Appl Radiat Isot ; 188: 110419, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35988526

ABSTRACT

Various thicknesses of 2B grade polymer pencil lead graphite (PPLG) were used in the present study, which focussed on the alteration in crystalline lattice and the structural defect caused by the electron irradiation dosage ranging from 0.5 to 20 Gy delivered by an Elekta HD Linac. The fundamental trap parameters i.e. kinetics order (b), activation energy (E), and frequency factor (s) of the PPLG samples have been estimated using the initial rise and peak shape approaches by fitting the thermoluminescence (TL) glow peaks of the PPLG samples exposed to 20 Gy. The lifetime of the TL glow peak is also presented, which provides information on the stability of the TL signal at maximum temperatures. Raman, Photoluminescence (PL), and X-ray diffraction (XRD) spectra are being used to observe the structural changes that have occurred as a result of the radiation doses. These spectroscopies offer an understanding of the physical parameters that are related to the defects and taking part in the luminescence process. When all of the data are taken into account, it is anticipated that 0.3 mm PPLG is an effective material for dosimetry. The results of these lines of research are intended to educate the innovation of versatile graphite radiation dosimeters as a low-cost efficient system for radiation detection. The studied PPLG offers tissue equivalence as well as high spatial resolution, both are desirable criteria for a material to be used in the monitoring of ionising radiation or a variety of medical applications.


Subject(s)
Graphite , Thermoluminescent Dosimetry , Electrons , Luminescent Measurements , Radiometry , Thermoluminescent Dosimetry/methods
2.
Appl Radiat Isot ; 182: 110141, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35180526

ABSTRACT

The Raman intensity ratio ID/IG for: (a) graphite-rich pencil rods irradiated using x-ray doses up to 20 Gy; (b) a restricted view of the ID/IG response for the same group of media, limited to x-ray doses of no more than 6 Gy; (c1 and c2) an extended group of graphite-rich media irradiated using 60Co gamma-rays; (d) a restricted view of the ID/IG response for a restricted group of the media shown in (c), with 60Co gamma-ray doses limited to no more than 20 Gy; (e) 2B graphite-rich pencil rods irradiated using 6 MeV electrons, and: (f) irradiation of a subset of the media by thermal (0.025 eV) neutrons. The fluctuation of ID/IG with dose for carbon-rich human hair of nominal diameter 60 µm is indicated by the dashed line in (c) and (d). The values in parentheses indicate the percentage carbon content and the surface area-to-volume ratio of samples. The data are a re-organisation of that included in the studies of Abdul Sani et al. (2020, Bradley et al. (2019, 2021), Mat Nawi et al. (2021a,b), and Lam et al. (2021) such as to illustrate three prime dependencies, viz. surface to volume ratio, carbon content, and linear energy transfer, LET. (g) and (h) are combination graphs as indicated in the key to each.

3.
PLoS One ; 16(9): e0258264, 2021.
Article in English | MEDLINE | ID: mdl-34591934

ABSTRACT

[This corrects the article DOI: 10.1371/journal.pone.0235053.].

4.
Appl Radiat Isot ; 174: 109771, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34048992

ABSTRACT

Present study concerns the key thermoluminescence (TL) properties of photonic crystal fibres (PCFs), seeking development of alternatively structured TL materials that are able to offer a advantages over existing passive dosimeters. In terms of their internal structure and light guiding properties the PCFs, collapsed and structured, differ significantly from that of conventional optical fibres. To investigate the dosimetric parameters of the PCFs use was made of a linear accelerator producing a 6 MV photon beam, delivering doses ranging from 0.5 Gy to 8 Gy. The parameters studied included TL response, linearity index, glow curves, relative sensitivity and TL signal fading, the results being compared against those obtained using TLD-100 chips. At 4 Gy photon dose the Ge-doped collapsed PCFs were found to provide a response 27 × that of structured PCF, also giving a TL yield similar to that of standard TLD-100 chips. Over post-irradiation periods of 15 and 30 days collapsed PCF TL signal fading were 8% and 17% respectively, with corresponding values of 37% and 64% for the structured PCF. Trapping parameters including the order of kinetics (b), activation energy (E) and frequency factor (s-1) were assessed with Chen's peak shape method. Lifetime of trapping centre was found to be (2.36 E+03) s and (9.03 E +01) s regarding the collapsed and structured PCF respectively with 6 Gy of photon beam. For the Ge-doped collapsed PCF, the high TL yield, sensitivity and low fading provide the basis of a highly promising system of TLD for radiotherapy applications.


Subject(s)
Photons , Radiotherapy Dosage , Thermoluminescent Dosimetry/instrumentation , Crystallization , Germanium/chemistry
5.
Appl Radiat Isot ; 174: 109769, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34048993

ABSTRACT

Present work builds upon prior investigations concerning the novel use of graphite-rich polymer pencil-lead for passive radiation dosimetry. Working with photon-mediated interactions at levels of dose familiar in radiotherapy, exploratory investigations have now been made using graphite produced commercially in the form of 50 µm thick sheets. Focusing on the relationship between absorbed radiation energy and induced material changes, investigations have been made of thermo- and photoluminescence dose dependence, also of alterations in Raman spectroscopic features. Photoluminescence studies have focused on the degree of structural order of the samples when exposed to incident MeV energy gamma-radiation, supported by crystallite size evaluations. The results are consistent and evident of structural alterations, radiation-driven thermal annealing also being observed. The results, supportive of previous TL, Raman and photoluminescence studies, are readily understood to arise from irradiation changes occurring at the microscopic level. Notwithstanding the non-linearities observed in the conduct of Raman and photoluminescence studies there is clear potential for applications in use of the defect-dependent methods herein, providing sensitive detection of radiation damage in graphite and from it dose determination. Most specifically, the readily available thin graphite sheets can provide the basis of a low-cost yet highly effective system for studies of radiation-driven changes in carbon (and/or carbon based composites), also as a dosimetric probe of skin dose, its atomic number closely matching with the effective atomic number of soft tissues.

6.
Appl Radiat Isot ; 174: 109757, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33990033

ABSTRACT

This study analysed thermoluminescence (TL) glow curves of the polymer pencil lead graphite (PPLG) due to its potential applications in radiation dosimetry. The TL glow curves provide information on the physical parameters of the defects participating in luminescence process. The glow curves for different diameters PPLG samples were obtained with varying temperature from 50 to 300 °C, at a fixed heating rate of 10 °Cs-1. A number of methods (initial rise, peak shape and curve fitting) were used to fit the TL glow peaks of the PPLG samples obtained under photon dose of 200 Gy. From the fitted TL signals, the trap parameters such as the order of kinetics, the activation energy, the frequency factor, etc. for the individual peaks were numerically determined. The lifetimes of TL process were calculated assuming the first-order kinetics. The results are compared among the different methods adopted in this study. Implications about the possible results in glow curve deconvolution are discussed.

7.
Sci Rep ; 11(1): 7939, 2021 04 12.
Article in English | MEDLINE | ID: mdl-33846448

ABSTRACT

Preliminary study has been made of black human hair, carbon concentration of some 53%, a model in examining the potential of hair of the human head in retrospective and emergency biodosimetry applications, also offering effective atomic number near to that of water. The hair samples were exposed to [Formula: see text]Co gamma rays, delivering doses from 0 to 200 Gy. Structural alterations were observed, use being made of Raman and photoluminescence (PL) spectroscopy. Most prominent among the features observed in the first-order Raman spectra are the D and G peaks, appearing at 1370 [Formula: see text] and 1589 [Formula: see text] respectively, the intensity ratio [Formula: see text] indicating dose-dependent defects generation and annealing of structural alterations. The wavelengths of the PL absorption and emission peaks are found to be centred at [Formula: see text] nm and [Formula: see text] nm, respectively. The hair samples mean band gap energy ([Formula: see text]) post-irradiation was found to be [Formula: see text] eV, of the order of a semiconductor and approximately two times the [Formula: see text] of other carbon-rich materials reported via the same methodology.


Subject(s)
Gamma Rays , Hair/radiation effects , Luminescence , Spectrum Analysis, Raman , Elements , Female , Humans , Spectrometry, X-Ray Emission
8.
PLoS One ; 15(7): e0235053, 2020.
Article in English | MEDLINE | ID: mdl-32673337

ABSTRACT

Study has been made of the thermoluminescence yield of various novel tailor-made silica fibres, 6 and 8 mol % Ge-doped, with four differing outer dimensions, comprised of flat and cylindrical shapes, subjected to electron irradiation. Main thermoluminescence dosimetric characteristics have been investigated, including the glow curve, dose response, energy dependence, minimum detectable dose, effective atomic number, linearity of index and sensitivity of the fibres. The studies have also established the uncertainties involved as well as the stability of response in terms of fading effect, reproducibility and annealing. In addition, dose-rate dependence was accounted for as this has the potential to be a significant factor in radiotherapy applications. The 6 and 8 mol % fibres have been found to provide highly linear dose response within the range 1 to 4 Gy, the smallest size flat fibre, 6 mol% Ge-doped, showing the greatest response by a factor of 1.1 with respect to the highly popular LiF phosphor-based medium TLD100. All of the fibres also showed excellent reproducibility with a standard deviation of < 2% and < 4% for 6 and 8 mol % Ge-doped fibres respectively. For fading evaluation, the smallest 6 mol% Ge-doped dimension flat fibre, i.e., 85 × 270 µm displayed the lowest signal loss within 120 days post-irradiation, at around 26.9% also showing a response superior to that of all of the other fibres. Moreover, all the fibres and TLD-100 chips showed independence with respect to electron irradiation energy and dose-rate. Compared with the 8 mol% Ge-doped optical fibres, the 6 mol% Ge-doped flat optical fibres have been demonstrated to possess more desirable performance features for passive dosimetry, serving as a suitable alternative to TLD-100 for medical irradiation treatment applications.


Subject(s)
Germanium , Optical Fibers/standards , Radiotherapy Dosage , Electrons , Reproducibility of Results , Silicon Dioxide , Thermoluminescent Dosimetry/methods
9.
Appl Radiat Isot ; 105: 158-162, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26313622

ABSTRACT

Over the past decade and more, considerable interest has been shown in the thermoluminescence (TL) properties of silica-based single-mode optical fibres, in particular investigating potential ionising radiation dosimetry applications. Herein, study has been made of TL glow curve, dose response, reproducibility and fading of 6mol% Ge-doped silica, fabricated in-house and produced in the form of cylindrical fibres. Three different pairings of doped-core and silica cladding diameters were produced: (40, 241)µm, (80, 483)µm and (100, 604)µm. The TL results were compared against that of TLD-100, one of the most sensitive commercially available LiF-based TL media. For all three pairings of diameters, closely similar TL glow curve were obtained, formed of a single peaked structure with a maximum TL yield located between the temperatures 250 and 310°C. The TL yield of the fibres were linear over the range of doses investigated, from 1Gy up to 10Gy, their dose response exceeding that of TLD-100, the samples also being found to be reusable, without evidence of degradation.