1.
S D Med ; 69(8): 351-357, 2016 Aug.
Article in English | MEDLINE | ID: mdl-28806003

ABSTRACT

Trans-catheter aortic valve replacement (TAVR) was approved by the U.S. Food and Drug Administration in 2012 for treatment of severe symptomatic aortic stenosis in non-surgical and high risk patients. Implementation of this complex procedure requires a comprehensive heart team approach. Rural demographics in the Midwest pose many challenges related to low volumes of operations both at institutional and individual levels, leading to serious concerns about the quality of care delivered in such a setting. We compared the TAVR data at the University of South Dakota Sanford Medical Center to the national registry with the aim of looking at differences in outcomes of this procedure in a rural setting.


Subject(s)
Aortic Valve Stenosis/surgery , Rural Population , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Female , Humans , Male , Patient Care Team , Program Evaluation , South Dakota , Treatment Outcome
2.
Ann Thorac Surg ; 79(4): 1372-6; discussion 1376-7, 2005 Apr.
Article in English | MEDLINE | ID: mdl-15797080

ABSTRACT

PURPOSE: Robotic mitral valve repair increases precision however operative times are longer. Prior studies have indicated that robotic knot tying is time consuming and it is without potential room for improvement. We therefore investigated tissue approximation devices that may shorten operative times. DESCRIPTION: A 67-year-old female was approached through a right mini-thoracotomy with the da Vinci Robotic Surgical System (Intuitive Surgical, Sunnyvale, CA). Using 12 nitinol U-clips (Coalescent Surgical, Sunnyvale, CA) an annuloplasty band was placed under robotic guidance. Clip placement and deployment times were recorded and statistical comparisons were assessed to prior suture annuloplasties. EVALUATION: Clip placement time was 1.3 +/- 0.9 (minutes +/- standard deviation), statistical comparison with first, most recent, and all prior suture annuloplasties proving no significance. Clip deployment time was 0.5 +/- 0.2, whereas knot-tying times and respective statistical comparison for first, most recent, and all prior suture annuloplasties were 2.0 +/- 0.7 (p = 0.003), 1.2 +/- 0.4 (p = 0.0004), and 1.6 +/- 0.6 (p < 0.00001). Follow-up echocardiography performed postoperatively, at 3 months, and at 9 months revealed valvular structural integrity with only minimal mitral regurgitation. CONCLUSIONS: U-clips considerably reduce time for annuloplasty over conventional suture and may help reduce operative times as well.


Subject(s)
Cardiac Surgical Procedures/instrumentation , Mitral Valve/surgery , Robotics/methods , Aged , Female , Humans , Suture Techniques , Time Factors
3.
Am J Cardiovasc Drugs ; 4(4): 219-25, 2004.
Article in English | MEDLINE | ID: mdl-15285697

ABSTRACT

This article presents some of the cost factors involved in selecting coronary artery revascularization therapy in an elderly patient. With the percentage of gross national product allocated to healthcare continuing to rise in the US, resource allocation has become an issue. Percutaneous coronary intervention continues to be a viable option for many patients, with lower initial costs. However, long-term angina-free results often require further interventions or eventual surgery. Once coronary artery revascularization therapy is selected, it is worthwhile to evaluate the cost considerations inherent to various techniques. Off-pump coronary artery bypass graft surgery has seen a resurgence, with improved technology and lower hospital costs than on-pump bypass surgery. Numerous factors contributing to cost in coronary surgery have been studied and several are documented here, including the potential benefits of early extubation and the use of standardized optimal care pathways. A wide range of hospital-level cost variation has been noted, and standardization issues remain. With the advent of advanced computer-assisted robotic techniques, a push toward totally endoscopic bypass surgery has begun, with the eventual hope of reducing hospital stays to a minimum while maximizing outcomes, thus reducing intensive care unit and stepdown care times, which contribute a great deal toward overall cost. At the present time, these techniques add a significant premium to hospital charges, outweighing any potential length-of-stay benefits from a cost standpoint. As our elderly population continues to grow, use of healthcare resource dollars will continue to be heavily scrutinized. Although the clinical outcome remains the ultimate benchmark, cost containment and optimization of resources will take on a larger role in the future.


Subject(s)
Coronary Artery Disease/surgery , Myocardial Revascularization/economics , Aged , Angioplasty, Balloon, Coronary/economics , Coronary Artery Bypass/economics , Costs and Cost Analysis , Endoscopy , Humans , Mammary Arteries/transplantation , Radial Artery/transplantation , Risk Assessment , Robotics
4.
J Surg Res ; 115(2): 209-13, 2003 Dec.
Article in English | MEDLINE | ID: mdl-14697285

ABSTRACT

BACKGROUND: Application of the Vacuum-Assisted Closure device (VAC) to open sternal wounds has negative hemodynamic effects. We hypothesized that the interposition of a muscle flap attenuates these negative hemodynamic effects. MATERIALS AND METHODS: After institutional approval, monitoring lines were placed in anesthetized, ventilated pigs. Through a median sternotomy, sonometric crystals were strategically positioned around the left ventricle. A rectus flap was rotated over the mediastinal wound, and the VAC was placed over the flap. After baseline measurements, a vacuum of 125 mmHg [Group (GP) 1, n = 5] or 50 mmHg (GP2, n = 6) was initiated. Hemodynamics were recorded every 15 min for 1.5 h, and 15 min after cessation of the vacuum therapy. GP3 (n = 6) underwent intermittent VAC cycling (on 5 min/off 2 min). Significance determined by t test. RESULTS: While non-flapped animals had significant detriment in both left ventricular filling volume and cardiac output, flapped animals had insignificant depression of both parameters. CONCLUSION: Application of muscle flaps to sternal wounds prior to VAC therapy significantly attenuates the negative hemodynamic effects seen when the VAC is used alone.


Subject(s)
Cardiac Surgical Procedures/instrumentation , Cardiac Surgical Procedures/methods , Sternum/surgery , Wound Healing , Animals , Regional Blood Flow , Stroke Volume , Surgical Flaps , Surgical Wound Infection/prevention & control , Swine , Vacuum
5.
Heart Surg Forum ; 6(4): 254-7, 2003.
Article in English | MEDLINE | ID: mdl-12928210

ABSTRACT

BACKGROUND: Robotic mitral valve repair with the da Vinci robotic surgical system has been performed in more than 70 patients at our institution. This procedure reduces the need for blood transfusions, shortens hospital stay, and hastens return to normal activities. However, the robot-assisted repair also requires longer cardiopulmonary bypass and arrested-heart times than conventional open repairs. Because of increased risk of myocardial damage, arrhythmia, and other significant morbidities associated with longer arrested-heart time, a more efficient tissue approximation and adherence technique was evaluated to reduce operating time. METHODS: Twelve Dorset sheep were divided equally into 2 groups. In the control group Cosgrove-Edwards annuloplasty bands were secured to the posterior annulus with conventional 2-0 Ticron mattress sutures placed with robotic assistance. In the experimental group, the band was secured with double-armed nitinol U-clips placed with robotic assistance. Postoperative echocardiography was used to assess mitral valve function, and the animals were sacrificed at 3 or 6 months for histological evaluation. RESULTS: Total U-clip placement time was significantly decreased at 2.6 +/- 0.2 (mean +/- SEM) minutes versus total suture placement time at 4.9 +/- 0.4 minutes (P =.001). The main difference in time occurred between clip deployment at 0.75 +/- 0.1 minutes and suture tying at 2.78 +/- 0.2 minutes (P =.000003). Pathologic review showed excellent band incorporation at 3 and 6 months. Echocardiographic imaging showed no discernible mitral valve stenosis or regurgitation. CONCLUSIONS: With more cardiac procedures progressing toward minimally invasive approaches, novel technology to improve existing techniques must be evaluated. Nitinol U-clips help to reduce arrested-heart time and may improve outcome by decreasing morbidity. U-clip placement is intuitive, easily learned, and effective in securing the annuloplasty band to the mitral annulus.


Subject(s)
Mitral Valve/surgery , Models, Animal , Robotics , Surgical Instruments , Animals , Cardiac Surgical Procedures/methods , Sheep , Suture Techniques
6.
Ann Thorac Surg ; 75(2): 438-42; discussion 443, 2003 Feb.
Article in English | MEDLINE | ID: mdl-12607651

ABSTRACT

BACKGROUND: As part of a Food and Drug Administration trial, mitral repairs were performed in 38 patients using the robotic da Vinci surgical system (Intuitive Surgical, Inc, Mountain View, CA). Prospectively, we evaluated safety and efficacy in performing both simple and complex mitral repairs. METHODS: Eligible patients had nonischemic moderate to severe mitral insufficiency. Operative techniques included peripheral cardiopulmonary perfusion, a 4- to 5-cm mini-thoracotomy, transthoracic aortic occlusion, and antegrade blood cardioplegia. Transesophageal echocardiograms were done intraoperatively with three-dimensional reconstructions. Successful repairs were defined as mild or less residual regurgitation. RESULTS: Enhanced three-dimensional visualization of mitral leaflets and the subvalvar apparatus allowed safe, dexterous intracardiac tissue manipulation. All patients had successful valve repairs including quadrangular resections, sliding plasties, and edge-to-edge approximations, as well as both chordal transfers and replacements. There were no operative deaths, strokes, or device-related complications. One patient required valve replacement for hemolysis and 1 was reexplored for bleeding. There were no incisional conversions. Both robotic repair and total operating times decreased significantly from 1.9 +/- 0.1 and 5.1 +/- 0.1 hours (mean +/- standard error of the mean) for the first 19 patients to 1.5 +/- 0.1 (p = 0.002) and 4.4 +/- 0.1 hours (p = 0.04) for the last 19 operations, respectively. Total hospital length of stay for patients was 3.8 +/- 0.6 days. Of all patients, 31 (82%) had a 4-day or less length of stay. Seven patients (18%) had stays between 5 and 9 days (6.4 +/- 1.0). CONCLUSIONS: This study shows that the da Vinci surgical system (Intuitive Surgical, Inc) has few limitations in performing complex valve repairs. Articulated wrist-like instruments and three-dimensional visualization enabled precise tissue telemanipulation. Future robotic design advances and adjunctive suture technologies may promote continuing evolution of robotic cardiac operations.


Subject(s)
Cardiac Surgical Procedures/instrumentation , Mitral Valve Insufficiency/surgery , Robotics/instrumentation , Cardiac Surgical Procedures/methods , Humans , Imaging, Three-Dimensional , Length of Stay , Middle Aged , Prospective Studies , Robotics/methods , Suture Techniques