Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Sci Rep ; 14(1): 11120, 2024 05 15.
Article in English | MEDLINE | ID: mdl-38750131

ABSTRACT

Very High Energy Electron (VHEE) beams are a promising alternative to conventional radiotherapy due to their highly penetrating nature and their applicability as a modality for FLASH (ultra-high dose-rate) radiotherapy. The dose distributions due to VHEE need to be optimised; one option is through the use of quadrupole magnets to focus the beam, reducing the dose to healthy tissue and allowing for targeted dose delivery at conventional or FLASH dose-rates. This paper presents an in depth exploration of the focusing achievable at the current CLEAR (CERN Linear Electron Accelerator for Research) facility, for beam energies >200 MeV. A shorter, more optimal quadrupole setup was also investigated using the TOPAS code in Monte Carlo simulations, with dimensions and beam parameters more appropriate to a clinical situation. This work provides insight into how a focused VHEE radiotherapy beam delivery system might be achieved.


Subject(s)
Electrons , Monte Carlo Method , Radiotherapy Dosage , Humans , Particle Accelerators/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy/methods , Radiotherapy, High-Energy/methods , Radiotherapy, High-Energy/instrumentation
2.
Phys Rev Lett ; 123(23): 234801, 2019 Dec 06.
Article in English | MEDLINE | ID: mdl-31868471

ABSTRACT

The transverse emittance of the electron beam is a fundamental parameter in linac-based x-ray free-electron lasers (FELs). We present results of emittance measurements carried out at SwissFEL, a compact x-ray FEL facility at the Paul Scherrer Institute in Switzerland, including a description of the novel high-resolution measurement techniques and the optimization procedure. We obtained slice emittance values at the undulator entrance down to 200 nm for an electron beam with a charge of 200 pC and an rms duration of 30-40 fs. Furthermore, we achieved slice emittances as low as 100 nm for 10 pC beams with few fs duration. These values set new standards for electron linear accelerators. The quality, verification, and control of our electron beams allowed us to generate high-power FEL radiation for a wavelength as short as 0.1 nm using an electron beam with an energy of only 6 GeV. The emittance values demonstrated at SwissFEL would allow producing hard x-ray FEL pulses with even lower-energy beams, thus paving the way for even more compact and cost-effective FEL facilities.

SELECTION OF CITATIONS
SEARCH DETAIL