1.
World J Nucl Med ; 18(4): 373-377, 2019.
Article in English | MEDLINE | ID: mdl-31933553

ABSTRACT

End-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) are cardiac volumes that have crucial roles in diagnosis of cardiovascular diseases (CVD) in patients. There are differences between these mentioned parameters in echocardiography (Echo) and myocardial perfusion scintigraphy (MPS) in clinical practice. In this study, we determined the nearest filtering parameters in the analysis of MPS data in comparison with three-dimensional echocardiography (3DE). All of patients were in this study, and 3DE and MPS were performed for all patients at rest phase in the same day. MPS images were analyzed through quantitative gated single photon emission computer tomography (SPECT) software with Butterworth filter which was a fixed order (order = 5) and variable cutoffs (COs) of 0.3, 0.35, 0.4, 0.45, and 0.5. The EDV, ESV, and EF values were measured by 3DE and MPS and compared. Based on the above different COs, the ESVs of MPS were 15.5 ± 18 mL, 18 ± 20 mL, 21 ± 22.5 mL, 22 ± 23 mL, and 22.5 ± 23.5 mL, respectively, while ESV of 3DE was 44.4 ± 23.5 mL. It was observed as a significant difference between MPS and 3DE for ESV. The EDVs of MPS were 61.3 ± 24.5 ml, 64 ± 26.5 ml, 68 ± 29.5 ml, 72 ± 31 ml, and 76 ± 32.2 ml, respectively, while EDV of 3DE was 105 ± 30 ml, which was significantly different between two methods. The EFs of MPS were 79% ± 14%, 76% ± 13%, 73.5% ± 12%, 73.5% ± 11%, and 74% ± 11%, respectively. The EF of 3DE was 58.4% ± 10% ml. It was statistically significant difference in values of EF between SPECT analysis parameters and 3DE. It was interesting when the COs increased from 0.3 to 0.5; the cardiac volumes increased while the EF decreased. The measured ESV and EDV values were lower in females than males while the EFs of females were higher than males. Finally, we demonstrate that the nearest Cos for measuring of EF and cardiac volumes for analysis of MPS data in comparison with 3DE are 0.45 and 0.5, respectively.

2.
World J Nucl Med ; 15(1): 12-7, 2016.
Article in English | MEDLINE | ID: mdl-26912973

ABSTRACT

The detector is a critical component of the single photon emission computed tomography (SPECT) imaging system for giving accurate information from the exact pattern of radionuclide distribution in the target organ. The SIMIND Monte Carlo program was utilized for the simulation of a Siemen's dual head variable angle SPECT imaging system with a low energy high resolution (LEHR) collimator. The Planar and SPECT scans for a (99m)Tc point source and a Jaszczak Phantom with the both experiment and simulated systems were prepared and after verification and validation of the simulated system, the similar scans of the phantoms were compared (from the point of view of the images' quality), namely, the simulated system with the detectors including bismuth germanate (BGO), yttrium aluminum garnet (YAG:Ce), Cerium-doped yttrium aluminum garnet (YAG:Ce), yttrium aluminum perovslite (YAP:Ce), lutetium aluminum garnet (LuAG:Ce), cerium activated lanthanum bromide (LaBr3), cadmium zinc telluride (CZT), and sodium iodide activated with thallium [NaI(Tl)]. The parameters of full width at half maximum (FWHM), energy and special resolution, sensitivity, and also the comparison of images' quality by the structural similarity (SSIM) algorithm with the Zhou Wang and Rouse/Hemami methods were analyzed. FWHMs for the crystals were calculated at 13.895, 14.321, 14.310, 14.322, 14.184, and 14.312 keV and the related energy resolutions obtained 9.854, 10.229, 10.221, 10.230, 10.131, and 10.223 %, respectively. Finally, SSIM indexes for comparison of the phantom images were calculated at 0.22172, 0.16326, 0.18135, 0.17301, 0.18412, and 0.20433 as compared to NaI(Tl). The results showed that BGO and LuAG: Ce crystals have high sensitivity and resolution, and better image quality as compared to other scintillation crystals.

SELECTION OF CITATIONS
SEARCH DETAIL