Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Sensors (Basel) ; 22(22)2022 Nov 10.
Article in English | MEDLINE | ID: mdl-36433286

ABSTRACT

The proper classification of the origins of food products is a crucial issue all over the world nowadays. In this paper, the authors present a device-a multispectral portable fibre-optic reflectometer and signal processing patch-together with a machine-learning algorithm for the classification of the origins of chicken eggshells in the case of Mycoplasma synoviae infection. The sensor device was developed based on previous studies with a continuous spectrum in transmittance and selected spectral lines in reflectance. In the described case, the sensor is based on the integration of reflected spectral data from short spectral bands from the VIS and NIR region, which are produced by single-colour LEDs and introduced to the sample via a fibre bundle. The measurement is carried out in a sequence, and the reflected signal is pre-processed to be put in the machine learning algorithm. The support vector machine algorithm is used together with three different types of data normalization. The obtained results of the F-score factor for classification of the origins of samples show that the percentages of eggs coming from Mycoplasma synoviae infected hens are up to 87% for white and 96% for brown eggshells.


Subject(s)
Mycoplasma Infections , Mycoplasma synoviae , Animals , Female , Egg Shell , Chickens , Mycoplasma Infections/diagnosis , Mycoplasma Infections/veterinary , Eggs
2.
Sensors (Basel) ; 22(20)2022 Oct 14.
Article in English | MEDLINE | ID: mdl-36298151

ABSTRACT

The presented research shows the possibilities of creating in-line magnetic sensors based on the detection of changes of light propagation parameters, especially polarization, obtained by mixing Fe3O4 nanoparticles with hexadecane (higher alkane) surrounding a biconical optical fiber taper. The fiber optic taper allows to directly influence light parameters inside the taper without the necessity to lead the beam out of the structure. The mixture of hexadecane and Fe3O4 nanoparticles forms a special cladding surrounding a fiber taper which can be controlled by external factors such as the magnetic field. Described studies show changes of transmission (power, loss) and polarization properties like azimuth, and ellipticity, depending on the location of the mixture on sections of tapered optical fiber. The taper was made of a standard single-mode telecommunication fiber, stretched out to a length of 20.0 ± 0.5 mm and the diameter of the tapers is around 15.0 ± 0.3 µm, with the loss lower than 0.5 dB @ 1550 nm. Such a taper causes the beam to leak out of the waist structure and allows the addition of the external beam-controlling cladding material. The presented research can be used to build polarization switches or optical sensor. The results show that it can be a new way to control the propagation parameters of a light beam using tapered optical fiber and magnetic mixture.

3.
Sensors (Basel) ; 22(3)2022 Feb 07.
Article in English | MEDLINE | ID: mdl-35161991

ABSTRACT

Polymer microtips are 3D microstructures manufactured on the end face of an optical fiber by using the photopolymerization process. Such micro-optic elements made on a multi-mode optical fiber were previously tested as a transducer of refractive index sensor. These studies were an inspiration to investigate the possibility of using this type of transducer to measure the presence of volatile organic compounds in the air. The experimental results of microtips polymerized with UV and VIS were reported. It was possible to detect the presence of five different volatile compounds in the air due to the sensitivity of the transducer to the refractive indices changes. These changes were induced by the vapors condensed on the microtip surface. The measured time responses have shown that the return loss decreases rapidly as the microtip is inserted inside a glass vial filled with the tested compound. Moreover, correlations between calculated dynamic ranges and refractive indices and volumes of the volatile compounds inside the vials were negligible. Therefore, this type of sensor can be categorized as a condensed material threshold sensor. This sensor can be used in warning systems for monitoring leakages of pipelines carrying volatile chemicals.

4.
Sensors (Basel) ; 20(23)2020 Dec 05.
Article in English | MEDLINE | ID: mdl-33291509

ABSTRACT

A polymer microtip manufactured at the end of a multi-mode optical fiber by using the photopolymerization process offers good reflective properties, therefore, it is applicable as an optical fiber sensor micro-transducer. The reflective properties of this microelement depend on the monomer mixture used, optical fiber type, and light source initiating polymerization. Experimental results have shown that a proper selection of these parameters has allowed the design of a new class of sensing structure which is sensitive to the refractive index (RI) changes of a liquid medium surrounding the microtip. An optical backscatter reflectometer was applied to test a group of micro-transducers. They were manufactured from two monomer mixtures on three different types of multi-mode optical fibers. They were polymerized by means of three optical light sources. Selected micro-transducers with optimal geometries were immersed in reference liquids with a known RI within the range of 1.3-1.7. For a few sensors, the linear dependences of return loss and RI have been found. The highest sensitivity was of around 208 dB/RIU with dynamic 32 dB within the range of 1.35-1.48. Sensing characteristics have minima close to RI of a polymer microelement, therefore, changing its RI can give the possibility to tune sensing properties of this type of sensor.

5.
Materials (Basel) ; 13(2)2020 Jan 16.
Article in English | MEDLINE | ID: mdl-31963159

ABSTRACT

The technology of polymer microtips' manufacturing on the ends of selected multi-mode fibers has been reported. The study's key element was an extended description of technology parameters' influence on the shape of these 3D microstructures. Basic technology parameters such as spectral characteristics of the light source, monomer mixture type, optical power, and exposure time were taken under consideration. Depending on those parameters, different shapes, sizes, and surface structures of microtips were obtained. The spectral characteristics of the light and optical power delivered to a monomer drop were identified as the most important parameters for the formation of the desired 3D shape of the microtip. Presented experimental results are the base for further studies directed to the application of these micro-elements in the fields of optical measurements and sensors' technology.

6.
Sensors (Basel) ; 19(14)2019 Jul 10.
Article in English | MEDLINE | ID: mdl-31295898

ABSTRACT

This article proposes an interferometric method for a variable depolarizer characterization with features that distinguish it from the polarimetric system. Information about the behavior of a vertically aligned nematic cell as a variable depolarizer can be extracted from Young interferometer measurements in real time. These results could be significant for understanding the polarization phenomena in depolarizing media such as biological tissue.

7.
Sensors (Basel) ; 16(12)2016 Dec 16.
Article in English | MEDLINE | ID: mdl-27999299

ABSTRACT

Starting with descriptions of rotational seismology, areas of interest and historical field measurements, the fundamental requirements for rotational seismometers for seismological and engineering application are formulated. On the above basis, a review of all existing rotational seismometers is presented with a description of the principles of their operation as well as possibilities to fulfill formulated requirements. This review includes mechanical, acoustical, electrochemical and optical devices and shows that the last of these types are the most promising. It is shown that optical rotational seismometer based on the ring-laser gyroscope concept is the best for seismological applications, whereas systems based on fiber-optic gyroscopes demonstrate parameters which are also required for engineering applications. Laboratory results of the Fibre-Optic System for Rotational Events & Phenomena Monitoring using a small 1-D shaking table modified to generate rotational excitations are presented. The harmonic and time-history tests demonstrate its usefulness for recording rotational motions with rates up to 0.25 rad/s.

8.
Opt Lett ; 38(13): 2224-6, 2013 Jul 01.
Article in English | MEDLINE | ID: mdl-23811884

ABSTRACT

In this Letter, we present the technology of fiber Bragg grating (FBG) inscription in highly birefringent (HB) few-mode microstructured fibers (MSFs) with two different (nanosecond and femtosecond) lasers in a Talbot interferometer setup. The spectral characteristics of FBGs written in the core region of the investigated fiber, with particular modes represented by dual peaks, are presented and discussed. Furthermore, we calculate the fundamental fiber parameters (mode effective refractive index and phase modal birefringence) from the spectral characteristics and show very good agreement with the performed numerical fiber characterization. We expect the results of our experiments to be very useful in future development of FBG sensors based on novel HB MSFs, with enhanced strain sensitivity of higher-order modes.

9.
Opt Express ; 21(6): 7107-17, 2013 Mar 25.
Article in English | MEDLINE | ID: mdl-23546092

ABSTRACT

We demonstrate an experimental study of the chromatic dispersion properties for a series of microstructured fibers (MSFs) dedicated for a supercontinuum generation. With white-light interferometry application we analyze experimentally how the small variations of structural parameters, i.e. an air-hole diameter and a lattice constant, influence dispersion characteristics in different groups of MSFs. Our study provides useful information on how to design the fiber which is less sensitive to the fabrication imperfections. Moreover those investigations are the initial step to the development of the customized or tunable supercontinuum light sources based on MSFs with slightly changed structural parameters which can generate light with a different spectrum range, adapted to a proper application.


Subject(s)
Fiber Optic Technology/instrumentation , Interferometry/instrumentation , Refractometry/instrumentation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis
10.
Opt Express ; 20(24): 26996-7002, 2012 Nov 19.
Article in English | MEDLINE | ID: mdl-23187555

ABSTRACT

We present the results of theoretical and experimental characterization of a designed and manufactured dual-mode highly birefringent microstructured fiber. We also demonstrate the measured values of polarimetric temperature and strain sensitivity of both the fundamental and second order modes. As the mode field of the second order mode has a strong interaction with the fiber air holes, we observed a significant (over two orders of magnitude) increase in the polarimetric strain sensitivity of this mode in comparison to the fundamental mode. The enhanced strain sensitivity together with the low temperature sensitivity makes our fiber very attractive for application as extremely sensitive temperature independent strain transducers.


Subject(s)
Light , Optical Fibers , Refractometry/instrumentation , Scattering, Radiation , Transducers , Birefringence , Computer-Aided Design , Equipment Design
SELECTION OF CITATIONS
SEARCH DETAIL
...