Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
2.
J Interv Card Electrophysiol ; 67(1): 61-69, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37178189

ABSTRACT

BACKGROUND: Pulmonary vein isolation by cryoablation (PVI-C) is a standard therapy for the treatment of patients with symptomatic atrial fibrillation (AF). AF symptoms are highly subjective; however, they are important outcomes for the patient. The aim is to describe the use and impact of a web-based App to collect AF-related symptoms in a population of patients who underwent PVI-C in seven Italian centers. METHODS: A patient App to collect AF-related symptoms and general health status was proposed to all patients who underwent an index PVI-C. Patients were divided into two groups according to the utilization of the App or the non-usage. RESULTS: Out of 865 patients, 353 (41%) subjects composed the App group, and 512 (59%) composed the No-App group. Baseline characteristics were comparable between the two cohorts except for age, sex, type of AF, and body mass index. During a mean follow-up of 7.9±13.8 months, AF recurrence was found in 57/865 (7%) subjects with an annual rate of 7.36% (95% CI:5.67-9.55%) in the No-App versus 10.99% (95% CI:9.67-12.48%) in the App group, p=0.007. In total, 14,458 diaries were sent by the 353 subjects in the App group and 77.1% reported a good health status and no symptoms. In only 518 diaries (3.6%), the patients reported a bad health status, and bad health status was an independent parameter of AF recurrence during follow-up. CONCLUSIONS: The use of a web App to record AF-related symptoms was feasible and effective. Additionally, a bad health status reporting in the App was associated with AF recurrence during follow-up.


Subject(s)
Atrial Fibrillation , COVID-19 , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Treatment Outcome , Cryosurgery/adverse effects , Pulmonary Veins/surgery , Recurrence , Catheter Ablation/adverse effects
3.
J Interv Card Electrophysiol ; 67(3): 609-616, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37697222

ABSTRACT

BACKGROUND: The aims of this analysis were: to evaluate the impact of timing of ablation on the rate of atrial arrhythmias recurrence, verify if the timing of ablation impact differently in patients with paroxysmal and persistent AF. METHODS: Three thousand two hundred and five patients (60.5 ± 10 years, female 28.4%%, 78.8%% paroxysmal AF) were included in the analysis. All patients underwent only cryoballoon (CB) pulmonary vein (PV) isolation during the index procedure. RESULTS: The mean procedure time was 102.8 ± 50 min, with a mean fluoroscopy time of 26.3 ± 49 min. Acute PV isolation was achieved in 11760/11793 (99.7%) PVs. A total of 91 (2.8%) patients experienced a procedure-related complication. During the observation period 913/3205 (28.5%) patients had at least one atrial arrhythmias episode: 28% of patients with paroxysmal AF vs 33% of patients with persistent AF. In multivariate analysis, persistent AF together with time from symptomatic AF diagnosis to ablation, female sex, and ablation time showed to be significant predictors for AF recurrence. In particular, months from first symptomatic AF episode > 18 months was a significant predictor of AF recurrence (HR = 1.23, 95% CI = 1.03-1.46, p = 0.020). In patients with paroxysmal AF, the multivariate analysis confirmed that months from first symptomatic AF episode > 18 month was an independent predictor of AF recurrence together with age > 62 years and female sex. In patients with persistent AF, the time from persistent AF showed to be significant predictor for AF recurrence. CONCLUSIONS: In this multicenter analysis, time from first symptomatic AF episode > 18 months was a significant predictor of AF recurrence after CB PV isolation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Female , Middle Aged , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Treatment Outcome , Pulmonary Veins/surgery , Cryosurgery/methods , Time Factors , Catheter Ablation/methods , Recurrence
4.
J Interv Card Electrophysiol ; 66(5): 1193-1200, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36417124

ABSTRACT

BACKGROUND: Pulmonary vein isolation by cryoablation (PVI-C) is a standard therapy for the treatment of atrial fibrillation (AF). The CHA2DS2-VASc score is a well-established predictor of AF-related stroke. Whether the CHA2DS2-VASc score can also be useful in predicting the long-term clinical outcomes following PVI-C is still unsettled. The aim of this analysis was to evaluate the role of the CHA2DS2-VASc score in predicting AF recurrence after PVI-C. METHODS: Patients with symptomatic AF underwent an index PVI-C. Data were collected prospectively in the framework of the 1STOP ClinicalService project. Patients were categorized into two groups: low risk (LR) and high risk (HR) based on CHA2DS2-VASc score (0-1 and ≥ 2, respectively). RESULTS: Out of 3313 patients, 1910 (57.6%) had a CHA2DS2-VASc score between 0 and 1, while 1403 (42.3%) had CHA2DS2-VASc > = 2. Patient characteristics were significantly different between the two cohorts, including age, sex, BMI, paroxysmal AF, history of stroke, diabetes, and ischemic cardiomyopathy. On the contrary, procedural times and acute complications were comparable. The 36-month freedom from AF after a single procedure was 72.5% (95% CI: 69.8-75.0) in the LR group and 65.9% (95% CI: 62.3-69.2) in the HR score group (HR: 1.26, 95% CI: 1.08-1.47, p = 0.001). After multivariate analysis, higher CHA2DS2-VASc score was still a significant predictor of the risk of AF recurrence (HR: 1.33; 1.10-1.60, p = 0.003). CONCLUSIONS: PVI-C is highly effective in the treatment of AF over the long term. A CHA2DS2-VASc score ≥ 2 is an independent predictor of AF recurrence during the follow-up and should be considered during the clinical management after the index procedure.


Subject(s)
Atrial Fibrillation , Cryosurgery , Pulmonary Veins , Stroke , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Pulmonary Veins/surgery , Risk Factors , Cryosurgery/methods , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Risk Assessment/methods , Recurrence
5.
Clin Cardiol ; 46(2): 142-150, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36448243

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is an uncommon arrhythmia in young adults without structural heart disease, and cryoballoon pulmonary vein isolation (CB-PVI) is an important therapeutic strategy for rhythm control in patients with drug-refractory AF. The aim of this analysis was to evaluate efficacy and safety of CB-PVI in a large cohort of young patients in comparison with middle-aged adults in a real-world setting. METHODS: From 2012 to 2020, a total of 3033 patients with AF underwent CB-PVI and were followed prospectively in the framework of the 1STOP Clinical Service project, involving 34 Italian centers. Out of 3033 total 1STOP project subjects, a subgroup of 1318 patients were defined which included a YOUNG group (age ≤ 45 years; n = 368) and a MIDDLE-AGED group (age 60-65 years; n = 950). RESULTS: The acute success rate of PVI did not differ between the two cohorts (99.9 ± 1.3% vs. 99.8 ± 3.2%, p = 0.415). There was no difference in procedural characteristics, and periprocedural complication rates were similar among the two cohort (1.9% vs. 2.3%, p = 0.646). The 12-month freedom from AF recurrence was 88.9% (95% confidence interval [CI]: 84.7-92.0) in the YOUNG cohort and 85.6% (95% CI: 82.9-88.0) in the MIDDLE-AGED group. At 36-month follow-up, freedom from AF recurrence was 72.4% (65.5%-78.2%) and 71.8% (67.7%-75.6%), respectively with no significant difference among groups (p = 0.550). CONCLUSION: CB-PVI had similar efficacy and safety in YOUNG and MIDDLE-AGED patients. Younger age did not affect acute procedural results, complication rate, or AF recurrence after a single procedure.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Heart Diseases , Pulmonary Veins , Middle Aged , Young Adult , Humans , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Cryosurgery/methods , Treatment Outcome , Recurrence , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods
6.
J Electrocardiol ; 75: 36-43, 2022.
Article in English | MEDLINE | ID: mdl-36274327

ABSTRACT

BACKGROUND: A better selection of patients with left bundle branch block (LBBB) might increase the response to cardiac resynchronization therapy (CRT). The aim of the study was to investigate the association between the Strauss criteria, absence of S wave in V5-V6, the Selvester score and response to CRT. METHODS AND RESULTS: The retrospective analysis included all consecutive patients having undergone implantation of biventricular defibrillators in primary prevention between 2018 and 2020. The final analysis included 236 patients (mean age 69.7 ± 9.9; 77.5% of males). The Strauss criteria were significantly associated with CRT response (p < 0.01) with a sensitivity of 71.3% and specificity of 64.1%. The Strauss criteria along with the absence of S wave in V5 and V6 showed a sensitivity of 56.7%, a specificity of 82.6% and a positive predictive value of 90.5%. The Selvester score was significantly and inversely associated with CRT response (OR 0.818, 95% CI 0.75-0.89; p < 0.001). The multivariable model showed that left ventricular ejection fraction (LVEF) and QRS duration (≥140 ms in males and ≥ 130 ms in females) were independently associated with CRT response (respectively OR 0.92, CI 95% 0.86-0.98, p = 0.01 and OR 3.70, CI 95% 1.12-12.21, p = 0.03). CONCLUSIONS: Strauss criteria, especially in association with absence of S wave in V5 and V6, were able to increase specificity and positive predictive value for predicting CRT response. The Selvester score was inversely associated with CRT response. Finally, LVEF and QRS duration were independently associated with echocardiographic response to CRT.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Male , Female , Humans , Middle Aged , Aged , Cardiac Resynchronization Therapy/methods , Electrocardiography/methods , Stroke Volume , Retrospective Studies , Ventricular Function, Left/physiology , Heart Failure/diagnosis , Heart Failure/therapy , Echocardiography , Treatment Outcome
7.
J Cardiovasc Dev Dis ; 9(5)2022 Apr 21.
Article in English | MEDLINE | ID: mdl-35621837

ABSTRACT

The aim of this research was to evaluate if patients with chronic kidney disease (CKD) and mild or mild to moderate depression of renal function have an increased risk of atrial fibrillation (AF) recurrences after cryoballoon (CB) ablation. We performed a retrospective analysis of AF patients undergoing pulmonary vein isolation (PVI) by CB. The cohort was divided according to the KDIGO CKD-EPI classification into a (1) normal, (2) mildly decreased, or (3) mild to moderate reduction in estimated glomerular filtration rate (eGFR). Freedom from AF recurrences was the primary endpoint. A total of 1971 patients were included (60 ± 10 years, 29.0% females, 73.6% paroxysmal AF) in the study. Acute success and complication rates were 99.2% and 3.7%, respectively, with no significant differences among the three groups. After a follow-up of 24 months, AF recurrences were higher in the mildly and mild to moderate CKD groups compared to the normal kidney function group (23.4% vs. 28.3% vs. 33.5%, p < 0.05). Mild to moderate CKD was an independent predictor of AF recurrences after the blanking period (hazard ratio:1.38, 95% CI 1.02−1.86, p = 0.037). In conclusion, a multicenter analysis of AF patients treated with cryoablation revealed mild to moderate reductions in renal functions were associated with a higher risk of AF recurrences. Conversely, the procedural success and complication rates were similar in patients with normal, mildly reduced, or mild to moderate reduction in eGFR.

8.
Pacing Clin Electrophysiol ; 45(8): 968-974, 2022 08.
Article in English | MEDLINE | ID: mdl-35417055

ABSTRACT

BACKGROUND: It has been observed that the fourth-generation cryoballoon (CB4) ablation catheter increased the rate of acute real-time recordings of pulmonary vein isolation (PVI) during the ablation for the treatment of atrial fibrillation (AF). The aim of this analysis was to compare the long-term outcome results between patients treated with the CB4 and second-generation cryoballoon (CB2). METHODS: In total, 492 patients suffering from AF, underwent PVI ablation with either the CB2 or CB4 catheter within this examination of the 1STOP real-world Italian project and were included in the analysis. Specifically, 246 consecutive patients treated by CB4 were compared to 246 propensity-matched control patients who underwent PVI using CB2. RESULTS: When comparing the patient cohorts treated with CB2 versus CB4, acute success rate (99.6 ± 4.7% vs. 99.7 ± 3.6%, p = .949) and peri-procedural complications (3.7% vs.1.2%, p = .080) were similar in both groups, respectively. However, procedure time (100 vs.75 min, p < .001) and fluoroscopy duration (21 vs.17 min, p < .001) were all significantly lower in the CB4 treated patient cohort. At the 12-month follow-up, the freedom from AF recurrence after a 90-day blanking period was significant higher in the CB4 as compared with the CB2 group (93.3% vs.81.3%, p < .001). CONCLUSIONS: In summary, usage of the CB4 ablation catheter increased the rate of acute PVI recording capability and resulted in a higher rate of long-term PVI success, as demonstrated by the reduced rate of AF recurrence in comparison to the CB2 cohort at the 12-month follow-up period.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Catheter Ablation/methods , Catheters , Cryosurgery/methods , Humans , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
9.
Minerva Cardiol Angiol ; 70(5): 529-536, 2022 10.
Article in English | MEDLINE | ID: mdl-33258567

ABSTRACT

BACKGROUND: The clinical role of left atrial hypertension (LAH) in patients with atrial fibrillation (AF) and its role as predictor in those undergoing pulmonary vein (PV) isolation is still unknown. The aim of the present study was to analyse the prevalence of LAH in patients with nonvalvular AF and preserved left ventricular ejection fraction who underwent PV isolation and its implication for AF catheter ablation. METHODS: Consecutive patients with drug resistant AF who underwent PV isolation at San Maurizio Regional Hospital of Bolzano (Italy) as index procedure were retrospectively included in this analysis. Left atrial hypertension was defined as the LA mean pressure ≥15 mmHg. RESULTS: A total of 98 consecutive patients (71 males, 72%; mean age 60.3±8.4 years) were included in the analysis. Eleven patients (11%) underwent radiofrequency ablation and 87 (89%) cryoballoon ablation. The mean LA pressure was 11.7±5.5 mmHg; LAH occurred in 24 (24.5%) patients. At a mean follow-up of 14.6±7.1 months (median 14 months), the success rate without antiarrhythmic therapy was 71.4% (70/98; considering the blanking period). Older age, LA volume and LAH were significantly associated with early AF recurrence during the blanking period. However, only LAH independently remained a significant predictor of late AF recurrence (HR 3.02, 1.36-6.72, P=0.007). CONCLUSIONS: Left atrial hypertension was found in 24% of patients undergoing PV isolation and was found to be significantly related to both early and late AF recurrences.


Subject(s)
Atrial Fibrillation , Hypertension , Pulmonary Veins , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Humans , Hypertension/epidemiology , Hypertension/etiology , Male , Middle Aged , Pulmonary Veins/surgery , Retrospective Studies , Stroke Volume , Ventricular Function, Left
10.
J Am Heart Assoc ; 10(22): e021861, 2021 11 16.
Article in English | MEDLINE | ID: mdl-34779249

ABSTRACT

Background Sudden cardiac arrest (SCA) may be caused by an acute and reversible myocardial injury, a chronic and irreversible myocardial damage, or a primary ventricular arrhythmia. Cardiac magnetic resonance imaging may identify myocardial edema (ME), which denotes acute and reversible myocardial damage. We evaluated the arrhythmic outcome of SCA survivors during follow-up and tested the prognostic role of ME. Methods and Results We included a consecutive series of 101 (71% men, median age 47 years) SCA survivors from 9 collaborative centers who underwent early (<1 month) cardiac magnetic resonance imaging and received an implantable cardioverter-defibrillator (ICD). On T2-weighted sequences, ME was found in 18 of 101 (18%) patients. According to cardiac magnetic resonance imaging findings, the arrhythmic SCA was ascribed to acute myocardial injury (either ischemic [n=10] or inflammatory [n=8]), to chronic structural heart diseases (ischemic heart disease [n=11], cardiomyopathy [n=20], or other [n=23]), or to primarily arrhythmic syndrome (n=29). During a follow-up of 47 months (28 to 67 months), 24 of 101 (24%) patients received an appropriate ICD intervention. ME was associated with a significantly higher survival free from both any ICD interventions (log-rank=0.04) and ICD shocks (log-rank=0.03) and remained an independent predictor of better arrhythmic outcome after adjustment for left ventricular ejection fraction and late gadolinium enhancement. The risk of appropriate ICD intervention was unrelated to the type of underlying heart disease. Conclusions ME on early cardiac magnetic resonance imaging, which denotes an acute and transient arrhythmogenic substrate, predicted a favorable long-term arrhythmic outcome of SCA survivors. These findings may have a substantial impact on future guidelines on the management of SCA survivors.


Subject(s)
Defibrillators, Implantable , Out-of-Hospital Cardiac Arrest , Arrhythmias, Cardiac/diagnostic imaging , Arrhythmias, Cardiac/therapy , Contrast Media , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Edema , Female , Gadolinium , Humans , Magnetic Resonance Imaging , Magnetic Resonance Imaging, Cine , Magnetic Resonance Spectroscopy , Male , Middle Aged , Prognosis , Risk Factors , Stroke Volume , Survivors , Ventricular Function, Left
11.
J Clin Med ; 10(15)2021 Jul 21.
Article in English | MEDLINE | ID: mdl-34361991

ABSTRACT

AIMS: The clinical role of the left atrial (LA) hypertension in patients with atrial fibrillation (AF) and its role as predictor in those undergoing pulmonary vein (PV) isolation is still unknown. The aim of the present study was to analyze the role of LA pressure in patients with nonvalvular AF who underwent PV isolation and its implication for AF catheter ablation. METHODS: Consecutive patients with drug resistant AF who underwent PV isolation at San Maurizio Regional Hospital of Bolzano (Italy) as index procedure were included in this analysis. RESULTS: A total of 132 consecutive patients (97 males, 73%; mean age 58.0 ± 13.2 years) were included in the analysis. Eleven patients (8%) underwent radiofrequency ablation and 121 (92%) cryoballoon ablation. Higher LA pressures were found in 54 patients (40.9%). At a mean follow up of 14.3 ± 8.2 months (median 12 months), the success rate without antiarrhythmic therapy was 65.9% (87/132; considering the blanking period). Female gender and continuous mean LA pressure were significantly associated with AF recurrence and remained significant on multivariable Cox analysis (respectively, HR 1.845, 1.00-3.40, p = 0.05 and HR 1.066, 1.002-1.134, p = 0.04). We identified a LA mean pressure of >15 mmHg as ideal cutoff and constructed a model to predict AF recurrence which fitted with a concordance index (C-index) of 0.65 (95% CI 0.56-0.75), logrank score p = 0.003.

12.
J Cardiovasc Med (Hagerstown) ; 22(8): 618-623, 2021 08 01.
Article in English | MEDLINE | ID: mdl-34009837

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) using cryoballoon ablation (CBA) is mainly reserved for patients with drug-refractory or drug-intolerant symptomatic atrial fibrillation. We evaluated a large cohort of patients treated in a real-world setting and examined the safety and efficacy profile of CBA when applied as a first-line treatment for atrial fibrillation. METHODS: In total, 249 patients (23% women; 56 ±â€Š13 years; mean left atrial diameter 41 ±â€Š7 mm; 73.5% paroxysmal atrial fibrillation; and 26.5% persistent atrial fibrillation) underwent an index PVI by CBA. Data were collected prospectively in the framework of the 1STOP ClinicalService project, involving 26 Italian cardiology centers. RESULTS: Median procedure and fluoroscopy times were 90.0 and 21.0 min, respectively. Acute procedural success was 99.8%. Acute/periprocedural complications were observed in seven patients (2.8%), including: four transient diaphragmatic paralyses, one pericardial effusion (not requiring any intervention), one transient ischemic attack, and one minor vascular complication. The Kaplan--Meier freedom from atrial fibrillation recurrence was 86.3% at 12 months and 76% at 24 months. Seventeen patients (6.8%) had a repeat catheter ablation procedure during the follow-up period. At last follow-up, 10% of patients were on an anticoagulation therapy, whereas 6.8% were on an antiarrhythmic drug. CONCLUSION: In our multicenter real-world experience, PVI by CBA in a first-line atrial fibrillation patient population was well tolerated, effective, and promising. CBA with a PVI strategy can be used to treat patients with paroxysmal and persistent atrial fibrillation with good acute procedural success, short procedure times, and acceptable safety. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov (NCT01007474).


Subject(s)
Atrial Fibrillation , Cryosurgery , Postoperative Complications , Secondary Prevention/statistics & numerical data , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Catheter Ablation/methods , Catheter Ablation/statistics & numerical data , Cryosurgery/adverse effects , Cryosurgery/methods , Female , Humans , Male , Middle Aged , Operative Time , Outcome and Process Assessment, Health Care , Patient Safety , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Prospective Studies , Pulmonary Veins/surgery , Radiologic Health
13.
Cardiol Res Pract ; 2021: 9996047, 2021.
Article in English | MEDLINE | ID: mdl-34992884

ABSTRACT

BACKGROUND: The real-world efficacy and safety of atrial fibrillation (AF) ablation in particularly young and elderly patients are still under debate. The aim of the analysis was to investigate the effect of age on the efficacy and safety of cryoballoon ablation (CBA). METHODS: 2,534 patients underwent pulmonary vein isolation (PVI) by way of CBA for paroxysmal or persistent drug-resistant and symptomatic AF. The population was divided into age quartiles for evaluation, including (1) <53 years, (2) ≥53 and <61 years, (3) ≥61 and <67 years, and (4) ≥67 years. Furthermore, outcomes were analyzed in patients <41 years, ≥41 and ≤74, and >74 years old. Procedural data and complications were collected, and atrial fibrillation recurrences were evaluated during follow-up. RESULTS: Procedural-related complications (4.1%) were similar in the four subgroups according to age. At the 12-month follow-up, freedom from AF recurrence was 79.2%, 77.4%, 76.8%, and 75.2% (p=0.21), respectively (with increasing age). At 24-month follow-up, similar incidences of AF recurrence were observed in the four subgroups. When the sample was arbitrarily divided into the three age groups, a higher rate of recurrence was observed in older patients with regard to long-term follow-up (freedom from AF recurrence was 71.8% and 40.9%, respectively, at 12 and 24-month follow-up). In the univariate and multivariate analysis, age did not result in a significant predictor of AF recurrence during follow-up; however, a trend toward higher AF recurrences rates in patients ≥67 years was observed. CONCLUSION: The data demonstrated a high degree of safety during CBA across all patient ages. Procedural performance and complications were similar between different ages; AF recurrences seem to be more frequent in patients over 74 years.

14.
Pacing Clin Electrophysiol ; 44(2): 306-317, 2021 02.
Article in English | MEDLINE | ID: mdl-33372267

ABSTRACT

BACKGROUND: Pulmonary veins isolation (PVI) by cryoballoon (CB) ablation is marginally represented in clinical studies in obese patients. The aim of this analysis was to evaluate the safety and efficacy of CB-PVI in a large cohort of overweight and obese patients from the 1STOP project. METHODS: From 2012 to 2018, 2048 patients with atrial fibrillation (AF) (70% male, 59 ± 11 years; 75% paroxysmal AF) underwent index CB-PVI. The patient data were separated into three cohorts for statistical evaluation, including: normal weight (body mass index [BMI] < 25 kg/m2 ), overweight (BMI = 25-30 kg/m2 ), and obese patients (BMI > 30 kg/m2 ). RESULTS: Out of 2048 patients, 693 (34%) patients had a BMI < 25 and were deemed as normal. There were 944 (46%) patients categorized as overweight (BMI = 25-30) and 411 (20%) as obese (BMI > 30). Overweight or obese patients were more often in persistent AF, had more frequently hypertension and diabetes, had higher CHA2 DS2 -VASc score, and had a number of failed antiarrhythmic drug (AAD). Periprocedural complication rates were similar among the three cohorts. The 12-month freedom from AF recurrence was 76.4% in the normal BMI group as compared to 79.2% in the overweight and 73.5% in the obese group (p = .35). However, 48% of overweight patients were on AAD treatment during the follow-up. By multivariate analysis, BMI was not a predictor for AF recurrence following the index CB-PVI. CONCLUSION: CB-PVI in obese patients is a safe procedure. Increased BMI (either moderate or severe) does not seem to be associated with a worse outcome or to a different rate of AAD discontinuation at 12 months.


Subject(s)
Atrial Fibrillation/complications , Atrial Fibrillation/surgery , Cryosurgery , Obesity/complications , Pulmonary Veins/surgery , Aged , Cryosurgery/adverse effects , Female , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome
15.
Europace ; 22(12): 1798-1804, 2020 12 23.
Article in English | MEDLINE | ID: mdl-33006599

ABSTRACT

AIMS: The aims of this study were to determine the rate and the predictors of early recurrences of atrial fibrillation (ERAF) after cryoballoon (CB) ablation and to evaluate whether ERAF correlate with the long-term outcome. METHODS AND RESULTS: Three thousand, six hundred, and eighty-one consecutive patients (59.9 ± 10.5 years, female 26.5%, and 74.3% paroxysmal AF) were included in the analysis. Atrial fibrillation recurrence, lasting at least 30 s, was collected during and after the 3-month blanking period. Three-hundred and sixteen patients (8.6%) (Group A) had ERAF during the blanking period, and 3365 patients (Group B) had no ERAF. Persistent AF and number of tested anti-arrhythmic drugs ≥2 resulted as significant predictors of ERAF. After a mean follow-up of 16.8 ± 16.4 months, 923/3681 (25%) patients had at least one AF recurrence. The observed freedom from AF recurrence, at 24-month follow-up from procedure, was 25.7% and 64.8% in Groups A and B, respectively (P < 0.001). ERAF, persistent AF, and number of tested anti-arrhythmic drugs ≥2 resulted as significant predictors of AF. In a propensity score matching, the logistic model showed that ERAF 1 month after ablation are the best predictor of long-term AF recurrence (P = 0.042). CONCLUSION: In patients undergoing CB ablation for AF, ERAF are rare and are a strong predictor of AF recurrence in the follow-up, above all when occur >30 days after the ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Cryosurgery/adverse effects , Female , Humans , Pulmonary Veins/surgery , Recurrence , Time Factors , Treatment Outcome
16.
Heart Lung Circ ; 29(7): 1078-1086, 2020 Jul.
Article in English | MEDLINE | ID: mdl-31594723

ABSTRACT

BACKGROUND: Pulmonary vein isolation (PVI) is the most widely adopted strategy for paroxysmal atrial fibrillation (PAF) ablation. Limited evidence on acute results and late outcomes of cryoballoon (CB)-PVI in patients with structural heart disease (SHD) exist. The aim of this analysis was to compare acute procedural results and the 1-year recurrence rate of a single CB-PVI procedure in a PAF population with and without SHD. METHOD: From April 2012 to May 2017, a total of 2,031 patients with AF underwent CB-PVI and were followed prospectively in the framework of the One Shot TO Pulmonary vein isolation (1STOP) ClinicalService project, involving 36 Italian cardiology centres. We identified patients with SHD according to criteria proposed by current ESC guidelines: left ventricular (LV) systolic or diastolic dysfunction, long-standing hypertension with LV hypertrophy, and/or other structural heart disease. Data on procedural outcomes and long-term freedom from AF recurrence were evaluated. RESULTS: Our population consisted of 1,452 patients, of whom 282 (19.4%) were classified as having SHD. Compared to non-SHD patients, the SHD cohort was older (mean ± standard deviation, 62.9 ± 9.0 vs 58.2 ± 11.4 years; p < 0.001), was more frequently male (79.1% vs 69.8%; p < 0.002), had a higher thrombo-embolic risk (CHA2DS2VASc ≥2: 63.4% vs 40.2%; p < 0.001), had a higher body mass index (27.7 ± 3.9 vs 26.4 ± 3.9 kg/m2; p < 0.001), had a larger atrial diameter (43.8 ± 7.0 vs 40.2 ± 5.8 mm; p < 0.001), and had a lower LV ejection fraction (57.2 ± 7.7% vs 60.7 ± 6.0%; p < 0.001). At the time of ablation, 73% of patients were on class Ic or III anti-arrhythmic drugs. Procedure time (106.9 ± 41.5 vs 112.1 ± 46.8 min; p = 0.248), fluoroscopic time (28.7 ± 14.7 vs 28.6 ± 15.2 min; p = 0.819), and complication rate (3.9% vs 4.8%; p = 0.525) were not different between the SHD and non-SHD cohorts. However, the acute success rate (98.9% vs 97.7%; p = 0.016) was higher in patients with SHD. After a follow-up of 13.4 ± 12.8 months, freedom from symptomatic recurrence was 78.0% for SHD and 78.4% for non-SHD (p = 0.895). Recurrence rate was not related to either left atrial size or LVEF. In the SHD cohort, Class Ic or III anti-arrhythmic drugs treatment decreased from 70.7% of patients before ablation to 28.7% of patients after CB-PVI (p = 0.001). CONCLUSIONS: CB-PVI was extensively applied to treat patients with PAF. Unlike previous PVI experiences, the acute success and recurrence rate after a single procedure was not related to the presence of SHD or to the degree of cardiac remodelling. Further studies are required to define whether CB-PVI has a useful role in patients with a significantly reduced ejection fraction as those patients were under-represented in the current population.


Subject(s)
Ablation Techniques/methods , Atrial Fibrillation/surgery , Cryosurgery/methods , Heart Conduction System/physiopathology , Tachycardia, Paroxysmal/surgery , Ventricular Function, Left/physiology , Atrial Fibrillation/physiopathology , Female , Follow-Up Studies , Heart Conduction System/surgery , Humans , Male , Middle Aged , Prospective Studies , Recurrence , Tachycardia, Paroxysmal/physiopathology , Treatment Outcome
17.
J Cardiovasc Electrophysiol ; 31(1): 80-88, 2020 01.
Article in English | MEDLINE | ID: mdl-31701569

ABSTRACT

INTRODUCTION: Four generations of the cryoballoon (CB) catheter were retrospectively evaluated in a real-world examination of patients with atrial fibrillation (AF). METHODS AND RESULTS: Four hundred eighty patients (27% female and 60 ± 10 years) suffering from AF, underwent pulmonary vein (PV) ablation with one-of-four generations of the CB catheter. The total cohort was divided into four groups of patients: 120 with first-generation (CB-1); 120 with second-generation (CB-2); 120 with third-generation (CB-3); and 120 with fourth-generation (CB-4). Equal group sizes were achieved by examining the last 120 patients treated in each cohort, attempting to minimize the effect of a learning curve between the generations of CB catheter. Baseline clinical and patient characteristics were similar between the four cohorts, excepting age and the number of tested antiarrhythmic drugs. Procedure, fluoroscopy, and left atrial dwell times were significantly lower in the CB-4 cohort compared to previous generations of the CB catheters, while the acute procedural success rate was comparable across all catheter groups (>99%). Total acute procedural complications were low (2.5%), and acute complications were comparable within the CB-2, CB-3, and CB-4 groups (0.8% reported in each cohort). The rate of time-to-isolation (TTI) visualization increased with later generations of the CB catheters. CONCLUSIONS: The novel CB-4 achieved significantly faster procedural ablation times in comparison to the previous generations, while still maintaining a low rate of acute complications. Also, the rate of TTI visualization was observed to be higher with the CB-4 catheter. Further long-term evaluation is necessary, including an assessment of AF recurrence and PV reconnection(s).


Subject(s)
Atrial Fibrillation/surgery , Cardiac Catheters , Catheter Ablation/instrumentation , Cryosurgery/instrumentation , Pulmonary Veins/surgery , Action Potentials , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Cryosurgery/adverse effects , Equipment Design , Female , Heart Rate , Humans , Italy , Male , Middle Aged , Operative Time , Pulmonary Veins/physiopathology , Recurrence , Registries , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
18.
J Interv Card Electrophysiol ; 56(1): 9-18, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31452001

ABSTRACT

PURPOSE: Pulmonary vein isolation (PVI) using cryoablation (PVI-C) is a widespread therapy for treating symptomatic, recurrent atrial fibrillation (AF). The impacts of sex on efficacy and safety of PVI-C in a real-world clinical practice is lacking. In a multicenter prospective project, we evaluated whether clinical characteristics, procedure parameters, procedural complications, long-term AF recurrence rates, and/or AF-related symptoms differed according to sex in patients treated with PVI-C. METHODS: Data from the study population were collected in the framework of the 1STOP ClinicalService® project, involving 47 Italian cardiology centers. Multivariable statistical analyses were conducted to determine if any baseline clinical characteristics impacted the efficacy of PVI-C. RESULTS: From April 2012, 2125 patients (27% female, 59 ± 11 years, 73% paroxysmal AF, and mean left atrial diameter = 42 ± 8 mm) underwent PVI-C. According to baseline characteristics, women were more likely to be older, with higher clinical risk scores (e.g., CHA2DS2-VASc), and a higher number of tested antiarrhythmic drugs before the index PVI-C procedure. Male and female cohorts showed comparable procedure time (mean = 107.7 ± 46.8 min) and a similar incidence of periprocedural complications (4.5% overall), even after adjustment for baseline characteristics (P = 0.880). The multivariable analyses demonstrated that the strongest predictor of AF recurrences was sex (0.74; 95% CI 0.58-0.93; P = 0.011). After propensity score adjustment, the hazard ratio from a multivariable model, which included age and AF type (persistent) as covariates, was 0.76 (0.60-0.97) (P = 0.025). CONCLUSIONS: According to the 1STOP project, in a real-world setting, PVI-C was relatively safe regardless of the patient's sex; however, when considering efficacy of the procedure, female patients had a lower long-term efficacy in comparison to males. CLINICAL TRIAL REGISTRATION: NCT01007474.


Subject(s)
Atrial Fibrillation/surgery , Cryosurgery/methods , Pulmonary Veins/surgery , Female , Humans , Male , Middle Aged , Prospective Studies , Recurrence , Sex Factors
19.
Indian Pacing Electrophysiol J ; 19(6): 211-215, 2019.
Article in English | MEDLINE | ID: mdl-31238123

ABSTRACT

BACKGROUND: The new version of inner lumen mapping catheter (Achieve Advance™; Medtronic, Minnesota, USA) includes a new solid core which provides improved rotational response, as compared to the current Achieve Mapping Catheter. In the present study, we sought to analyze the rate of visualisation of real-time recordings using this new device comparing it with a large cohort of patients having undergone second generation cryoballoon (CB) ablation using the previous Achieve mapping catheter. METHODS: All patients having undergone CB ablation using the Achieve Advance and the last 150 consecutive patients having undergone CB ablation using the previous Achieve were analysed. Exclusion criteria were presence of an intracavitary thrombus, uncontrolled heart failure, moderate or severe valvular disease and contraindications to general anesthesia. RESULTS: A total of 200 consecutive patients (60.1 ±â€¯9.5 years, 75% males) were evaluated (50 Achieve Advance and 150 old Achieve). Real-time recordings were significantly more prevalent in the "new Achieve Advance" population compared with the "old Achieve" group (73.5% vs 56.8%; p = 0.0001). Real-time recordings could be more frequently visualized in the "Achieve Advance" group in all veins except RIPV (LSPV: 86% vs 71.3%, p = 0.04; LIPV: 84% vs 62.7%, p = 0.005; RSPV: 78% vs 52%, p < 0.0001; RIPV: 46% vs 41.3%, p = 0.3). CONCLUSIONS: The rate of visualisation of real-time recordings is significantly higher using the new Achieve Advance if compared to the previous Achieve mapping catheter in the setting of CB ablation. Real-time recordings can be visualized in approximately 73.5% of veins with this new device.

20.
J Arrhythm ; 34(4): 402-409, 2018 Aug.
Article in English | MEDLINE | ID: mdl-30167011

ABSTRACT

BACKGROUND: Cavotricuspid isthmus (CTI) radiofrequency (RF) catheter ablation is the standard treatment for patients suffering from CTI-dependent atrial flutter (AFL). The aim of this study was to compare the use in clinical practice of 8-mm gold-tip catheter (8mmRFC) and open-irrigated gold-tip catheter (irrRFC) for RF typical AFL ablation. METHODS: Patients with typical AFL were treated with 8mmRFC or irrRFC catheters according to investigator preferences. The primary endpoint was the cumulative radiofrequency time (CRFT). Fluoroscopy time, acute and 6-month success rates were secondary endpoints. RESULTS: After excluding 3 patients with left AFL, 157 of the enrolled patients (median age 71.8 [interquartile range, 64.1-76.2], 76% men, 91% in NYHA class ≤II, 65% with no structural heart disease) were analyzed: 74 (47%) subjects were treated with the 8mmRFC and 83 (53%) with the irrRFC. The median CRFT was 3 [2-6] minutes in the 8mmRFC group and 5 [3-7] minutes in the irrRFC group (P = .183). There were no significant differences in ablation success rates, intraprocedural CTI reconnections, audible steam pops, and procedural times. In the 8mmRFC group, a significantly lower fluoroscopy time was observed as compared to the irrRFC group (8 [5-12] vs 15 [10-20] minutes, P < .001). During the follow-up period, AFL recurrences were documented in 3 patients in the 8mmRFC group and 2 in the irrRFC group (P = .655). CONCLUSIONS: The 8mmRFC and the irrRFC performed similarly in routine practice for CTI ablation in terms of cumulative RF time, acute and 6-month success rates. Fluoroscopy time was significantly lower in the 8mmRFC group.

SELECTION OF CITATIONS
SEARCH DETAIL
...