Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 201
Filter
1.
JBJS Rev ; 12(7)2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38968372

ABSTRACT

¼ The demographic profile of candidates for total knee arthroplasty (TKA) is shifting toward younger and more active individuals.¼ While cemented fixation remains the gold standard in TKA, the interest is growing in exploring cementless fixation as a potentially more durable alternative.¼ Advances in manufacturing technologies are enhancing the prospects for superior long-term biological fixation.¼ Current research indicates that intermediate to long-term outcomes of modern cementless TKA designs are comparable with traditional cemented designs.¼ The selection of appropriate patients is critical to the success of cementless fixation techniques in TKA.¼ There is a need for high-quality research to better understand the potential differences and relative benefits of cemented vs. cementless TKA systems.


Subject(s)
Arthroplasty, Replacement, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis , Bone Cements , Prosthesis Design
2.
J Arthroplasty ; 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38830432

ABSTRACT

BACKGROUND: Genetics play an important role in several medical domains; however, the influence of human leukocyte antigen (HLA) genotype on the development of periprosthetic joint infection (PJI) in total hip arthroplasty (THA) remains unknown. The primary aim of this study was to determine if HLA genotype is associated with the development of bacterial PJI in THA. Secondarily, we evaluated the association between HLA genotype and PJI treatment success. METHODS: A retrospective, matched, case-control study was performed using prospectively collected data from a single institution. A total of 49 patients who underwent primary THA were included, with a mean follow-up of 8.5 years (range, 4.2 to 12.9). The 23 cases (PJI) and 26 controls (no PJI) were matched for age, sex, follow-up, body mass index, primary diagnosis, and comorbidities (P > .05). High-resolution genetic analysis targeting 11 separate HLA loci was performed in all patients using serum samples. The HLA gene frequencies and carriage rates were determined and compared between cohorts. A subgroup analysis of PJI treatment success (18) and failure (5) was performed. Statistical significance was set at P = .10 for genetic analysis and at 0.05 for all other analyses. RESULTS: There were 4 HLA alleles that were significantly associated with the development of PJI. The 3 at-risk alleles included HLA-C∗06:02 (odds ratio 5.25, 95% CI [confidence interval] 0.96 to 28.6, P = .064), HLA-DQA1∗04:01 (P = .096), and HLA-DQB1∗04:02 (P = .096). The single protective allele was HLA-C∗03:04 (odds ratio 0.12, 95% CI 0.01 to 1.10, P = .052). There were no specific HLA alleles that were associated with treatment success or failure. CONCLUSIONS: This study suggests that there are at-risk and protective HLA alleles associated with the development of PJI in THA. To our knowledge, this is the first study to demonstrate an association between patient HLA genotype and the development of PJI. A larger study of the subject matter is necessary and warranted.

3.
Article in English | MEDLINE | ID: mdl-38907059

ABSTRACT

BACKGROUND: Manipulation under anesthesia (MUA) is a well-established treatment for stiffness after total knee arthroplasty (TKA). Risk factors for failure of MUA remain largely unknown. The primary aim of this study was to identify risk factors for failure of MUA after TKA. METHODS: We performed a retrospective cohort study including 470 patients who underwent MUA after primary TKA with minimum 2 year follow-up. Patients were grouped into success (n = 412) or failure (n = 58) cohorts; failure was defined as flexion < 90° at most recent follow-up or revision for stiffness. The increase in flexion post-MUA for the cohort was calculated. Several clinical, patient, and surgical factors were analyzed using univariate, followed by multivariable logistic regression models to identify independent risk factors associated with failure. RESULTS: The mean increase in flexion was 42° (range 0-115). BMI 30-35 (p = 0.01, odds ratio (OR) 2.42; 95% CI 1.25-4.68) and poorer pre-MUA flexion (p < 0.01, OR 1.43; 95% CI 1.23-1.67) were risk factors for failure. When considering revision for stiffness only, BMI 30-35 (p = 0.01, OR 3.27; 95% CI 1.41-7.61), lower pre-MUA flexion (p < 0.01, OR 1.43; 95% CI 1.18-1.75), and history of prior knee surgery (p = 0.04, OR 2.31; 95% CI 1.06-5.04) were predictors of failure. Time to MUA (p = 0.48), thromboprophylaxis (p = 0.44), pre-operative opioid use (p = 0.34), depression/anxiety (p = 1.0), and several other factors analyzed were not associated with failure. CONCLUSION: In this large cohort, elevated BMI and lower pre-MUA flexion were risk factors for failure of MUA. History of prior knee surgery was an additional predictor of requiring revision for stiffness.

4.
J Bone Joint Surg Am ; 2024 May 30.
Article in English | MEDLINE | ID: mdl-38815006

ABSTRACT

BACKGROUND: The Wagner Cone Prosthesis was designed to address complex femoral deformities during total hip arthroplasty (THA), but its mid-term component survivorship and functional outcomes remain undetermined. The objectives of this study were to determine the implant survivorship, patient satisfaction, functional outcomes, osseointegration as seen radiographically, implant subsidence, and complications of THA using the Wagner Cone Prosthesis stem at intermediate-term follow-up. METHODS: This study involved 302 patients with proximal femoral deformities, including developmental hip dysplasia and Legg-Calvé-Perthes disease, who underwent a total of 320 primary THAs using the Wagner Cone Prosthesis. The average age at the time of surgery was 49.4 ± 14.5 years (range, 18.8 to 85.6 years). Patient satisfaction was recorded using a self-administered questionnaire assessing satisfaction in 4 domains. The University of California at Los Angeles (UCLA) activity score, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Oxford Hip Score (OHS), the Forgotten Joint Score (FJS), radiographic outcomes, and complications were recorded. The mean follow-up time was 10.1 years (range, 5.2 to 15.5 years). RESULTS: Survivorship of the Wagner Cone Prosthesis was 98.7% (95% confidence interval [CI]: 97.2% to 100%) with stem revision as the end point and 95.8% (95% CI: 93.5% to 98.2%) with reoperation for any reason as the end point at 10 years postoperatively. In total, 3 stems were revised: 2 for infection and 1 for chronic hip dislocation. The median patient satisfaction score was 95 (interquartile range [IQR], 80 to 100), median UCLA score was 6 (IQR, 6 to 7), median WOMAC score was 18 (IQR, 16 to 22), median OHS was 40 (IQR, 36 to 47), and median FJS was 80 (IQR, 76 to 88) at the time of final follow-up. All Wagner Cone stems that were not revised showed radiographic evidence of osseointegration, with a mean stem subsidence of 0.9 ± 0.8 mm at the most recent follow-up. CONCLUSIONS: The use of the Wagner Cone Prosthesis stem in patients with complex femoral anatomy undergoing primary THA is associated with excellent component survivorship, high levels of patient satisfaction, good functional outcomes, and reliable osseointegration with minimal stem subsidence as seen on radiographs at intermediate-term follow-up. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

5.
Bone Joint J ; 106-B(5 Supple B): 112-117, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38688497

ABSTRACT

Aims: There are limited long-term studies reporting on outcomes of the Zimmer Modular Revision (ZMR) stem, and concerns remain regarding failure. Our primary aim was to determine long-term survival free from all-cause revision and stem-related failure for this modular revision stem in revision total hip arthroplasty (THA). Secondary aims included evaluating radiological and functional outcomes. Methods: We retrospectively identified all patients in our institutional database who underwent revision THA using the ZMR system from January 2000 to December 2007. We included 106 patients (108 hips) with a mean follow-up of 14.5 years (2.3 to 22.3). Mean patient age was 69.2 years (37.0 to 89.4), and 51.9% were female (n = 55). Indications for index revision included aseptic loosening (73.1%), infection (16.7%), fracture (9.3%), and stem fracture (0.9%). Kaplan-Meier analysis was used to determine the all-cause and stem-related failure revision-free survival. At most recent follow-up, Oxford Hip Scores (OHS) were collected, and radiological stem stability was determined using the Engh classification. Results: A total of 17 hips (15.7%) underwent re-revision of any component. Indications for re-revision were stem failure (35.3%; n = 6), infection (29.4%; n = 5), instability (29.4%; n = 5), and acetabular aseptic loosening (5.9%; n = 1). The five- and 15-year all-cause survival was 89.7% (95% confidence interval (CI) 86.7 to 92.7) and 83.3% (95% CI 79.6 to 87.0), respectively. There were six re-revisions (5.6%) for stem failure; five for stem fracture and one for aseptic loosening. The five- and 15-year survival free from stem-related failure was 97.2% (95% CI 95.6 to 98.8) and 94.0% (95% CI 91.6 to 96.4), respectively. At final follow-up, the mean OHS was 36.9 (8.0 to 48.0) and 95.7% (n = 66) of surviving modular revision stems were well-fixed in available radiographs. Conclusion: Femoral revision with the ZMR offers satisfactory long-term all-cause revision-free survival, good survival free of stem-related failure, and favourable clinical outcomes. Stem fracture was the most common reason for stem-related failure and occurred both early and late. This highlights the importance of both early and long-term surveillance for stem-related failure.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Prosthesis Design , Prosthesis Failure , Reoperation , Humans , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Female , Reoperation/statistics & numerical data , Aged , Male , Retrospective Studies , Middle Aged , Aged, 80 and over , Adult , Follow-Up Studies , Treatment Outcome , Kaplan-Meier Estimate
6.
Ann Jt ; 9: 4, 2024.
Article in English | MEDLINE | ID: mdl-38529292

ABSTRACT

Patient and implant selection is essential to optimize outcome. Femoral bone loss classifications such as the American Academy of Orthopaedic Surgeons, Gross, and Paprosky classifications permit surgeons to systematically manage bone stock deficiencies and guide implant selection. Here we provide a comprehensive report on the pitfalls and management of this reconstructive challenge. Preoperative planning remains vital to the treatment of femoral bone loss in revision hip arthroplasty and the authors believe it is essential and should include the entire femur. This commonly includes imaging for bone loss such as Judet views or computed tomography scan and must include the entire femur though additional radiographs such as Judet views apply more for acetabular bone loss as opposed to femoral bone loss. All patients should have pre-operative work up to exclude infection. If any of these results area elevated, an aspirate and sampling is required to guide microbiological management. Classically with regards femoral revision surgery, uncemented fixation has proven to give the best outcomes but surgeons must remain flexible and use cemented fixation when necessary. Adequate proximal bone stock permits the use of implants used in primary joint surgery. Implants with proximal modularity can be used in cases where bone stock allows for superb proximal bone support. The vast majority of femoral revisions have inadequate proximal bone stock, thus distally fixed stems should be used and have been shown to provide both axial and rotational stability provided there is an intact isthmus. Taper fluted stems can provide good outcomes even in cases of major bone loss. However, with severe bony loss, impaction grating or the use of a megaprotsthesis is sometimes necessary and is down to surgeon choice and preference. This article has been written as a guide for management and summarises the best evidence available.

7.
J Arthroplasty ; 2024 Mar 18.
Article in English | MEDLINE | ID: mdl-38508344

ABSTRACT

BACKGROUND: Porous tantalum metaphyseal cones may facilitate reconstructions of severe bone defects during revision total knee arthroplasty (TKA), but there remains a paucity of data on their outcomes at mean 5 years of follow-up. This study reports the component survivorship, patient satisfaction, functional outcomes, radiographic osseointegration, and complications of revision TKA with porous tantalum metaphyseal cones at mid-term (mean 5-year) follow-up. METHODS: This study included 152 patients who had a mean age of 66 years (range, 33 to 86 years) undergoing revision TKA with porous tantalum metaphyseal cones. Indications for surgery included aseptic loosening (n = 87, 57.3%), second-stage reimplantation for infection (n = 42, 27.6%), osteolysis with well-fixed components (n = 20, 13.2%), and periprosthetic fracture (n = 3, 2.0%). Component survivorship, clinical outcomes, radiographic outcomes, and any complications were recorded. The mean follow-up time was 5.6 years (range, 2.2 to 13.7). RESULTS: Survivorship was 100% when the end point was revision of the metaphyseal cone (no cones were revised) and 83.8% (95% confidence interval: 77.9 to 90.2%) when the end point was reoperation for any reason at 5-year follow-up. Reoperations were performed for infection (n = 10), instability (n = 4), periprosthetic fracture (n = 2), and quadriceps rupture/dehiscence (n = 3). The mean patient satisfaction score was 78.8 ± 11.3 and the mean Forgotten Joint Score was 62.2 ± 16.7 at the final follow-up. The preoperative median University of California at Los Angeles score improved from 2 (interquartile range 2 to 3) to 6 points (interquartile range 5 to 6) (P < .001), and the preoperative Oxford knee score improved from 15.2 ± 3.8 to 39.4 ± 5.1 points (P < .001) at the final follow-up. All metaphyseal cones showed radiographic evidence of osteointegration without any subsidence or loosening. CONCLUSIONS: Porous tantalum metaphyseal cones enabled robust reconstructions of severe femoral and tibial bone defects during revision TKA. These reconstructions were associated with excellent survivorship, improvements in functional outcomes, and reproducible radiographic osseointegration at mean 5-year follow-up. The most common reasons for reoperation were infection and instability.

8.
J Arthroplasty ; 2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38336304

ABSTRACT

BACKGROUND: There is a paucity of literature regarding the mid-term (greater than 2 years) outcomes of revision for adverse local tissue reaction to metal debris due to corrosion at the head-neck junction (trunnionosis) in metal-on-polyethylene total hip arthroplasty (THA), and risk factors for re-revision remain largely unknown. We aimed to report the re-revision-free survival and functional outcomes for this patient population and to identify risk factors for re-revision. METHODS: A total of 80 hips (79 patients) with a metal-on-polyethylene THA who had undergone revision for trunnionosis at our institution were included. The mean study follow-up from index trunnionosis revision was 4.6 years (range, 2.0 to 9.4). Kaplan-Meier survival analysis was performed with all-cause re-revision as the end point, and multivariate logistic regression was used to identify risk factors for re-revision. RESULTS: We saw that twenty-one hips (26%) underwent re-revision at a mean of 8.0 months (range, 0.03 to 36.3) after the index trunnionosis revision, most commonly for instability and infection. The two- and five-year all-cause re-revision-free survival rates were 75.0 and 73.2%, respectively. The mean Oxford Hip Score was 33.7 (range, 11 to 48); 76% were satisfied, and 24% were dissatisfied with their hip. Multivariate analysis identified not undergoing a cup revision (odds ratio: 4.5; 95% confidence interval: 1.03 to 19.7) and time from primary THA to the index trunnionosis revision (odds ratio: 0.77; 95% confidence interval: 0.62 to 0.97) as risk factors for undergoing re-revision. CONCLUSIONS: The risk of early re-revision for these patients is high (26%), mostly due to infection and instability, and functional outcomes are fair. Not performing a cup revision appears to be a risk factor for re-revision, as is the shorter time from primary THA to trunnionosis revision. LEVEL OF EVIDENCE: III.

9.
Orthop Clin North Am ; 55(2): 181-192, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38403365

ABSTRACT

Although one-stage exchange arthroplasty is gaining popularity, two-stage exchange arthroplasty remains the gold standard for the treatment of periprosthetic joint infections. Use of an articulating spacer for this procedure offers an avenue for maintaining hip motion and controlled weight-bearing, allowing local antibiotic elution. However, there is no uniform consensus on the optimal surgical protocol for using articulating spacers. This review describes the surgical technique for undertaking a first-stage exchange arthroplasty using an articulating spacer and discusses the pertinent literature on key concepts relating to periprosthetic joint infections in total hip arthroplasty to guide effective surgical decision making in these patients.


Subject(s)
Arthritis, Infectious , Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Prosthesis-Related Infections , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Reoperation/methods , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/surgery , Prosthesis-Related Infections/drug therapy , Anti-Bacterial Agents/therapeutic use , Arthroplasty, Replacement, Knee/methods , Treatment Outcome , Retrospective Studies
10.
J Orthop ; 50: 99-110, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38187368

ABSTRACT

Background: Recent evidence on the cost-effectiveness of technology in total knee arthroplasty (TKA) demonstrated that navigated computer-assisted methods (N-TKA) is likely to be most cost-effective in the clinical setting. The aim of the current meta-analysis is to compare radiographic, clinical and functional outcomes between conventional TKA (C-TKA) and N-TKA methods. Methods: All prospective randomized controlled trials (pRCTs) comparing primary TKA performed using C-TKA and N-TKA techniques were eligible for inclusion. Radiographic outcomes included postoperative coronal, sagittal and axial component alignment. Clinical outcomes included all-cause revision and aseptic revision. Functional outcomes were analyzed when reported. A random-effects meta-analysis of all available cases was performed. This allowed for all missing data. Results: Normal coronal mechanical alignment of the tibial (p < 0.001) and femoral (p = 0.001) components was achieved more frequently with N-TKA. Normal sagittal mechanical alignment of the tibial component was achieved significantly more with N-TKA (p < 0.010). There was no difference in short-term clinical survivorship (all-cause, p = 0.649; aseptic, p = 0.79) or in functional outcomes reported between groups. There was a clinically significant reduction in the mean C-TKA operative time (87 min, σ = 16.6, 95% CI 76.4-98.8) compared N-TKA (97.6 min, σ = 16.9, 95% CI 86.2-109.1) (p = 0.17). Conclusion: Navigated TKA achieves superior radiographic alignment for femoral and tibial components in both the coronal and sagittal plane. Operative times are 10 min longer in the N-TKA group. Functional outcomes are similar between navigated and conventional groups. Clinical outcomes reported in Level I studies are limited to short-term follow-up so future prospective studies are required.

11.
J Arthroplasty ; 39(1): 206-210, 2024 01.
Article in English | MEDLINE | ID: mdl-37331438

ABSTRACT

BACKGROUND: Aseptic lymphocyte-dominated vasculitis-associated lesions (ALVALs) are typically described in the context of metal-on-metal (MoM) hip bearings. This study explores the diagnostic utility of preoperative serum cobalt and chromium ion levels in determining the histological grade of ALVAL in revision hip and knee arthroplasty. METHODS: This was a multicenter retrospective review of 26 hips and 13 knees assessing the correlation between preoperative ion levels (mg/L (ppb)) and the histological grade of ALVAL from intraoperative specimens. The diagnostic ability of preoperative serum cobalt and chromium levels to determine high-grade ALVAL was assessed using a receiver operating characteristic (ROC) curve. RESULTS: In the knee cohort, there was a higher serum cobalt level in high-grade ALVAL cases (10.2 mg/L (ppb) versus 3.1 mg/L (ppb)) (P = .0002). The Area Under the Curve (AUC) was 1.00 (95% confidence interval (CI) 1.00 to 1.00). There was a higher serum chromium level in high-grade ALVAL cases (12.25 mg/L (ppb) versus 7.77 mg/L (ppb)) (P = .0002). The AUC was 0.806 (95% CI 0.555 to 1.00). In the hip cohort, there was a higher serum cobalt level in high-grade ALVAL cases (333.5 mg/L (ppb) versus 119.9 mg/L (ppb)) (P = .0831). The AUC was 0.619 (95% CI 0.388 to 0.849). There was a higher serum chromium level in high-grade ALVAL cases (186.4 mg/L (ppb) versus 79.3 mg/L (ppb)) (P = .183). The AUC was 0.595 (95% CI 0.365 to 0.824). CONCLUSIONS: Histologically, high-grade ALVAL has significantly higher preoperative serum cobalt and chromium ion levels in revision TKA. Preoperative serum ion levels have excellent diagnostic utility in revision TKA. Cobalt levels in revision THA have a fair diagnostic ability and chromium levels had a poor diagnostic ability.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Vasculitis , Humans , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Metals , Cobalt , Chromium , Lymphocytes , Biomarkers , Vasculitis/diagnosis , Vasculitis/pathology , Prosthesis Design , Metal-on-Metal Joint Prostheses/adverse effects , Prosthesis Failure
12.
Arthroplast Today ; 24: 101274, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38077926

ABSTRACT

Background: With notable benefits in reducing length of stay (LOS), this study aimed to quantify the temporal trend and the factors contributing to increased LOS for primary and revision total hip (THA and rTHA) and knee (TKA and rTKA) arthroplasty. The study was carried out for a large population-based cohort over a 20-year period. Methods: This was a retrospective population-based study assessing the LOS for all primary and revision THA and TKA procedures between 2003 and 2022. The primary outcome of interest was LOS. Univariate and multivariate analyses were performed to identify associated variables. Results: For the entire dataset, there were 16,677 primary THAs, 13,018 primary TKAs, 3276 (aseptic) rTHAs, 1445 (aseptic) rTKAs, 820 (septic) rTHAs, and 667 (septic) rTKAs. The median LOS over the 20-year period between 2003 and 2022 demonstrated a steady and continuous decline from a median of 5 days (interquartile range 3-7) in 2003 to 1 day (interquartile range 1-2) in 2022. On multivariate analysis, there were a number of factors associated with increasing LOS: year of procedure (P < .0001), procedure type (P < .0001), age (P < .0001), and American Society of Anesthesiologists class (P < .0001). On multivariate analysis, body mass index was not associated with increased LOS (P = .5631). Conclusions: There was a downward trend in LOS for all types of primary and revision THA and TKA. The factors contributing most to a reduction in LOS include the year the procedure was performed, primary THA procedures, aseptic (vs periprosthetic joint infection) revision procedures, younger age, and lower American Society of Anesthesiologists classes.

13.
JBJS Case Connect ; 13(4)2023 Oct 01.
Article in English | MEDLINE | ID: mdl-38096339

ABSTRACT

CASE: There is an increasing emphasis on adverse reactions to metal debris around prosthetic hip implants. We present a case report of a patient with increasing pain around a previous total hip arthroplasty and magnetic resonance imaging findings consistent with a pseudotumor. Serum metal ion levels were not elevated and initial biopsy findings inconclusive. The patient was diagnosed with an extraskeletal chondrosarcoma after revision total hip arthroplasty and subsequently underwent external hemipelvectomy with negative margins. CONCLUSION: This report highlights the importance of remaining vigilant for malignant sarcomas presenting as pseudotumors around hip replacements, particularly in the absence of abnormal metal ion levels or definitive biopsy results.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Sarcoma , Humans , Arthroplasty, Replacement, Hip/adverse effects , Cobalt , Hip Prosthesis/adverse effects , Metal-on-Metal Joint Prostheses/adverse effects , Metals/adverse effects , Prosthesis Design , Sarcoma/diagnosis , Sarcoma/etiology , Sarcoma/surgery , Diagnosis, Differential
14.
Orthop Clin North Am ; 54(4): 407-415, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37718080

ABSTRACT

Cannabis use among the elderly has increased over the previous 2 decades. This has translated to a greater proportion of orthopedic procedures being undertaken on these patients. This review provides clinicians with evidence-based information on the effects of cannabis on pain control in THA and TKA, to help counsel these patients and facilitate their perioperative management. The review specifically focuses on the following: origins of cannabis; biochemistry of cannabis; medical versus recreational cannabis; pharmacology of cannabis; effects of cannabis on bone metabolism; preoperative pain control; preoperative systemic considerations; intraoperative considerations; postoperative pain control, postoperative systemic considerations; and scope for future work.


Subject(s)
Arthroplasty, Replacement, Knee , Cannabis , Orthopedic Procedures , Aged , Humans , Arthroplasty, Replacement, Knee/adverse effects , Pain Management , Pain
15.
J Am Acad Orthop Surg ; 31(19): e746-e759, 2023 Oct 01.
Article in English | MEDLINE | ID: mdl-37364252

ABSTRACT

As the number of total knee arthroplasties performed continues to increase, complications such as postoperative periprosthetic fractures are becoming increasingly more common. Femoral periprosthetic fractures are the most common type of fractures around a total knee arthroplasty, whereas tibial and patellar periprosthetic fractures are infrequent. Treatment principles depend on the bone the fracture is located, the status of the implant fixation, bone stock, and the type of implants available. The Vancouver classification allows for a standardized system to describe and manage these injuries, incorporating these factors. A systematic approach is vital in obtaining the best possible outcomes because complications and mortality rates mimic those of hip fractures.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Femoral Fractures , Hip Fractures , Periprosthetic Fractures , Humans , Periprosthetic Fractures/etiology , Periprosthetic Fractures/surgery , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Femoral Fractures/etiology , Femoral Fractures/surgery , Hip Fractures/surgery , Fracture Fixation, Internal/adverse effects , Reoperation/adverse effects , Retrospective Studies
16.
Front Surg ; 10: 1104603, 2023.
Article in English | MEDLINE | ID: mdl-37139190

ABSTRACT

Tourniquet use is common practice in many millions of orthopaedic procedures annually. Recent reviews of risks and benefits of surgical tourniquet use have primarily involved meta-analyses, many of which have forgone a comprehensive risk-benefit analysis to simply question whether "tourniquet or no tourniquet" use produces improved patient outcomes, often leading to limited, inconclusive, or conflicting results. To investigate further, a pilot survey was undertaken to determine current practices, opinions, and understandings among orthopaedic surgeons in Canada regarding use of surgical tourniquets in total knee arthroplasties (TKAs). Results of the pilot survey showed a wide range of understanding and practice associated with tourniquet use in TKAs, especially regarding tourniquet pressures and tourniquet times, two key factors known from basic research and clinical studies to impact the safety and efficacy of tourniquet use. The wide variation of use indicated by the survey results reveals important implications for surgeons, researchers, educators, and biomedical engineers, to better understand the association between key tourniquet parameters and outcomes assessed in research, which may be factors leading to their often limited, inconclusive, and conflicting results. Lastly, we provide an overview of the overly simplified assessments of tourniquet use in meta-analyses, whose conclusions may not provide an understanding of how or whether key tourniquet parameters might be optimized to retain the benefits of tourniquet use while mitigating the associated real or perceived risks.

17.
Bone Jt Open ; 4(3): 182-187, 2023 Mar 14.
Article in English | MEDLINE | ID: mdl-37051827

ABSTRACT

Hip resurfacing remains a potentially valuable surgical procedure for appropriately-selected patients with optimised implant choices. However, concern regarding high early failure rates continues to undermine confidence in use. A large contributor to failure is adverse local tissue reactions around metal-on-metal (MoM) bearing surfaces. Such phenomena have been well-explored around MoM total hip arthroplasties, but comparable data in equivalent hip resurfacing procedures is lacking. In order to define genetic predisposition, we performed a case-control study investigating the role of human leucocyte antigen (HLA) genotype in the development of pseudotumours around MoM hip resurfacings. A matched case-control study was performed using the prospectively-collected database at the host institution. In all, 16 MoM hip resurfacing 'cases' were identified as having symptomatic periprosthetic pseudotumours on preoperative metal artefact reduction sequence (MARS) MRI, and were subsequently histologically confirmed as high-grade aseptic lymphocyte-dominated vasculitis-associated lesions (ALVALs) at revision surgery. 'Controls' were matched by implant type in the absence of evidence of pseudotumour. Blood samples from all cases and controls were collected prospectively for high resolution genetic a nalysis targeting 11 separate HLA loci. Statistical significance was set at 0.10 a priori to determine the association between HLA genotype and pseudotumour formation, given the small sample size. Using a previously-reported ALVAL classification, the majority of pseudotumour-positive caseswere found to have intermediate-grade group 2 (n = 10; 63%) or group 3 (n = 4; 25%) histological findings. Two further patients (13%) had high-grade group 4 lesions. HLA-DQB1*05:03:01 (p = 0.0676) and HLA-DRB1*14:54:01 (p = 0.0676) alleles were significantly associated with a higher risk of pseudotumour formation, while HLA-DQA1*03:01:01 (p = 0.0240), HLA-DRB1*04:04:01 (p = 0.0453), HLA-C*01:02:01 (p = 0.0453), and HLA-B*27:05:02 (p = 0.0855) were noted to confer risk reduction. These findings confirm the association between specific HLA genotypes and the risk of pseudotumour development around MoM hip resurfacings. Specifically, the two 'at risk' alleles (DQB1*05:03:01 and DRB1*14:54:01) may hold clinical value in preoperative screening and prospective surgical decision-making.

18.
Ir J Med Sci ; 192(6): 2851-2858, 2023 Dec.
Article in English | MEDLINE | ID: mdl-36928594

ABSTRACT

We present key information from international registries in relation to primary total hip arthroplasty. The specific questions of interest include which bearings are superior in total hip arthroplasty (THA), which fixation types are optimal, do any specific implants perform better than others, and what is the latest update in the hip fracture setting? This is a comprehensive review of the major English-speaking hip arthroplasty registries across the globe. Key trends and developments in implant performance are identified and presented in the current article. Key points from review of all registries confirm that ceramic-on-polyethylene and metal-on-polyethylene continue to be the commonest bearings. The use of cemented femoral stems is increasing across most regions. Hybrid fixation is now the commonest fixation method in the UK for the first time in registry history. Uncemented femoral stems have a higher early revision rate for periprosthetic fracture than cemented stems across most regions. Dual mobility (DM) bearings are increasing in use and show higher early revision rates than unipolar bearings-they tend to be used for more complex indications (fracture/tumor/revision) and show similar revision rates to unipolar bearings when used exclusively in primary elective THA for osteoarthritis. We present current trends in THA based on current registry data from across the globe. Clinical signals of concern are emerging for THA uncemented femoral stem fixation and DM bearings in specific clinical contexts. These signals should be monitored across the literature in order to reduce the overall revision burden.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/methods , Treatment Outcome , Risk Factors , Reoperation , Registries , Polyethylenes , Prosthesis Design , Prosthesis Failure
19.
Eur J Orthop Surg Traumatol ; 33(7): 2729-2735, 2023 Oct.
Article in English | MEDLINE | ID: mdl-36947314

ABSTRACT

INTRODUCTION: International joint registries provide high volumes of information in relation to the performance of total knee arthroplasty on a global scale. Distillation of this data can be challenging, particularly with the establishment of more arthroplasty registries on a yearly basis. We therefore aim to present key information from these registries in relation to primary total knee arthroplasty. The specific questions of interest include: Which fixation type is superior in TKA? Does the level of constraint impact on clinical performance? How do partial knee replacements perform in the registries? Does patellar resurfacing lead to superior results? Are there any specific implants which perform particularly well or poorly? METHODS: A comprehensive review of the major English-speaking knee arthroplasty registries across the globe was performed. Given the expanding large number of registries worldwide, it was not possible to perform a comprehensive review of all registries and so, a detailed review of the major English-speaking knee arthroplasty registries was included. Key trends and developments in implant performance were identified and presented in the current article. RESULTS: Total knee replacements have lower revision rates than both unicompartmental and patellofemoral joint replacement procedures. Patellofemoral joint replacements have the highest failure rate of all knee replacement procedures. Cruciate-Retaining (CR) TKR designs have superior outcomes to Posterior-Stabilized (PS) designs across all registries. Patellar resurfacing appears to confer an advantage over non-resurfaced patellas in primary TKR. CONCLUSION: We present current global trends in the utility and performance of TKA based on data from English-speaking arthroplasty registries.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Patella/surgery , Reoperation , Registries , Knee Joint/surgery , Osteoarthritis, Knee/surgery
20.
J Arthroplasty ; 38(6S): S275-S280, 2023 06.
Article in English | MEDLINE | ID: mdl-36739924

ABSTRACT

BACKGROUND: Revisions of total knee arthroplasties (TKAs) may require revision of one or both tibial and femoral components. Our purpose was to examine the clinical and functional outcomes in 1- versus 2-component TKA revisions. METHODS: We identified 92 1-component (tibial or femoral) revisions at a single center. Our inclusion criteria were isolated revision of the tibial or femoral components with a minimum 2-year follow-up. The included cases were matched 1:2 with a control group of 2-component revisions (tibial and femoral) by age, body mass index, American Society of Anesthesiologists score, and indication for revision. We collected demographics, complications, operative times, any subsequent rerevisions, and functional outcome scores. RESULTS: The median follow-up time for the 1- and 2-component revision groups were 10 years (range, 3 to 17) and 8 years (range, 2 to 18), respectively. The most common complication after rerevision in both groups was stiffness at 9 of 92 (9.8%) and 9 of 170 (5.3%) in the 1- and 2-component groups, respectively (P = .20). The overall complication prevalence in the 1- and 2- component revision groups was similar 20 of 92 (22%) and 35 of 170 (21%), respectively (P = .87). Subsequent rerevisions for any indication were encountered in 12 of 92 (13.0%) of the 1-component and 18 of 170 (11%) in the 2-component groups (P = .69). There was no statistical difference in survivorship or functional outcomes scores between the groups. CONCLUSION: Our results showed that isolated revision of a single TKA component is an acceptable option, with comparable functional outcomes, complications, and survivorships when compared with both-component revision. As such, a 1-component revision should be considered where appropriate.


Subject(s)
Arthroplasty, Replacement, Knee , Humans , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Knee Joint/surgery , Knee Prosthesis/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/surgery , Prosthesis Design , Prosthesis Failure , Reoperation/adverse effects , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...