Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-39023499

ABSTRACT

BACKGROUND: Sodium-glucose cotransporter 2 inhibitors were shown to reduce morbidity and mortality in patients with heart failure. OBJECTIVES: This study aims to assess potential effects of dapagliflozin in nondiabetic patients with heart failure with reduced ejection fraction (HFrEF) and heart failure with mildly reduced ejection fraction (HFmrEF) on cardiac function assessed by speckle tracking echocardiography (STE). METHODS: This randomized, prospective, single-center, open-label trial compared consecutive nondiabetic outpatients with HFrEF or HFmrEF receiving dapagliflozin with patients treated with optimal medical therapy (OMT) except sodium-glucose cotransporter type 2 inhibitors. Primary endpoint was the presence of a significant modification of left ventricular global longitudinal strain, diastolic function (as peak atrial longitudinal strain) and right ventricular function by STE from baseline to 6 months. Cardiovascular events and parameters of congestion were assessed as safety-exploratory endpoints. RESULTS: Overall, 88 patients (38% HFmrEF) were enrolled and randomized to start dapagliflozin on top of OMT (n = 44) or to continue with OMT (n = 44). All STE values improved in the dapagliflozin group after 6 months, whereas there was a nonsignificant improvement in OMT group. Moreover, when comparing the modification of STE parameters at follow-up in patients with HFrEF and HFmrEF, only the main treatment effect resulted statistically significant in both groups (P < 0.0001), indicating a significant difference between dapagliflozin and OMT. CONCLUSIONS: This study provided randomized data on the beneficial effect of dapagliflozin in nondiabetic patients with HFrEF and HFmrEF in terms of myocardial performance measured by the most sensitive echocardiographic technique, ie, STE. This suggests its usefulness for left ventricular reverse remodeling and better quality of life in patients with HFrEF and HFmrEF. (Effects of Dapagliflozin on cardiac deformation and clinical outcomes in heart failure with reduced and mildly reduced ejection fraction [DAPA ECHO trial]; EudraCT number: 2021-005394-66).

2.
J Surg Educ ; 81(4): 597-606, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38388310

ABSTRACT

OBJECTIVE: Studying liver anatomy can be challenging for medical students and surgical residents due to its complexity. Three-dimensional visualization technology (3DVT) allows for a clearer and more precise view of liver anatomy. We sought to assess how 3DVT can assist students and surgical residents comprehend liver anatomy. DESIGN: Data from 5 patients who underwent liver resection for malignancy at our institution between September 2020 and April 2022 were retrospectively reviewed and selected following consensus among the investigators. Participants were required to complete an online survey to investigate their understanding of tumor characteristics and vascular variations based on patients' computed tomography (CT) and 3DVT. SETTING: The study was carried out at the General and Hepato-Biliary Surgery Department of the University of Verona. PARTICIPANTS: Among 32 participants, 13 (40.6%) were medical students, and 19 (59.4%) were surgical residents. RESULTS: Among 5 patients with intrahepatic lesions, 4 patients (80.0%) had at least 1 vascular variation. Participants identified number and location of lesions more correctly when evaluating the 3DVT (84.6% and 80.9%, respectively) compared with CT scans (61.1% and 64.8%, respectively) (both p ≤ 0.001). The identification of any vascular variations was more challenging using the CT scans, with only 50.6% of correct answers compared with 3DVT (72.2%) (p < 0.001). Compared with CT scans, 3DVT led to a 23.5%, 16.1%, and 21.6% increase in the correct definition of number and location of lesions, and vascular variations, respectively. 3DVT allowed for a decrease of 50.8 seconds (95% CI 23.6-78.0) in the time needed to answer the questions. All participants agreed on the usefulness of 3DVT in hepatobiliary surgery. CONCLUSIONS: The 3DVT facilitated a more precise preoperative understanding of liver anatomy, tumor location and characteristics.


Subject(s)
Internship and Residency , Liver Neoplasms , Students, Medical , Humans , Retrospective Studies , Comprehension , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Imaging, Three-Dimensional/methods
3.
Int J Cardiol ; 400: 131808, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38262482

ABSTRACT

BACKGROUND: Athlete's heart is associated with physiological electrical and structural remodelling. Despite the plethora of data published on male athletes, solid data derived from female athletes, compared to male counterparts or sedentary women, are still scarce. OBJECTIVES: We aimed to analyze the electrical, structural, and functional characteristics of athlete's heart in female and male athletes vs sedentary controls. METHODS: Olympic athletes and sedentary controls were evaluated by resting ECG and echocardiography. Athletes were divided into 4 different sports groups. RESULTS: The study population included 1096 individuals (360 female athletes, 410 male athletes, 130 sedentary women and 196 sedentary men). Female athletes had lower resting heart rate, longer PR interval, higher voltage of R, and T waves and more frequently incomplete RBBB, left ventricular (LV) hypertrophy, early repolarization, and anterior T-wave inversion as compared to controls. Biventricular cavity dimensions and LV wall thickness were greater in female athletes than in female controls. However, women showed a lower degree of training-induced structural remodelling than men. In female athletes, both cavity dimensions and LV wall thickness increased from those engaged in skill and power to mixed and endurance disciplines. However, in female athletes, contrary to males, the ECG changes were not significantly different according to the different types of sport discipline. CONCLUSIONS: Highly-trained women demonstrate relevant training-induced electrical and structural remodelling. However, the type of sport did not influence ECG parameters in women, contrary to men, while it impacted biventricular morphologic remodelling, with endurance athletes showing the greatest degree of adaptation.


Subject(s)
Cardiomegaly, Exercise-Induced , Sports , Humans , Male , Female , Ventricular Function, Left/physiology , Athletes , Sports/physiology , Echocardiography , Hypertrophy, Left Ventricular
4.
Nanophotonics ; 13(1): 63-73, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38235070

ABSTRACT

Several optical microscopy methods are now available for characterizing scientific and industrial processes at sub-micron resolution. However, they are often ill-suited for imaging rapid events. Limited by the trade-off between camera frame-rate and sensitivity, or the need for mechanical scanning, current microscopes are optimized for imaging at hundreds of frames-per-second (fps), well-below what is needed in processes such as neuronal signaling or moving parts in manufacturing lines. Here, we present a scan-less technology that allows sub-micrometric imaging at thousands of fps. It is based on combining a single-pixel camera with parallelized encoded illumination. We use two acousto-optic deflectors (AODs) placed in a Mach-Zehnder interferometer and drive them simultaneously with multiple and unique acoustic frequencies. As a result, orthogonal light stripes are obtained that interfere with the sample plane, forming a two-dimensional array of flickering spots - each with its modulation frequency. The light from the sample is collected with a single photodiode that, after spectrum analysis, allows for image reconstruction at speeds only limited by the AOD's bandwidth and laser power. We describe the working principle of our approach, characterize its imaging performance as a function of the number of pixels - up to 400 × 400 - and characterize dynamic events at 5000 fps.

6.
Updates Surg ; 75(1): 105-114, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36006558

ABSTRACT

Three-dimensional visualization technology (3DVT) has been recently introduced to achieve a precise preoperative planning of liver surgery. The aim of this observational study was to assess the accuracy of 3DVT for complex liver resections. 3DVT with hyper accuracy three-dimensional (HA3D™) technology was introduced at our institution on February 2020. Anatomical characteristics were collected from two-dimensional imaging (2DI) and 3DVT, while intraoperative and postoperative outcomes were recorded prospectively. A total of 62 patients were enrolled into the study. 3DVT was able to study tumor extension and liver anatomy, identifying at least one vascular variation in 37 patients (59.7%). Future remnant liver volume (FRLV) was measured using 2DI and 3DVT. The paired samples t test assessed positive correlation between the two methods (p < 0.001). At least one vessel was suspected to be invaded by the tumor in 8 (15.7%) 2DI cases vs 16 (31.4%) 3DVT cases, respectively. During surgery, vascular invasion was detected in 17 patients (33.3%). A total of 73 surgical procedures were proposed basing on 2DI, including 2 alternatives for 16 patients. After 3DVT, the previously planned procedure was changed in 15 cases (29.4%), due to the clearer information provided. A total of 51 patients (82%) underwent surgery. The most frequent procedure was right hepatectomy (33.3%), followed by left hepatectomy (23.5%) and left trisectionectomy (13.7%). Vascular resection and reconstruction were performed in 10 patients (19.6%) and portal vein was resected in more than half of these cases (66.7%). 3DVT leads to a more detailed and tailored approach to complex liver surgery, improving surgeons' knowledge of liver anatomy and accuracy of liver resection.


Subject(s)
Hepatectomy , Liver Neoplasms , Humans , Hepatectomy/methods , Liver Neoplasms/surgery , Imaging, Three-Dimensional , Portal Vein , Technology
SELECTION OF CITATIONS
SEARCH DETAIL