Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Analyst ; 148(20): 5221-5232, 2023 Oct 05.
Article in English | MEDLINE | ID: mdl-37724415

ABSTRACT

Pyrolysis is a promising way to convert plastic waste into valuable resources. However, for downstream upgrading processes, many undesirable species, such as conjugated diolefins or heteroatom-containing compounds, can be generated during this pyrolysis. In-depth chemical characterization is therefore required to improve conversion and valorization. Because of the high molecular diversity found in these samples, advanced analytical instrumentation is needed to provide accurate and complete characterization. Generally, direct infusion Fourier transform mass spectrometry is used to gather information at the molecular level, but it has the disadvantage of limited structural insights. To overcome this drawback, gas chromatography has been coupled to Fourier transform ion cyclotron resonance mass spectrometry. By taking advantage of soft atmospheric pressure photoionization, which preserves molecular information, and the use of different dopants (pyrrole, toluene, and benzene), selective ionization of different chemical families was achieved. Differences in the ionization energy of the dopants will only allow the ionization of the molecules of the pyrolysis oil which have lower ionization energy, or which are accessible via specific chemical ionization pathways. With a selective focus on hydrocarbon species and especially hydrocarbon species having a double bond equivalent (DBE) value of 2, pyrrole is prone to better ionize low-mass molecules with lower retention times compared to the dopant benzene, which allowed better ionization of high-mass molecules with higher retention times. The toluene dopant presented the advantage of ionizing both low and high mass molecules.

2.
Faraday Discuss ; 218(0): 417-430, 2019 08 15.
Article in English | MEDLINE | ID: mdl-31120046

ABSTRACT

Heavy petroleum fractions such as vacuum gas oils (VGOs) are structurally and compositionally highly complex mixtures. Nitrogen species, which have a significant impact on the subsequent refining processes, are generally removed by the hydrodenitrogenation (HDN) catalytic process. The purpose of this study was to identify and characterize compounds that are refractory to the HDN process. This may allow for the examination of the effectiveness of a vacuum distillate hydrotreatment catalytic bed in removing nitrogen-containing compounds before the cracking step. Three different VGO fractions of the same oil before and after HDN processes were analysed in ESI(+) mode by FTICR mass spectrometry and ion mobility spectrometry-mass spectrometry (IMS-MS), in particular compounds containing basic nitrogen, such as quinoline and isoquinoline. Ultra-high-resolution FTICR mass spectrometry provides a sufficiently high mass resolution power to resolve different compounds and attribute a unique molecular formula to each ion. Information on the isomeric content was obtained by use of tandem mass spectrometry (MS/MS) and IMS-MS. The evolution of the fragmentation of the N1 class of compounds as a function of collision energy allowed for the identification of the molecular nucleus raw formula. From the IMS-MS experiments, it clearly appeared that, based on the IMS peak width, a lower isomeric dispersity was obtained after the HDN process and, based on the drift time and collision cross section determination, species presenting longer alkyl branches are the molecules most refractory to the HDN process.

3.
J Am Soc Mass Spectrom ; 28(11): 2476-2482, 2017 11.
Article in English | MEDLINE | ID: mdl-28721674

ABSTRACT

Ion mobility coupled with mass spectrometry was proven to be an efficient way to characterize complex mixtures such as petroleum samples. However, the identification of isomeric species is difficult owing to the molecular complexity of petroleum and no availability of standard molecules. This paper proposes a new simple indicator to estimate the isomeric content of highly complex mixtures. This indicator is based on the full width at half maximum (FWHM) of the extracted ion mobility peak measured in millisecond or square angstrom that is corrected for instrumental factors such as ion diffusion. This value can be easily obtained without precisely identifying the number of isomeric species under the ion mobility peaks. Considering the Boduszynski model, the ion mobility profile for a particular elemental composition is expected to be a continuum of various isomeric species. The drift time-dependent fragmentation profile was studied and confirmed this hypothesis, a continuous evolution of the fragmentation profile showing that the larger alkyl chain species were detected at higher drift time values. This new indicator was proven to be a fast and efficient method to compare vacuum gas oils for which no difference was found using other analytical techniques. Graphical Abstract ᅟ.

SELECTION OF CITATIONS
SEARCH DETAIL
...