Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 29(6): 8108-8116, 2021 Mar 15.
Article in English | MEDLINE | ID: mdl-33820263

ABSTRACT

The measurement of distance plays an important role in many aspects of modern societies. In this paper, an absolute distance measurement method for arbitrary distance is proposed and demonstrated using mode-resolved spectral interferometry with a gain-switched dual comb. An accuracy of 12 µm, when compared to a He-Ne fringe counting laser interferometer, for a displacement up to 2.5 m is demonstrated by tuning the repetition frequency of the dual comb from 1.1 GHz to 1.4 GHz. The compact measurement system based on a gain-switched dual comb breaks the constraint of periodic ambiguity. The simplification and improvements are significant for further industrial applications.

2.
Opt Express ; 28(11): 16900-16906, 2020 May 25.
Article in English | MEDLINE | ID: mdl-32549503

ABSTRACT

A monolithically integrated dual-channel optical frequency comb source is demonstrated in this paper. Three lasers are integrated on a single chip using a regrowth-free fabrication process in a master-slave-slave configuration. The master laser's power is split equally using a 1x2 multimode interference coupler and injection locks the two slave lasers. The slave lasers are gain-switched to produce dual optical frequency combs at 4.1 GHz and 5 GHz. To the best of our knowledge, this is the first demonstration of a dual optical frequency comb source with all light sources monolithically integrated in a photonic integrated circuit (PIC).

3.
Sensors (Basel) ; 19(23)2019 Nov 28.
Article in English | MEDLINE | ID: mdl-31795087

ABSTRACT

A custom-designed gain-switched frequency comb (GSFC) source was passively coupled to a medium finesse (F ≈ 522) cavity in off-axis configuration for the detection of ammonia (14NH3) in static dry air. The absorption of ammonia was detected in the near infrared spectral region between 6604 and 6607 cm-1 using a Fourier transform detection scheme. More than 30 lines of the GSFC output (free spectral range 2.5 GHz) overlapped with the strongest ro-vibrational ammonia absorption features in that spectral region. With the cavity in off-axis configuration, an NH3 detection limit of ∼3.7 ppmv in 20 s was accomplished in a laboratory environment. The experimental performance of the prototype spectrometer was characterized; advantages, drawbacks and the potential for future applications are discussed.

4.
Opt Express ; 27(12): 16560-16570, 2019 Jun 10.
Article in English | MEDLINE | ID: mdl-31252880

ABSTRACT

A novel scheme for the expansion and phase correlation of a wavelength tunable gain-switched optical frequency comb (OFC) is presented. This method entails firstly combining two gain-switched OFCs and expanding them using a phase modulator. Subsequently, the phase correlation between all the comb lines is induced through four-wave mixing (FWM) in a semiconductor optical amplifier (SOA). In this article, the generation of 42 highly correlated comb lines separated by 6.25 GHz, with an optical carrier to noise ratio (OCNR) of more than 50 dB, is experimentally demonstrated. In addition, the wavelength tunability of the scheme, over 30 nm within the C band, is shown. Finally, the degree of phase correlation between comb lines is verified through RF beat tone linewidth measurements. The results show a five orders of magnitude reduction in the beat tone linewidth, due to FWM in an SOA.

SELECTION OF CITATIONS
SEARCH DETAIL
...