific to white matter, as has been reported by others. Quantitative estimation of semisolid fraction and dipolar T1 was also possible and yielded measurements consistent with literature values in the brain. CONCLUSION: By cycling between multiband and single-band pulses, an entirely MT-mediated fingerprinting method was demonstrated. This proof-of-concept approach can be used to generate semiquantitative maps and quantitatively estimate some macromolecular-specific tissue parameters.


Subject(s)
Image Processing, Computer-Assisted , White Matter , Brain/diagnostic imaging , Magnetic Resonance Imaging , Myelin Sheath , White Matter/diagnostic imaging
14.
Magn Reson Med ; 86(6): 3360-3372, 2021 12.
Article in English | MEDLINE | ID: mdl-34286866

ABSTRACT

PURPOSE: We present in vivo testing of a parallel transmit system intended for interventional MR-guided cardiac procedures. METHODS: The parallel transmit system was connected in-line with a conventional 1.5 Tesla MRI system to transmit and receive on an 8-coil array. The system used a current sensor for real-time feedback to achieve real-time current control by determining coupling and null modes. Experiments were conducted on 4 Charmoise sheep weighing 33.9-45.0 kg with nitinol guidewires placed under X-ray fluoroscopy in the atrium or ventricle of the heart via the femoral vein. Heating tests were done in vivo and post-mortem with a high RF power imaging sequence using the coupling mode. Anatomical imaging was done using a combination of null modes optimized to produce a useable B1 field in the heart. RESULTS: Anatomical imaging produced cine images of the heart comparable in quality to imaging with the quad mode (all channels with the same amplitude and phase). Maximum observed temperature increases occurred when insulation was stripped from the wire tip. These were 4.1℃ and 0.4℃ for the coupling mode and null modes, respectively for the in vivo case; increasing to 6.0℃ and 1.3℃, respectively for the ex vivo case, because cooling from blood flow is removed. Heating < 0.1℃ was observed when insulation was not stripped from guidewire tips. In all tests, the parallel transmit system managed to reduce the temperature at the guidewire tip. CONCLUSION: We have demonstrated the first in vivo usage of an auxiliary parallel transmit system employing active feedback-based current control for interventional MRI with a conventional MRI scanner.


Subject(s)
Magnetic Resonance Imaging, Interventional , Animals , Equipment Design , Heart/diagnostic imaging , Magnetic Resonance Imaging , Phantoms, Imaging , Radio Waves , Sheep
15.
Phys Med Biol ; 66(15)2021 07 26.
Article in English | MEDLINE | ID: mdl-34192676

ABSTRACT

This study presents a comparison of quantitative MRI methods based on an efficiency metric that quantifies their intrinsic ability to extract information about tissue parameters. Under a regime of unbiased parameter estimates, an intrinsic efficiency metricηwas derived for fully-sampled experiments which can be used to both optimize and compare sequences. Here we optimize and compare several steady-state and transient gradient-echo based qMRI methods, such as magnetic resonance fingerprinting (MRF), for jointT1andT2mapping. The impact of undersampling was also evaluated, assuming incoherent aliasing that is treated as noise by parameter estimation.In vivovalidation of the efficiency metric was also performed. Transient methods such as MRF can be up to 3.5 times more efficient than steady-state methods, when spatial undersampling is ignored. If incoherent aliasing is treated as noise during least-squares parameter estimation, the efficiency is reduced in proportion to the SNR of the data, with reduction factors of 5 often seen for practical SNR levels.In vivovalidation showed a very good agreement between the theoretical and experimentally predicted efficiency. This work presents and validates an efficiency metric to optimize and compare the performance of qMRI methods. Transient methods were found to be intrinsically more efficient than steady-state methods, however the effect of spatial undersampling can significantly erode this advantage.


Subject(s)
Algorithms , Image Processing, Computer-Assisted , Brain , Magnetic Resonance Imaging , Phantoms, Imaging
16.
Magn Reson Med ; 86(3): 1299-1313, 2021 09.
Article in English | MEDLINE | ID: mdl-33811667

ABSTRACT

PURPOSE: To investigate safe limits for neonatal imaging using a 7T head coil, including both specific absorption rate (SAR) and temperature predictions. METHODS: Head-centered neonate models were simulated using finite-difference time domain-based electromagnetic and thermal solvers. The effects of higher water content of neonatal tissues compared with adults, position shifts, and thermal insulation were also considered. An adult model was simulated for comparison. RESULTS: Maximum and average SAR are both elevated in the neonate when compared with an adult model. When normalized to B1+ , the SAR experienced by a neonate is greater than an adult by approximately a factor of 2; when normalized to net forward power (forward-reflected), this increases to a factor of 2.5-3.0; and when normalized to absorbed power, approximately a factor of 4. Use of age-adjusted dielectric properties significantly increases the predicted SAR, compared with using adult tissue properties for the neonates. Thermal simulations predict that change in core temperature/maximum temperature remain compliant with International Electrotechnical Commission limits when a thermally insulated neonate is exposed at the SAR limit for up to an hour. CONCLUSION: This study of two neonate models cannot quantify the variability expected within a larger population. Likewise, the use of age-adjusted dielectric properties have a significant effect, but while their use is well motivated by literature, there is uncertainty in the true dielectric properties of neonatal tissue. Nevertheless, the main finding is that unlike at lower field strengths, operational limits for 7T neonatal MRI using an adult head coil should be more conservative than limits for use on adults.


Subject(s)
Head , Radio Waves , Adult , Computer Simulation , Head/diagnostic imaging , Humans , Infant, Newborn , Magnetic Resonance Imaging , Phantoms, Imaging , Temperature
17.
Magn Reson Med ; 86(1): 182-196, 2021 07.
Article in English | MEDLINE | ID: mdl-33586800

ABSTRACT

PURPOSE: A framework to design radiofrequency (RF) pulses specifically to minimize the TR of gradient echo sequences is presented, subject to hardware and physiological constraints. METHODS: Single-band and multiband (MB) RF pulses can be reduced in duration using variable-rate selective excitation (VERSE) VERSE for a range of flip angles; however, minimum-duration pulses do not guarantee minimum TR because these can lead to a high specific absorption rate (SAR). The optimal RF pulse is found by meeting spatial encoding, peripheral nerve stimulation (PNS) and SAR constraints. A TR reduction for a range of designs is achieved and an application of this in an MB cardiac balanced steady-state free-precession (bSSFP) experiment is presented. Gradient imperfections and their imaging effects are also considered. RESULTS: Sequence TR with low-time bandwidth product (TBP) pulses, as used in bSSFP, was reduced up to 14%, and the TR when using high TBP pulses, as used in slab-selective imaging, was reduced by up to 72%. A breath-hold cardiac exam was reduced by 46% using both MB and the TR-optimal framework. The importance of RF-based correction of gradient imperfections is demonstrated. PNS was not a practical limitation. CONCLUSION: The TR-optimal framework designs RF pulses for a range of pulse parameters, specifically to minimize sequence TR.


Subject(s)
Algorithms , Magnetic Resonance Imaging , Brain , Heart , Heart Rate , Phantoms, Imaging , Radio Waves
18.
Magn Reson Med ; 85(4): 2069-2083, 2021 04.
Article in English | MEDLINE | ID: mdl-33201524

ABSTRACT

PURPOSE: To develop a novel gadolinium-free model-based quantitative magnetization transfer (qMT) technique to assess macromolecular changes associated with myocardial fibrosis. METHODS: The proposed sequence consists of a two-dimensional breath-held dual shot interleaved acquisition of five MT-weighted (MTw) spoiled gradient echo images, with variable MT flip angles (FAs) and off-resonance frequencies. A two-pool exchange model and dictionary matching were used to quantify the pool size ratio (PSR) and bound pool T2 relaxation ( T2B ). The signal model was developed and validated using 25 MTw images on a bovine serum albumin (BSA) phantom and in vivo human thigh muscle. A protocol with five MTw images was optimized for single breath-hold cardiac qMT imaging. The proposed sequence was tested in 10 healthy subjects and 5 patients with myocardial fibrosis and compared to late gadolinium enhancement (LGE). RESULTS: PSR values in the BSA phantom were within the confidence interval of previously reported values (concentration 10% BSA = 5.9 ± 0.1%, 15% BSA = 9.4 ± 0.2%). PSR and T2B in thigh muscle were also in agreement with literature (PSR = 10.9 ± 0.3%, T2B = 6.4 ± 0.4 us). In 10 healthy subjects, global left ventricular PSR was 4.30 ± 0.65%. In patients, PSR was reduced in areas associated with LGE (remote: 4.68 ± 0.70% vs. fibrotic: 3.12 ± 0.78 %, n = 5, P < .002). CONCLUSION: In vivo model-based qMT mapping of the heart was performed for the first time, with promising results for non-contrast enhanced assessment of myocardial fibrosis.


Subject(s)
Cardiomyopathies , Contrast Media , Cardiomyopathies/diagnostic imaging , Fibrosis , Gadolinium , Humans , Magnetic Resonance Imaging
20.
Nat Commun ; 11(1): 4992, 2020 10 05.
Article in English | MEDLINE | ID: mdl-33020487

ABSTRACT

Prenatal detection of congenital heart disease facilitates the opportunity for potentially life-saving care immediately after the baby is born. Echocardiography is routinely used for screening of morphological malformations, but functional measurements of blood flow are scarcely used in fetal echocardiography due to technical assumptions and issues of reliability. Magnetic resonance imaging (MRI) is readily used for quantification of abnormal blood flow in adult hearts, however, existing in utero approaches are compromised by spontaneous fetal motion. Here, we present and validate a novel method of MRI velocity-encoding combined with a motion-robust reconstruction framework for four-dimensional visualization and quantification of blood flow in the human fetal heart and major vessels. We demonstrate simultaneous 4D visualization of the anatomy and circulation, which we use to quantify flow rates through various major vessels. The framework introduced here could enable new clinical opportunities for assessment of the fetal cardiovascular system in both health and disease.


Subject(s)
Fetal Heart/diagnostic imaging , Fetal Heart/physiology , Four-Dimensional Computed Tomography/methods , Magnetic Resonance Imaging, Cine/methods , Blood Flow Velocity , Blood Vessels/diagnostic imaging , Blood Vessels/physiology , Female , Gestational Age , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/physiopathology , Humans , Phantoms, Imaging , Pregnancy , Prenatal Diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...