Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
Article in English | MEDLINE | ID: mdl-38584491

ABSTRACT

AIMS: To assess the impact of adenosine on quantitative myocardial blood flow (MBF) in a rapid stress-rest protocol compared to a rest-stress protocol using 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI) and to gain insights into the time dependency of such effects. METHODS AND RESULTS: Quantitative MBF at rest (rMBF), during adenosine-induced stress (sMBF) and myocardial flow reserve (MFR) were obtained from 331 retrospectively identified patients who underwent 13N-ammonia PET-MPI for suspected chronic coronary syndrome and who all exhibited no perfusion defects. Of these, 146 (44.1%) underwent a rapid stress-rest protocol with a time interval (Δtstress-rest) of 20 ± 4 minutes between adenosine infusion offset and rest-imaging, as per clinical routine. The remaining 185 (55.9%) patients underwent a rest-stress protocol and served as the reference. Groups did not differ regarding demographics, risk factors, medication, left ventricular function, and calcium scores. rMBF was significantly higher in the stress-rest vs. the rest-stress group (0.80 [IQR 0.66-1.00] vs. 0.70 [0.58-0.83] ml·min-1·g-1, p < 0.001) and, as sMBF was identical between groups (2.52 [2.20-2.96] vs. 2.50 [1.96-3.11], p = 0.347), MFR was significantly lower in the stress-rest group (3.07 [2.43-3.88] vs. 3.50 [2.63-4.10], p < 0.001). There was a weak correlation between Δtstress-rest and rMBF (r = -0.259, p = 0.002) and between Δtstress-rest and MFR (r = 0.163, p = 0.049), and the proportion of patients with abnormally high rMBF was significantly decreasing with increasing Δtstress-rest. CONCLUSIONS: Intravenously applied adenosine induces a long-lasting hyperemic effect on the myocardium. Consequently, rapid stress-rest protocols could lead to an overestimation of rMBF and an underestimation of MFR.

2.
Acad Radiol ; 31(4): 1248-1255, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37940426

ABSTRACT

RATIONALE AND OBJECTIVES: Cardiac magnetic resonance (CMR) and gated 13N-ammonia positron emission tomography myocardial perfusion imaging (PET-MPI) offer accurate and highly comparable global left ventricular ejection fraction (LVEF) measurements. In addition to accuracy, however, reproducibility is crucial to avoid variations in LVEF assessment potentially negatively impacting treatment decisions. We performed a head-to-head comparison of the reproducibility of LVEF measurements derived from simultaneously acquired CMR and PET-MPI using different state-of-the-art commercially available software. MATERIALS AND METHODS: 93 patients undergoing hybrid PET/MR were retrospectively included. LVEF was derived from CMR and PET-MPI at two separate core labs, using two state-of-the-art software packages for CMR (cvi42 and Medis Suite MR) and PET (QPET and CardIQ Physio). Intra- and inter-reader agreement was assessed using correlation and Bland-Altman (BA) analyses. RESULTS: While intra- and inter-reader reproducibility of LVEF was high among both modalities and all software packages (r ≥ 0.87 and ICC≥0.91, all significant at p < 0.0001), LVEF derived from PET-MPI and analyzed with QPET outperformed all other analyses (intra-reader reproducibility: r = 0.99, ICC=0.99; inter-reader reproducibility: r = 0.98, ICC=1.00; Pearson correlations significantly higher than all others at p ≤ 0.0001). BA analyses showed smaller biases for LVEF derived from PET-MPI (-0.1% and +0.9% for intra-reader, -0.4% and -0.8% for inter-reader agreement) than those derived from CMR (+0.7% and +2.8% for intra-reader, -0.9% and -2.2% for inter-reader agreement) with similar results for BA limits of agreement. CONCLUSION: Gated 13N-ammonia PET-MPI provides equivalent reproducibility of LVEF compared to CMR. It may offer a valid alternative to CMR for patients requiring LV functional assessment.


Subject(s)
Nitrogen Radioisotopes , Ventricular Function, Left , Humans , Stroke Volume , Ammonia , Reproducibility of Results , Retrospective Studies , Positron-Emission Tomography/methods , Magnetic Resonance Imaging/methods , Radiopharmaceuticals , Magnetic Resonance Spectroscopy , Perfusion
3.
Diagn Interv Imaging ; 105(4): 151-158, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38007373

ABSTRACT

PURPOSE: The invasive British Cardiovascular Intervention Society Jeopardy Score (iBCIS-JS) is a simple angiographic scoring system, enabling quantification of the extent of jeopardized myocardium related to clinically significant coronary artery disease (CAD). The purpose of this study was to develop and validate the coronary CT angiography-based BCIS-JS (CT-BCIS-JS) against the iBCIS-JS in patients with suspected or stable CAD. MATERIALS AND METHODS: Patients who underwent coronary CT angiography followed by invasive coronary angiography, within 90 days were retrospectively included. CT-BCIS-JS and iBCIS-JS were calculated, with a score ≥ 6 indicating extensive CAD. Correlation between the CT-BCIS-JS and iBCIS-JS was searched for using Spearman's coefficient, and agreement with weighted Kappa (κ) analyses. RESULTS: A total of 122 patients were included. There were 102 men and 20 women with a median age of 62 years (Q1, Q3: 54, 68; age range: 19-83 years). No differences in median CT-BCIS-JS (4; Q1, Q3: 0, 8) and median iBCIS-JS (4; Q1, Q3: 0, 8) were found (P = 0.18). Extensive CAD was identified in 53 (43.4%) and 52 (42.6%) patients using CT-BCIS-JS and iBCIS-JS, respectively (P = 0.88). CT-based and iBCIS-JS showed excellent correlation (r = 0.98; P < 0.001) and almost perfect agreement (κ = 0.93; 95% confidence interval: 0.90-0.97). Agreement for identification of an iBCIS-JS ≥ 6 was almost perfect (κ = 0.94; 95 % confidence interval: 0.87-0.99). CONCLUSION: The CT-BCIS-JS represents a feasible, and accurate method for quantification of CAD, with capabilities not different from those of iBCIS-JS. It enables simple, non-invasive identification of patients with anatomically extensive CAD.


Subject(s)
Coronary Artery Disease , Male , Humans , Female , Middle Aged , Young Adult , Adult , Aged , Aged, 80 and over , Coronary Artery Disease/diagnostic imaging , Coronary Angiography/methods , Computed Tomography Angiography , Retrospective Studies , Tomography, X-Ray Computed , Predictive Value of Tests
5.
J Arrhythm ; 38(5): 723-729, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36237857

ABSTRACT

Background: There is an ongoing debate on how cardiac resynchronization therapy (CRT) in the presence of total AV block affects atrial fibrillation (AF) episodes and symptoms in patients with AF. Methods: Seventy-five patients with symptomatic, drug and ablation refractory AF received, irrespective of their left ventricular ejection fraction (EF), either a CRT device and underwent subsequent atrioventricular node (AVN) ablation or already had a total AV block and underwent CRT upgrade. Long-lasting AF episodes (>48 h), left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter (LVEDD), left atrial diameter (LAD), NTproBNP levels, EHRA score, and NYHA class had been monitored on the follow-up. Results: The number of patients experiencing long-lasting AF episodes (>48 h) and symptoms decreased significantly within 24 months after CRT implantation in the presence of total AV block (p < .001) from 57 (76%) to 25 (33.3%). Mean LAD decreased from 52 mm (IQR 48.0-56.0) to 48 mm (IQR 42.0-52.0, p < .001) and LVEDD from 54 mm (IQR 49.0-58.0) to 51 mm (IQR 46.5-54.0, p < .001). Conclusion: A combination of total AVN block and biventricular pacing markedly reduces long-lasting AF episodes, symptoms, left atrial diameter, and left ventricular end-diastolic diameter.

6.
Praxis (Bern 1994) ; 110(4): 189-191, 2021.
Article in German | MEDLINE | ID: mdl-33726516

ABSTRACT

CME ECG 68/Answers: Gender Specificities in Heart Rhythm Disorders Abstract. Sex differences in heart rhythm disorders have been described, especially due to differences of hormone status in women and men. In general, women do have a higher baseline heart rate than men and shorter refractory periods of most structures in the conduction system, except the ventricles. This is particularly apparent in paroxysmal supraventricular tachycardias. The incidence of a dual AV nodal physiology is the same in both sexes. However, an AV-nodal reentry tachycardia is much more frequent in women than in men. The embryonal disposition for an accessory pathway, as well as the resultant AV reentry tachycardia is more common in men than in women. Focal atrial tachycardias do not reveal a clear dominance between the sexes. Knowledge about sex-related differences in heart rhythm disorders are relevant for its diagnostics. Therefore, important aspects will be discussed in this article.


Subject(s)
Tachycardia, Atrioventricular Nodal Reentry , Tachycardia, Supraventricular , Electrocardiography , Female , Heart Conduction System , Heart Ventricles , Humans , Male
7.
Praxis (Bern 1994) ; 110(3): 131-139, 2021.
Article in German | MEDLINE | ID: mdl-33653104

ABSTRACT

CME ECG 68: Gender Specificities in Heart Rhythm Disorders Abstract. Sex differences in heart rhythm disorders have been described, especially due to differences of hormone status in women and men. In general, women do have a higher baseline heart rate than men and shorter refractory periods of most structures in the conduction system, except the ventricles. This is particularly apparent in paroxysmal supraventricular tachycardias. The incidence of a dual AV nodal physiology is the same in both sexes. However, an AV-nodal reentry tachycardia is much more frequent in women than in men. The embryonal disposition for an accessory pathway, as well as the resultant AV reentry tachycardia is more common in men than in women. Focal atrial tachycardias do not reveal a clear dominance between the sexes. Knowledge about sex-related differences in heart rhythm disorders are relevant for its diagnostics. Therefore, important aspects will be discussed in this article.


Subject(s)
Tachycardia, Atrioventricular Nodal Reentry , Tachycardia, Supraventricular , Electrocardiography , Female , Heart Conduction System , Heart Ventricles , Humans , Male
8.
J Nucl Cardiol ; 28(4): 1364-1373, 2021 Aug.
Article in English | MEDLINE | ID: mdl-31399902

ABSTRACT

PURPOSE: A surface 12-lead electrocardiogram (ECG) is widely available, fast, inexpensive, and safe. However, its value to predict a true myocardial scar in patients with ischemic cardiomyopathy (ICM) has not been studied extensively yet. This study was conducted to assess whether Q waves on resting surface 12-lead ECG are predictive of non-viable myocardium in patients with ICM. METHODS: We analyzed resting ECGs of 149 patients with ICM undergoing cardiac positron emission tomography (PET) with 13N-ammonia (NH3) and 18F-fluorodeoxyglucose (FDG) at our institution. Pathological Q waves and QS complexes were assigned to one of three coronary artery territories and compared to the PET findings. Myocardial scar was defined as 2 or more contiguous myocardial segments with an average (matched) reduction of NH3 and FDG uptake <50% of the maximum value. RESULTS: Pathological Q waves had a sensitivity and specificity of 70% and 40%, respectively, and a PPV and NPV of 37% and 73%, respectively, to detect myocardial scar on FDG PET. For QS complexes, sensitivity and specificity were 46% and 59%, respectively, and PPV and NPV were 36% and 68%, respectively. Sensitivity was lower, but specificity was significantly higher in both the LCX and RCA compared to the LAD territory (p<0.001), particularly for QS complexes. CONCLUSION: Pathological Q waves on resting 12-lead ECG have poor or at best moderate sensitivity and specificity to detect myocardial scar on FDG PET. These findings support the use of more advanced imaging techniques to assess myocardial viability in ICM.


Subject(s)
Cicatrix/diagnostic imaging , Electrocardiography , Heart Failure/diagnostic imaging , Myocardial Ischemia/diagnostic imaging , Positron-Emission Tomography , Aged , Cicatrix/etiology , Female , Fluorodeoxyglucose F18 , Heart Failure/complications , Humans , Male , Middle Aged , Myocardial Ischemia/complications , Nitrogen Radioisotopes , Retrospective Studies , Sensitivity and Specificity
9.
Praxis (Bern 1994) ; 109(13): 1035-1038, 2020.
Article in German | MEDLINE | ID: mdl-33050812

ABSTRACT

CME ECG 66/Answers: Torsade de Pointes: The Danger of a Rotating Heart Axis Abstract. Torsade de pointes tachycardia is a potentially life-threatening heart rhythm disorder, caused by prolongation of the QT interval resulting in triggered activity. This QT prolongation can be congenital or acquired. If acquired, it is mainly caused by pharmacological therapy. The hallmark of torsade de pointes is an undulating QRS axis with a twist of the QRS complex around the ECG's baseline. Often, this polymorphic ventricular tachycardia is self-limiting, but degeneration into ventricular fibrillation is possible, which makes torsade de pointes tachycardia dangerous. This article aims to provide insights into etiology, diagnostics, prevention and management of this heart rhythm disorder.


Subject(s)
Long QT Syndrome , Tachycardia, Ventricular , Torsades de Pointes , Arrhythmias, Cardiac , Electrocardiography , Humans , Long QT Syndrome/diagnosis , Tachycardia, Ventricular/diagnosis , Torsades de Pointes/diagnosis
10.
Praxis (Bern 1994) ; 109(12): 944-951, 2020 Sep.
Article in German | MEDLINE | ID: mdl-32933390

ABSTRACT

CME ECC 66: Torsade de Pointes: The Danger of a Rotating Heart Axis Abstract. Torsade de pointes tachycardia is a potentially life-threatening heart rhythm disorder, caused by prolongation of the QT-interval resulting in triggered activity. This QT-prolongation can be congenital or acquired. If acquired, it is mainly caused by pharmacological therapy. The hallmark of torsade de pointes is an undulating QRS axis with a twist of the QRS complex around the ECG's baseline. Often, this polymorphic ventricular tachycardia is self-limiting, but degeneration into ventricular fibrillation is possible, which makes torsade de pointes tachycardia dangerous. This article aims to provide insights into etiology, diagnostics, prevention and management of this heart rhythm disorder.


Subject(s)
Long QT Syndrome , Tachycardia, Ventricular , Torsades de Pointes , Arrhythmias, Cardiac , Electrocardiography , Humans , Torsades de Pointes/complications
12.
Praxis (Bern 1994) ; 109(4): 253-258, 2020.
Article in German | MEDLINE | ID: mdl-32183650

ABSTRACT

CME ECC 65: The Athlete's ECG Abstract. Regular, intensive training in athletes causes a modulation of the heart due to higher vagal tone and emerging hypertrophy. To assess these changes, which can be seen in an athlete's ECG as well, an international group of experts constituted contemporary standards for ECG interpretation in athletes, the "Seattle Criteria" which are discussed in this article: Athletes often have a physiologic sinus bradycardia with a heart rate between 30 and 60 bpm and a pronounced respiratory arrhythmia. A junctional rhythm with retrograde depolarisation of the atria frequently occurs as well, especially at rest. Early repolarisation is also an occasional phenomenon in athletes. Depending on its morphology and the history of the athlete it may be regarded as physiologic. This article shall help to evaluate an athlete's ECG in a physician's routine.


Subject(s)
Athletes , Cardiomyopathies , Electrocardiography , Sports , Cardiomyopathies/diagnosis , Death, Sudden, Cardiac , Humans
13.
Cardiol J ; 25(5): 589-594, 2018.
Article in English | MEDLINE | ID: mdl-29240965

ABSTRACT

BACKGROUND: The impact of postural changes on various electrocardiography (ECG) characteristics has only been assessed in a few small studies. This large prospective trial was conducted to confirm or refute preliminary data and add important results with immediate impact on daily clinical practice. METHODS: ECGs in supine and upright position from 1028 patients were analyzed. Evaluation was made according to changes in T-wave vector and direction, ST-segment deviation, heart rate, QT interval and QTc interval was performed. Findings were correlated with the medical history of patients. RESULTS: Positional change from supine to upright resulted in a significantly increased heart rate (8.05 ± 7.71 bpm) and a significantly increased QTc interval after Bazetts (18 ± 23.45 ms) and Fridericas (8.84 ± 17.30) formula. In the upright position significantly more T-waves turned negative (14.7%) than positive (5.7%). ST elevation was recorded in only 0.4% and ST depression in not more than 0.2% of all patients. CONCLUSIONS: The majority of the patients do not show significant morphological changes in their ECG by changing the body position from supine to upright. Changes of QTc time instead, are significant and the interval might be overestimated in upright. Therefore assessment of the QTc interval should strictly be done in a supine position.


Subject(s)
Electrocardiography/methods , Heart Rate/physiology , Long QT Syndrome/diagnosis , Standing Position , Supine Position , Female , Follow-Up Studies , Humans , Long QT Syndrome/physiopathology , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Time Factors
14.
Acta Cardiol ; 70(6): 665-71, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26717214

ABSTRACT

OBJECTIVE: The objective of this study was assess robot-assisted gait therapy with the Lokomat® system in heart failure patients. METHODS: Patients (n = 5) with stable heart failure and a left ventricular ejection fraction of less than 45% completed a four-week aerobic training period with three trainings per week and an integrated dynamic resistance training of the lower limbs. Patients underwent testing of cardiac and inflammatory biomarkers. A cardiopulmonary exercise test, a quality of life score and an evaluation of the muscular strength by measuring the peak quadriceps force was performed. RESULTS: No adverse events occurred. The combined training resulted in an improvement in peak work rate (range: 6% to 36%) and peak quadriceps force (range: 3% to 80%) in all participants. Peak oxygen consumption (range: ­3% to + 61%) increased in three, and oxygen pulse (range: ­7% to + 44%) in four of five patients. The quality of life assessment indicated better well-being in all participants. NT-ProBNP (+233 to ­733 ng/ml) and the inflammatory biomarkers (hsCRP and IL6) decreased in four of five patients (IL 6: +0.5 to ­2 mg/l, hsCRP: +0.2 to ­6.5 mg/l). CONCLUSIONS: Robot-assisted gait therapy with the Lokomat® System is feasible in heart failure patients and was safe in this trial. The combined aerobic and resistance training intervention with augmented feedback resulted in benefits in exercise capacity, muscle strength and quality of life, as well as an improvement of cardiac (NT-ProBNP) and inflammatory (IL6, hsCRP) biomarkers. Results can only be considered as preliminary and need further validation in larger studies. (ClinicalTrials.gov number, NCT 02146196)


Subject(s)
Exercise Therapy/methods , Exercise Tolerance/physiology , Gait/physiology , Heart Failure/rehabilitation , Resistance Training/methods , Robotics/methods , Ventricular Function, Left , Aged , Female , Follow-Up Studies , Heart Failure/physiopathology , Humans , Male , Middle Aged , Muscle Strength/physiology , Oxygen Consumption/physiology , Pilot Projects , Prospective Studies , Quality of Life , Treatment Outcome
15.
J Card Surg ; 30(7): 574-80, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25998717

ABSTRACT

BACKGROUND: To assess feasibility and safety of a robot-assisted gait therapy with the Lokomat® system in patients early after open heart surgery. METHODS: Within days after open heart surgery 10 patients were subjected to postoperative Lokomat® training (Intervention group, IG) whereas 20 patients served as controls undergoing standard postoperative physiotherapy (Control group, CG). All patients underwent six-minute walk test and evaluation of the muscular strength of the lower limbs by measuring quadriceps peak force. The primary safety end-point was freedom from any device-related wound healing disturbance. Patients underwent clinical follow-up after one month. RESULTS: Both training methods resulted in an improvement of walking distance (IG [median, interquartile range, p-value]: +119 m, 70-201 m, p = 0.005; CG: 105 m, 57-152.5m, p < 0.001) and quadriceps peak force (IG left: +5 N, 3.8 7 N, p = 0.005; IG right: +3.5 N, 1.5-8.8 N, p = 0.011; CG left: +5.5 N, 4-9 N, p < 0.001; CG right: +6 N, 4.3-9.8 N, p < 0.001) in all participants. Results with robot-assisted training were comparable to early postoperative standard in hospital training (median changes in walking distance in percent, p = 0.81; median changes in quadriceps peak force in percent, left: p = 0.97, right p = 0.61). No deep sternal wound infection or any adverse event occurred in the robot-assisted training group. CONCLUSIONS: Robot-assisted gait therapy with the Lokomat® system is feasible and safe in patients early after median sternotomy. Results with robot-assisted training were comparable to standard in hospital training. An adapted and combined aerobic and resistance training intervention with augmented feedback may result in benefits in walking distance and lower limb muscle strength (ClinicalTrials.gov number, NCT 02146196).


Subject(s)
Cardiac Surgical Procedures/rehabilitation , Gait/physiology , Physical Therapy Modalities , Robotics/methods , Sternotomy/rehabilitation , Walking/physiology , Aged , Feasibility Studies , Feedback, Physiological/physiology , Follow-Up Studies , Humans , Middle Aged , Muscle Strength/physiology , Postoperative Period , Quadriceps Muscle/physiology , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...