Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
J Hazard Mater ; 478: 135491, 2024 Oct 05.
Article in English | MEDLINE | ID: mdl-39182291

ABSTRACT

Due to adverse effects of viral outbreaks on human health, accurate detection of airborne pathogens is essential. Among many methods available for bioaerosol sampling, electrostatic precipitation (ESP) has been used to directly collect bioaerosols as hydrosols. The performance of an ESP sampler depends on its design, operational and environmental parameters such as air relative humidity (RH), air temperature, sampling liquid type and liquid temperature. Thus, it is essential to identify and maintain optimal conditions throughout sampling process to operate the sampler at its highest capacity. This study provides crucial insights into parameters that affect the collection efficiency of the aerosol-to-hydrosol ESP sampler and its virus recovery. The results indicate that air temperature does not affect collection efficiency, meanwhile, air RH, sampling liquid temperature, and salt concentration are the main parameters that significantly affect collection efficiency. Likewise, when deionized water is used as sampling liquid, hydrogen peroxide concentration increases proportionally with increasing air RH, resulting in significant decrease of virus viability. Consequently, for ESP samplers similar to our study, the following conditions are recommended: air RH of 55-65%, air and sampling liquid temperature of 37 °C, and a mixture of 10-20 mM ascorbic acid in PBS as sampling liquid.


Subject(s)
Aerosols , Air Microbiology , Humidity , Static Electricity , Temperature , Environmental Monitoring/methods , Hydrogen Peroxide/chemistry , Viruses/isolation & purification
2.
Biosens Bioelectron ; 234: 115356, 2023 Aug 15.
Article in English | MEDLINE | ID: mdl-37172362

ABSTRACT

The COVID-19 pandemic ignited massive research into the rapid detection of bioaerosols. In particular, nanotechnology-based detection strategies are proposed as alternatives because of issues in bioaerosol enrichment and lead time for molecular diagnostics; however, the practical implementation of such techniques is still unclear due to obstacles regarding the large research and development effort and investment for the validation. The use of adenosine triphosphate (ATP) bioluminescence (expressed as relative luminescence unit (RLU) per unit volume of air) of airborne particulate matter (PM) to determine the bacterial population as a representative of the total bioaerosols (viruses, bacteria, and fungi) has been raised frequently because of the high reponse speed, resolution, and compatibility with culture-based bioaerosol monitoring. On the other hand, additional engineering attempts are required to confer significance because of the size-classified (bioluminescence for different PM sizes) and specific (bioluminescence per unit PM mass) biological risks of air for providing proper interventions in the case of airborne transmission. In this study, disc-type impactors to cut-off aerosols larger than 1 µm, 2.5 µm, and 10 µm were designed and constructed to collect PM1, PM2.5, and PM10 on sampling swabs. This engineering enabled reliable size-classified bioluminescence signals using a commercial ATP luminometer after just 5 min of air intake. The simultaneous operations of a six-stage Andersen impactor and optical PM spectrometers were conducted to determine the correlations between the resulting RLU and colony forming unit (CFU; from the Andersen impactor) or PM mass concentration (deriving specific bioluminescence).


Subject(s)
Biosensing Techniques , COVID-19 , Humans , Adenosine Triphosphate/analysis , Pandemics , Air Microbiology , Biosensing Techniques/methods , COVID-19/diagnosis , Respiratory Aerosols and Droplets , Bacteria , Fungi , Environmental Monitoring/methods , Particle Size
3.
Sci Rep ; 12(1): 6546, 2022 04 21.
Article in English | MEDLINE | ID: mdl-35449225

ABSTRACT

Development of efficient virus aerosol monitoring and removal devices requires aerosolization of the test virus using atomizers. The number concentration and size measurements of aerosolized virus particles are required to evaluate the performance of the devices. Although diffusion dryers can remove water droplets generated using atomizers, they often fail to remove them entirely from the air stream. Consequently, particle measurement devices, such as scanning mobility particle sizer (SMPS), can falsely identify the remaining nanosized water droplets as virus aerosol particles. This in turn affects the accuracy of the evaluation of devices for sampling or removing virus aerosol particles. In this study, a plaque-forming assay combined with SMPS measurement was used to evaluate sufficient drying conditions. We proposed an empirical equation to determine the total number concentration of aerosolized particles measured using the SMPS as a function of the carrier air flow rate and residence time of the particles in the diffusion dryers. The difference in the total number concentration of particles under sufficient and insufficient diffusion drying conditions was presented as a percentage of error.


Subject(s)
Environmental Monitoring , Water , Aerosols/analysis , Nebulizers and Vaporizers , Particle Size
SELECTION OF CITATIONS
SEARCH DETAIL