Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
J Am Vet Med Assoc ; 252(9): 1090-1096, 2018 May 01.
Article in English | MEDLINE | ID: mdl-29641336

ABSTRACT

OBJECTIVE To describe the ultrasonographic appearance of the urinary bladder incision site in dogs that underwent cystotomy for treatment of urolithiasis. DESIGN Prospective, longitudinal study. ANIMALS 18 client-owned dogs. PROCEDURES Dogs underwent urinary bladder ultrasonography at baseline (≤ 1 day before surgery) and at 1 day and approximately 2, 6, and 12 weeks after cystotomy for urocystolith removal. A baseline ratio between ventral (cystotomy site) and corresponding dorsal midline wall thickness was calculated and used to account for measurement variations attributable to bladder distension at subsequent visits. Patient signalment, weight, medications administered, urocystolith composition, and culture results were recorded. Clinical signs, reoccurrence of hyperechoic foci, and suture visualization were recorded at follow-up examinations. Variables were evaluated for association with cystotomy site thickening and resolution of thickening. RESULTS Median wall thickness at the ventral aspect of the bladder was significantly greater than that of the corresponding dorsal aspect at baseline. Cystotomy site thickening peaked 1 day after surgery and decreased at subsequent visits in a linear manner. Twelve weeks after surgery, 5 of 10 clinically normal dogs evaluated had persistent cystotomy site thickening. Eleven of 18 dogs had reoccurrence of hyperechoic foci within the bladder at some time during the study (median time to first detection, 17 days after surgery). CONCLUSIONS AND CLINICAL RELEVANCE Persistent cystotomy site thickening can be present up to 3 months after cystotomy for urolithiasis in dogs without lower urinary tract signs. Reoccurrence of hyperechoic foci in the bladder, although subclinical, was detected earlier and at a higher rate than anticipated.


Subject(s)
Dog Diseases/surgery , Urolithiasis/veterinary , Animals , Cystotomy/veterinary , Dog Diseases/diagnostic imaging , Dogs , Female , Longitudinal Studies , Male , Postoperative Complications/diagnostic imaging , Postoperative Complications/veterinary , Prospective Studies , Treatment Outcome , Ultrasonography/veterinary , Urinary Retention/diagnostic imaging , Urinary Retention/veterinary , Urinary Tract Infections/diagnostic imaging , Urinary Tract Infections/microbiology , Urinary Tract Infections/veterinary , Urolithiasis/surgery
2.
PLoS One ; 11(8): e0161110, 2016.
Article in English | MEDLINE | ID: mdl-27556230

ABSTRACT

OBJECTIVES: To evaluate the ability of an alignment jig/saw guide to reproduce appropriate osteotomy positions in the tibial plateau leveling osteotomy (TPLO) in the dog. METHODS: Lateral radiographs of 65 clinical TPLO procedures using an alignment jig and freehand osteotomy performed by experienced TPLO surgeons using a 24 mm radial saw blade between Dec 2005-Dec 2007 and Nov 2013-Nov 2015 were reviewed. The freehand osteotomy position was compared to potential osteotomy positions using the alignment jig/saw guide. The proximal and distal jig pin holes on postoperative radiographs were used to align the jig to the bone; saw guide position was selected to most closely match the osteotomy performed. The guide-to-osteotomy fit was categorized by the distance between the actual osteotomy and proposed saw guide osteotomy at its greatest offset (≤1 mm = excellent; ≤2 mm = good; ≤3 mm = satisfactory; >3 mm = poor). RESULTS: Sixty-four of 65 TPLO osteotomies could be matched satisfactorily by the saw guide. Proximal jig pin placement 3-4 mm from the joint surface and pin location in a craniocaudal plane on the proximal tibia were significantly associated with the guide-to-osteotomy fit (P = 0.021 and P = 0.047, respectively). CLINICAL SIGNIFICANCE: The alignment jig/saw guide can be used to reproduce appropriate freehand osteotomy position for TPLO. Furthermore, an ideal osteotomy position centered on the tibial intercondylar tubercles also is possible. Accurate placement of the proximal jig pin is a crucial step for correct positioning of the saw guide in either instance.


Subject(s)
Osteotomy/methods , Tibia/surgery , Animals , Bone Nails , Dogs , Knee Joint , Radiography , Tibia/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL