1.
Int J Mol Sci ; 24(18)2023 Sep 07.
Article in English | MEDLINE | ID: mdl-37762097

ABSTRACT

The determination of RNA integrity is a critical quality assessment tool for gene expression studies where the experiment's success is highly dependent on the sample quality. Since its introduction in 1999, the gold standard in the scientific community has been the Agilent 2100 Bioanalyzer's RNA integrity number (RIN), which uses a 1-10 value system, from 1 being the most degraded, to 10 being the most intact. In 2015, Agilent launched 4200 TapeStation's RIN equivalent, and reported a strong correlation of r2 of 0.936 and a median error < ±0.4 RIN units. To evaluate this claim, we compared the Agilent 4200 TapeStation's RIN equivalent (RINe) and DV200 to the Agilent 2100 Bioanalyzer's RIN for 183 parallel RNA samples. In our study, using RNA from a total of 183 human postmortem brain samples, we found that the RIN and RINe values only weakly correlate, with an r2 of 0.393 and an average difference of 3.2 RIN units. DV200 also only weakly correlated with RIN (r2 of 0.182) and RINe (r2 of 0.347). Finally, when applying a cut-off value of 6.5 for both metrics, we found that 95.6% of samples passed with RIN, while only 23.5% passed with RINe. Our results suggest that even though RIN (Bioanalyzer) and RINe (TapeStation) use the same 1-10 value system, they should not be used interchangeably, and cut-off values should be calculated independently.


Subject(s)
Benchmarking , Brain , Humans , RNA
2.
medRxiv ; 2023 Jul 06.
Article in English | MEDLINE | ID: mdl-37461632

ABSTRACT

Determining RNA integrity is a critical quality assessment tool for gene expression studies where the experiment's success is highly dependent on sample quality. Since its introduction in 1999, the gold standard in the scientific community has been the Agilent 2100 Bioanalyzer's RNA Integrity Number (RIN) which uses a 1-10 value system with 1 being the most degraded to 10 being the most intact. In 2015, Agilent launched the 4200 Tapestation's RIN equivalent and reported a strong correlation of r 2 of 0.936 and median error < ± 0.4 RIN units. To evaluate this claim, we compared the Agilent 4200 Tapestation's RIN equivalent (RINe) and DV200 to the Agilent 2100 Bioanalyzer's RIN for 183 parallel RNA samples. In our study, using RNA from a total of 183 human postmortem brain samples, we found that the RIN and RINe values only weakly correlate with an r 2 of 0.393 and an average difference of 3.2 RIN units. DV200 also only weakly correlated with RIN (r 2 of 0.182) and RINe (r 2 of 0.347). Finally, when applying a cut-off value of 6.5 for both metrics, we found that 95.6% of samples passed with RIN, while only 23.5% passed with RINe. Our results suggest that even though RIN (Bioanalyzer) and RINe (Tapestation) use the same 1-10 value system, they should not be used interchangeably, and cut-off values should be calculated independently.

3.
J Neuropathol Exp Neurol ; 81(8): 643-649, 2022 07 19.
Article in English | MEDLINE | ID: mdl-35751438

ABSTRACT

The Alzheimer disease (AD) neuropathological hallmarks amyloid ß (Aß) and tau neurofibrillary (NF) pathology have been reported in the olfactory bulb (OB) in aging and in different neurodegenerative diseases, which coincides with frequently reported olfactory dysfunction in these conditions. To better understand when the OB is affected in relation to the hierarchical progression of Aß throughout the brain and whether OB pathology might be an indicator of AD severity, we assessed the presence of OB Aß and tau NF pathology in an autopsy cohort of 158 non demented control and 173 AD dementia cases. OB Aß was found in less than 5% of cases in lower Thal phases 0 and 1, in 20% of cases in phase 2, in 60% of cases in phase 3 and in more than 80% of cases in higher Thal phases 4 and 5. OB Aß and tau pathology significantly predicted a Thal phase greater than 3, a Braak NF stage greater than 4, and an MMSE score lower than 24. While OB tau pathology is almost universal in the elderly and therefore is not a good predictor of AD severity, OB Aß pathology coincides with clinically-manifest AD and might prove to be a useful biomarker of the extent of brain spread of both amyloid and tau pathology.


Subject(s)
Alzheimer Disease , Amyloidosis , Cognitive Dysfunction , Aged , Alzheimer Disease/pathology , Amyloid beta-Peptides/metabolism , Amyloidosis/pathology , Brain/pathology , Cognitive Dysfunction/pathology , Humans , Olfactory Bulb/metabolism , tau Proteins/metabolism