Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
Toxics ; 9(7)2021 Jul 15.
Article in English | MEDLINE | ID: mdl-34357913

ABSTRACT

The analysis of drugs of abuse in hair and other biological matrices of forensic interest requires great selectivity and sensitivity. This has been traditionally achieved through target analysis, using one or more analytical methods that include different preanalytical stages, and more complex procedures followed by toxicological laboratories. There is no exception with 2C-series drugs, such as 2C-B, a new psychoactive substance (NPS), which use has emerged and significantly increased, year by year, in the last decades. Continuously new analytical methods are required to selectively detect and identify these new marketed substances at very low concentrations. In this case report, one former case of a polydrug consumer (charged of a crime against public health in Spain) was reanalyzed in hair matrix. In this reanalysis, 2C-B has been positively detected and identified using liquid chromatography coupled to high-resolution mass spectrometry (UHPLC-HRMS/MS). The most selective analytical UHPLC-HRMS/MS method alongside a universal and simpler pretreatment methodology has opened up more possibilities for the detection of substances of different chemical structure and optimization of different HRMS/MS detection approaches allowing the identification of 2-CB in the hair of a real forensic case.

3.
J Anal Toxicol ; 44(8): 927-935, 2020 Dec 12.
Article in English | MEDLINE | ID: mdl-32715311

ABSTRACT

Here we report the identification and quantitation of cyclopropyl-fentanyl in a fatality casework occurred due to a poly-drug toxicity in Spain in December 2017. The cyclopropyl-fentanyl was identified in non-biological (paraphernalia) and biological samples (whole-blood, vitreous humor and urine). Conventional techniques (GC-MS) and the UV-Vis spectral allowed differencing between the two structural isomer compounds of fentanyl (cyclopropyl and crotonyl) when the CRM was not available at the laboratory. Both of the drugs have the same MS spectra but different UV-Vis spectra due to the presence of an additional chromophore group in the case of crotonyl. The cyclopropyl-fentanyl detection allowed generating an alert and contributing to the surveillance and detection of this dangerous substance found mixed in doses of clandestine sale heroin. Then, high-resolution analytical techniques (LC-HRMS-MS), showed limitations for the identification of the isobaric fentanyl compounds but they had a high potential for fentanyl metabolites identification. Two tentative metabolites were identified in urine samples: cyclopropyl-norfentanyl and N-methyl cyclopropyl-norfentanyl. Finally, the systematic routine method (LC-MS-MS) was validated and applied to the quantification of cyclopropyl-fentanyl in a blood sample. A obtained value (20.4 ng/mL) was in the range of those reported in other cases in different countries (from 8 to 30 mg/ mL), being the determined concentration of cyclopropyl-fentanyl high enough to infer that this fentanyl analog had a main role as cause of death. As far as we know, this is the first fatality reported in Spain involving cyclopropyl-fentanyl.


Subject(s)
Fentanyl/toxicity , Illicit Drugs/toxicity , Substance Abuse Detection/methods , Analgesics, Opioid , Autopsy , Chromatography, Liquid , Cyclopropanes/toxicity , Drug Overdose , Fatal Outcome , Fentanyl/analysis , Forensic Toxicology , Gas Chromatography-Mass Spectrometry , Humans , Illicit Drugs/analysis , Spain , Tandem Mass Spectrometry , Ultraviolet Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...